Rakesh Verma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rakesh Verma has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
A. V. R. Reddy
Analytical Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, India
5 shared publicationsP. S. Remya Devi
Analytical Chemistry Division Bhabha Atomic Research Centre Trombay Mumbai 400085 India
4 shared publicationsA. K. Dinkar
Fuel Reprocessing Division, Bhabha Atomic Research Centre, Trombay, Mumbai, India
3 shared publicationsK. K. Swain
Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
3 shared publicationsSuman Kumar Singh
Fuel Reprocessing Division, Bhabha Atomic Research Centre, Trombay, Mumbai, India
3 shared publicationsA. A. Dalvi
Analytical Chemistry Division, Bhabha Atomic Research Centre, Mumbai, India
2 shared publications
Latest Publications
- 17 April 2017
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (8) , 1359-1364
Extraction of protactinium from acid media using Aliquat 336
Solvent extraction studies on protactinium were carried out from hydrofluoric acid, hydrochloric acid, and a mixture of hydrochloric and hydrofluoric acids using Aliquat 336 and 231Pa. The extraction of protactinium from hydrofluoric acid (0.025–10 M) decreased with increasing acid concentration and was less than 10% above 5 M. The extraction from hydrochloric acid (0.5–8 M) started only above 4 M and increased with increasing acid concentration. The extraction of protactinium from a mixture containing hydrochloric acid (0.5–8 M) and 0.03 M hydrofluoric acid decreased with increasing acid concentration reached to a minimum at about 2 M and then increased with increasing acid concentration. At low acidity, extraction of protactinium from hydrofluoric acid was higher compared to hydrochloric acid and the mixture of hydrochloric and hydrofluoric acids. Nitric acid (10 M) and hydrofluoric acid (10 M) were suitable for quantitative recovery of protactinium from organic phase. The extraction of 231Pa from real thorium lean raffinate of thorium–uranium extraction process was studied using optimized extraction conditions.
- 17 April 2017
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 52 (8) , 1359-1364
Extraction of protactinium from acid media using Aliquat 336
Solvent extraction studies on protactinium were carried out from hydrofluoric acid, hydrochloric acid, and a mixture of hydrochloric and hydrofluoric acids using Aliquat 336 and 231Pa. The extraction of protactinium from hydrofluoric acid (0.025–10 M) decreased with increasing acid concentration and was less than 10% above 5 M. The extraction from hydrochloric acid (0.5–8 M) started only above 4 M and increased with increasing acid concentration. The extraction of protactinium from a mixture containing hydrochloric acid (0.5–8 M) and 0.03 M hydrofluoric acid decreased with increasing acid concentration reached to a minimum at about 2 M and then increased with increasing acid concentration. At low acidity, extraction of protactinium from hydrofluoric acid was higher compared to hydrochloric acid and the mixture of hydrochloric and hydrofluoric acids. Nitric acid (10 M) and hydrofluoric acid (10 M) were suitable for quantitative recovery of protactinium from organic phase. The extraction of 231Pa from real thorium lean raffinate of thorium–uranium extraction process was studied using optimized extraction conditions.
- 1 February 2016
- Published by Wiley in X-Ray Spectrometry
- Vol. 45 (3) , 162-168
Preconcentration of mercury on polyaniline expands the horizon for energy dispersive X‐ray fluorescence determination
Hg(II) was sorbed on polyaniline from aqueous solutions, followed by determination using energy dispersive X‐ray fluorescence spectrometry. Distribution coefficient of Hg(II) on polyaniline was about 4 × 10 3 in water, whereas distribution coefficient was 1.2 × 10 4 at 0.1 M HCl and decreased drastically with increase in HCl concentration. Rapid kinetics of sorption was evinced by the 80% uptake within the initial 1 min and quantitative sorption within 5 min of equilibration. The sorption was found to follow Langmuir isotherm model, and the Langmuir capacity was calculated as 19.7 mg g −1 . The ability of polyaniline to form stable and homogeneous pellets facilitated the energy dispersive X‐ray fluorescence determination without recourse to elution. Detection limit of Hg was found to be 22 ng, considering 100 mg pellet of polyaniline. The apparent detection limit was 6 pg, as the preconcentration factor of Hg(II) on polyaniline was 4 × 10 3 . The developed method is at par with the established method for mercury determination, namely, cold vapor atomic absorption spectrometry. Accuracy of the method was established by the analysis of the International Atomic Energy Agency reference materials, namely, hair and lichen, for Hg(II). Copyright © 2016 John Wiley & Sons, Ltd.
