EBEvgeny Gennadievich Bazulin

Evgeny Gennadievich Bazulin

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Evgeny Gennadievich Bazulin has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Mapping of the Grain Size Number in Cylindrical Specimens from Images Reconstructed by the Digital Aperture Focusing Method

    by A. E. Bazulin, E. G. Bazulin, A. H. Vopilkin, S. V. Romashkin, D. S. Tikhonov

    In the process of manufacturing various blanks, it becomes necessary to estimate the grain size (crystallites), which determines the mechanical properties of the material. Traditional metallographic studies are laborious and make it possible to estimate the grain size only on the surface of the workpiece, but not inside it. The dependence of ultrasound scattering on grain size and frequency makes it possible to estimate grain size when analyzing ultrasound attenuation or when estimating the amplitude of scattered pulses. The digital aperture focusing (DFA) method restores high-resolution images of reflectors in the form of scattered field amplitude maps. By reconstructing images from echo signals measured by phased arrays with operating frequencies of 2.25, 5, and 10 MHz and using Rose’s theory, it is possible to estimate the grain size inside the test object.

  • Determination of the Height of Planar Reflectors from Multi-Mode DAF-Images

    by A. E. Bazulin, E. G. Bazulin, A. A. Efimovskaya

    After solving the problem of detecting a reflector and determining its type based on the results of ultrasonic testing, it is necessary to estimate the size of the reflector, as this determines the need for repair of the inspected object. The analysis of images obtained using the digital aperture focusing (DAF) method on different acoustic patterns (modes) allows for the creation of high-quality images of the reflector. The article proposes a method for estimating the height of planar reflectors based on multi-pattern DAF images, including those in anisotropic steel objects. Numerical and model experiments have shown that the accuracy of estimating the height of a planar reflector is approximately half the wavelength.

  • Improving the Accuracy of Measuring the Parameters of Frequency-Dependent Attenuation of a Longitudinal Ultrasonic Wave in Solids

    by E. G. Bazulin, E. S. Dolgova

    The article proposes a method for improving the accuracy of measuring the parameters of frequency-dependent attenuation of longitudinal ultrasonic waves in solids using standard flaw detectors and piezoelectric transducers. Traditional approaches such as Papadakis and Roth methods are considered and their limitations are revealed due to the difficulties of accounting for reflection coefficients, wave front divergence, and the influence of a contact layer. An improved method based on the Rota method using a multifrequency correction of wavefront divergence is proposed, and an optimization method based on the NSGA-II genetic multicriteria algorithm for estimating attenuation parameters is proposed. The analysis of the following factors affecting the measurement accuracy is carried out: frequency characteristics of the transducer, amplitude measurement errors, the presence of structural noise, sampling step, energy leakage at the boundaries of the sample, etc. The results of numerical experiments performed in the CIVA program, when using a transducer with an operating frequency of 5 MHz, showed a relative error in measuring the speed of sound at \( \pm 0.1\% \), attenuation coefficient \( \pm 1.5\% \), and degree of frequency dependence \( \pm 20\% \). A model experiment on a steel sample with two “steps” of 12 and 20 mm using a transducer with an operating frequency of 10 MHz confirmed the practical applicability of the method: the relative error in measuring the longitudinal wave velocity for two “steps” can be estimated as \( \pm 0.1\% \), the attenuation coefficient as \( \pm 1\% \), and the degree of frequency dependence \( \pm 2\% \). To increase accuracy, it is recommended to use transducers with an operating frequency of 10 MHz and twin transducer probe.

  • Determination of Flaw Detector Impulse Response to Achieve Super-Resolution of Reflector Images Based on Echo Signals Measured by an Antenna Array

    by E. G. Bazulin, A. A. Krylovich

    In ultrasonic inspection, digital aperture focusing (DAF) is increasingly being used to reconstruct reflector images. The reliability of inspection is determined by the quality of the DAF image—signal-to-noise ratio, ability to reconstruct the image of the entire reflector boundary, and resolution. Various methods are used to achieve super-resolution of echoes: maximum entropy method, methods of building autoregressive signal models, compressive sensing (CS) method, etc. To use these methods, it is important to know the impulse response of the ultrasound system, which can be measured or obtained using “blind” deconvolution methods used in image and signal processing. In this paper we consider the minimum entropy deconvolution (MED) method for estimating the impulse response of an ultrasonic flaw detector and achieving the effect of image super-resolution, where knowledge of the transfer function of the system is critical. The effectiveness of the proposed method is confirmed by the results of model experiments.


  • Recognition of Reflector Type Using Neural Network Based on TOFD Echoes

    by E. G. Bazulin, L. V. Medvedev

    In this paper we propose to automate the classification of reflector types by TOFD echoes using the ResNet-18 convolutional neural network. The main focus is on modeling and classification of reflectors such as cracks, pores, nonwelds, and void areas. Experiments included training the model on TOFD echoes calculated both in a numerical experiment and TOFD echoes measured during ultrasonic inspection. The results showed high classification accuracy: 96.2% in the numerical experiment, 97% on experimentally measured TOFD echoes with various types of reflectors. The study confirmed the possibility of using neural networks to determine the reflector type based on TOFD echo signals; this allows automating the process of nondestructive testing and reduce the influence of human factor. For further development of the method it is suggested to use segmentation models for processing images with several reflectors.


