Jingci Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingci Li has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jingjun Ma
Hebei Key Laboratory of Bioinorganic Chemistry, College of Sciences, Agricultural University of Hebei, Baoding 071001, China
7 shared publications Xin Du
Hebei Key Laboratory of Bioinorganic Chemistry, College of Science, Agricultural University of Hebei, Baoding 071001, Hebei Province, P. R. China
6 shared publicationsYukun Wang
Hebei Key Laboratory of Bioinorganic Chemistry, College of Sciences, Agricultural University of Hebei, Baoding 071001, China
4 shared publicationsJingwen Zhang
Agricultural University of Hebei
3 shared publicationsJing-Wen Zhang
Hebei Key Laboratory of Bioinorganic Chemistry, College of Science, Agricultural University of Hebei, Baoding, P. R. China
2 shared publicationsJingjun Ma
Agricultural University of Hebei
2 shared publications
Latest Publications
- 18 June 2012
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 59 (11) , 1468-1477
Application of Graphene as a Sorbent for Simultaneous Preconcentration and Determination of Trace Amounts of Cobalt and Nickel in Environmental Water and Vegetable Samples
A new method using a column packed with graphene as adsorbent was developed for the preconcentration of trace amounts of cobalt (Co) and nickel (Ni) prior to their determinations by flame atomic absorption spectrometry. Several factors influencing the extraction efficiency of Co and Ni and their subsequent determinations, such as pH, amounts of the chelating agent, flow rates of sample and eluent solution, eluent type and its volume, breakthrough volume, and adsorption capacity were established. Under the optimum conditions, the calibration graphs were linear in the range of 4.0‐200.0 μg L−1 and 5.0‐200.0 μg L−1 with detection limits of 0.36 μg L−1 and 0.51 μg L−1 for Co and Ni, respectively. Good relative standard deviations for ten determinations of 100.0 μg L−1 of Co and Ni were 3.2 and 3.6%, respectively. The results for determination of Co and Ni in tap water, river water, sea water, vegetable and spiked samples have demonstrated the accuracy and applicability of the proposed method. To validate the proposed method, three certified reference materials of environment water (GSBZ 50030‐94 and GSB 07‐1186‐2000) and tomato leaf (GSBZ 51001‐94) were analyzed, and the determined values were in good agreement with the certified values.
- 18 June 2012
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 59 (11) , 1468-1477
Application of Graphene as a Sorbent for Simultaneous Preconcentration and Determination of Trace Amounts of Cobalt and Nickel in Environmental Water and Vegetable Samples
A new method using a column packed with graphene as adsorbent was developed for the preconcentration of trace amounts of cobalt (Co) and nickel (Ni) prior to their determinations by flame atomic absorption spectrometry. Several factors influencing the extraction efficiency of Co and Ni and their subsequent determinations, such as pH, amounts of the chelating agent, flow rates of sample and eluent solution, eluent type and its volume, breakthrough volume, and adsorption capacity were established. Under the optimum conditions, the calibration graphs were linear in the range of 4.0‐200.0 μg L−1 and 5.0‐200.0 μg L−1 with detection limits of 0.36 μg L−1 and 0.51 μg L−1 for Co and Ni, respectively. Good relative standard deviations for ten determinations of 100.0 μg L−1 of Co and Ni were 3.2 and 3.6%, respectively. The results for determination of Co and Ni in tap water, river water, sea water, vegetable and spiked samples have demonstrated the accuracy and applicability of the proposed method. To validate the proposed method, three certified reference materials of environment water (GSBZ 50030‐94 and GSB 07‐1186‐2000) and tomato leaf (GSBZ 51001‐94) were analyzed, and the determined values were in good agreement with the certified values.
