Kazuhiro Matsuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kazuhiro Matsuda has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Masanori Inui
Graduate School of Advanced Science and Engineering, Hiroshima University 1 , Higashi-Hiroshima, Hiroshima 739-8521
5 shared publications Kozaburo Tamura
Graduate School of Engineering, Kyoto University, Kyoto 606-8501, Japan
3 shared publicationsDaisuke Ishikawa
RIKEN SPring-8 Center
1 shared publicationK. Tamura
Department of Materials Science and Engineering, Kyoto University, Kyoto 606-8501, Japan
1 shared publication- Kenji Tamura
Japan Environment and Children's Study Programme Office, Health and Environmental Risk Division, National Institute for Environmental Studies, Tsukuba, Japan
1 shared publication Masahiro Katoh
Material Research Department, Allied Material Corporation, Iwasekoshi-Machi 2, Toyama 931-8543, Japan
1 shared publication
Latest Publications
- Open Access
- 23 August 2008
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 64 (a1) , C64
Structural studies of expanded fluid alkali metals
- 23 August 2008
- Published by International Union of Crystallography (IUCr) in Acta Crystallographica Section A Foundations of Crystallography
- Vol. 64 (a1) , C64
Open AccessStructural studies of expanded fluid alkali metals
- 27 February 2007
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 98 (9) , 096401
Instability of the Electron Gas in an Expanding Metal
We have measured x-ray diffraction and small-angle x-ray scattering of fluid rubidium by reducing electron density down to the range where the compressibility of the interacting electron gas has been theoretically predicted to become negative. Negative compressibility is closely associated with a negative value of the static dielectric function, which makes the screened Coulomb interaction among like charges overall attractive. It was clearly observed that the interatomic distance decreases in spite of the fact that mean interatomic distance increases with expansion, suggesting that an attractive interaction among like charges, ions in this case, is enhanced. These findings indicate that the observed structural features are evidence of the compressional instability of the 3D electron gas.
- 27 February 2007
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 98 (9) , 096401
Instability of the Electron Gas in an Expanding Metal
We have measured x-ray diffraction and small-angle x-ray scattering of fluid rubidium by reducing electron density down to the range where the compressibility of the interacting electron gas has been theoretically predicted to become negative. Negative compressibility is closely associated with a negative value of the static dielectric function, which makes the screened Coulomb interaction among like charges overall attractive. It was clearly observed that the interatomic distance decreases in spite of the fact that mean interatomic distance increases with expansion, suggesting that an attractive interaction among like charges, ions in this case, is enhanced. These findings indicate that the observed structural features are evidence of the compressional instability of the 3D electron gas.
- Open Access
- 12 January 2006
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 7 (6) , 483-489
Structural studies of expanded fluid rubidium up to the supercritical regions
X-ray diffraction measurements have been carried out for fluid rubidium up to enormous high temperatures and pressures beyond the liquid–vapor critical point (Tc=2017 K, Pc=12.45 MPa) using synchrotron radiation at SPring-8. We have developed a new sample cell made of molybdenum which is resistant to highly corrosive nature of hot alkali metals. Single crystalline molybdenum electrolytically thinned to 30 μm was used as X-ray windows of the cell. The crystal orientation of the disks was controlled to avoid the appearance of Bragg peaks from the cell in the diffraction spectra. All parts of the cell were assembled and brazed together using a high-temperature Ru–Mo alloy. The use of single crystal contributes to reduce the background noise from the cell and made it possible to achieve stable and precise measurements at the supercritical region of fluid rubidium.
