Nathan Efron
Research Subjects
Research Interests
Nathan Efron has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Philip B. Morgan
The University of Manchester
5 shared publications Ritu Jagpal
Eurolens Research, Department of Optometry and Neuroscience, UMIST, Manchester, UK
2 shared publicationsAndrew B Tullo
Department of Ophthalmology The University of Manchester Manchester United Kingdom
1 shared publication- Craig A. Woods
School of Optometry and Vision Science, University of New South Wales, Sydney, Australia; ZEISS Vision Care, Carl Zeiss Vision International GmbH, Aalen, Germany
1 shared publication Craig Farmer
School of Optometry, Queensland University of Technology, Victoria Park Road, Kelvin Grove, Queensland 4059, Australia
1 shared publicationElizabeth A Hill
Eurolens Research The University of Manchester Manchester United Kingdom
1 shared publication
Latest Publications
- 1 June 2005
- Published by Wiley in Optometry and Vision Science
- Vol. 82 (6) , 519-527
The Size, Location, and Clinical Severity of Corneal Infiltrative Events Associated With Contact Lens Wear
Purpose.: The purpose of this study is to determine the relationship between the size, location, and clinical severity of corneal infiltrative events (CIEs) associated with contact lens wear. Methods.: We examined a series of contact lens wearers, presenting consecutively to a large hospital clinic, who had any form of CIE. The severity of the CIE was quantified using a clinical severity matrix based on scores attributed to each of 10 signs and symptoms. The infiltrate was accurately drawn on a schematic diagram of the ocular surface, and from this, we determined its size (i.e., largest dimension) and distance from the limbus. Cartograms were constructed to illustrate the size and location of the corneal infiltrates according to wearing modality and lens type. Results.: Useable data pertaining to 111 patients were analyzed. A significant positive correlation was found between the distance of the infiltrate from the limbus versus clinical severity (p = 0.002), but not between the distance of the infiltrate from the limbus versus infiltrate size (p = 0.97). The cartograms revealed a tendency for infiltrates to occur in the superior cornea of patients wearing extended wear silicone hydrogel lenses (p = 0.0002) in the central cornea of patients wearing daily wear hydrogel daily disposable lenses (p = 0.007) and in the peripheral cornea of patients wearing daily wear hydrogel (excluding daily disposable) lenses (p = 0.0006). Conclusions.: These data statistically validate the previously held anecdotal notion that CIEs which occur in the peripheral cornea are less clinically severe than those which occur in the central cornea. Consideration of the distribution of CIEs may facilitate a better understanding of the etiology of these events and can serve to alert practitioners as to their likely clinical presentation.
- 1 June 2005
- Published by Wiley in Optometry and Vision Science
- Vol. 82 (6) , 519-527
The Size, Location, and Clinical Severity of Corneal Infiltrative Events Associated With Contact Lens Wear
Purpose.: The purpose of this study is to determine the relationship between the size, location, and clinical severity of corneal infiltrative events (CIEs) associated with contact lens wear. Methods.: We examined a series of contact lens wearers, presenting consecutively to a large hospital clinic, who had any form of CIE. The severity of the CIE was quantified using a clinical severity matrix based on scores attributed to each of 10 signs and symptoms. The infiltrate was accurately drawn on a schematic diagram of the ocular surface, and from this, we determined its size (i.e., largest dimension) and distance from the limbus. Cartograms were constructed to illustrate the size and location of the corneal infiltrates according to wearing modality and lens type. Results.: Useable data pertaining to 111 patients were analyzed. A significant positive correlation was found between the distance of the infiltrate from the limbus versus clinical severity (p = 0.002), but not between the distance of the infiltrate from the limbus versus infiltrate size (p = 0.97). The cartograms revealed a tendency for infiltrates to occur in the superior cornea of patients wearing extended wear silicone hydrogel lenses (p = 0.0002) in the central cornea of patients wearing daily wear hydrogel daily disposable lenses (p = 0.007) and in the peripheral cornea of patients wearing daily wear hydrogel (excluding daily disposable) lenses (p = 0.0006). Conclusions.: These data statistically validate the previously held anecdotal notion that CIEs which occur in the peripheral cornea are less clinically severe than those which occur in the central cornea. Consideration of the distribution of CIEs may facilitate a better understanding of the etiology of these events and can serve to alert practitioners as to their likely clinical presentation.
