  • The Mean Prehospital Machine; accurate prehospital non-invasive blood pressure measurement in the critically ill patient

    by Sandy Muecke, Andrew Bersten, John Plummer

    Non-invasive blood pressure recordings may be inaccurate in the critically ill patient and measurement difficulties are intensified in the prehospital setting. This may adversely impact upon outcomes for many critically ill patients, particularly those with traumatic brain injury and/or lengthy prehospital times. This study aimed to validate a non-invasive, oscillometric, ambulatory blood pressure measuring device, the Oscar 2, Model 222 (SunTech Medical, Morrisville, USA) during the ambulance transport of critically ill patients. We have previously shown that mean arterial blood pressures observed by Intensive Care Unit nurses from a patient monitor can be considered interchangeable with reference intra-arterial integrated mean pressures. In the current study, we compared non-invasive device mean pressures to intra-arterial pressures observed by retrieval nurses from the patient monitor, during the ambulance transportation of critically ill patients. Device performance was required to fulfil the Association for the Advancement of Medical Instrumentation (AAMI) protocol requirements. Additionally, linear mixed effects analyses and Bland–Altman comparisons were undertaken. For 157 measurements recorded from 23 patients, when the Oscar 2 did not indicate a measurement was associated with a fault, the device fulfilled the AAMI protocol requirements, with a mean error of −1.1 mmHg (standard deviation 7.8 mmHg), 95% confidence intervals (linear mixed effects analysis) −2.9, 0.8; P = 0.26. Bland–Altman plots indicated uniform agreement across a wide range of blood pressures. Sixteen percent of recordings were associated with a patient, environment, or device generated fault. When the Oscar 2 does not indicate a fault has occurred, clinicians may be confident the mean pressure, within acceptable limits, is accurate, even during ambulance motion, administration of high doses of vasopressors and mechanical ventilation. The Oscar 2 appears to be an accurate and rugged out-of-hospital device.


  • Validation of arterial blood pressures observed from the patient monitor; a tool for prehospital research

    by Sandy Muecke, Andrew Bersten, John Plummer

    For some time, the inaccuracies of non-invasive blood pressure measurement in critically ill patients have been recognised. Measurement difficulties can occur even in optimal conditions, but in prehospital transportation vehicles, problems are exacerbated. Intra-arterial pressures must be used as the reference against which to compare the performance of non-invasive methods in the critically ill patient population. Intra-arterial manometer data observed from the patient monitor has frequently been used as the reference against which to assess the accuracy of noninvasive devices in the emergency setting. To test this method’s validity, this study aimed to determine whether numerical monitor pressures can be considered interchangeable with independently sampled intra-arterial pressures. Intensive Care Unit nurses were asked to document arterial systolic, diastolic and mean pressures numerically displayed on the patient monitor. Observed pressures were compared to reference intra-arterial pressures independently recorded to a computer following analogue to digital conversion. Differences between observed and recorded pressures were evaluated using the Association for the Advancement of Medical Instrumentation (AAMI) protocol. Additionally, two-level linear mixed effects analyses and Bland-Altman comparisons were undertaken. Systolic, diastolic and integrated mean pressures observed during 60 data collection sessions (n = 600) fulfilled AAMI protocol criteria. Integrated mean pressures were the most robust. For these pressures, mean error (reference minus observed) was 0.5 mm Hg (SD 1.4 mm Hg); 95% CI (two-level linear mixed effects analysis) 0.4–0.6 mm Hg; P < 0.001. Bland-Altman plots demonstrated tight 95% limits of agreement (−2.3 to 3.2 mm Hg), and uniform agreement across the range of mean blood pressures. Integrated mean arterial pressures observed from a well maintained patient monitor can be considered interchangeable with independently sampled intra-arterial pressures and may be confidently used as the reference against which to test the accuracy of non-invasive blood pressure measuring methods in the prehospital or emergency setting.