- 8 March 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 4 (4) , 1110-1116
Application of graphene as a sorbent for preconcentration and determination of trace amounts of chromium(III) in water samples by flame atomic absorption spectrometry
Graphene, a novel class of carbon nanostructure, has great promise for use as a sorbent material because of its ultrahigh specific surface area. A new method using a column packed with graphene as sorbent is developed for the preconcentration of trace amounts of chromium(III) prior to its determination by flame atomic absorption spectrometry. Some effective parameters on the extraction and complex formation were selected and optimized. The optimum experimental conditions of the proposed method were: pH, 8.0; amount of chelating agent, 2.0 mL of 0.1 mol L−1 8-hydroxyquinoline solution; eluent type and its volume, 2.0 mL of 2.0 mol L−1 nitric acid; flow rates of sample and eluent solution, 2.0 mL min−1. Under optimum conditions, an enrichment factor of 125 was obtained. The calibration graph was linear in the concentration range of 10.0–1000.0 μg L−1 with a correlation coefficient of 0.9995. The detection and quantification limits were 0.5 and 1.6 μg L−1, respectively. The relative standard deviation for ten replicate measurements were 4.3% for 20.0 μg L−1 and 3.4% for 800.0 μg L−1 of Cr(III). The proposed method was applied to tap water, sea water, and river water, and its accuracy was assessed through the analysis of certified reference water and recovery experiments. The recoveries of spiked samples were in the range of 95.7–101.2%.
- 8 March 2012
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 4 (4) , 1110-1116
Application of graphene as a sorbent for preconcentration and determination of trace amounts of chromium(III) in water samples by flame atomic absorption spectrometry
Graphene, a novel class of carbon nanostructure, has great promise for use as a sorbent material because of its ultrahigh specific surface area. A new method using a column packed with graphene as sorbent is developed for the preconcentration of trace amounts of chromium(III) prior to its determination by flame atomic absorption spectrometry. Some effective parameters on the extraction and complex formation were selected and optimized. The optimum experimental conditions of the proposed method were: pH, 8.0; amount of chelating agent, 2.0 mL of 0.1 mol L−1 8-hydroxyquinoline solution; eluent type and its volume, 2.0 mL of 2.0 mol L−1 nitric acid; flow rates of sample and eluent solution, 2.0 mL min−1. Under optimum conditions, an enrichment factor of 125 was obtained. The calibration graph was linear in the concentration range of 10.0–1000.0 μg L−1 with a correlation coefficient of 0.9995. The detection and quantification limits were 0.5 and 1.6 μg L−1, respectively. The relative standard deviation for ten replicate measurements were 4.3% for 20.0 μg L−1 and 3.4% for 800.0 μg L−1 of Cr(III). The proposed method was applied to tap water, sea water, and river water, and its accuracy was assessed through the analysis of certified reference water and recovery experiments. The recoveries of spiked samples were in the range of 95.7–101.2%.
- Retracted
- 2 February 2012
- Published by Springer Nature in Microchimica Acta
- Vol. 177 (3-4) , 497
RETRACTED ARTICLE: Application of graphene as a sorbent for the preconcentration and determination of trace amounts of lead in water samples prior to flame atomic absorption spectrometry
- 2 February 2012
- Published by Springer Nature in Microchimica Acta
- Vol. 177 (3-4) , 497
RetractedRETRACTED ARTICLE: Application of graphene as a sorbent for the preconcentration and determination of trace amounts of lead in water samples prior to flame atomic absorption spectrometry
- Open Access
- 19 December 2011
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 58 (7) , 911-918
Development of Dispersive Liquid‐Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Trace Cobalt in Water Samples
A liquid‐phase microextraction technique was developed using dispersive liquid‐liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of cobalt in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength were investigated and optimized. Under optimum conditions, an enrichment factor of 160 was obtained from 10.0 mL of water sample. The calibration graph was linearin the range of 1.15‐110 μg L−1 with a detection limit of 0.35 μg L−1. The relative standard deviation for ten replicate measurements of 10 and 100 μg L−1 of cobalt were 3.26% and 2.57%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments.
