Knut H. Schrøder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Knut H. Schrøder has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Øyvind Mikkelsen
Norwegian University of Science and Technology, Department of Chemistry, 7491 Trondheim, Norway
6 shared publications - Atle Hannisdal
Department of Food Technology, Faculty of Food Science and Medical Technology, Sør-Trøndelag University College, N-7004 Trondheim, Norway
1 shared publication Silje M. Skogvold
Norwegian University of Science and Technology Department of Chemistry, N‐7491 Trondheim, Norway
1 shared publication
Latest Publications
- 1 January 2007
- Published by Institute of Organic Chemistry & Biochemistry in Collection of Czechoslovak Chemical Communications
- Vol. 72 (9) , 1207-1213
Analysis of Nicotine in Antismoking Pharmaceutical Products by Differential Pulse Polarography and Voltammetry
A fast and simple differential pulse polarographic method was developed for analysis of nicotine in various pharmaceutical formulations (chewing gum, tablets (drops) and patches). This method requires a simple liquid-liquid extraction procedure for chewing gum and patches, or a direct dilution in supporting electrolyte for tablets before polarographic analysis. The polarographic analysis was done in a Britton-Robinson buffer (pH 6.2) as supporting electrolyte. The multimode electrode from Metrohm was used as working electrode (dropping mercury electrode). This method was applied to the determination of the nicotine content in chewing gum, tablets and patches by using the standard addition method. The results are in good agreement with the content declared by the manufacturer. The method is fast, simple and reliable, and it is a complementary method to the chromatographic method being used today for quantitative analysis of nicotine in pharmaceutical formulations. The limit of quantification is assumed to be far below 0.1 mg/l in the polarographic vessel. The method uses simple dilution and/or extraction procedures for sample preparation before polarographic analysis. It is also shown that it is possible to use a glassy carbon electrode with a mercury film (MTFE electrode) for the determination of nicotine in antismoking pharmaceutical products.
- 1 January 2007
- Published by Institute of Organic Chemistry & Biochemistry in Collection of Czechoslovak Chemical Communications
- Vol. 72 (9) , 1207-1213
Analysis of Nicotine in Antismoking Pharmaceutical Products by Differential Pulse Polarography and Voltammetry
A fast and simple differential pulse polarographic method was developed for analysis of nicotine in various pharmaceutical formulations (chewing gum, tablets (drops) and patches). This method requires a simple liquid-liquid extraction procedure for chewing gum and patches, or a direct dilution in supporting electrolyte for tablets before polarographic analysis. The polarographic analysis was done in a Britton-Robinson buffer (pH 6.2) as supporting electrolyte. The multimode electrode from Metrohm was used as working electrode (dropping mercury electrode). This method was applied to the determination of the nicotine content in chewing gum, tablets and patches by using the standard addition method. The results are in good agreement with the content declared by the manufacturer. The method is fast, simple and reliable, and it is a complementary method to the chromatographic method being used today for quantitative analysis of nicotine in pharmaceutical formulations. The limit of quantification is assumed to be far below 0.1 mg/l in the polarographic vessel. The method uses simple dilution and/or extraction procedures for sample preparation before polarographic analysis. It is also shown that it is possible to use a glassy carbon electrode with a mercury film (MTFE electrode) for the determination of nicotine in antismoking pharmaceutical products.
- 10 January 2005
- Published by Wiley in Electroanalysis
- Vol. 17 (5-6) , 431-439
Continouos Heavy Metal Monitoring System for Application in River and Seawater
- 10 January 2005
- Published by Wiley in Electroanalysis
- Vol. 17 (5-6) , 431-439
Continouos Heavy Metal Monitoring System for Application in River and Seawater
- 11 March 2004
- Published by Wiley in Electroanalysis
- Vol. 16 (5) , 386-390
Voltammetric Monitoring of Bivalent Iron in Waters and Effluents, Using a Dental Amalgam Sensor Electrode. Some Preliminary Results
A very sensitive method for detection of iron(II) in the ng/L range with a deposition time of 180 s by use of differential pulse anodic stripping voltammetry on a novel dental amalgam electrode is introduced and tested in different supporting media. A well‐defined peak for the oxidation of iron metal to ferrous ion was observed around.
- 11 March 2004
- Published by Wiley in Electroanalysis
- Vol. 16 (5) , 386-390
Voltammetric Monitoring of Bivalent Iron in Waters and Effluents, Using a Dental Amalgam Sensor Electrode. Some Preliminary Results
A very sensitive method for detection of iron(II) in the ng/L range with a deposition time of 180 s by use of differential pulse anodic stripping voltammetry on a novel dental amalgam electrode is introduced and tested in different supporting media. A well‐defined peak for the oxidation of iron metal to ferrous ion was observed around.
