KCKen S. Chen

Ken S. Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ken S. Chen has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Elucidating Liquid Water Distribution and Removal in an Operating Proton Exchange Membrane Fuel Cell via Neutron Radiography

    by Michael A. Hickner, Ken S. Chen, Nathan P. Siegel

    Neutron radiography was used to quantify the steady-state water content and its distribution in a 50 cm2 operating proton exchange membrane fuel cell. It was observed that the liquid water distribution near the corners of the gas-flow channels (GFCs) is influenced by the local gas-flow velocity as determined by the cathode stoichiometric flow ratio. At low velocity, the distribution of liquid water down the channel was found to be fairly uniform with only a slight reduction in liquid water content at the exit of the GFC corners. It was further observed that as the cathode gas-flow velocity is increased, a noticeable pattern develops in which liquid water is concentrated at the entrance to the GFC corners and becomes depleted in the corner and near the exit of the corner; liquid water content again increases further down the channel away from the corners. A single-phase computational fluid dynamics (CFD) model was developed and employed to help explain the observed water-distribution patterns. Flow-fields computed from our CFD model reveal recirculation regions in the GFC corners as well as in the areas of increased local gas-flow velocity, which help explain the experimentally observed liquid water distribution.


  • Simplified models for predicting the onset of liquid water droplet instability at the gas diffusion layer/gas flow channel interface

    by Ken S. Chen, Michael A. Hickner, David R. Noble

    Simplified models that are based on macroscopic force balances and droplet-geometry approximations are presented for predicting the onset of instability leading to removal of water droplets at the gas diffusion layer (GDL)/gas flow channel (GFC) interface. Visualization experiments are carried out to observe the formation, growth, and removal or instability of the water droplets at the GDL/GFC interface of a simulated polymer electrolyte fuel cell cathode. Droplet-instability diagrams or ‘windows’ computed by the simplified models are compared with those measured experimentally, and good agreement is obtained. Two-dimensional flow simulations employing the finite element method coupled with an arbitrary Lagrangian–Eulerian formulation for determining the liquid/gas interface position are also performed to assess the simplified cylindrical-droplet model. Necessary conditions for preventing fully grown droplets from lodging in the flow channel are derived using the simplified models. It is found that droplet removal can be enhanced by increasing flow channel length or mean gas flow velocity, decreasing channel height or contact angle hysteresis, or making the GDL/GFC interface more hydrophobic. Copyright © 2005 John Wiley & Sons, Ltd.