- 1 February 2016
- Published by Wiley in X-Ray Spectrometry
- Vol. 45 (3) , 162-168
Preconcentration of mercury on polyaniline expands the horizon for energy dispersive X‐ray fluorescence determination
Hg(II) was sorbed on polyaniline from aqueous solutions, followed by determination using energy dispersive X‐ray fluorescence spectrometry. Distribution coefficient of Hg(II) on polyaniline was about 4 × 10 3 in water, whereas distribution coefficient was 1.2 × 10 4 at 0.1 M HCl and decreased drastically with increase in HCl concentration. Rapid kinetics of sorption was evinced by the 80% uptake within the initial 1 min and quantitative sorption within 5 min of equilibration. The sorption was found to follow Langmuir isotherm model, and the Langmuir capacity was calculated as 19.7 mg g −1 . The ability of polyaniline to form stable and homogeneous pellets facilitated the energy dispersive X‐ray fluorescence determination without recourse to elution. Detection limit of Hg was found to be 22 ng, considering 100 mg pellet of polyaniline. The apparent detection limit was 6 pg, as the preconcentration factor of Hg(II) on polyaniline was 4 × 10 3 . The developed method is at par with the established method for mercury determination, namely, cold vapor atomic absorption spectrometry. Accuracy of the method was established by the analysis of the International Atomic Energy Agency reference materials, namely, hair and lichen, for Hg(II). Copyright © 2016 John Wiley & Sons, Ltd.
- 1 June 2015
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 50 (8) , 866-873
Sorption of arsenic on manganese dioxide synthesized by solid state reaction
Arsenic in groundwater is a major concern in many parts of the world and suitable sorbents are required for removal of arsenic from ground water. Removal of arsenic from groundwater has been studied using manganese dioxide, synthesized by solid state reaction of manganese acetate with potassium permanganate. Manganese dioxide was characterized by X-ray diffraction (XRD), zeta potential, surface area, particle size measurements and thermal analysis. XRD measurement showed that the manganese dioxide had α-MnO2 structure. Sorption of As(III) and As(V) on manganese dioxide was studied by radiotracer technique using 76As radio isotope. Arsenic removal efficiency for both As(III) and As(V) at concentration of 2 mg L−1 was ∼99% in the pH range of 3–9. The sorption capacities for As(III) and As(V) were ∼60 mg g−1. Kinetic studies showed that the equilibrium was reached within 30 s. Arsenic sorbed on manganese dioxide was present as As(V) irrespective of initial oxidation state. The presence of Ca2+, Mg2+, Cl− and SO42− up to a concentration of 1000 mg L−1 had no significant effect on arsenic sorption. The sorption of arsenic decreased significantly in the presence of phosphate and bicarbonate anions above 10 mg L−1. Arsenic sorbed on manganese dioxide was desorbed by 0.1M NaOH. Arsenic was effectively removed by manganese dioxide from groundwater samples collected from arsenic contaminated areas of West Bengal, India.
- 1 June 2015
- Published by Taylor & Francis in Journal of Environmental Science and Health, Part A
- Vol. 50 (8) , 866-873
Sorption of arsenic on manganese dioxide synthesized by solid state reaction
Arsenic in groundwater is a major concern in many parts of the world and suitable sorbents are required for removal of arsenic from ground water. Removal of arsenic from groundwater has been studied using manganese dioxide, synthesized by solid state reaction of manganese acetate with potassium permanganate. Manganese dioxide was characterized by X-ray diffraction (XRD), zeta potential, surface area, particle size measurements and thermal analysis. XRD measurement showed that the manganese dioxide had α-MnO2 structure. Sorption of As(III) and As(V) on manganese dioxide was studied by radiotracer technique using 76As radio isotope. Arsenic removal efficiency for both As(III) and As(V) at concentration of 2 mg L−1 was ∼99% in the pH range of 3–9. The sorption capacities for As(III) and As(V) were ∼60 mg g−1. Kinetic studies showed that the equilibrium was reached within 30 s. Arsenic sorbed on manganese dioxide was present as As(V) irrespective of initial oxidation state. The presence of Ca2+, Mg2+, Cl− and SO42− up to a concentration of 1000 mg L−1 had no significant effect on arsenic sorption. The sorption of arsenic decreased significantly in the presence of phosphate and bicarbonate anions above 10 mg L−1. Arsenic sorbed on manganese dioxide was desorbed by 0.1M NaOH. Arsenic was effectively removed by manganese dioxide from groundwater samples collected from arsenic contaminated areas of West Bengal, India.
