Udo Nagele
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Udo Nagele has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Arnulf Stenzl
Department of Urology, University of Tübingen, Tübingen, Germany
13 shared publicationsKarl-Dietrich Sievert
Department of Urology, University of Tübingen, Tübingen, Germany
11 shared publicationsAristotelis G. Anastasiadis
University of Tuebingen
9 shared publicationsDavid Schilling
Department of Urology, University of Tuebingen, Tuebingen, Germany
6 shared publicationsMarkus Kuczyk
6 shared publicationsA. Stenzl
Klinik für Urologie, Universitätsklinikum, Tübingen, Deutschland
3 shared publications
Latest Publications
- 1 March 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (7_suppl) , 310
Laser versus electrical en bloc resection of bladder tumors: Results of a European multicenter study (EBRUC).
310 Background: The quality of transurethral resection of bladder tumors strongly determines patient’s tumor after-care and prognosis. En bloc resection of bladder tumors (ERBT) might improve staging quality, perioperative morbidity and influence tumor recurrence. This is the first European multi-center study which was initiated by ESUT and was conducted to evaluate the safety, efficacy and recurrence rates of electrical vs. laser ERBT. Methods: Transurethral ERBT was performed on 221 prospectively collected patients in six academic centers with either monopolar/bipolar current or holmium/thulium laser energy. Staging quality measured by detrusor muscle involvement, various perioperative/surgical parameters and 12 months follow-up data were analyzed. Results: 156 and 65 patients were treated with electrical and laser ERBT, respectively. Median tumor size was 2.1 cm with biggest up to 5 cm. Detrusor muscle was available in 97.3%. A switch to conventional TURBT was significantly more frequent in the electrical ERBT group (26.3% vs. 1.5%, p1 cm. Recurrence rates did not differ within both groups although the majority of recurrences were noticed out of the ERBT resection field. Laser device might be an alternative for the treatment of patients with higher risk of postoperative bleeding due to its efficient hemostatic effect.
- 1 March 2015
- Published by American Society of Clinical Oncology (ASCO) in Journal of Clinical Oncology
- Vol. 33 (7_suppl) , 310
Laser versus electrical en bloc resection of bladder tumors: Results of a European multicenter study (EBRUC).
310 Background: The quality of transurethral resection of bladder tumors strongly determines patient’s tumor after-care and prognosis. En bloc resection of bladder tumors (ERBT) might improve staging quality, perioperative morbidity and influence tumor recurrence. This is the first European multi-center study which was initiated by ESUT and was conducted to evaluate the safety, efficacy and recurrence rates of electrical vs. laser ERBT. Methods: Transurethral ERBT was performed on 221 prospectively collected patients in six academic centers with either monopolar/bipolar current or holmium/thulium laser energy. Staging quality measured by detrusor muscle involvement, various perioperative/surgical parameters and 12 months follow-up data were analyzed. Results: 156 and 65 patients were treated with electrical and laser ERBT, respectively. Median tumor size was 2.1 cm with biggest up to 5 cm. Detrusor muscle was available in 97.3%. A switch to conventional TURBT was significantly more frequent in the electrical ERBT group (26.3% vs. 1.5%, p1 cm. Recurrence rates did not differ within both groups although the majority of recurrences were noticed out of the ERBT resection field. Laser device might be an alternative for the treatment of patients with higher risk of postoperative bleeding due to its efficient hemostatic effect.
- 30 April 2009
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 181 (4) , 581
INTERLEUKINE-6 AND C-REACTIVE PROTEIN AS MARKERS FOR INTERVENTIONAL STRESS IN RENAL STONE TREATMENT - A COMPARISON BETWEEN EXTRACORPOREAL SHOCKWAVE LITHOTRIPSY, URETERORENOSCOPY AND MINIMALLY INVASIVE PERCUTANEOUS NEPHROLITHOLAPAXY
- 30 April 2009
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 181 (4) , 581
INTERLEUKINE-6 AND C-REACTIVE PROTEIN AS MARKERS FOR INTERVENTIONAL STRESS IN RENAL STONE TREATMENT - A COMPARISON BETWEEN EXTRACORPOREAL SHOCKWAVE LITHOTRIPSY, URETERORENOSCOPY AND MINIMALLY INVASIVE PERCUTANEOUS NEPHROLITHOLAPAXY
- 1 December 2008
- Published by Elsevier in European Urology
- Vol. 54 (6) , 1414-1422
In Vitro Investigations of Tissue-Engineered Multilayered Urothelium Established from Bladder Washings
- 1 December 2008
- Published by Elsevier in European Urology
- Vol. 54 (6) , 1414-1422
In Vitro Investigations of Tissue-Engineered Multilayered Urothelium Established from Bladder Washings
- 1 September 2008
- Published by SAGE Publications in Journal of Endourology
- Vol. 22 (9) , 1859-1860
Rebuttal
- 1 September 2008
- Published by SAGE Publications in Journal of Endourology
- Vol. 22 (9) , 1859-1860
Rebuttal
- 1 September 2008
- Published by SAGE Publications in Journal of Endourology
- Vol. 22 (9) , 1851-1854
Management of Lower-Pole Stones of 0.8 to 1.5 cm Maximal Diameter by the Minimally Invasive Percutaneous Approach
The only peer-reviewed journal focused on the rapidly moving field of 3D printing and related technologies, providing comprehensive coverage of academic research and industrial and commercial developments that have applications in medicine, education, food, and architecture.
- 1 September 2008
- Published by SAGE Publications in Journal of Endourology
- Vol. 22 (9) , 1851-1854
Management of Lower-Pole Stones of 0.8 to 1.5 cm Maximal Diameter by the Minimally Invasive Percutaneous Approach
The only peer-reviewed journal focused on the rapidly moving field of 3D printing and related technologies, providing comprehensive coverage of academic research and industrial and commercial developments that have applications in medicine, education, food, and architecture.