- 14 March 2003
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 23 (2) , 119-124
Experience and training as determinants of grading reliability when assessing the severity of contact lens complications
Purpose: A study was conducted to investigate the influence of experience and training on grading reliability when assessing the severity of contact lens complications. Methods: Twenty‐three optometry students who were unfamiliar with the use of grading scales each used the Efron Grading Tutor computer program to ascertain grading reliability at an ‘initial’ experimental session and a ‘final’ session 3 weeks later. Twelve subjects (the ‘trained’ group) were given a tutorial on grading techniques and were asked to complete two grading exercises between the initial and final sessions. The other 11 subjects (the ‘untrained’ group) received no such training between the two sessions. Differences in grading reliability between the initial and final grading sessions were evaluated. Results: Grading reliability was superior (lower) for the combined subject cohort at the final session (mean ± standard deviation 0.33 ± 0.12) compared with the initial session (0.46 ± 0.25) ( p = 0.004). However, there was no difference in the improvement in grading reliability between the two groups. Conclusions: Grading reliability improves statistically with some experience, although perhaps not to a clinically meaningful extent. No added benefit can be derived from supplemental training.
- 14 March 2003
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 23 (2) , 119-124
Experience and training as determinants of grading reliability when assessing the severity of contact lens complications
Purpose: A study was conducted to investigate the influence of experience and training on grading reliability when assessing the severity of contact lens complications. Methods: Twenty‐three optometry students who were unfamiliar with the use of grading scales each used the Efron Grading Tutor computer program to ascertain grading reliability at an ‘initial’ experimental session and a ‘final’ session 3 weeks later. Twelve subjects (the ‘trained’ group) were given a tutorial on grading techniques and were asked to complete two grading exercises between the initial and final sessions. The other 11 subjects (the ‘untrained’ group) received no such training between the two sessions. Differences in grading reliability between the initial and final grading sessions were evaluated. Results: Grading reliability was superior (lower) for the combined subject cohort at the final session (mean ± standard deviation 0.33 ± 0.12) compared with the initial session (0.46 ± 0.25) ( p = 0.004). However, there was no difference in the improvement in grading reliability between the two groups. Conclusions: Grading reliability improves statistically with some experience, although perhaps not to a clinically meaningful extent. No added benefit can be derived from supplemental training.
- 14 January 2003
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 23 (1) , 79-85
The combined influence of knowledge, training and experience when grading contact lens complications
Purpose: A study was conducted to evaluate the influence of knowledge, training and experience (clinical skills set) when assessing the severity of contact lens complications. Methods: Nine optometrists (who were in possession of a relevant clinical skills set) and nine ‘non‐optometrists’ (subjects without the clinical skills set) were each invited to grade – to the nearest 0.1 increment – an image of each of 16 contact lens complications using Efron Grading Scales for Contact Lens Complications. This procedure was repeated 2 weeks later, yielding a total data base comprising 576 individual grading estimates. Results: The mean of the test and retest grading estimates was the same for the optometrists (2.8 ± 0.7) and the non‐optometrists (2.6 ± 0.9) ( F 1,15,1 = 1.3, p = 0.26); that is, non‐optometrists can grade accurately. Median grading reliability for optometrists (±0.41) was lower than (i.e. superior to) that for non‐optometrists (±0.67) ( p = 0.001). Non‐optometrists tended to display a reluctance to grade by interpolation and to less reliably grade subtle clinical signs. Conclusions: When averaged over several attempts, non‐optometrists will arrive at similar estimates of severity to optometrists when grading ocular complications of contact lens wear; however, they will do so less reliably. The relative contribution of the three attributes of the clinical skills set to grading performance is presently unclear.
- 14 January 2003
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 23 (1) , 79-85
The combined influence of knowledge, training and experience when grading contact lens complications
Purpose: A study was conducted to evaluate the influence of knowledge, training and experience (clinical skills set) when assessing the severity of contact lens complications. Methods: Nine optometrists (who were in possession of a relevant clinical skills set) and nine ‘non‐optometrists’ (subjects without the clinical skills set) were each invited to grade – to the nearest 0.1 increment – an image of each of 16 contact lens complications using Efron Grading Scales for Contact Lens Complications. This procedure was repeated 2 weeks later, yielding a total data base comprising 576 individual grading estimates. Results: The mean of the test and retest grading estimates was the same for the optometrists (2.8 ± 0.7) and the non‐optometrists (2.6 ± 0.9) ( F 1,15,1 = 1.3, p = 0.26); that is, non‐optometrists can grade accurately. Median grading reliability for optometrists (±0.41) was lower than (i.e. superior to) that for non‐optometrists (±0.67) ( p = 0.001). Non‐optometrists tended to display a reluctance to grade by interpolation and to less reliably grade subtle clinical signs. Conclusions: When averaged over several attempts, non‐optometrists will arrive at similar estimates of severity to optometrists when grading ocular complications of contact lens wear; however, they will do so less reliably. The relative contribution of the three attributes of the clinical skills set to grading performance is presently unclear.