  • Open Access

    Bereavement help-seeking following an 'expected' death: a cross-sectional randomised face-to-face population survey

    by David C Currow, Katrina Allen, John Plummer, Samar Aoun, Meg Hegarty, Amy P Abernethy

    BACKGROUND: This study examines the prevalence and nature of bereavement help-seeking among the population who experienced an "expected" death in the five years before their survey response. Such whole population data are not limited by identification through previous access to specific services nor practitioners. METHODS: In a randomised, cross-sectional, state-wide population-based survey, 6034 people over two years completed face-to-face interviews in South Australia by trained interviewers using piloted questions (74.2% participation rate). Respondent demographics, type of grief help sought, and circumstantial characteristics were collected. Uni- and multi-variate logistic regression models were created. RESULTS: One in three people (1965/6034) had experienced an 'expected' death of someone close to them in the last five years. Thirteen per cent sought help for their grief from one or more: friend/family members (10.7%); grief counselors (2.2%); spiritual advisers (1.9%); nurses/doctors (1.5%). Twenty five respondents (1.3%) had not sought, but would have valued help with their grief. In multi-variate regression modeling, those who sought professional help (3.4% of the bereaved) had provided more intense care (OR 5.39; CI 1.94 to14.98; p 2 = 0.33). CONCLUSION: These data provide a whole-of-population baseline of bereavement help-seeking. The uniquely identified group who wished they had sought help is one where potentially significant health gains could be made as we seek to understand better any improved health outcomes as a result of involving bereavement services.


  • Learning Endotracheal Intubation in a Clinical Skills Learning Center: A Quantitative Study

    by John L. Plummer, Harry Owen

    This study aimed to develop statistical models describing the learning of endotracheal intubation (ETI). We collected data from 100 subjects undergoing ETI training with intubatable medical models and manikins (airway trainers). Trainees initially viewed a video about ETI and an instructor demonstrated the technique. Subjects then made up to 17 supervised trials. Each trial was scored as a success or failure; this score was the primary outcome used in analyses. Random effects and population-averaged logit models, and a learning model intended to quantify the relative contributions of failed and successful trials to the learning process, were fitted to the data. The logit models provided evidence of differences in difficulty between different airway trainers and differences in success rate related to previous ETI experience. Trainees became familiar with an airway trainer after multiple trials, as demonstrated by a 50% decrease in the odds of successful ETI when starting on a new trainer. The learning model indicated that a trainee learns about as much from 1 successful ETI as from 12 (95% confidence interval, 2–23) failed trials. The results demonstrate the feasibility of statistical modeling of the learning of ETI and provide insight into the learning process.


    • 1 November 2000
      • Vol. 15  (11) , 1307-11

    Influence of intestinal flora on the development of fibrosis and cirrhosis in a rat model.

    by J L Plummer, C J Ossowicz, C Whibley, A H Ilsley, P D Hall

    The gut flora play a significant role in the disposition of many foreign substances, as well as producing nutrients and toxins that may be absorbed and reach the liver. This study examines the influence of antibiotic-induced alterations in gut flora on the development of hepatic fibrosis in a rat model. Thirty-six male Porton rats were fed alcohol (3.9 g/kg per day) in the drinking water and exposed to carbon tetrachloride (CCl4) vapor (80 p.p.m.) for 6 h each night, five nights per week. Half were also given neomycin (330 mg/kg per day) and polymyxin B (105 mg/kg per day) in the drinking water. Fecal cultures were carried out at 0, 3, 8 and 13 weeks; rats were killed at 14 weeks. Coded liver section were assessed for fibrosis using a graded scale (0, no abnormal fibrosis to 4, early or established cirrhosis). Rats that received antibiotics had significantly higher fibrosis scores than those that did not (mean score 2.4 vs 1.4, P < 0.01, ordinal logistic regression). Three rats, all of which were in the antibiotic group, were cirrhotic. Rats that had received antibiotics fell into three groups. Four had overgrowth of Proteus mirabilis; in these the fibrosis scores (mean 1.5) were similar to those in the rats that did not receive antibiotic. In six, no organisms could be cultured; fibrosis scores of these (mean 2.3) were slightly elevated (P = 0.03), but this was mainly because of a single rat in this subgroup being cirrhotic. The remaining eight had overgrowth of Morganella morganii; these had significantly (P < 0.001) elevated fibrosis scores. Furthermore, in this subgroup, fibrosis scores were significantly correlated (Spearman's r = 0.82, P = 0.01) with the number of weeks of Morganella colonization. Antibiotic treatment exacerbated fibrosis in the alcohol/CCl4 rat model; this effect appeared to be related to the type of gut flora and may be endotoxin-mediated.