- Open Access
- 11 May 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (12) , 5345-5351
Evaluation of uncertainty in the energy dispersive X-ray fluorescence determination of platinum in alumina
Evaluation of uncertainty in the Energy Dispersive X-ray Fluorescence (EDXRF) spectrometric determination of platinum in alumina catalysts is discussed. Pressed pellets of the platinum standard and a catalyst sample were prepared by using microcrystalline cellulose powder as the base material. A linear calibration of the X-ray fluorescence spectrometer was obtained in the range of 0.1–3 mg g−1 of platinum using pellets of matrix matched synthetic standards. The calibration function was obtained through bivariate least squares fitting, in conjunction with weighted regression of the residuals. The EDXRF results were compared with those obtained by instrumental neutron activation analysis and inductively coupled plasma optical emission spectrometry. Analysis of variance established the statistical parity of the results obtained by all the three techniques. A comprehensive evaluation of the various sources of uncertainty in the complete measurement process was carried out using a bottom-up approach. The main source of uncertainty was identified as the calibration of the EDXRF spectrometer, in which the major share was attributed to the intercept of the calibration function.
- 11 May 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (12) , 5345-5351
Open AccessEvaluation of uncertainty in the energy dispersive X-ray fluorescence determination of platinum in alumina
Evaluation of uncertainty in the Energy Dispersive X-ray Fluorescence (EDXRF) spectrometric determination of platinum in alumina catalysts is discussed. Pressed pellets of the platinum standard and a catalyst sample were prepared by using microcrystalline cellulose powder as the base material. A linear calibration of the X-ray fluorescence spectrometer was obtained in the range of 0.1–3 mg g−1 of platinum using pellets of matrix matched synthetic standards. The calibration function was obtained through bivariate least squares fitting, in conjunction with weighted regression of the residuals. The EDXRF results were compared with those obtained by instrumental neutron activation analysis and inductively coupled plasma optical emission spectrometry. Analysis of variance established the statistical parity of the results obtained by all the three techniques. A comprehensive evaluation of the various sources of uncertainty in the complete measurement process was carried out using a bottom-up approach. The main source of uncertainty was identified as the calibration of the EDXRF spectrometer, in which the major share was attributed to the intercept of the calibration function.
- Open Access
- 30 March 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (9) , 3833-3840
Comparison and statistical evaluation of neutron activation methodologies for the determination of gold in copper concentrate
Gold was determined in copper concentrate by an instrumental neutron activation analysis technique using the relative method. The determination was repeated by radiochemical and chemical neutron activation analysis with the aid of an anion exchange strategy for the chemical separation of gold from the matrix (Fe, Cu, and Zn). Irradiation of copper concentrate samples was carried out in APSARA reactor (BARC, India) with a thermal neutron flux of about 1012 cm−2 s−1. Analysis of variance established that the results obtained by instrumental, radiochemical and chemical methodologies were statistically indistinguishable. Among the three approaches, radiochemical activation showed superior detection limits, which was attributed to both the reduction in background and increase in sensitivity. The best measurement repeatability was observed in chemical activation methodology, compared to the other two. The rationale behind the improvement in measurement repeatability was the capability of chemical activation to process a larger mass of sample for each replicate, which resulted in improved counting statistics and reduction in sampling error with respect to gold. Combined uncertainty for all the three methodologies was evaluated through the bottom-up approach. Systematic evaluation of various uncertainty parameters showed that the major contributor to the combined standard uncertainty was the counting statistics during the instrumental approach and the chemical separation yield during radiochemical and chemical activation. The combined uncertainty for all the three approaches was less than the measurement repeatability indicating the inhomogeneous distribution of gold in copper concentrate. Calculations showed that the sampling constant for gold in copper concentrate was about 22 g.
- 30 March 2015
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 7 (9) , 3833-3840
Open AccessComparison and statistical evaluation of neutron activation methodologies for the determination of gold in copper concentrate
Gold was determined in copper concentrate by an instrumental neutron activation analysis technique using the relative method. The determination was repeated by radiochemical and chemical neutron activation analysis with the aid of an anion exchange strategy for the chemical separation of gold from the matrix (Fe, Cu, and Zn). Irradiation of copper concentrate samples was carried out in APSARA reactor (BARC, India) with a thermal neutron flux of about 1012 cm−2 s−1. Analysis of variance established that the results obtained by instrumental, radiochemical and chemical methodologies were statistically indistinguishable. Among the three approaches, radiochemical activation showed superior detection limits, which was attributed to both the reduction in background and increase in sensitivity. The best measurement repeatability was observed in chemical activation methodology, compared to the other two. The rationale behind the improvement in measurement repeatability was the capability of chemical activation to process a larger mass of sample for each replicate, which resulted in improved counting statistics and reduction in sampling error with respect to gold. Combined uncertainty for all the three methodologies was evaluated through the bottom-up approach. Systematic evaluation of various uncertainty parameters showed that the major contributor to the combined standard uncertainty was the counting statistics during the instrumental approach and the chemical separation yield during radiochemical and chemical activation. The combined uncertainty for all the three approaches was less than the measurement repeatability indicating the inhomogeneous distribution of gold in copper concentrate. Calculations showed that the sampling constant for gold in copper concentrate was about 22 g.