- 1 January 2003
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 29 (1) , S122-S126
The Case Against Rigid Contact Lenses
Rigid lens fitting has been an integral part of contact lens practice for decades. However, rigid lens fitting has been constantly declining since soft lenses were introduced in the 1970s to whereby, world wide, rigid lenses constitute less than 10% of new contact lens fits. It seems that many practitioners correctly or incorrectly believe that rigid lenses only need to be prescribed in specialized or extenuating circumstances. This discussion article examines the international decline in rigid lens fitting and seeks to explain the cause of this trend. I conclude that rigid lenses will be virtually obsolete by the year 2010.
- 1 January 2003
- Published by Wolters Kluwer Health in Eye & Contact Lens: Science & Clinical Practice
- Vol. 29 (1) , S122-S126
The Case Against Rigid Contact Lenses
Rigid lens fitting has been an integral part of contact lens practice for decades. However, rigid lens fitting has been constantly declining since soft lenses were introduced in the 1970s to whereby, world wide, rigid lenses constitute less than 10% of new contact lens fits. It seems that many practitioners correctly or incorrectly believe that rigid lenses only need to be prescribed in specialized or extenuating circumstances. This discussion article examines the international decline in rigid lens fitting and seeks to explain the cause of this trend. I conclude that rigid lenses will be virtually obsolete by the year 2010.
- 25 June 2002
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 22 (4) , 341-349
Validation of computer morphs for grading contact lens complications
An alternative to the use of printed grading scales for assessing the severity of contact lens‐induced ocular pathology is to use computer‐generated grading morphs. This technique involves manipulation of a continuously variable movie sequence until this matches the severity of the condition being observed. To validate the use of computer morphs, nine experienced optometrists were each invited to grade – to the nearest 0.1 increment – an image of each of 16 contact lens complications, using printed scales (Efron Grading Scales for Contact Lens Complications) and computer morphs (Efron Grading Morphs). This entire procedure was repeated approximately 2 weeks later, yielding a total data base comprising of 576 individual grading estimates. Good accuracy was achieved using computer morphs, as evidenced by the similarity between the mean of the test and retest grading estimates for the printed scales (2.8 ± 0.7) and the computer morphs (2.6 ± 0.8) ( F 1,8 =2.7, p =0.14). There was no difference in median reliability between the printed scales (±0.41) and the computer morphs (±0.43) ( Z =0.1, p =0.95). Computer morphs are thus considered to have been validated in view of their accuracy and reliability compared with printed scales. In addition, computer morphs offer considerable utility in terms of computer‐based clinical record keeping, teaching and learning, and clinical research.
- 25 June 2002
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 22 (4) , 341-349
Validation of computer morphs for grading contact lens complications
An alternative to the use of printed grading scales for assessing the severity of contact lens‐induced ocular pathology is to use computer‐generated grading morphs. This technique involves manipulation of a continuously variable movie sequence until this matches the severity of the condition being observed. To validate the use of computer morphs, nine experienced optometrists were each invited to grade – to the nearest 0.1 increment – an image of each of 16 contact lens complications, using printed scales (Efron Grading Scales for Contact Lens Complications) and computer morphs (Efron Grading Morphs). This entire procedure was repeated approximately 2 weeks later, yielding a total data base comprising of 576 individual grading estimates. Good accuracy was achieved using computer morphs, as evidenced by the similarity between the mean of the test and retest grading estimates for the printed scales (2.8 ± 0.7) and the computer morphs (2.6 ± 0.8) ( F 1,8 =2.7, p =0.14). There was no difference in median reliability between the printed scales (±0.41) and the computer morphs (±0.43) ( Z =0.1, p =0.95). Computer morphs are thus considered to have been validated in view of their accuracy and reliability compared with printed scales. In addition, computer morphs offer considerable utility in terms of computer‐based clinical record keeping, teaching and learning, and clinical research.