- 26 May 2003
- Published by Wiley in Electroanalysis
- Vol. 15 (8) , 679-687
Amalgam Electrodes for Electroanalysis
Liquid mercury is a unique material for the indicator electrode in voltammetry. One reason for this is the high overvoltage for hydrogen formation, thus extending the actual potential window. Diluted amalgams are important reaction products in voltammetric (polarographic) processes, however liquid amalgams are rarely used directly as electrode material for analytical purposes. Because of the fact that voltammetry is very suitable for field and remote monitoring, issues concerning the use of mercury electrodes in environmental analyses have led to considerable research effort aimed at finding alternative tools with acceptable performance. Solid electrodes are such alternatives. Different types of electrodes are reviewed. In particular, solid amalgam electrodes are very promising, with acceptable low toxicity to be used for field measurements. Solid amalgam electrodes are easy and cheap to construct and are stable over a reasonable time up to several weeks. Assessment of the toxicity risk and the long time stability for remote and unattended monitoring is discussed. The differences between solid dental amalgam electrodes, made by using techniques known from dental clinical practice, and mercury film or mercury layer electrodes on solid substrates are reviewed. In particular the dental technique for constructing solid amalgam electrodes gives advantage because it's fast and inexpensive. Also the technique for making dental amalgam has been explored and optimized over years by dentists, giving advantage when the same technique is used for constructing electrodes. Dental amalgam electrodes has been found to act similar to a silver electrodes, but with high overvoltage towards hydrogen. This make it possible to use the dental amalgam electrode for detection of zinc, cobalt and nickel in additions to other metals like lead, copper, thallium, cadmium, bismuth, iron etc. Also the use for reducible organic compounds is expected to be promising.
- 26 May 2003
- Published by Wiley in Electroanalysis
- Vol. 15 (8) , 679-687
Amalgam Electrodes for Electroanalysis
Liquid mercury is a unique material for the indicator electrode in voltammetry. One reason for this is the high overvoltage for hydrogen formation, thus extending the actual potential window. Diluted amalgams are important reaction products in voltammetric (polarographic) processes, however liquid amalgams are rarely used directly as electrode material for analytical purposes. Because of the fact that voltammetry is very suitable for field and remote monitoring, issues concerning the use of mercury electrodes in environmental analyses have led to considerable research effort aimed at finding alternative tools with acceptable performance. Solid electrodes are such alternatives. Different types of electrodes are reviewed. In particular, solid amalgam electrodes are very promising, with acceptable low toxicity to be used for field measurements. Solid amalgam electrodes are easy and cheap to construct and are stable over a reasonable time up to several weeks. Assessment of the toxicity risk and the long time stability for remote and unattended monitoring is discussed. The differences between solid dental amalgam electrodes, made by using techniques known from dental clinical practice, and mercury film or mercury layer electrodes on solid substrates are reviewed. In particular the dental technique for constructing solid amalgam electrodes gives advantage because it's fast and inexpensive. Also the technique for making dental amalgam has been explored and optimized over years by dentists, giving advantage when the same technique is used for constructing electrodes. Dental amalgam electrodes has been found to act similar to a silver electrodes, but with high overvoltage towards hydrogen. This make it possible to use the dental amalgam electrode for detection of zinc, cobalt and nickel in additions to other metals like lead, copper, thallium, cadmium, bismuth, iron etc. Also the use for reducible organic compounds is expected to be promising.
- 29 April 2002
- Published by Elsevier in Analytica Chimica Acta
- Vol. 458 (1) , 249-256
Voltammetry using a dental amalgam electrode for heavy metal monitoring of wines and spirits
- 29 April 2002
- Published by Elsevier in Analytica Chimica Acta
- Vol. 458 (1) , 249-256
Voltammetry using a dental amalgam electrode for heavy metal monitoring of wines and spirits
- 1 May 1999
- Published by Wiley in Electroanalysis
- Vol. 11 (6) , 401-405
Sensitivity Enhancements in Stripping Voltammetry from Exposure to Low Frequency Sound
- 1 May 1999
- Published by Wiley in Electroanalysis
- Vol. 11 (6) , 401-405
Sensitivity Enhancements in Stripping Voltammetry from Exposure to Low Frequency Sound