- 19 December 2011
- Published by Wiley in Journal of the Chinese Chemical Society
- Vol. 58 (7) , 911-918
Open AccessDevelopment of Dispersive Liquid‐Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Trace Cobalt in Water Samples
A liquid‐phase microextraction technique was developed using dispersive liquid‐liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of cobalt in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength were investigated and optimized. Under optimum conditions, an enrichment factor of 160 was obtained from 10.0 mL of water sample. The calibration graph was linearin the range of 1.15‐110 μg L−1 with a detection limit of 0.35 μg L−1. The relative standard deviation for ten replicate measurements of 10 and 100 μg L−1 of cobalt were 3.26% and 2.57%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments.
- 26 October 2011
- Published by Wiley in CLEAN – Soil, Air, Water
- Vol. 39 (12) , 1095-1098
Development of Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Trace Lead in Water
- 26 October 2011
- Published by Wiley in CLEAN – Soil, Air, Water
- Vol. 39 (12) , 1095-1098
Development of Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Trace Lead in Water
- 20 May 2011
- Published by Springer Nature in Biological Trace Element Research
- Vol. 144 (1-3) , 1381-1393
Development of Dispersive Liquid–Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Trace Nickel
A liquid-phase microextraction technique was developed using dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of nickel in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength, were investigated and optimized. Under optimum conditions, the calibration graph was linear in the range of 4.23–250 μg L−1 with a detection limit of 1.27 μg L−1. The relative standard deviation for ten replicate measurements of 10 and 100 μg L−1 of nickel were 3.21% and 2.55%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments.
- 20 May 2011
- Published by Springer Nature in Biological Trace Element Research
- Vol. 144 (1-3) , 1381-1393
Development of Dispersive Liquid–Liquid Microextraction Based on Solidification of Floating Organic Drop for the Determination of Trace Nickel
A liquid-phase microextraction technique was developed using dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry, for the extraction and determination of trace amounts of nickel in water samples. Microextraction efficiency factors, such as the type and volume of extraction and dispersive solvents, pH, extraction time, the chelating agent amount, and ionic strength, were investigated and optimized. Under optimum conditions, the calibration graph was linear in the range of 4.23–250 μg L−1 with a detection limit of 1.27 μg L−1. The relative standard deviation for ten replicate measurements of 10 and 100 μg L−1 of nickel were 3.21% and 2.55%, respectively. The proposed method was assessed through the analysis of certified reference water or recovery experiments.
- Open Access
- 1 March 2011
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 22 (3) , 446-453
Ultrasound-assisted emulsification solidified floating organic drop microextraction for the determination of trace cadmium in water samples by flame atomic absorption spectrometry
- 1 March 2011
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 22 (3) , 446-453
Open AccessUltrasound-assisted emulsification solidified floating organic drop microextraction for the determination of trace cadmium in water samples by flame atomic absorption spectrometry
- 1 January 2011
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 1 (5-6) , 337-348
Graphene-Based Solid-Phase Extraction for a Sensitive Determination of Trace Amounts of Lead in Water Samples
Graphene, a novel class of carbon nanostructures, has great promise for use as sorbent materials because of its ultrahigh specific surface area. A new method using a column packed with gaphene as sorbent was developed for the preconcentration of trace amounts of lead (Pb) prior to its determination by flame atomic absorption spectrometry. Some effective parameters on the extraction and complex formation were selected and optimized. Under optimum conditions, an enrichment factor of 250 was obtained. The calibration graph was linear in the concentration range of 2.4x 10.8 mol L-1-2.9x 10.6 mol L-1 with a detection limit of 1.9x 10.9 mol L-1. The relative standard deviation for ten replicate measurements of 9.7x 10.8 mol L-1 and 1.4x 10.6 mol L-1 of Pb were 3.45 %and 3.28 %, respectively. The proposed method was successfully applied in the analysis of four real environmental water samples and good spiked recoveries over the range of 95.5–99.6 %were obtained. This work not only proposes a useful method for environmental water sample pretreatment, but also reveals the great potential of gaphene as an excellent sorbent material in analytical processes.
