James M. Paci
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
James M. Paci has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Amanda Pawlak
Department of Orthopedic Surgery, Stony Brook University School of Medicine, Stony Brook, New York, USA
2 shared publicationsAngelo Rizzi
Department of Orthopaedic Surgery SUNY Stony Brook University Medical Center Stony Brook New York U.S.A.
2 shared publicationsDavid E. Komatsu
2 shared publicationsFrederick W. Werner
Department of Orthopedic Surgery, State University of New York Upstate Medical University, Syracuse, New York
2 shared publicationsJohn P. Cannizzaro
Department of Orthopedic Surgery, State University of New York Upstate Medical University, Syracuse, New York
2 shared publicationsLevi G. Sutton
Department of Orthopedic Surgery, State University of New York Upstate Medical University, Syracuse, New York
2 shared publications
Latest Publications
- Open Access
- 10 December 2018
- Published by Wiley in Arthroscopy Techniques
- Vol. 8 (1) , E17-E21
An Arthroscopic Modification of Coracoclavicular Ligament Reconstruction and Distal Clavicle Fracture Fixation in the Lateral Position
Distal clavicle fractures and acromioclavicular injuries are common shoulder injuries. Despite the frequency of these injuries, there is no gold standard for treatment. Recent suspensory fixation techniques have minimized the amount of hardware required for surgical treatment of both acromioclavicular separations and distal clavicle fractures. Advantages include reconstruction of ligamentous anatomy, minimal hardware irritation, earlier return to activity, and decreased need for hardware removal. These reconstructions are classically done in the beach chair position in an open fashion. Our preferred technique for treatment of unstable distal clavicle fractures and acromioclavicular injuries is arthroscopy‐assisted coracoclavicular ligament reconstruction with or without distal clavicle fixation in the lateral decubitus position. Technique Video: video See video under supplementary data.
- 10 December 2018
- Published by Wiley in Arthroscopy Techniques
- Vol. 8 (1) , E17-E21
Open AccessAn Arthroscopic Modification of Coracoclavicular Ligament Reconstruction and Distal Clavicle Fracture Fixation in the Lateral Position
Distal clavicle fractures and acromioclavicular injuries are common shoulder injuries. Despite the frequency of these injuries, there is no gold standard for treatment. Recent suspensory fixation techniques have minimized the amount of hardware required for surgical treatment of both acromioclavicular separations and distal clavicle fractures. Advantages include reconstruction of ligamentous anatomy, minimal hardware irritation, earlier return to activity, and decreased need for hardware removal. These reconstructions are classically done in the beach chair position in an open fashion. Our preferred technique for treatment of unstable distal clavicle fractures and acromioclavicular injuries is arthroscopy‐assisted coracoclavicular ligament reconstruction with or without distal clavicle fixation in the lateral decubitus position. Technique Video: video See video under supplementary data.
- 1 October 2018
- Published by Frontline Medical Communications, Inc.
- Vol. 47 (10)
The In Vivo Impact of Leukocyte Injections on Normal Rat Achilles Tendons: Potential Detriment to Tendon Morphology, Cellularity, and Vascularity
In this study, we determine the in vivo effects of injecting sub-populations of leukocytes into normal rat Achilles tendons via a controlled laboratory study. Allogenic monocytes, granulocytes, or plasma were injected into 24 healthy rat Achilles tendons. Treated and contralateral un-treated control tendons then assessed for cellularity, histologic morphology, and vascularity
- 1 October 2018
- Published by Frontline Medical Communications, Inc.
- Vol. 47 (10)
The In Vivo Impact of Leukocyte Injections on Normal Rat Achilles Tendons: Potential Detriment to Tendon Morphology, Cellularity, and Vascularity
In this study, we determine the in vivo effects of injecting sub-populations of leukocytes into normal rat Achilles tendons via a controlled laboratory study. Allogenic monocytes, granulocytes, or plasma were injected into 24 healthy rat Achilles tendons. Treated and contralateral un-treated control tendons then assessed for cellularity, histologic morphology, and vascularity
- 5 February 2018
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 46 (5) , 1199-1204
Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace: A Biomechanical Cadaveric Study
Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Controlled laboratory study. Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P < .001). Group 2 showed no statistically significant differences between the augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for removal, and it is biomechanically superior to primary repair alone.