- 12 January 2006
- Published by Taylor & Francis in Science and Technology of Advanced Materials
- Vol. 7 (6) , 483-489
Open AccessStructural studies of expanded fluid rubidium up to the supercritical regions
X-ray diffraction measurements have been carried out for fluid rubidium up to enormous high temperatures and pressures beyond the liquid–vapor critical point (Tc=2017 K, Pc=12.45 MPa) using synchrotron radiation at SPring-8. We have developed a new sample cell made of molybdenum which is resistant to highly corrosive nature of hot alkali metals. Single crystalline molybdenum electrolytically thinned to 30 μm was used as X-ray windows of the cell. The crystal orientation of the disks was controlled to avoid the appearance of Bragg peaks from the cell in the diffraction spectra. All parts of the cell were assembled and brazed together using a high-temperature Ru–Mo alloy. The use of single crystal contributes to reduce the background noise from the cell and made it possible to achieve stable and precise measurements at the supercritical region of fluid rubidium.
- 1 January 2006
- Published by The Crystallographic Society of Japan in Nihon Kessho Gakkaishi
- Vol. 48 (1) , 76-80
Small Angle Scattering of Supercritical Metallic Fluids Using High Energy X-rays
Small angle X-ray scattering (SAXS) measurements for expanded fluid Hg have been carried out in wide density region including the metal-non-metal (M-NM) transition region at 9.0g cm-3and the liquid-vapor critical region at 5.8g cm-3using synchrotron radiation at SPring-8. We could observe the liquid-vapor critical scattering intensity in fluid Hg with good statistics and also SAXS intensity in the M-NM transition region. The latter result suggests that characteristic fluctuations are induced in the M-NM transition in expanded fluid Hg.
- 1 January 2006
- Published by The Crystallographic Society of Japan in Nihon Kessho Gakkaishi
- Vol. 48 (1) , 76-80
Small Angle Scattering of Supercritical Metallic Fluids Using High Energy X-rays
Small angle X-ray scattering (SAXS) measurements for expanded fluid Hg have been carried out in wide density region including the metal-non-metal (M-NM) transition region at 9.0g cm-3and the liquid-vapor critical region at 5.8g cm-3using synchrotron radiation at SPring-8. We could observe the liquid-vapor critical scattering intensity in fluid Hg with good statistics and also SAXS intensity in the M-NM transition region. The latter result suggests that characteristic fluctuations are induced in the M-NM transition in expanded fluid Hg.
- 18 February 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (3) , 709-712
Molybdenum cell for x-ray diffraction measurements of fluid alkali metals at high temperatures and high pressures
We have developed a sample cell for x-ray diffraction measurements of fluid alkali metals at high temperatures and high pressures. All parts of the cell are made of molybdenum which is resistant to the chemical corrosion of alkali metals. Single crystalline molybdenum disks electrolytically thinned down to 40 μm were used as the walls of the cell through which x rays pass. The crystal orientation of the disks was controlled in order to reduce the background from the cell. All parts of the cell were assembled and brazed together using a high-temperature Ru–Mo alloy. Energy dispersive x-ray diffraction measurements have been successfully carried out for fluid rubidium up to 1973 K and 16.2 MPa. The obtained demonstrates the applicability of the molybdenum cell to x-ray diffraction measurements of fluid alkali metals at high temperatures and high pressures.- 18 February 2004
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 75 (3) , 709-712
Molybdenum cell for x-ray diffraction measurements of fluid alkali metals at high temperatures and high pressures
We have developed a sample cell for x-ray diffraction measurements of fluid alkali metals at high temperatures and high pressures. All parts of the cell are made of molybdenum which is resistant to the chemical corrosion of alkali metals. Single crystalline molybdenum disks electrolytically thinned down to 40 μm were used as the walls of the cell through which x rays pass. The crystal orientation of the disks was controlled in order to reduce the background from the cell. All parts of the cell were assembled and brazed together using a high-temperature Ru–Mo alloy. Energy dispersive x-ray diffraction measurements have been successfully carried out for fluid rubidium up to 1973 K and 16.2 MPa. The obtained demonstrates the applicability of the molybdenum cell to x-ray diffraction measurements of fluid alkali metals at high temperatures and high pressures.