Julien Favre
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Julien Favre has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Kamiar Aminian
Laboratory of Movement Analysis and Measurement, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
7 shared publications B.M. Jolles
3 shared publications- Hossein Rouhani
Department of Mechanical Engineering, University of Alberta, Edmonton, Alberta, Canada
2 shared publications R. Aissaoui
2 shared publications- Xavier Crevoisier
Centre Hospitalier Universitaire Vaudois (CHUV) and University of Lausanne (UNIL), Department of Orthopaedic Surgery and Traumatology, Pierre-Decker 4, CH-1011 Lausanne, Switzerland
2 shared publications B. M. Jolles
University Hospital of Lausanne (CHUV) Orthopaedic Hospital (HOSR) 1005 Lausanne Switzerland
1 shared publication
Latest Publications
- 1 May 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (7) , 1704-1711
A wearable system for multi-segment foot kinetics measurement
- 1 May 2014
- Published by Elsevier in Journal of Biomechanics
- Vol. 47 (7) , 1704-1711
A wearable system for multi-segment foot kinetics measurement
- 1 June 2012
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 134 (6) , 061006
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.
- 1 June 2012
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 134 (6) , 061006
Measurement of Multi-segment Foot Joint Angles During Gait Using a Wearable System
Usually the measurement of multi-segment foot and ankle complex kinematics is done with stationary motion capture devices which are limited to use in a gait laboratory. This study aimed to propose and validate a wearable system to measure the foot and ankle complex joint angles during gait in daily conditions, and then to investigate its suitability for clinical evaluations. The foot and ankle complex consisted of four segments (shank, hindfoot, forefoot, and toes), with an inertial measurement unit (3D gyroscopes and 3D accelerometers) attached to each segment. The angles between the four segments were calculated in the sagittal, coronal, and transverse planes using a new algorithm combining strap-down integration and detection of low-acceleration instants. To validate the joint angles measured by the wearable system, three subjects walked on a treadmill for five minutes at three different speeds. A camera-based stationary system that used a cluster of markers on each segment was used as a reference. To test the suitability of the system for clinical evaluation, the joint angle ranges were compared between a group of 10 healthy subjects and a group of 12 patients with ankle osteoarthritis, during two 50-m walking trials where the wearable system was attached to each subject. On average, over all joints and walking speeds, the RMS differences and correlation coefficients between the angular curves obtained using the wearable system and the stationary system were 1 deg and 0.93, respectively. Moreover, this system was able to detect significant alteration of foot and ankle function between the group of patients with ankle osteoarthritis and the group of healthy subjects. In conclusion, this wearable system was accurate and suitable for clinical evaluation when used to measure the multi-segment foot and ankle complex kinematics during long-distance walks in daily life conditions.
- 10 August 2010
- Published by Elsevier in Journal of Biomechanics
- Vol. 43 (11) , 2196-2202
Evaluation of a mixed approach combining stationary and wearable systems to monitor gait over long distance
- 10 August 2010
- Published by Elsevier in Journal of Biomechanics
- Vol. 43 (11) , 2196-2202
Evaluation of a mixed approach combining stationary and wearable systems to monitor gait over long distance
- 1 October 2009
- Published by Elsevier in Journal of Biomechanics
- Vol. 42 (14) , 2330-2335
Functional calibration procedure for 3D knee joint angle description using inertial sensors
- 1 October 2009
- Published by Elsevier in Journal of Biomechanics
- Vol. 42 (14) , 2330-2335
Functional calibration procedure for 3D knee joint angle description using inertial sensors
- 1 January 2008
- Published by Elsevier in Journal of Biomechanics
- Vol. 41 (5) , 1029-1035
Ambulatory measurement of 3D knee joint angle
- 1 January 2008
- Published by Elsevier in Journal of Biomechanics
- Vol. 41 (5) , 1029-1035
Ambulatory measurement of 3D knee joint angle
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 3938-3941
An Orientation Measuring System Suitable for Routine Uses Made by the Fusion of a 3D Gyroscope and a Magnetic Tracker