- 5 February 2018
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 46 (5) , 1199-1204
Patellar Tendon Repair Augmentation With a Knotless Suture Anchor Internal Brace: A Biomechanical Cadaveric Study
Patellar tendon repair with braided polyethylene suture alone is subject to knot slippage and failure. Several techniques to augment the primary repair have been described. The purpose was to evaluate a novel patellar tendon repair technique augmented with a knotless suture anchor internal brace with suture tape (SAIB). The hypothesis was that this technique would be biomechanically superior to a nonaugmented repair and equivalent to a standard augmentation with an 18-gauge steel wire. Controlled laboratory study. Midsubstance patellar tendon tears were created in 32 human cadaveric knees. Two comparison groups were created. Group 1 compared #2 supersuture repair without augmentation to #2 supersuture repair with SAIB augmentation. Group 2 compared #2 supersuture repair with an 18-gauge stainless steel cerclage wire augmentation to #2 supersuture repair with SAIB augmentation. The specimens were potted and biomechanically loaded on a materials testing machine. Yield load, maximum load, mode of failure, plastic displacement, elastic displacement, and total displacement were calculated for each sample. Standard statistical analysis was performed. There was a statistically significant increase in the mean ± SD yield load and maximum load in the SAIB augmentation group compared with supersuture alone (mean yield load: 646 ± 202 N vs 229 ± 60 N; mean maximum load: 868 ± 162 N vs 365 ± 54 N; P < .001). Group 2 showed no statistically significant differences between the augmented repairs (mean yield load: 495 ± 213 N vs 566 ± 172 N; P = .476; mean maximum load: 737 ± 210 N vs 697 ± 130 N; P = .721). Patellar tendon repair augmented with SAIB is biomechanically superior to repair without augmentation and is equivalent to repair with augmentation with an 18-gauge stainless steel cerclage wire. This novel patellar tendon repair augmentation is equivalent to standard 18-gauge wire augmentation at time zero. It does not require a second surgery for removal, and it is biomechanically superior to primary repair alone.
- 1 January 2018
- Published by Frontline Medical Communications, Inc. in The American Journal of Orthopedics
- Vol. 47 (1)
Knotless Tape Suture Fixation of Quadriceps Tendon Rupture: A Novel Technique
Quadriceps tendon ruptures disrupt the extensor mechanism of the knee and require urgent surgical management. Traditional repair techniques have had mixed biomechanical and clinical results risking weakness and extensor lag. We describe a novel technique using tape suture and knotless anchors, which has performed superiorly during biomechanical testing and yielded terrific early clinical results.
- 1 January 2018
- Published by Frontline Medical Communications, Inc. in The American Journal of Orthopedics
- Vol. 47 (1)
Knotless Tape Suture Fixation of Quadriceps Tendon Rupture: A Novel Technique
Quadriceps tendon ruptures disrupt the extensor mechanism of the knee and require urgent surgical management. Traditional repair techniques have had mixed biomechanical and clinical results risking weakness and extensor lag. We describe a novel technique using tape suture and knotless anchors, which has performed superiorly during biomechanical testing and yielded terrific early clinical results.
- 7 November 2017
- Published by Springer Nature
- p. 213-222
Type 4 SLAP Tear in 21-Year-Old Minor League Centerfielder
- 7 November 2017
- Published by Springer Nature
- p. 213-222
Type 4 SLAP Tear in 21-Year-Old Minor League Centerfielder
- 1 November 2016
- Published by Elsevier in Physical Therapy in Sport
- Vol. 22, 54-60
Sagittal plane kinematic differences between dominant and non-dominant legs in unilateral and bilateral jump landings
- 1 November 2016
- Published by Elsevier in Physical Therapy in Sport
- Vol. 22, 54-60
Sagittal plane kinematic differences between dominant and non-dominant legs in unilateral and bilateral jump landings
- 8 August 2016
- Published by Wiley in Arthroscopy
- Vol. 33 (1) , 190-198
Knotless Suture Anchor With Suture Tape Quadriceps Tendon Repair Is Biomechanically Superior to Transosseous and Traditional Suture Anchor–Based Repairs in a Cadaveric Model
Purpose: To compare the biomechanical properties of a knotless suture anchor with suture tape quadriceps tendon repair technique with transosseous and suture anchor repair techniques. Methods: Twenty matched pairs of cadaveric knees underwent a quadriceps tendon avulsion followed by repair via the use of transosseous tunnels with #2 high‐strength sutures, 5.5‐mm biocomposite fully threaded suture anchors with #2 high‐strength sutures, or 4.75‐mm biocomposite knotless suture anchors with suture tape. Ten knees were repaired via transosseous repair and 10 via fully threaded suture anchor repair, and their matched specimens were repaired with suture tape and knotless anchors. Biomechanical analysis included displacement during cyclic loading over 250 cycles, construct stiffness, ultimate load to failure, and failure mode analysis. Results: Compared with transosseous repairs, quadriceps tendons repaired with knotless suture tape demonstrated significantly less displacement during cyclic loading (cycles 1‐20 3.6 ± 1.3 vs 6.3 ± 1.9 mm, P = .003; cycles 20‐250 2.0 ± 0.4 vs 3.1 ± 0.9 mm, P = .011), improved construct stiffness (67 ± 25 vs 26 ± 12 N/mm, P = .001), and greater ultimate load to failure (616 ± 149 vs 413 ± 107 N, P = .004). Our repair technique also demonstrated improved biomechanical parameters compared with fully threaded suture anchor repair in initial displacement during cyclic loading (cycles 1‐20 3.0 ± 0.8 vs 5.1 ± 0.9 mm, P < .001), construct stiffness (62 ± 20 vs 28 ± 10 N/mm, P = .001) and ultimate load to failure (579 ± 129 vs 399 ± 87 N, P = .006). Conclusions: Repair of quadriceps tendon ruptures with this knotless suture anchor with suture tape repair technique is biomechanically superior in cyclic displacement, construct stiffness, and ultimate load to failure compared with transosseous and fully threaded suture anchor techniques in cadaveric specimens. Clinical Relevance: The demonstration that our repair technique is biomechanically superior to previously described techniques in a cadaveric setting suggests that consideration should be given to this technique.