  • Influence of intestinal flora on the development of fibrosis and cirrhosis in a rat model1

    by John L Plummer, Chris J Ossowicz, Catherine Whibley, Anthony H Ilsley, Pauline De La M Hall

    Background and Aims: The gut flora play a significant role in the disposition of many foreign substances, as well as producing nutrients and toxins that may be absorbed and reach the liver. This study examines the influence of antibiotic‐induced alterations in gut flora on the development of hepatic fibrosis in a rat model.Methods: Thirty‐six male Porton rats were fed alcohol (3.9 g/kg per day) in the drinking water and exposed to carbon tetrachloride (CCl4) vapor (80 p.p.m.) for 6 h each night, five nights per week. Half were also given neomycin (330 mg/kg per day) and polymyxin B (105 mg/kg per day) in the drinking water. Fecal cultures were carried out at 0, 3, 8 and 13 weeks; rats were killed at 14 weeks. Coded liver section were assessed for fibrosis using a graded scale (0, no abnormal fibrosis to 4, early or established cirrhosis).Results: Rats that received antibiotics had significantly higher fibrosis scores than those that did not (mean score 2.4 vs 1.4, P < 0.01, ordinal logistic regression). Three rats, all of which were in the antibiotic group, were cirrhotic. Rats that had received antibiotics fell into three groups. Four had overgrowth of Proteus mirabilis; in these the fibrosis scores (mean 1.5) were similar to those in the rats that did not receive antibiotic. In six, no organisms could be cultured; fibrosis scores of these (mean 2.3) were slightly elevated (P = 0.03), but this was mainly because of a single rat in this subgroup being cirrhotic. The remaining eight had overgrowth of Morganella morganii; these had significantly (P < 0.001) elevated fibrosis scores. Furthermore, in this subgroup, fibrosis scores were significantly correlated (Spearman's r = 0.82, P = 0.01) with the number of weeks of Morganella colonization.Conclusions: Antibiotic treatment exacerbated fibrosis in the alcohol/CCl4 rat model; this effect appeared to be related to the type of gut flora and may be endotoxin‐mediated.


  • Dose‐related effects of dietary iron supplementation in producing hepatic iron overload in rats

    by John L Plummer, Malcolm Mackinnon, Patricia L Cmielewski, Phil Williams, Michael J Ahern, Anthony H Ilsley, Pauline DE LA M Hall

    The influence of varying the level of supplemental dietary iron on the development of hepatic iron overload was examined in rats. Two days after giving birth, Porton rats were fed a diet supplemented with 0, 0.5, 1 or 2% carbonyl iron, to institute dietary iron supplementation to the young via breast milk. After weaning, the offspring continued to receive the assigned diet until 32 weeks of age. Liver biopsies were taken from some rats at 8, 16 and 24 weeks of age and from all rats at 32 weeks of age, for assessment of iron overload. For both male and female rats, hepatic iron content was increased in a dose‐related manner by feeding supplemented diet. Hepatic iron content of male rats tended to reach a plateau after 8–16 weeks of supplementation, while that of female rats continued to rise throughout the experimental period, such that the hepatic iron content of female rats was 2.8‐fold that of similarly treated males at 32 weeks of age. Iron supplementation was associated with only moderate retardation of growth. By choosing an appropriate level of iron supplementation, good (grade III‐IV) hepatic iron loading can be achieved with minimal adverse effects on the animals’ overall health.


  • A system for standardized evaluation of patient-controlled analgesia devices: Design, construction, and engineering aspects

    by Anthony H. Ilsley, Harry Owen, John L. Plummer, Nolan A. Mackey, D. R. Digby Roberts

    Objective. Our objective was to design, construct, and assess an automated system to perform standardized evaluation of patient-controlled analgesia (PCA) devices.Methods. We developed a computer-controlled test station. The computer activates the PCA device under test through a purpose-built serial interface device. The dose delivered is weighed on an electronic balance; then, at a predetermined interval, the computer interrogates the balance via the serial interface device to determine the weight gain. A robotic digit simulates patient button presses for four commonly used demand mechanisms. Software programs were written to test three types of patient-demand profile.Results. The automated system is sufficiently accurate for evaluating PCA devices and has been successfully used to perform and evaluate several thousand demands on six different models of PCA device.Conclusions. The test station has proved to be simple to use and extremely reliable, and has enabled the successful evaluation of several types of PCA device.


  • Leakage of epidurally administered fluid into subcutaneous tissue

    by P.L. Cmielewski, J.L. Plummer, G.K. Gourlay, D.A. Cherry, P.F. Szep, R.P. Davies