  • Cepstral Analysis of Ultrasonic Echoes Measured by an Antenna Array in Order to Obtain Super-Resolution Images of Reflectors

    by E. G. Bazulin, A. A. Krylovich

    The digital focusing aperture (DFA) method is widely used to image reflectors during ultrasonic inspection. The reliability of inspection is determined by the quality of the DFA image—resolution and signal-to-noise ratio. To achieve super-resolution of echo signals, which will lead to lateral super-resolution of reflectors, various methods are used: maximum entropy method, Bernoulli–Gaussian deconvolution, Lucy–Richardson deconvolution, methods of recognition with compression (CS), methods of construction of autoregressive models of signals, etc. To apply these methods, we need to know the impulse response of the ultrasonic inspection system. It can be measured, but you can use methods of “blind” deconvolution, which are used in image and signal processing. For example: the method of eliminating camera blur at its random displacement, maximum correlated kurtosis deconvolution (MCKD), cepstral analysis, etc. In this paper, a cepstral analysis method for super-resolution or for obtaining information about the impulse response of the system is considered to construct an AR spectrum model to obtain the lateral super-resolution of DFA-images. The performance of the proposed method is confirmed by model experiments.


  • Application of CF and DMAS Technology to Improve the Quality of Reflector Images Reconstructed from Echoes Measured by an Antenna Array

    by E. G. Bazulin, Базулин Е. Г.

    Reliability and sensitivity of ultrasonic control is determined by the noise level of the reflector image and its resolution. Application of CF- or DMAS-technology in various combinations is promising, as these technologies are simple enough, practically do not require additional computational resources, are applied to echo signals measured by conventional flaw detectors working with antenna arrays. In numerical and model experiments it is demonstrated that the application of these methods allows to increase the resolution of reflector images more than twice and to reduce the noise level by more than 20 dB. In the numerical experiment it is shown that phase distortions due to complex refractive and reflection coefficients lead to the fact that even with precisely known parameters of the experiment when working on a direct beam on a transverse wave the indication of the crack tip can shift from its true position by about a wavelength. For the solution of defectometry tasks this is a very large error. But, if phase correction is performed when reconstructing the reflector image, the crack tip indication coincides with its real position. CF- and DMAS-technologies have shown their workability also when working with noisy echoes.


  • Application of CF and DMAS Technology to Improve the Quality of Reflector Images Reconstructed from Echoes Measured by an Antenna Array

    by E. G. Bazulin

    The reliability and sensitivity of ultrasonic testing are determined by the noise level in the images of reflectors and their resolution. The application of CF or DMAS technologies in various combinations is promising, as these technologies are relatively simple, require minimal additional computational resources, and can be applied to echo signals measured by conventional flaw detectors operating with antenna arrays. Numerical and model experiments have demonstrated that the use of these methods allows for an increase in the resolution of the images of reflectors by more than two times and a reduction in noise level by more than 20 dB. In a numerical experiment, it was shown that phase distortions due to complex coefficients of refraction and reflection can cause the indication of the crack tip to shift from its true position by approximately one wavelength, even with precisely known experimental parameters when operating on a straight beam on a transverse wave. This represents a significant error for flaw detection tasks. However, if phase correction is applied during the reconstruction of the images of reflectors, then the indication of the crack tip aligns with its actual position. CF and DMAS technologies have demonstrated their effectiveness even when working with noisy echo signals.


  • Image Restoration of Reflectors by Digital Focusing of the Aperture in Thick-Walled Pipes of Small Diameter

    by E. G. Bazulin

    When performing ultrasonic testing of pipes of various diameters using antenna arrays and matrices, two technologies for imaging reflectors—the total focusing method (TFM) and the digital aperture focusing (DAF)—are widely used. If the pipe diameter is greater than a hundred wavelengths, the DAF can be utilized for reflector imaging, considering multiple reflections from boundaries while assuming that the test object is flat. The errors in forming the DAF image of reflectors will be minimal in this case. However, if the pipe diameter is several tens of wavelengths and the wall thickness is approximately half the pipe diameter, then to obtain a quality DAF image of the reflectors, the geometry of the test object must be taken into account. This paper examines the features of image formation when recording echo signals with an antenna array or matrix while scanning both the outer and inner surfaces of the test object. Numerical and model experiments demonstrate that to achieve high-quality DAF images of reflectors when scanning the outer surface of a thick-walled pipe with a small diameter, both an antenna array and an antenna matrix can be used. This is due to the presence of the physical focusing effect of the ultrasonic field. However, when scanning the inner surface of a thick-walled pipe with a small diameter, echo signals must be recorded using an antenna matrix to reconstruct the image of the reflectors due to the defocusing effect.

  • Assessment of the Possibilities of Ultrasound Tomographic Imaging of Multi-Layer Composite Materials

    by E. G. Bazulin, A. V. Goncharsky, S. Y. Romanov, S. Y. Seryozhnikov

    The article discusses the possibilities of ultrasonic inspection of layered composite materials, which are widely used in automobile and aerospace industries, using wave tomography imaging method. This method obtains an image of the distribution of the longitudinal wave velocity inside the material by solving the coefficient inverse problem for the wave equation under the scalar wave model. The problems of detecting various defects in a layered material by sounding a sample with ultrasonic waves from a single side and registering the reflected waves are discussed. The use of waves reflected from known and unknown opposite boundaries of the sample are considered. Influence of a coupling layer between the transducers and the test sample on the quality of tomographic image reconstruction is discussed. The results of numerical experiments on reconstructing the structure of a sample using wave tomography are compared with the widely used DFA method (digital focusing with an antenna). Inverse problems of ultrasound tomography are nonlinear and, unlike common methods like DFA and synthetic aperture focusing (SAFT), require the use of supercomputers.