- 1 January 2001
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 21 (1) , 17-29
Validation of grading scales for contact lens complications
Summary: The validity of use of two artist‐rendered and two photographic sets of grading scales (grading ‘systems’) designed for gauging the severity of contact lens‐related ocular pathology was assessed in terms of precision and reliability. Thirteen observers each graded 30 images — by interpolation or extrapolation to the nearest 0.1 increment — of each of the three contact lens complications (corneal staining, conjunctival redness and papillary conjunctivitis) that were common to all four grading systems. This entire procedure was repeated approximately two weeks later, yielding a total data base comprising of 9360 individual grading estimates. Analysis of variance revealed statistically significant differences in both precision and reliability between systems, observers and conditions ( p p =0.0001 for all other combinations). The artist‐rendered systems generally afforded lower grading estimates and better grading reliability than the photographic systems. Corneal staining could be graded less reliably than conjunctival redness and papillary conjunctivitis. Grading reliability was generally unaffected by the severity of the condition being assessed. Notwithstanding the above differences, all four grading systems are validated for clinical use and practitioners can initially expect to use these systems with average 95% confidence limits of ±1.2 grading scale units (observer range ±0.7 to ±2.5 grading scale units). In view of the significant between‐system differences revealed in this study, it is advisable to consistently use the same grading system. It may be possible to reduce between‐observer differences by applying personalised correction factors to normalise grading estimates.
- 1 January 2001
- Published by Springer Nature in Ophthalmic and Physiological Optics
- Vol. 21 (1) , 17-29
Validation of grading scales for contact lens complications
Summary: The validity of use of two artist‐rendered and two photographic sets of grading scales (grading ‘systems’) designed for gauging the severity of contact lens‐related ocular pathology was assessed in terms of precision and reliability. Thirteen observers each graded 30 images — by interpolation or extrapolation to the nearest 0.1 increment — of each of the three contact lens complications (corneal staining, conjunctival redness and papillary conjunctivitis) that were common to all four grading systems. This entire procedure was repeated approximately two weeks later, yielding a total data base comprising of 9360 individual grading estimates. Analysis of variance revealed statistically significant differences in both precision and reliability between systems, observers and conditions ( p p =0.0001 for all other combinations). The artist‐rendered systems generally afforded lower grading estimates and better grading reliability than the photographic systems. Corneal staining could be graded less reliably than conjunctival redness and papillary conjunctivitis. Grading reliability was generally unaffected by the severity of the condition being assessed. Notwithstanding the above differences, all four grading systems are validated for clinical use and practitioners can initially expect to use these systems with average 95% confidence limits of ±1.2 grading scale units (observer range ±0.7 to ±2.5 grading scale units). In view of the significant between‐system differences revealed in this study, it is advisable to consistently use the same grading system. It may be possible to reduce between‐observer differences by applying personalised correction factors to normalise grading estimates.
- 1 April 2000
- Vol. 26 (2) , 85-90
Hydrogel contact lens ageing.
To determine if hydrogel lens water content decreases over wearing periods of up to four weeks; that is, demonstrate an 'ageing' effect. Six subjects (4 males, 2 females; age range: 34.8 +/- 11.0 years) wore each of the following lenses for one month: Acuvue, Frequency 38, Gentle Touch and Proclear. Pre-insertion and post-removal lens water content was measured daily by the subjects using an Atago CL-1 Soft Contact Lens Refractometer for a 28 day period. Post-insertion and pre-removal comfort was recorded over the same period. A significant lens ageing effect was noted whereby the pre-insertion lens water content decreased significantly over the 28 day cycle for all lenses (P < 0.05). The pattern for daily dehydration remained consistent for the 28 day period for the Acuvue lens and the Gentle Touch lens but decreased for the Frequency 38 lens and the Proclear lens. Comfort decreased significantly by the end of the day for three of the four lens types investigated. It is apparent that the extent of lens dehydration changes over time, and that this pattern of change is different for different lens types. The associated loss of oxygen performance with dehydration is demonstrated. These data will assist practitioners in understanding the clinical effects of soft lens dehydration over time.
- 1 April 2000
- Vol. 26 (2) , 85-90
Hydrogel contact lens ageing.
