David A. Steinman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David A. Steinman has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Brian K. Rutt
Imaging Research Labs, John P. Robarts Research Institute, London, Ontario, Canada
1 shared publication- David Wayne Holdsworth
Robarts Research Institute, Western University, London, Canada
1 shared publication Emily Y. Wong
Robarts Research Institute (Canada)
1 shared publicationHanif M. Ladak
Imaging Research Labs, John P. Robarts Research Institute, London, Ontario, Canada
1 shared publicationJaques S. Milner
Imaging Research Labs, John P. Robarts Research Institute, London, Ontario, Canada
1 shared publication- Jaques S. Milner
Robarts Research Institute (Canada)
1 shared publication
Latest Publications
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261
Numerical analysis of the hemodynamic effect of plaque ulceration in the stenotic carotid artery bifurcation
The presence of ulceration in carotid artery plaque is an independent risk factor for thromboembolic stroke. However, the associated pathophysiological mechanisms - in particular the mechanisms related to the local hemodynamics in the carotid artery bifurcation - are not well understood. We investigated the effect of carotid plaque ulceration on the local time-varying three-dimensional flow field using computational fluid dynamics (CFD) models of a stenosed carotid bifurcation geometry, with and without the presence of ulceration. CFD analysis of each model was performed with a spatial finite element discretization of over 150,000 quadratic tetrahedral elements and a temporal discretization of 4800 timesteps per cardiac cycle, to adequately resolve the flow field and pulsatile flow, respectively. Pulsatile flow simulations were iterated for five cardiac cycles to allow for cycle-to-cycle analysis following the damping of initial transients in the solution. Comparison between models revealed differences in flow patterns induced by flow exiting from the region of the ulcer cavity, in particular, to the shape, orientation and helicity of the high velocity jet through the stenosis. The stenotic jet in both models exhibited oscillatory motion, but produced higher levels of phase-ensembled turbulence intensity in the ulcerated model. In addition, enhanced out-of-plane recirculation and helical flow was observed in the ulcerated model. These preliminary results suggest that local fluid behaviour may contribute to the thrombogenic risk associated with plaque ulcerations in the stenotic carotid artery bifurcation.
- 26 February 2009
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7261
Numerical analysis of the hemodynamic effect of plaque ulceration in the stenotic carotid artery bifurcation
The presence of ulceration in carotid artery plaque is an independent risk factor for thromboembolic stroke. However, the associated pathophysiological mechanisms - in particular the mechanisms related to the local hemodynamics in the carotid artery bifurcation - are not well understood. We investigated the effect of carotid plaque ulceration on the local time-varying three-dimensional flow field using computational fluid dynamics (CFD) models of a stenosed carotid bifurcation geometry, with and without the presence of ulceration. CFD analysis of each model was performed with a spatial finite element discretization of over 150,000 quadratic tetrahedral elements and a temporal discretization of 4800 timesteps per cardiac cycle, to adequately resolve the flow field and pulsatile flow, respectively. Pulsatile flow simulations were iterated for five cardiac cycles to allow for cycle-to-cycle analysis following the damping of initial transients in the solution. Comparison between models revealed differences in flow patterns induced by flow exiting from the region of the ulcer cavity, in particular, to the shape, orientation and helicity of the high velocity jet through the stenosis. The stenotic jet in both models exhibited oscillatory motion, but produced higher levels of phase-ensembled turbulence intensity in the ulcerated model. In addition, enhanced out-of-plane recirculation and helical flow was observed in the ulcerated model. These preliminary results suggest that local fluid behaviour may contribute to the thrombogenic risk associated with plaque ulcerations in the stenotic carotid artery bifurcation.
- 29 March 2002
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 124 (2) , 166-175
On Assessing the Quality of Particle Tracking Through Computational Fluid Dynamic Models
Quantification of particle deposition patterns, transit times, and shear exposure is important for computational fluid dynamic (CFD) studies involving respiratory and arterial models. To numerically compute such path-dependent quantities, it is necessary to employ a Lagrangian approach where particles are tracked through a pre-computed velocity field. However, it is difficult to determine in advance whether a particular velocity field is sufficiently resolved for the purposes of tracking particles accurately. Towards this end, we propose the use of volumetric residence time (VRT)—previously defined for 2-D studies of platelet activation and here extended to more physiologically relevant 3-D models—as a means of quantifying whether a volume of Lagrangian fluid elements (LFE’s) seeded uniformly and contiguously at the model inlet remains uniform throughout the flow domain. Such “Lagrangian mass conservation” is shown to be satisfied when VRT=1 throughout the model domain. To demonstrate this novel concept, we computed maps of VRT and particle deposition in 3-D steady flow models of a stenosed carotid bifurcation constructed with one adaptively refined and three nominally uniform finite element meshes of increasing element density. A key finding was that uniform VRT could not be achieved for even the most resolved meshes and densest LFE seeding, suggesting that care should be taken when extracting quantitative information about path-dependent quantities. The VRT maps were found to be useful for identifying regions of a mesh that were under-resolved for such Lagrangian studies, and for guiding the construction of more adequately resolved meshes.
