Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hajo Müller has a total of 68 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Left Ventricular Performance and Afterload on the Evaluation of Aortic Valve Stenosis: A 1D Mathematical Modeling Approach

    by Cemre Çelikbudak Orhon, Nikolaos Stergiopulos, Stéphane Noble, Georgios Giannakopoulos, Hajo Müller, Dionysios Adamopoulos

    The transaortic valvular pressure gradient (TPG) plays a central role in decision-making for patients suffering from severe aortic stenosis. However, the flow-dependence nature of the TPG makes the diagnosis of aortic stenosis challenging since the markers of cardiac performance and afterload present high physiological interdependence and thus, isolated effects cannot be measured directly in vivo. We used a validated 1D mathematical model of the cardiovascular system, coupled with a model of aortic stenosis, to assess and quantify the independent effect of the main left ventricular performance parameters (end-systolic (Ees) and end-diastolic (Eed) elastance) and principal afterload indices (total vascular resistance (TVR) and total arterial compliance (TAC)) on the TPG for different levels of aortic stenosis. In patients with critical aortic stenosis (aortic valve area (AVA) ≤ 0.6 cm2), a 10% increase of Eed from the baseline value was associated with the most important effect on the TPG (−5.6 ± 0.5 mmHg, p < 0.001), followed by a similar increase of Ees (3.4 ± 0.1 mmHg, p < 0.001), in TAC (1.3 ±0.2 mmHg, p < 0.001) and TVR (−0.7 ± 0.04 mmHg, p < 0.001). The interdependence of the TPG left ventricular performance and afterload indices become stronger with increased aortic stenosis severity. Disregarding their effects may lead to an underestimation of stenosis severity and a potential delay in therapeutic intervention. Therefore, a comprehensive evaluation of left ventricular function and afterload should be performed, especially in cases of diagnostic challenge, since it may offer the pathophysiological mechanism that explains the mismatch between aortic severity and the TPG.


  • Open Access

    Prognostic Implications of the Novel Pulmonary Hypertension Definition in Patients with Aortic Stenosis after Transcatheter Valve Replacement

    by Dionysios Adamopoulos, Stamatia Pagoulatou, Georgios Rovas, Vasiliki Bikia, Hajo Müller, Georgios Giannakopoulos, Sarah Mauler-Wittwer, Marc-Joseph Licker, Nikolaos Stergiopulos, Frédéric Lador, et al.

    Introduction: Pulmonary hypertension (PH), traditionally defined as a mean pulmonary artery pressure (PAP) ≥ 25 mmHg, is associated with poor outcomes in patients undergoing a transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS). Recently, a novel definition for PH has been proposed, placing the cut-off value of mean PAP at 20 mmHg, and introducing pulmonary vascular resistance as an exclusive indicator for the pre-capillary involvement. In light of the novel criteria, whether PH still preserves its prognostic significance remains unknown. Methods: The study population consisted of 380 patients with AS, who underwent a right heart catheterization before TAVR. The cohort was divided according to the presence of PH (n = 174, 45.7%) or not. Patients with PH were further divided into the following groups: (1) Pre-capillary PH ((Pre-capPH), n = 46, 12.1%); (2) Isolated post-capillary PH ((IpcPH), n = 78, 20.5%); (3) Combined pre and post-capillary PH ((CpcPH), n = 82, 21.6%). The primary endpoint was all-cause mortality at 1 year. Results: A total of 246 patients (64.7%) exhibited mean PAP > 20 mmHg. Overall, the presence of PH was associated with higher 1-year mortality rates (hazard ratio (HR) 2.8, 95% CI: 1.4–5.8, p = 0.004). Compared to patients with no PH, Pre-capPH and CpcPH (but not IpcPH) were related to higher 1-year mortality (HR 2.7, 95% CI: 1.0–7.2, p = 0.041 and HR 3.9, 95% CI: 1.8–8.5, p = 0.001, respectively). This remained significant even after the adjustment for baseline comorbidities. Conclusions: Pre-interventional PH according to the novel hemodynamic criteria, is linked with poor outcomes in patients undergoing TAVR for severe AS. However, this is mainly driven by patients with mean PAP ≥ 25 mmHg. Patients with a pre-capillary PH component as defined by increased PVR present an even worse prognosis as compared to patients with isolated post-capillary or no PH who present comparable 1-year mortality rates.