To determine if hydrogel lens water content decreases over wearing periods of up to four weeks; that is, demonstrate an 'ageing' effect. Six subjects (4 males, 2 females; age range: 34.8 +/- 11.0 years) wore each of the following lenses for one month: Acuvue, Frequency 38, Gentle Touch and Proclear. Pre-insertion and post-removal lens water content was measured daily by the subjects using an Atago CL-1 Soft Contact Lens Refractometer for a 28 day period. Post-insertion and pre-removal comfort was recorded over the same period. A significant lens ageing effect was noted whereby the pre-insertion lens water content decreased significantly over the 28 day cycle for all lenses (P < 0.05). The pattern for daily dehydration remained consistent for the 28 day period for the Acuvue lens and the Gentle Touch lens but decreased for the Frequency 38 lens and the Proclear lens. Comfort decreased significantly by the end of the day for three of the four lens types investigated. It is apparent that the extent of lens dehydration changes over time, and that this pattern of change is different for different lens types. The associated loss of oxygen performance with dehydration is demonstrated. These data will assist practitioners in understanding the clinical effects of soft lens dehydration over time.
- 1 July 1999
- Vol. 25 (3) , 148-51
Hydrogel contact lens dehydration and oxygen transmissibility.
Oxygen transmissibility is a key determinant of the physiological response of the cornea to contact lens wear. Because transmissibility is related to hydrogel water content, we conducted a study to determine the change in water content during lens wear and to quantify the impact any such change would have on transmissibility. In a double masked clinical investigation, two subjects each wore 17 different pairs of contact lenses. Water content was measured before lens wear at 35 degrees C and immediately after 4 hours of contact lens wear. Contact lens oxygen transmissibilities were calculated on each occasion. The absolute changes in water content for the 17 lenses varied from +0.5% to -5.3%. For some lenses, this change in water content altered the lens oxygen transmissibilities to a clinically significant degree. The changes in water content and oxygen transmissibilities were greatest with FDA Group IV lenses. Dehydration during contact lens wear can alter the oxygen transmissibility of hydrogel lenses, and in some situations, this factor may be clinically significant.
- 1 July 1999
- Vol. 25 (3) , 148-51
Hydrogel contact lens dehydration and oxygen transmissibility.
Oxygen transmissibility is a key determinant of the physiological response of the cornea to contact lens wear. Because transmissibility is related to hydrogel water content, we conducted a study to determine the change in water content during lens wear and to quantify the impact any such change would have on transmissibility. In a double masked clinical investigation, two subjects each wore 17 different pairs of contact lenses. Water content was measured before lens wear at 35 degrees C and immediately after 4 hours of contact lens wear. Contact lens oxygen transmissibilities were calculated on each occasion. The absolute changes in water content for the 17 lenses varied from +0.5% to -5.3%. For some lenses, this change in water content altered the lens oxygen transmissibilities to a clinically significant degree. The changes in water content and oxygen transmissibilities were greatest with FDA Group IV lenses. Dehydration during contact lens wear can alter the oxygen transmissibility of hydrogel lenses, and in some situations, this factor may be clinically significant.
- 1 January 1999
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 22 (1) , 14-18
The parameter stability of a high dk rigid lens material
- 1 January 1999
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 22 (1) , 14-18
The parameter stability of a high dk rigid lens material
- 1 March 1983
- Vol. 54 (3) , 229-34
Effect of blinking on the level of oxygen beneath hard and soft gas-permeable contact lenses.
The oxygen tension, which can also be stated as the equivalent oxygen percentage (EOP), was measured beneath a variety of hard and soft gas-permeable contact lenses following static and dynamic wearing conditions. The significant increases in EOP beneath rigid lenses upon blinking were to be expected in view of the tear pumping mechanisms known to exist with such lenses. However, blinking was found to have a minimal effect on the EOP beneath hydrogen lenses, confirming earlier predictions.
- 1 March 1983
- Vol. 54 (3) , 229-34
Effect of blinking on the level of oxygen beneath hard and soft gas-permeable contact lenses.
The oxygen tension, which can also be stated as the equivalent oxygen percentage (EOP), was measured beneath a variety of hard and soft gas-permeable contact lenses following static and dynamic wearing conditions. The significant increases in EOP beneath rigid lenses upon blinking were to be expected in view of the tear pumping mechanisms known to exist with such lenses. However, blinking was found to have a minimal effect on the EOP beneath hydrogen lenses, confirming earlier predictions.