- 17 August 2008
- Published by Springer Nature in Der Urologe
- Vol. 47 (9) , 1066-1073
Minimal-invasive perkutane Nephrolitholapaxie (MIP)
- 17 August 2008
- Published by Springer Nature in Der Urologe
- Vol. 47 (9) , 1066-1073
Minimal-invasive perkutane Nephrolitholapaxie (MIP)
- 7 March 2008
- Published by Springer Nature in World Journal of Urology
- Vol. 26 (3) , 257-262
Initial clinical experience with full-length metal ureteral stents for obstructive ureteral stenosis
Long-term ureteral stenting is used to ensure urinary drainage if a reconstructive approach or a release of an extrinsic obstruction is not possible. In this contribution, a long-term experience with a new full-length, metal indwelling stent is presented.
- 7 March 2008
- Published by Springer Nature in World Journal of Urology
- Vol. 26 (3) , 257-262
Initial clinical experience with full-length metal ureteral stents for obstructive ureteral stenosis
Long-term ureteral stenting is used to ensure urinary drainage if a reconstructive approach or a release of an extrinsic obstruction is not possible. In this contribution, a long-term experience with a new full-length, metal indwelling stent is presented.
- 2 March 2008
- Published by Springer Nature in Der Urologe
- Vol. 47 (5) , 601-607
Die Verwendung von Gelatine-Thrombin-Matrix zum Verschluss des Arbeitskanals bei der nephrostomielosen minimal-invasiven perkutanen Nephrolitholapaxie
- 2 March 2008
- Published by Springer Nature in Der Urologe
- Vol. 47 (5) , 601-607
Die Verwendung von Gelatine-Thrombin-Matrix zum Verschluss des Arbeitskanals bei der nephrostomielosen minimal-invasiven perkutanen Nephrolitholapaxie
- 1 September 2007
- Published by SAGE Publications in Journal of Endourology
- Vol. 21 (9) , 1113-1116
A Newly Designed Amplatz Sheath Decreases Intrapelvic Irrigation Pressure During Mini-Percutaneous Nephrolitholapaxy: An in-Vitro Pressure-Measurement and Microscopic Study
Background and Purpose: In recent years, mini-percutaneous nephrolitholapaxy (mini-PCNL) has gained popularity because of its reduced invasiveness. To improve clinical outcomes further, research is ongoing in selected centers. Important areas of interest include extravasation into the retroperitoneal space, acute absorption syndrome, and septicemia. The aim of this experimental study was to test a new 18F nephroscope sheath specially designed to decrease intrapelvic pressure during mini-PCNL whatever the irrigation pressure. In addition, the hydrodynamic effects of this device can be used for suction and removal of the stone fragments, in contrast to a standard Amplatz sheath. Materials and Methods: In a fresh, perfused cadaveric porcine kidney model, the new sheath was compared with a conventional sheath (control) with closed and open Luer-Lok outflow under increasing irrigation pressure. Intrarenal pressure peaks were measured with a urodynamic workstation. The irrigation fluid was marked with an ink that stains only endoluminal surfaces, and a post-measurement histopathologic work-up was performed to evaluate the changes on a morphologic level. Results: Closing of the control sheath resulted in an increase in the intrapelvic pressure to a maximum of 136 cm H2O. Using the new sheath with a constant output flow made possible by its open proximal end, the maximal intrapelvic pressure remained low at 20 cm H2O, even when the inflow pressure reached 125 cm H2O. The ink distribution on the hematoxylin and eosin-stained slides reflected the results of the pressure measurements. Conclusions: Newly designed nephroscope sheaths with an open proximal end, such as the one described here, decrease the intrapelvic pressure compared with a closed outflow system. As a result, strict fluid control during the intervention is not necessary.
- 1 September 2007
- Published by SAGE Publications in Journal of Endourology
- Vol. 21 (9) , 1113-1116
A Newly Designed Amplatz Sheath Decreases Intrapelvic Irrigation Pressure During Mini-Percutaneous Nephrolitholapaxy: An in-Vitro Pressure-Measurement and Microscopic Study
Background and Purpose: In recent years, mini-percutaneous nephrolitholapaxy (mini-PCNL) has gained popularity because of its reduced invasiveness. To improve clinical outcomes further, research is ongoing in selected centers. Important areas of interest include extravasation into the retroperitoneal space, acute absorption syndrome, and septicemia. The aim of this experimental study was to test a new 18F nephroscope sheath specially designed to decrease intrapelvic pressure during mini-PCNL whatever the irrigation pressure. In addition, the hydrodynamic effects of this device can be used for suction and removal of the stone fragments, in contrast to a standard Amplatz sheath. Materials and Methods: In a fresh, perfused cadaveric porcine kidney model, the new sheath was compared with a conventional sheath (control) with closed and open Luer-Lok outflow under increasing irrigation pressure. Intrarenal pressure peaks were measured with a urodynamic workstation. The irrigation fluid was marked with an ink that stains only endoluminal surfaces, and a post-measurement histopathologic work-up was performed to evaluate the changes on a morphologic level. Results: Closing of the control sheath resulted in an increase in the intrapelvic pressure to a maximum of 136 cm H2O. Using the new sheath with a constant output flow made possible by its open proximal end, the maximal intrapelvic pressure remained low at 20 cm H2O, even when the inflow pressure reached 125 cm H2O. The ink distribution on the hematoxylin and eosin-stained slides reflected the results of the pressure measurements. Conclusions: Newly designed nephroscope sheaths with an open proximal end, such as the one described here, decrease the intrapelvic pressure compared with a closed outflow system. As a result, strict fluid control during the intervention is not necessary.