Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Aniket A. Saoji has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Pure-Tone Masking Patterns for Monopolar and Phantom Electrical Stimulation in Cochlear Implants

    by Aniket A. Saoji, Kanthaiah Koka, Leonid M. Litvak, Charles C. Finley

    Monopolar stimulation of the most apical electrode produces the lowest pitch sensation in cochlear implants clinically. A phantom electrode that uses out-of-phase electrical stimulation between the most apical and the neighboring basal electrode can produce a lower pitch sensation than that associated with the most apical electrode. However, because of the absence of contacts beyond the apical tip of the array, the ability to assess the spread of electrical excitation associated with phantom stimulation is limited in the typical cochlear implant subject with no residual hearing. In the present study, the spread of electrical excitation associated with monopolar and phantom stimulation of the most apical electrode was assessed using electrical masking of acoustic thresholds in cochlear implant subjects with residual, low-frequency, acoustic hearing. Eight subjects with an Advanced Bionics cochlear implant and residual hearing in the implanted ear participated in this study (nine ears in total). Unmasked and masked thresholds for acoustic pure tones were measured at 125, 250, 500, 750, 1000, and 2000 Hz in the presence of monopolar and phantom electrode stimulation presented at the apical-most end of the array. The current compensation for phantom electrode stimulation was fixed at 50%. The two electrical maskers were loudness balanced. Differences between the unmasked and masked acoustic thresholds can be attributed to (1) the electrical stimulus–induced interference in the transduction/conduction of the acoustic signal through cochlear periphery and the auditory nerve and/or (2) masking at the level of the central auditory system. The results show a significant elevation in pure-tone thresholds in the presence of the monopolar and phantom electrical maskers. The unmasked thresholds were subtracted from the masked thresholds to derive masking patterns as a function of the acoustic probe frequency. The masking patterns show that phantom stimulation was able to produce more masking than that associated with the monopolar stimulation of the most apical electrode. These results suggest that for some cochlear implant subjects, phantom electrode stimulation can shift the neural stimulation pattern more apically in the cochlea, which is consistent with reports that phantom electrode stimulation produces lower pitch sensations than those associated with monopolar stimulation of the most apical electrode alone.


  • Excitation Patterns of Simultaneous and Sequential Dual-Electrode Stimulation in Cochlear Implant Recipients

    by Aniket A. Saoji, Leonid M. Litvak, Michelle L. Hughes

    Both simultaneous (SI) and sequential stimulation of intracochlear electrodes can be used to generate pitches that are intermediate to the physical electrodes (PEs). The goal of this study was to compare the spread of neural excitation for SI and sequential dual-electrode stimulation with the spread of neural excitation for the intermediate electrode using electrically evoked compound action potentials. Seven Advanced Bionics cochlear implant users with either CII or HiRes 90k implant and HiFocus 1 or HiFocus 1j electrode array participated in this study. A masker-probe subtraction method was used to derive neural excitation patterns for SI nonadjacent dual-electrode stimulation, apical and basal-first sequential nonadjacent dual-electrode stimulation, and the intermediate PE. For apical-first sequential (SEa) stimulation, the masker pulse on the apical electrode immediately preceded the masker pulse on the basal electrode, and vice versa for basal-first sequential stimulation (SEb). The electrodes used for dual-electrode stimulation were separated by an intermediate PE, which represents a spatial distance of approximately 2 mm. Current levels necessary to achieve comfortable loudness were determined for each masker and probe stimulus. During the evoked compound action potential measurements, the masker was fixed in location, whereas the probe was varied across a subset of electrodes in the array. Neural responses were calculated by subtracting the response to the probe from the masked response. Neural excitation patterns were normalized to their peak and analyzed in terms of their area and center of gravity. The area and center of gravity for SI nonadjacent dual-electrode stimulation were similar to those of the intermediate PE. In contrast, the area for the two modes of sequential nonadjacent dual-electrode (SEa and SEb) stimulation differed significantly from the intermediate PE. The center of gravity for SEa stimulation also differed significantly from the intermediate PE, whereas there was no significant difference in the center of gravity between SEb stimulation and the intermediate PE. Peripheral neural activation patterns suggest a similar spread of excitation for SI dual-electrode stimulation and the intermediate PE. The spread of excitation associated with sequential dual-electrode stimulation is generally different from the intermediate PE, and it varies depending on the order of the sequential pulses.


  • Spectral modulation masking patterns reveal tuning to spectral envelope frequency

    by Aniket A. Saoji, David A. Eddins

    Auditory processing appears to include a series of domain-specific filtering operations that include tuning in the audio-frequency domain, followed by tuning in the temporal modulation domain, and perhaps tuning in the spectral modulation domain. To explore the possibility of tuning in the spectral modulation domain, a masking experiment was designed to measure masking patterns in the spectral modulation domain. Spectral modulation transfer functions (SMTFs) were measured for modulation frequencies from 0.25 to 14 cycles/octave superimposed on noise carriers either one octave (800-1600 Hz, 6400-12,800 Hz) or six octaves wide (200-12,800 Hz). The resulting SMTFs showed maximum sensitivity to modulation between 1 and 3 cycles/octave with reduced sensitivity above and below this region. Masked spectral modulation detection thresholds were measured for masker modulation frequencies of 1, 3, and 5 cycles/octave with a fixed modulation depth of 15 dB. The masking patterns obtained for each masker frequency and carrier band revealed tuning (maximum masking) near the masker frequency, which is consistent with the theory that spectral envelope perception is governed by a series of spectral modulation channels tuned to different spectral modulation frequencies.