- 1 January 2011
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 1 (5-6) , 337-348
Graphene-Based Solid-Phase Extraction for a Sensitive Determination of Trace Amounts of Lead in Water Samples
Graphene, a novel class of carbon nanostructures, has great promise for use as sorbent materials because of its ultrahigh specific surface area. A new method using a column packed with gaphene as sorbent was developed for the preconcentration of trace amounts of lead (Pb) prior to its determination by flame atomic absorption spectrometry. Some effective parameters on the extraction and complex formation were selected and optimized. Under optimum conditions, an enrichment factor of 250 was obtained. The calibration graph was linear in the concentration range of 2.4x 10.8 mol L-1-2.9x 10.6 mol L-1 with a detection limit of 1.9x 10.9 mol L-1. The relative standard deviation for ten replicate measurements of 9.7x 10.8 mol L-1 and 1.4x 10.6 mol L-1 of Pb were 3.45 %and 3.28 %, respectively. The proposed method was successfully applied in the analysis of four real environmental water samples and good spiked recoveries over the range of 95.5–99.6 %were obtained. This work not only proposes a useful method for environmental water sample pretreatment, but also reveals the great potential of gaphene as an excellent sorbent material in analytical processes.
- 1 January 2011
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 1 (4) , 287-299
Solid-Phase Extraction Clean-up Combined with Solidified Floating Organic Drop Microextraction for the Determination of Trace Manganese(II) in Different Environmental Matrices
Solid-phase extraction (SPE) clean-up combined with solidified floating organic drop microextraction (SFODME) has been developed as a new approach for the extraction and determination of trace manganese(II) in environmental water and vegetable samples. After purification of the samples by a graphene-packed SPE cartridge, SFODME technique was performed on the obtained solution. The main parameters affecting the performance of SFODME, such as type of extraction solvent as well as extraction volume, time, temperature, pH, the amount of the chelating agent, and salt effect were investigated and optimized. Under optimum conditions, a preconcentration factor of 81.0 was obtained from 7.0 mL of sample solution. The calibration graph was linear in the range from 1.90 to 400 μg/L with a detection limit of 0.57 μg/L. The relative standard deviation for ten replicate measurements of 10 and 300 μg/L of manganese(II) were 3.57 and 2.63 %, respectively. The proposed method was applied to tap, sea, river, and vegetable samples, and its accuracy was assessed through the analysis of certified reference water and recovery experiments.
- 1 January 2011
- Published by Taylor & Francis in Analytical Chemistry Letters
- Vol. 1 (4) , 287-299
Solid-Phase Extraction Clean-up Combined with Solidified Floating Organic Drop Microextraction for the Determination of Trace Manganese(II) in Different Environmental Matrices
Solid-phase extraction (SPE) clean-up combined with solidified floating organic drop microextraction (SFODME) has been developed as a new approach for the extraction and determination of trace manganese(II) in environmental water and vegetable samples. After purification of the samples by a graphene-packed SPE cartridge, SFODME technique was performed on the obtained solution. The main parameters affecting the performance of SFODME, such as type of extraction solvent as well as extraction volume, time, temperature, pH, the amount of the chelating agent, and salt effect were investigated and optimized. Under optimum conditions, a preconcentration factor of 81.0 was obtained from 7.0 mL of sample solution. The calibration graph was linear in the range from 1.90 to 400 μg/L with a detection limit of 0.57 μg/L. The relative standard deviation for ten replicate measurements of 10 and 300 μg/L of manganese(II) were 3.57 and 2.63 %, respectively. The proposed method was applied to tap, sea, river, and vegetable samples, and its accuracy was assessed through the analysis of certified reference water and recovery experiments.