Mitchell S. Albert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mitchell S. Albert has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Arvind K. Venkatesh
Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA
4 shared publicationsDilip Balamore
Department of Engineering/Physics/Technology, Nassau Community College, Garden City, NY 11530, USA
3 shared publicationsFerenc A. Jolesz
Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA
3 shared publicationsDaniel F. Kacher
Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA
2 shared publicationsLei Zhao
Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, Boston, MA 02115, USA
2 shared publicationsAngela C. Tooker
Brigham and Women's Hospital, Boston, Massachusetts
1 shared publication
Latest Publications
- Open Access
- 27 January 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (2) , 474-478
Quantification of airway diameters and 3D airway tree rendering from dynamic hyperpolarized 3He magnetic resonance imaging
As another step toward extracting quantitative information from hyperpolarized 3He MRI, airway diameters in humans were measured from projection images and multislice images of the lungs. Values obtained were in good agreement with the Weibel lung morphometry model. The measurement of airway caliber can now be achieved without the use of ionizing radiation. Furthermore, it was demonstrated that 3D airway tree renderings could be constructed from the multislice data. Both the measurement of airway diameters and the rendering of 3D airway information hold promise for the clinical assessment of bronchoconstrictive diseases such as asthma and the associated evaluation of treatment effectiveness. Work is being done to address the uncertainties of the manually intensive methods we have developed. Magn Reson Med 53:474–478, 2005.
- 27 January 2005
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 53 (2) , 474-478
Open AccessQuantification of airway diameters and 3D airway tree rendering from dynamic hyperpolarized 3He magnetic resonance imaging
As another step toward extracting quantitative information from hyperpolarized 3He MRI, airway diameters in humans were measured from projection images and multislice images of the lungs. Values obtained were in good agreement with the Weibel lung morphometry model. The measurement of airway caliber can now be achieved without the use of ionizing radiation. Furthermore, it was demonstrated that 3D airway tree renderings could be constructed from the multislice data. Both the measurement of airway diameters and the rendering of 3D airway information hold promise for the clinical assessment of bronchoconstrictive diseases such as asthma and the associated evaluation of treatment effectiveness. Work is being done to address the uncertainties of the manually intensive methods we have developed. Magn Reson Med 53:474–478, 2005.
- 22 November 2000
- Published by Wiley in NMR in Biomedicine
- Vol. 13 (7) , 407-414
Hyperpolarized129XeT1 in oxygenated and deoxygenated blood
The viability of the new technique of hyperpolarized 129Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin–lattice relaxation time, T1, of 129Xe is sufficiently long in the blood. In previous experiments by the authors, the T1 was found to be strongly dependent upon the oxygenation of the blood, with T1 increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79–86) reported extremely long T1 values deduced from an indirect experiment in which hyperpolarized 129Xe was used to create a ‘blood-foam’. They found that oxygenation decreased T1. Pivotal to their experiment is the continual and rapid exchange of hyperpolarized 129Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T1 of 129Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized 129Xe has been bubbled through the sample. This study confirms that oxygenation increases the T1 of 129Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright © 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO2 oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.
- 22 November 2000
- Published by Wiley in NMR in Biomedicine
- Vol. 13 (7) , 407-414
Hyperpolarized129XeT1 in oxygenated and deoxygenated blood
The viability of the new technique of hyperpolarized 129Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin–lattice relaxation time, T1, of 129Xe is sufficiently long in the blood. In previous experiments by the authors, the T1 was found to be strongly dependent upon the oxygenation of the blood, with T1 increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79–86) reported extremely long T1 values deduced from an indirect experiment in which hyperpolarized 129Xe was used to create a ‘blood-foam’. They found that oxygenation decreased T1. Pivotal to their experiment is the continual and rapid exchange of hyperpolarized 129Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T1 of 129Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized 129Xe has been bubbled through the sample. This study confirms that oxygenation increases the T1 of 129Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright © 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO2 oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.
- Open Access
- 21 June 2000
- Published by Wiley in NMR in Biomedicine
- Vol. 13 (4) , 245-252
Evaluation of carrier agents for hyperpolarized xenon MRI
- 21 June 2000
- Published by Wiley in NMR in Biomedicine
- Vol. 13 (4) , 245-252
Open AccessEvaluation of carrier agents for hyperpolarized xenon MRI
- Open Access
- 21 June 2000
- Published by Wiley in NMR in Biomedicine
- Vol. 13 (4) , 253-264
Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging
The physiological effects of various hyperpolarized helium and xenon MRI‐compatible breathing protocols were investigated in 17 Sprague–Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath‐holds of pure noble gas for varying durations, and helium breath‐holds preceded by two helium rinses. Alternate‐breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous‐breaths caused a 31.5% ± 2.3% decrease in oxygen saturation for helium and a 30.7% ± 1.3% decrease for xenon. Breath‐hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath‐hold, the blood oxygen saturation dropped precipitously to 82% ± 0.6% for helium, and to 76.5% ± 7.4% for xenon. Breath‐holds longer than 10 s preceded by pre‐rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath‐hold and alternate‐breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright © 2000 John Wiley & Sons, Ltd.
- 21 June 2000
- Published by Wiley in NMR in Biomedicine
- Vol. 13 (4) , 253-264
Open AccessPhysiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging
The physiological effects of various hyperpolarized helium and xenon MRI‐compatible breathing protocols were investigated in 17 Sprague–Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath‐holds of pure noble gas for varying durations, and helium breath‐holds preceded by two helium rinses. Alternate‐breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous‐breaths caused a 31.5% ± 2.3% decrease in oxygen saturation for helium and a 30.7% ± 1.3% decrease for xenon. Breath‐hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath‐hold, the blood oxygen saturation dropped precipitously to 82% ± 0.6% for helium, and to 76.5% ± 7.4% for xenon. Breath‐holds longer than 10 s preceded by pre‐rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath‐hold and alternate‐breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright © 2000 John Wiley & Sons, Ltd.
- 1 September 1999
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 140 (1) , 264-273
T1 of 129Xe in Blood and the Role of Oxygenation
- 1 September 1999
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 140 (1) , 264-273
T1 of 129Xe in Blood and the Role of Oxygenation
- 1 January 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 402 (2-3) , 441-453
Development of hyperpolarized noble gas MRI
- 1 January 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 402 (2-3) , 441-453
Development of hyperpolarized noble gas MRI
- Open Access
- 1 January 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 402 (2-3) , 454-460
Biomedical imaging using hyperpolarized noble gas MRI: Pulse sequence considerations
- 1 January 1998
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 402 (2-3) , 454-460
Open AccessBiomedical imaging using hyperpolarized noble gas MRI: Pulse sequence considerations