  • Open Access

    Prognostic Value of the Echocardiographic Probability of Pulmonary Hypertension in Patients with Acute Decompensated Heart Failure

    by Sebastian Carballo, Philippe Musso, Nicolas Garin, Hajo Müller, Jacques Serratrice, François Mach, David Carballo, Jérôme Stirnemann

    The prognostic value of pulmonary hypertension (PH) estimated by echocardiography in unselected patients with acute decompensated heart failure (ADHF) is poorly studied. Between November 2014 and September 2018, 657 patients were recruited in a prospective registry of ADHF (ClinicalTrials.gov NCT02444416). The probability of pulmonary hypertension was based on European Society of Cardiology (ESC) guidelines for echocardiographic evaluation. The median survival without all-cause mortality or readmission was 7 months. During the median follow-up period of 15 months, there were 450 events including 185 deaths. In multivariate analysis, the hazard ratio (HR) of all-cause mortality or readmission for patients with a high probability of PH was 1.67 (95% CI 1.29–2.17, p < 0.001) as compared to patients with a low or intermediate probability. The left ventricular ejection fraction (LVEF) and right ventricular function (RVF) were not associated with the primary outcome—HR 1.02 (95% CI 0.81–1.29; p = 0.84) and 0.96 (95% CI 0.76–1.23; p = 0.77) respectively. In patients admitted for ADHF, a high probability of PH as evaluated by echocardiography provided the highest independent prognostic value for mortality and readmission, whereas LVEF and RVF were not associated with prognosis. The identification of patients at high risk of PH by non-invasive measurement conveys important prognostic information and may guide management.


  • Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T

    by Lindsey Alexandra Crowe, Gibran Manasseh, Aneta Chmielewski, Anne-Lise Hachulla, Daniel Speicher, Andreas Greiser, Hajo Muller, Thomas de Perrot, Jean-Paul Vallee, Rares Salomir

    Objectives: We demonstrate the use of a Magnetic-Resonance (MR)-compatible ultrasound (US) imaging probe using spatially-resolved Doppler for diagnostic quality cardiovascular MR imaging as an initial step towards hybrid US/MR fetal imaging. Methods: A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional ECG and the proposed spatially-resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic éfalse-triggeredé image was retrospectively processed using Metric Optimized Gating (MOG). Images were scored by expert readers and sharpness, cardiac function and aortic flow were quantified. 4D flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Results. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p=1.00). ECG-, Doppler-triggered and MOG ejection fractions were equivalent (p=1.00), with false-triggered values significantly lower (p0.05). 4D Flow quantification gave consistent results between ECG and Doppler triggering. Conclusion. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. Significance. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible i.e. fetal imaging.


  • TCT-524 3D-Printed Heart Model to Guide LAA closure

    by Stephane Noble, Hajo Müller, Anne-Lise Hachulla

  • Thirty-day Outcome Following CoreValve Evolut R Transcatheter Aortic Valve Implantation: An All-comers Prospective Study

    by Nils Perrin, Marco Roffi, Angela Frei, Anne-Lise Hachulla, Christoph Ellenberger, Hajo Müller, Mustafa Cikirikcioglu, Marc Licker, Stephane Noble


  • Measurement of Left and Right Atrial Volume in Patients Undergoing Ablation for Atrial Arrhythmias: Comparison of a Manual versus Semiautomatic Algorithm of Real Time 3D Echocardiography

    by Hajo Müller, Stéphane Reverdin, Haran Burri, Dipen Shah, René Lerch

    Aims: Real time full‐volume 3D echocardiography (3DE) allows rapid and noninvasive measurement of left (LA) and right atrial (RA) volume without geometric assumptions. Different algorithms from different commercial providers are available. Older software requires manual tracing of endocardial contours. Recently, software with semiautomatic endocardial contour‐finding algorithms has become available, which considerably speeds up the procedure. Our aim was to compare, in the same dataset, both LA and RA volumes determined by an algorithm involving manual tracing to the corresponding volumes obtained by an algorithm with semiautomatic contour detection.Methods: Maximal atrial volumes were measured in 88 patients using a multiplane interpolation method algorithm based on manual planimetry of 8 slices. These volumes were compared with volumes determined by the QLAB 8.1 software using semiautomatic border detection.Results: Linear regression showed excellent correlation between volumes determined by manual and by semiautomatic software for both LA and RA (r2 = 0.90 and 0.89, respectively, P < 0.001). Bland–Altman analysis of manual versus semiautomatic volume determination showed narrow 95% limits of agreement (−15.9 to +12.0 mL for LA volume and −13.9 to +12.2 mL for RA volume) with a minimal bias of −1.9 ± 7.0 mL and −0.8 ± 6.5 mL, respectively, by the semiautomatic method.Conclusion: The semiautomatic border detection method shows excellent correlation for maximal LA and RA volume determination compared to the more time‐consuming, multiplane interpolation method, with only slight underestimation. The results indicate that values of LA and RA volumes obtained by either algorithm can be compared, for example, during follow‐up examinations.