P. G. Merli
P. G. Merli has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Vittorio Morandi
Istituto per la Microelettronica ed i Microsistemi (IMM) – CNR Sede di Bologna, Bologna, Italy
5 shared publications - Andrea Parisini
CNR-IMM
1 shared publication D. Giubertoni
Fondazione Bruno Kessler-irst, via Sommarive 14, Povo (Tn), I-38050, Italy
1 shared publicationF. Corticelli
CNR-IMM Sezione di Bologna, via Gobetti 101, 40129 Bologna, Italy
1 shared publication- F. Ubaldi
Dipartimento di Fisica e Istituto Nazionale per la Fisica della Materia, Universita’ di Bologna, Viale B. Pichat 6/2, 40127 Bologna, Italy
1 shared publication G. Savini
CNR-IMM Sezione di Bologna , via Gobetti 101, 40129 Bologna, Italy
1 shared publication
Latest Publications
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1026
Si Ultra Shallow Junctions Dopant Profiling with ADF-STEM
- 1 January 2007
- Published by Springer Nature in MRS Proceedings
- Vol. 1026
Si Ultra Shallow Junctions Dopant Profiling with ADF-STEM
- 2 August 2005
- Published by American Physical Society (APS) in Physical Review B
- Vol. 72 (8) , 085312
Effects of beam-specimen interaction on the observation of reverse-biasedjunctions by electron interferometryElectron interferometry experiments on straight reverse-biased junctions have been carried out in a transmission electron microscope. The trend of the interference fringes as well as the shape of the interference region are able to give direct information about the phase variation across the junction. Agreement between theory and experiment is obtained by introducing a suitable surface density charge produced by the beam at the interface between the silicon and the native oxide. Also the depletion layer width and the overall electric field topography are strongly modified by the charged layers. The results confirm the main predictions of the improved model in a more reliable way than those obtained through previous out-of-focus observations and point out the active role of the electron beam in the electric characterization of semiconductor devices.- 2 August 2005
- Published by American Physical Society (APS) in Physical Review B
- Vol. 72 (8) , 085312
Effects of beam-specimen interaction on the observation of reverse-biasedjunctions by electron interferometryElectron interferometry experiments on straight reverse-biased junctions have been carried out in a transmission electron microscope. The trend of the interference fringes as well as the shape of the interference region are able to give direct information about the phase variation across the junction. Agreement between theory and experiment is obtained by introducing a suitable surface density charge produced by the beam at the interface between the silicon and the native oxide. Also the depletion layer width and the overall electric field topography are strongly modified by the charged layers. The results confirm the main predictions of the improved model in a more reliable way than those obtained through previous out-of-focus observations and point out the active role of the electron beam in the electric characterization of semiconductor devices.- 4 March 2005
- Published by AIP Publishing in Applied Physics Letters
- Vol. 86 (10) , 101916
Scanning electron microscopy of dopant distribution in semiconductors
We show that, in scanning electron microscopy, it is possible to use the secondary electrons produced by the backscattered electrons to obtain chemical information on the dopant distribution in Sb-implanted silicon. Theoretical investigations and experimental data concur to point out that the resolution of the method is defined by the probe size—values of 1 nm or even lower are possible in the present instruments—while the contrast depends on the electron range and on the boundary conditions. A proper choice of beam energy and boundaries of the doped layer may allow a sensitivity below 1%, suitable to characterize the high-dose near-surface region of the ultrashallow junctions in cross-sectioned bulk specimens.
- 4 March 2005
- Published by AIP Publishing in Applied Physics Letters
- Vol. 86 (10) , 101916
Scanning electron microscopy of dopant distribution in semiconductors
We show that, in scanning electron microscopy, it is possible to use the secondary electrons produced by the backscattered electrons to obtain chemical information on the dopant distribution in Sb-implanted silicon. Theoretical investigations and experimental data concur to point out that the resolution of the method is defined by the probe size—values of 1 nm or even lower are possible in the present instruments—while the contrast depends on the electron range and on the boundary conditions. A proper choice of beam energy and boundaries of the doped layer may allow a sensitivity below 1%, suitable to characterize the high-dose near-surface region of the ultrashallow junctions in cross-sectioned bulk specimens.
- 28 January 2005
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 11 (1) , 97-104
Low-Energy STEM of Multilayers and Dopant Profiles
A conventional scanning electron microscope equipped with a LaB6 source has been modified to operate in a scanning transmission mode. Two detection strategies have been considered, one based on the direct collection of transmitted electrons, the other on the collection of secondary electrons resulting from the conversion of the transmitted ones. Two types of specimens have been mainly investigated: semiconductor multilayers and dopant profiles in As-implanted Si. The results show that the contrast obeys the rules of mass–thickness contrast whereas the resolution is always defined by the probe size independently of specimen thickness and beam broadening. The detection strategy may affect the bright field (light regions look brighter) or dark field (heavy regions look brighter) appearance of the image. Using a direct collection of the transmitted electrons, the contrast can be deduced from the angular distribution of transmitted electrons and their collection angles. When collecting the secondary electrons to explain the image contrast, it is also necessary to take into account the secondary yield dependence on the incidence angle of the transmitted electrons.
- 28 January 2005
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 11 (1) , 97-104
Low-Energy STEM of Multilayers and Dopant Profiles
A conventional scanning electron microscope equipped with a LaB6 source has been modified to operate in a scanning transmission mode. Two detection strategies have been considered, one based on the direct collection of transmitted electrons, the other on the collection of secondary electrons resulting from the conversion of the transmitted ones. Two types of specimens have been mainly investigated: semiconductor multilayers and dopant profiles in As-implanted Si. The results show that the contrast obeys the rules of mass–thickness contrast whereas the resolution is always defined by the probe size independently of specimen thickness and beam broadening. The detection strategy may affect the bright field (light regions look brighter) or dark field (heavy regions look brighter) appearance of the image. Using a direct collection of the transmitted electrons, the contrast can be deduced from the angular distribution of transmitted electrons and their collection angles. When collecting the secondary electrons to explain the image contrast, it is also necessary to take into account the secondary yield dependence on the incidence angle of the transmitted electrons.
- 9 December 2002
- Published by AIP Publishing in Applied Physics Letters
- Vol. 81 (24) , 4535-4537
Images of dopant profiles in low-energy scanning transmission electron microscopy
A scanning electron microscope is used in transmission mode. The image is formed with secondary electrons, collected by the standard detector, resulting from the conversion of transmitted electrons on a circular disk, covered with MgO smoke, located below the thinned specimen, and centered on the optical axis. Operating in this mode, bright-field images of As dopant profiles in Si, having a peak concentrations of 5 and 2.5 at. % and a spatial extension of about 40 nm, have been observed in cross sectioned specimens. The description of the dopant profiles has a resolution of 6 nm as defined by the spot size of the microscope, equipped with a tip, and operating at 30 keV.- 9 December 2002
- Published by AIP Publishing in Applied Physics Letters
- Vol. 81 (24) , 4535-4537
Images of dopant profiles in low-energy scanning transmission electron microscopy
A scanning electron microscope is used in transmission mode. The image is formed with secondary electrons, collected by the standard detector, resulting from the conversion of transmitted electrons on a circular disk, covered with MgO smoke, located below the thinned specimen, and centered on the optical axis. Operating in this mode, bright-field images of As dopant profiles in Si, having a peak concentrations of 5 and 2.5 at. % and a spatial extension of about 40 nm, have been observed in cross sectioned specimens. The description of the dopant profiles has a resolution of 6 nm as defined by the spot size of the microscope, equipped with a tip, and operating at 30 keV.- 1 January 2002