- 8 August 2016
- Published by Wiley in Arthroscopy
- Vol. 33 (1) , 190-198
Knotless Suture Anchor With Suture Tape Quadriceps Tendon Repair Is Biomechanically Superior to Transosseous and Traditional Suture Anchor–Based Repairs in a Cadaveric Model
Purpose: To compare the biomechanical properties of a knotless suture anchor with suture tape quadriceps tendon repair technique with transosseous and suture anchor repair techniques. Methods: Twenty matched pairs of cadaveric knees underwent a quadriceps tendon avulsion followed by repair via the use of transosseous tunnels with #2 high‐strength sutures, 5.5‐mm biocomposite fully threaded suture anchors with #2 high‐strength sutures, or 4.75‐mm biocomposite knotless suture anchors with suture tape. Ten knees were repaired via transosseous repair and 10 via fully threaded suture anchor repair, and their matched specimens were repaired with suture tape and knotless anchors. Biomechanical analysis included displacement during cyclic loading over 250 cycles, construct stiffness, ultimate load to failure, and failure mode analysis. Results: Compared with transosseous repairs, quadriceps tendons repaired with knotless suture tape demonstrated significantly less displacement during cyclic loading (cycles 1‐20 3.6 ± 1.3 vs 6.3 ± 1.9 mm, P = .003; cycles 20‐250 2.0 ± 0.4 vs 3.1 ± 0.9 mm, P = .011), improved construct stiffness (67 ± 25 vs 26 ± 12 N/mm, P = .001), and greater ultimate load to failure (616 ± 149 vs 413 ± 107 N, P = .004). Our repair technique also demonstrated improved biomechanical parameters compared with fully threaded suture anchor repair in initial displacement during cyclic loading (cycles 1‐20 3.0 ± 0.8 vs 5.1 ± 0.9 mm, P < .001), construct stiffness (62 ± 20 vs 28 ± 10 N/mm, P = .001) and ultimate load to failure (579 ± 129 vs 399 ± 87 N, P = .006). Conclusions: Repair of quadriceps tendon ruptures with this knotless suture anchor with suture tape repair technique is biomechanically superior in cyclic displacement, construct stiffness, and ultimate load to failure compared with transosseous and fully threaded suture anchor techniques in cadaveric specimens. Clinical Relevance: The demonstration that our repair technique is biomechanically superior to previously described techniques in a cadaveric setting suggests that consideration should be given to this technique.
- Open Access
- 18 September 2014
- Published by Wiley in Arthroscopy Techniques
- Vol. 3 (5) , e621-6
Distal Triceps Knotless Anatomic Footprint Repair: A New Technique
Distal triceps rupture is a rare injury causing significant disability. Several techniques for treating distal triceps ruptures have been described using bone tunnels or suture anchors. More recent techniques have focused on re‐creating the anatomic footprint of the distal triceps tendon. However, the increasing numbers of anchors used increase the risk to the articular surface, and all earlier techniques require knot tying and bulky knots beneath the thin posterior elbow soft‐tissue envelope. We describe a technique combining the use of bone tunnels and a single suture anchor to create a knotless anatomic footprint repair of the distal triceps. By using this technique, we are able to create a tension‐band construct that self‐reinforces the anatomic repair and is very low profile while significantly decreasing risk to the articular surface. Technique Video: video See video under supplementary data.