- 29 March 2002
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 124 (2) , 166-175
On Assessing the Quality of Particle Tracking Through Computational Fluid Dynamic Models
Quantification of particle deposition patterns, transit times, and shear exposure is important for computational fluid dynamic (CFD) studies involving respiratory and arterial models. To numerically compute such path-dependent quantities, it is necessary to employ a Lagrangian approach where particles are tracked through a pre-computed velocity field. However, it is difficult to determine in advance whether a particular velocity field is sufficiently resolved for the purposes of tracking particles accurately. Towards this end, we propose the use of volumetric residence time (VRT)—previously defined for 2-D studies of platelet activation and here extended to more physiologically relevant 3-D models—as a means of quantifying whether a volume of Lagrangian fluid elements (LFE’s) seeded uniformly and contiguously at the model inlet remains uniform throughout the flow domain. Such “Lagrangian mass conservation” is shown to be satisfied when VRT=1 throughout the model domain. To demonstrate this novel concept, we computed maps of VRT and particle deposition in 3-D steady flow models of a stenosed carotid bifurcation constructed with one adaptively refined and three nominally uniform finite element meshes of increasing element density. A key finding was that uniform VRT could not be achieved for even the most resolved meshes and densest LFE seeding, suggesting that care should be taken when extracting quantitative information about path-dependent quantities. The VRT maps were found to be useful for identifying regions of a mesh that were under-resolved for such Lagrangian studies, and for guiding the construction of more adequately resolved meshes.
- Open Access
- 20 December 2001
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (1) , 149-159
Reconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI
A thorough understanding of the relationship between local hemodynamics and plaque progression has been hindered by an inability to prospectively monitor these factors in vivo in humans. In this study a novel approach for noninvasively reconstructing artery wall thickness and local hemodynamics at the human carotid bifurcation is presented. Three‐dimensional (3D) models of the lumen and wall boundaries, from which wall thickness can be measured, were reconstructed from black‐blood magnetic resonance imaging (MRI). Along with time‐varying inlet/outlet flow rates measured via phase contrast (PC) MRI, the lumen boundary was used as input for computational fluid dynamic (CFD) simulation of the subject‐specific flow patterns and wall shear stresses (WSSs). Results from a 59‐year‐old subject with early, asymptomatic carotid artery disease show good agreement between simulated and measured velocities, and demonstrate a correspondence between wall thickening and low and oscillating shear at the carotid bulb. High shear at the distal internal carotid artery (ICA) was also colocalized with higher WSS; however, a quantitative general relationship between WSS and wall thickness was not found. Similar results were obtained from a 23‐year‐old normal subject. These findings represent the first direct comparison of hemodynamic variables and wall thickness at the carotid bifurcation of human subjects. The noninvasive nature of this image‐based modeling approach makes it ideal for carrying out future prospective studies of hemodynamics and plaque development or progression in otherwise healthy subjects.
- 20 December 2001
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (1) , 149-159
Open AccessReconstruction of carotid bifurcation hemodynamics and wall thickness using computational fluid dynamics and MRI
A thorough understanding of the relationship between local hemodynamics and plaque progression has been hindered by an inability to prospectively monitor these factors in vivo in humans. In this study a novel approach for noninvasively reconstructing artery wall thickness and local hemodynamics at the human carotid bifurcation is presented. Three‐dimensional (3D) models of the lumen and wall boundaries, from which wall thickness can be measured, were reconstructed from black‐blood magnetic resonance imaging (MRI). Along with time‐varying inlet/outlet flow rates measured via phase contrast (PC) MRI, the lumen boundary was used as input for computational fluid dynamic (CFD) simulation of the subject‐specific flow patterns and wall shear stresses (WSSs). Results from a 59‐year‐old subject with early, asymptomatic carotid artery disease show good agreement between simulated and measured velocities, and demonstrate a correspondence between wall thickening and low and oscillating shear at the carotid bulb. High shear at the distal internal carotid artery (ICA) was also colocalized with higher WSS; however, a quantitative general relationship between WSS and wall thickness was not found. Similar results were obtained from a 23‐year‐old normal subject. These findings represent the first direct comparison of hemodynamic variables and wall thickness at the carotid bifurcation of human subjects. The noninvasive nature of this image‐based modeling approach makes it ideal for carrying out future prospective studies of hemodynamics and plaque development or progression in otherwise healthy subjects.