Many studies have shown the efficacy of orientation and three-dimensional joint angle measurement for patient evaluation or rehabilitation purposes. But currently, the use of these systems for routine practice is questionable. The commercially available devices are generally too expensive and complicated-to-use. This study proposed the fusion between two affordable types of orientation measuring systems, which used separately couldn't satisfy the health professionals' needs. One was a portable magnetic tracker limited in accuracy, sampling frequency and possibly distorted. The other was triplets of gyroscopes limited by their bias, which generates orientation drift after integration. The fusion algorithm presented here relay on two cascaded complementary Kalman filters to estimate the bias of the gyroscopes and to provide accurate and high frequency orientation even during distortion periods. This system was assessed during treadmill walking and reported good performances.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 3938-3941
An Orientation Measuring System Suitable for Routine Uses Made by the Fusion of a 3D Gyroscope and a Magnetic Tracker
Many studies have shown the efficacy of orientation and three-dimensional joint angle measurement for patient evaluation or rehabilitation purposes. But currently, the use of these systems for routine practice is questionable. The commercially available devices are generally too expensive and complicated-to-use. This study proposed the fusion between two affordable types of orientation measuring systems, which used separately couldn't satisfy the health professionals' needs. One was a portable magnetic tracker limited in accuracy, sampling frequency and possibly distorted. The other was triplets of gyroscopes limited by their bias, which generates orientation drift after integration. The fusion algorithm presented here relay on two cascaded complementary Kalman filters to estimate the bias of the gyroscopes and to provide accurate and high frequency orientation even during distortion periods. This system was assessed during treadmill walking and reported good performances.
- 19 January 2006
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (7) , 592-604
A new ambulatory system for comparative evaluation of the three‐dimensional knee kinematics, applied to anterior cruciate ligament injuries
The aim of this study was to develop an ambulatory system for the three‐dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long‐term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL‐deficient men (range: 19–36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4°, 2.7° and 4.2° for flexion–extension, internal–external rotation, and abduction–adduction, respectively. The repeatability of the results for the three directions was 0.8°, 0.7° and 1.8°. The averaged ROM of the five patients’ healthy knee were 70.1° [standard deviation (SD) 5.8°], 24.0° (SD 3.0°) and 12.0° (SD 6.3°) for flexion–extension, internal–external rotation and abduction–adduction before surgery, and 76.5° (SD 4.1°), 21.7° (SD 4.9°) and 10.2° (SD 4.6°) 1 year following the reconstruction. The results for the pathologic knee were 64.5° (SD 6.9°), 20.6° (SD 4.0°) and 19.7° (8.2°) during the first evaluation, and 72.3° (SD 2.4°), 25.8° (SD 6.4°) and 12.4° (SD 2.3°) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion–extension and internal–external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion–extension ROM and higher internal–external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery.
- 19 January 2006
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 14 (7) , 592-604
A new ambulatory system for comparative evaluation of the three‐dimensional knee kinematics, applied to anterior cruciate ligament injuries
The aim of this study was to develop an ambulatory system for the three‐dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long‐term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL‐deficient men (range: 19–36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4°, 2.7° and 4.2° for flexion–extension, internal–external rotation, and abduction–adduction, respectively. The repeatability of the results for the three directions was 0.8°, 0.7° and 1.8°. The averaged ROM of the five patients’ healthy knee were 70.1° [standard deviation (SD) 5.8°], 24.0° (SD 3.0°) and 12.0° (SD 6.3°) for flexion–extension, internal–external rotation and abduction–adduction before surgery, and 76.5° (SD 4.1°), 21.7° (SD 4.9°) and 10.2° (SD 4.6°) 1 year following the reconstruction. The results for the pathologic knee were 64.5° (SD 6.9°), 20.6° (SD 4.0°) and 19.7° (8.2°) during the first evaluation, and 72.3° (SD 2.4°), 25.8° (SD 6.4°) and 12.4° (SD 2.3°) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion–extension and internal–external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion–extension ROM and higher internal–external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery.