BBBob van Den Bergen

Bob van Den Bergen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bob van Den Bergen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Alexander J.E. Raaijmakers

    University Medical Centre Utrecht, Department of Radiotherapy, Utrecht, the Netherlands

    1 shared publication
  • Catalina Arteaga de Castro

    University Medical Centre Utrecht, Department of Radiology, Utrecht, the Netherlands

    1 shared publication
  • Cássio van Den Berg

    Computational Imaging Group for MRI Therapy & Diagnostics, Department of Radiotherapy University Medical Center Utrecht Utrecht The Netherlands

    1 shared publication
  • Dennis W.J. Klomp

    University Medical Centre Utrecht, Department of Radiology, Utrecht, the Netherlands

    1 shared publication
  • Hugo Kroeze

    University Medical Centre Utrecht, Department of Radiology, Utrecht, the Netherlands

    1 shared publication
  • Jan J.W. Lagendijk

    University Medical Centre Utrecht, Department of Radiotherapy, Utrecht, the Netherlands

    1 shared publication

Latest Publications

  • Uniform prostate imaging and spectroscopy at 7 T: comparison between a microstrip array and an endorectal coil

    by Bob van Den Bergen, Dennis W.J. Klomp, Alexander J.E. Raaijmakers, Catalina Arteaga de Castro, Vincent O. Boer, Hugo Kroeze, Peter R. Luijten, Jan J.W. Lagendijk, Cornelis A. T. van Den Berg

    An endorectal coil and an eight‐element microstrip array were compared for prostate imaging at 7 T. An extensive radiofrequency safety assessment was performed with the use of finite difference time domain simulations to determine safe scan parameters. These simulations showed that the endorectal coil can deliver substantially more B to the prostate than can the microstrip array within the specific absorption rate safety guidelines. However, the B field of the endorectal coil is very inhomogeneous, which makes the use of adiabatic pulses compulsory for T1‐ or T2‐weighted imaging. As a consequence, a full prostate examination is only possible in a feasible amount of time when the microstrip array is used for T1‐ and T2‐weighted imaging, whereas the endorectal coil is required for spectroscopic imaging. The pulse parameters were optimised within the specific absorption rate guidelines and thereafter used to provide a good illustration of the possibilities of prostate imaging at 7 T. Copyright © 2010 John Wiley & Sons, Ltd.