- 25 March 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 306 (1) , 147-153
Sorption of niobium on colloidal silica and the effect of humic acid
- 25 March 2015
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 306 (1) , 147-153
Sorption of niobium on colloidal silica and the effect of humic acid
- Open Access
- 31 October 2014
- Published by Wiley in X-Ray Spectrometry
- Vol. 44 (1) , 13-15
Determination of gold and silver in dross using EDXRF technique
Gold and silver in dross were determined by energy‐dispersive X‐ray fluorescence technique. Sample was prepared by pressed pellet method using microcrystalline cellulose powder as binder, and a method of standard additions was used for quantification. L β X‐ray of gold (11.4 keV) and K β X‐ray of silver (24.9 keV) were used for analysis. The measured concentrations of gold and silver were 132 ± 8 and 1181 ± 84 mg kg −1 , respectively. The results were validated by instrumental neutron activation analysis technique. The t ‐test indicated that there was no significant difference between results obtained by the two techniques. Energy‐dispersive X‐ray fluorescence is a simple, precise and accurate technique for the determination of gold and silver in dross. Copyright © 2014 John Wiley & Sons, Ltd.
- 31 October 2014
- Published by Wiley in X-Ray Spectrometry
- Vol. 44 (1) , 13-15
Open AccessDetermination of gold and silver in dross using EDXRF technique
Gold and silver in dross were determined by energy‐dispersive X‐ray fluorescence technique. Sample was prepared by pressed pellet method using microcrystalline cellulose powder as binder, and a method of standard additions was used for quantification. L β X‐ray of gold (11.4 keV) and K β X‐ray of silver (24.9 keV) were used for analysis. The measured concentrations of gold and silver were 132 ± 8 and 1181 ± 84 mg kg −1 , respectively. The results were validated by instrumental neutron activation analysis technique. The t ‐test indicated that there was no significant difference between results obtained by the two techniques. Energy‐dispersive X‐ray fluorescence is a simple, precise and accurate technique for the determination of gold and silver in dross. Copyright © 2014 John Wiley & Sons, Ltd.
- 9 September 2013
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 96, 75-80
Effect of gamma irradiation on the ion exchange capacity of polyaniline
- 9 September 2013
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 96, 75-80
Effect of gamma irradiation on the ion exchange capacity of polyaniline
- 19 June 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 298 (1) , 707-715
Carrier facilitated transport of thorium from HCl medium using Cyanex 923 in n-dodecane containing supported liquid membrane
- 19 June 2013
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 298 (1) , 707-715
Carrier facilitated transport of thorium from HCl medium using Cyanex 923 in n-dodecane containing supported liquid membrane
- 25 April 2012
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 47 (12) , 1748-1753
Studies on the Separation and Recovery of Thorium from Nitric Acid Medium using (2-ethyl hexyl) Phosphonic Acid, Mono (2-ethyl hexyl) Ester (PC88A)/N-Dodecane as Extractant System
This paper deals with the studies on the separation and recovery of thorium and 233-uranium from nitric acid medium using (2-ethyl hexyl) phosphonic acid, mono (2-ethyl hexyl) ester/n-dodecane as an extractant system. The different extraction parameters were investigated. The distribution ratio of thorium decreased with increase in nitric acid concentration. The optimum solvent concentration for quantitative separation of thorium from aqueous feed solution was 0.75 M of PC88A whereas dodecane was the most suitable of diluents with an organic to aqueous phase ratio of 1:1. Among the various strippants used, 2 M solution of (NH4)2CO3 was found to be the most suitable for back extraction of thorium. The developed method was used to recover thorium and 233U from radioanalytical waste generated during thorium analysis by ethylene diamine tetraacetic acid (EDTA) titremtric method and recoveries for both Th and U were more than 85%.
- 25 April 2012
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 47 (12) , 1748-1753
Studies on the Separation and Recovery of Thorium from Nitric Acid Medium using (2-ethyl hexyl) Phosphonic Acid, Mono (2-ethyl hexyl) Ester (PC88A)/N-Dodecane as Extractant System
This paper deals with the studies on the separation and recovery of thorium and 233-uranium from nitric acid medium using (2-ethyl hexyl) phosphonic acid, mono (2-ethyl hexyl) ester/n-dodecane as an extractant system. The different extraction parameters were investigated. The distribution ratio of thorium decreased with increase in nitric acid concentration. The optimum solvent concentration for quantitative separation of thorium from aqueous feed solution was 0.75 M of PC88A whereas dodecane was the most suitable of diluents with an organic to aqueous phase ratio of 1:1. Among the various strippants used, 2 M solution of (NH4)2CO3 was found to be the most suitable for back extraction of thorium. The developed method was used to recover thorium and 233U from radioanalytical waste generated during thorium analysis by ethylene diamine tetraacetic acid (EDTA) titremtric method and recoveries for both Th and U were more than 85%.