- 18 September 2014
- Published by Wiley in Arthroscopy Techniques
- Vol. 3 (5) , e621-6
Open AccessDistal Triceps Knotless Anatomic Footprint Repair: A New Technique
Distal triceps rupture is a rare injury causing significant disability. Several techniques for treating distal triceps ruptures have been described using bone tunnels or suture anchors. More recent techniques have focused on re‐creating the anatomic footprint of the distal triceps tendon. However, the increasing numbers of anchors used increase the risk to the articular surface, and all earlier techniques require knot tying and bulky knots beneath the thin posterior elbow soft‐tissue envelope. We describe a technique combining the use of bone tunnels and a single suture anchor to create a knotless anatomic footprint repair of the distal triceps. By using this technique, we are able to create a tension‐band construct that self‐reinforces the anatomic repair and is very low profile while significantly decreasing risk to the articular surface. Technique Video: video See video under supplementary data.
- 6 December 2012
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 41 (2) , 306-312
Cannulated Screw Fixation of Refractory Olecranon Stress Fractures With and Without Associated Injuries Allows a Return to Baseball
Background: An olecranon stress fracture is a rare injury associated with valgus extension overload in baseball players. No long-term outcomes studies have been published documenting the results of surgical fixation of olecranon stress fractures with or without concomitant injuries in baseball players. Hypothesis: Open reduction and internal fixation (ORIF) of an olecranon stress fracture will reliably produce bony union and allow a successful return to the previous level of activity in competitive baseball players. Study Design: Case series; Level of evidence, 4. Methods: Twenty-five patients treated with ORIF for an olecranon stress fracture at least 2 years earlier (range, 2-10.14 years) were retrospectively contacted to complete a telephone survey; 18 of 25 (72%) patients responded. Data were collected to determine the return to play rate, level of arm pain, and overall arm function. Results: All 18 stress fractures went on to successful union; 17 of 18 (94%) athletes returned to baseball at or above their previous level. Average return to play time was 29 weeks. The numeric analog pain score was 0.2 at rest and 0.3 when throwing at the time of follow-up, at an average 6.2 years (range, 2.0-10.14 years) after surgery. The average score at follow-up on the Disabilities of the Arm, Shoulder and Hand Outcome Measure–shortened version ( QuickDASH) was 4.1 (range, 0-27.3). Ten (56%) patients required 13 additional future surgeries on their throwing arm; 7 surgeries in 6 (33%) patients were not related to the index surgery. Six of 18 (33%) patients underwent hardware removal, with 2 (11%) for infection. Conclusion: Open reduction and internal fixation of olecranon stress fractures in competitive baseball players has a high rate of success in returning players to or above their former level of play and allows for good elbow function at an average of 6.2 years postoperatively. However, these patients are at high risk for additional future surgeries on their throwing arm.
- 6 December 2012
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 41 (2) , 306-312
Cannulated Screw Fixation of Refractory Olecranon Stress Fractures With and Without Associated Injuries Allows a Return to Baseball
Background: An olecranon stress fracture is a rare injury associated with valgus extension overload in baseball players. No long-term outcomes studies have been published documenting the results of surgical fixation of olecranon stress fractures with or without concomitant injuries in baseball players. Hypothesis: Open reduction and internal fixation (ORIF) of an olecranon stress fracture will reliably produce bony union and allow a successful return to the previous level of activity in competitive baseball players. Study Design: Case series; Level of evidence, 4. Methods: Twenty-five patients treated with ORIF for an olecranon stress fracture at least 2 years earlier (range, 2-10.14 years) were retrospectively contacted to complete a telephone survey; 18 of 25 (72%) patients responded. Data were collected to determine the return to play rate, level of arm pain, and overall arm function. Results: All 18 stress fractures went on to successful union; 17 of 18 (94%) athletes returned to baseball at or above their previous level. Average return to play time was 29 weeks. The numeric analog pain score was 0.2 at rest and 0.3 when throwing at the time of follow-up, at an average 6.2 years (range, 2.0-10.14 years) after surgery. The average score at follow-up on the Disabilities of the Arm, Shoulder and Hand Outcome Measure–shortened version ( QuickDASH) was 4.1 (range, 0-27.3). Ten (56%) patients required 13 additional future surgeries on their throwing arm; 7 surgeries in 6 (33%) patients were not related to the index surgery. Six of 18 (33%) patients underwent hardware removal, with 2 (11%) for infection. Conclusion: Open reduction and internal fixation of olecranon stress fractures in competitive baseball players has a high rate of success in returning players to or above their former level of play and allows for good elbow function at an average of 6.2 years postoperatively. However, these patients are at high risk for additional future surgeries on their throwing arm.
- 10 August 2010
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 38 (11) , 2267-2272
Results of Laboratory Evaluation of Acute Knee Effusion after Anterior Cruciate Ligament Reconstruction
Background: Infection after anterior cruciate ligament reconstruction is a rare and potentially devastating complication. No normative data have been reported for knee aspiration after anterior cruciate ligament reconstruction in the early postoperative period. Hypothesis: Determining normative laboratory data from a retrospective review of noninfected early postoperative anterior cruciate ligament reconstruction knee effusions will allow for the calculation of an aspirate white blood cell (WBC) threshold value indicative of infection. Study Design: Case series (diagnosis); Level of evidence, 4. Methods: A 2-year retrospective chart review of 151 anterior cruciate ligament reconstruction patients was performed. Thirty-one noninfected patients meeting the inclusion and exclusion criteria and 1 infected patient had laboratory data collected, including peripheral blood and knee effusion aspirate analyses. Laboratory data from pertinent published studies of infected knees after anterior cruciate ligament reconstruction were combined with the data of our 1 infected patient, establishing a historical control group. Data were analyzed and results were then compared. Infected aspirate WBC threshold value statistics were then calculated. Results: Analysis of noninfected knee effusion aspirates revealed a mean WBC count of 9600/uL (standard deviation [SD], 15 200), and a mean of 66% polymorphonuclear (PMN) cells (SD, 34). Aspirate WBC 98% confidence interval (CI) was 2800/uL to 16 200/uL, and the 98% CI for PMN cells was 58% to 84%. Aspirate WBC count >16 200/uL is 86% sensitive, 92% specific, and has a positive likelihood ratio of 10.4 as an indicator of infection. Conclusion: Benign effusion after anterior cruciate ligament reconstruction is common and is associated with elevated inflammatory markers. When concerned, knee aspiration after anterior cruciate ligament surgery gives the highest yield to differentiate between a painful effusion and a septic knee in the early postoperative period while awaiting definitive culture results. The authors report confidence intervals defining the range of cell count variables for noninfected patients requiring aspiration, specifically WBC and PMN, and suggest a WBC threshold value of >16 200/uL be used as an indicator of infection. On the basis of comparison with historical control data, the authors believe these data are significant and will be reliable for clinical use.
- 10 August 2010
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 38 (11) , 2267-2272
Results of Laboratory Evaluation of Acute Knee Effusion after Anterior Cruciate Ligament Reconstruction
Background: Infection after anterior cruciate ligament reconstruction is a rare and potentially devastating complication. No normative data have been reported for knee aspiration after anterior cruciate ligament reconstruction in the early postoperative period. Hypothesis: Determining normative laboratory data from a retrospective review of noninfected early postoperative anterior cruciate ligament reconstruction knee effusions will allow for the calculation of an aspirate white blood cell (WBC) threshold value indicative of infection. Study Design: Case series (diagnosis); Level of evidence, 4. Methods: A 2-year retrospective chart review of 151 anterior cruciate ligament reconstruction patients was performed. Thirty-one noninfected patients meeting the inclusion and exclusion criteria and 1 infected patient had laboratory data collected, including peripheral blood and knee effusion aspirate analyses. Laboratory data from pertinent published studies of infected knees after anterior cruciate ligament reconstruction were combined with the data of our 1 infected patient, establishing a historical control group. Data were analyzed and results were then compared. Infected aspirate WBC threshold value statistics were then calculated. Results: Analysis of noninfected knee effusion aspirates revealed a mean WBC count of 9600/uL (standard deviation [SD], 15 200), and a mean of 66% polymorphonuclear (PMN) cells (SD, 34). Aspirate WBC 98% confidence interval (CI) was 2800/uL to 16 200/uL, and the 98% CI for PMN cells was 58% to 84%. Aspirate WBC count >16 200/uL is 86% sensitive, 92% specific, and has a positive likelihood ratio of 10.4 as an indicator of infection. Conclusion: Benign effusion after anterior cruciate ligament reconstruction is common and is associated with elevated inflammatory markers. When concerned, knee aspiration after anterior cruciate ligament surgery gives the highest yield to differentiate between a painful effusion and a septic knee in the early postoperative period while awaiting definitive culture results. The authors report confidence intervals defining the range of cell count variables for noninfected patients requiring aspiration, specifically WBC and PMN, and suggest a WBC threshold value of >16 200/uL be used as an indicator of infection. On the basis of comparison with historical control data, the authors believe these data are significant and will be reliable for clinical use.