Zahid Amin
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zahid Amin has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
David A. Danford
2 shared publicationsDoff B. McElhinney
2 shared publicationsFrank L. Hanley
2 shared publicationsJohn Lof
2 shared publicationsCarlos A.C. Pedra
Joint Division of Pediatric Cardiology, University of Nebraska and Creighton University, Children's Hospital Omaha, Omaha, Nebraska
1 shared publicationCarsten Rickers
University Hospital, Eppendorf, Germany
1 shared publication
Latest Publications
- 25 October 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (5) , 778-787
Transcatheter closure of secundum atrial septal defects
- 25 October 2006
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 68 (5) , 778-787
Transcatheter closure of secundum atrial septal defects
- 1 February 2006
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 131 (2) , 427-432
Robotically assisted perventricular closure of perimembranous ventricular septal defects: Preliminary results in Yucatan pigs
- 1 February 2006
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 131 (2) , 427-432
Robotically assisted perventricular closure of perimembranous ventricular septal defects: Preliminary results in Yucatan pigs
- 22 November 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 63 (4) , 496-502
Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk
The objectives of this study were to identify possible risk factors that may lead to erosion of the Amplatzer septal occluder (ASO) and recommend ways to minimize future risk. There have been rare occurrences of adverse events with development of pericardial effusion after ASO placement. Identification of high‐risk cases, early recognition, and prompt intervention may minimize the future risks of adverse events. In all patients who developed hemodynamic compromise after ASO placement, echocardiograms (pre‐, intra‐, and postprocedure), atrial septal defect (ASD) size (nonstretched, stretched), size of the device used, cineangiograms, and operative records were reviewed by a panel selected by AGA Medical Corporation. The findings were compared to the premarket approval data obtained from FDA‐approved clinical trials that were conducted in the United States, before the device was approved. A total of 28 cases (14 in United States) of adverse events were reported to AGA Medical. All erosions occurred at the dome of the atria, near the aortic root. Deficient aortic rim was seen in 89% and the defect described as high ASD, suggesting deficient superior rim. The device to unstretched ASD ratio was significantly larger in the adverse event group when compared to the FDA trial group. The incidence of device erosion in the United States was 0.1%. The risk of device erosion with ASO is low and complications can be decreased by identifying high‐risk patients and following them closely. Patients with deficient aortic rim and/or superior rim may be at higher risk for device erosion. Oversized ASO may increase the risk of erosion. The defect should not be overstretched during balloon sizing. Patients with small pericardial effusion at 24 hr should have closer follow‐up.Catheter Cardiovasc Interv 2004;63:496–502.
- 22 November 2004
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 63 (4) , 496-502
Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk
The objectives of this study were to identify possible risk factors that may lead to erosion of the Amplatzer septal occluder (ASO) and recommend ways to minimize future risk. There have been rare occurrences of adverse events with development of pericardial effusion after ASO placement. Identification of high‐risk cases, early recognition, and prompt intervention may minimize the future risks of adverse events. In all patients who developed hemodynamic compromise after ASO placement, echocardiograms (pre‐, intra‐, and postprocedure), atrial septal defect (ASD) size (nonstretched, stretched), size of the device used, cineangiograms, and operative records were reviewed by a panel selected by AGA Medical Corporation. The findings were compared to the premarket approval data obtained from FDA‐approved clinical trials that were conducted in the United States, before the device was approved. A total of 28 cases (14 in United States) of adverse events were reported to AGA Medical. All erosions occurred at the dome of the atria, near the aortic root. Deficient aortic rim was seen in 89% and the defect described as high ASD, suggesting deficient superior rim. The device to unstretched ASD ratio was significantly larger in the adverse event group when compared to the FDA trial group. The incidence of device erosion in the United States was 0.1%. The risk of device erosion with ASO is low and complications can be decreased by identifying high‐risk patients and following them closely. Patients with deficient aortic rim and/or superior rim may be at higher risk for device erosion. Oversized ASO may increase the risk of erosion. The defect should not be overstretched during balloon sizing. Patients with small pericardial effusion at 24 hr should have closer follow‐up.Catheter Cardiovasc Interv 2004;63:496–502.
- 1 January 2004
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 127 (1) , 234-241
Intraoperative device closure of perimembranous ventricular septal defects without cardiopulmonary bypass: Preliminary results with the perventricular technique
Perimembranous (or conoventricular) ventricular septal defects (PMVSDs) are among the most common congenital cardiac malformations.1 x 1 Mitchell, S.C., Korones, S.B., and Berendes, H.W. Congenital heart disease I 56,109 births. Circulation. 1971; 43: 323–332 Crossref | PubMed | Scopus (749) | Google Scholar See all References , 2 x 2 Kidd, L., Driscoll, D.J., Gersony, W.M. et al. Second natural history study of congenital heart defects (results of treatment of patients with ventricular septal defects) . Circulation. 1993; 87: 138–151 Google Scholar See all References Closure is routinely performed with the patient undergoing cardiopulmonary bypass (CPB), with excellent results.2 x 2 Kidd, L., Driscoll, D.J., Gersony, W.M. et al. Second natural history study of congenital heart defects (results of treatment of patients with ventricular septal defects) . Circulation. 1993; 87: 138–151 Google Scholar See all References , 3 x 3 Rudolph AM. Ventricular septal defect. In: Rudolph AM, editor. Congenital diseases of the heart: clinical-physiological considerations. 2nd ed. Armonk, NY: Futura; 2000. p. 197-244 Google Scholar See all References , 4 x 4 Backers, C.L., Winters, R.C., Zales, V.R. et al. The restrictive ventricular septal defect (how small is too small to close?) . Ann Thorac Surg. 1993; 56: 10–14 Google Scholar See all References CPB and sternotomy are important factors that might lead to increased postoperative morbidity, prolonged hospital stay, and possible late neurocognitive impairment.5 x 5 Rose, E.A. Off-Pump coronary artery bypass surgery. N Engl J Med. 2003; 348: 379–380 Crossref | PubMed | Scopus (35) | Google Scholar See all References The long-term effects of CPB remain elusive, and its effects are more pronounced in infants than in patients of older age.6 x 6 Kern FH, Hickey PR. The effects of cardiopulmonary bypass on the brain. In: Jonas RA, editor. Cardiopulmonary bypass in neonates, infants and young children. 1st ed. Boston: Blackwell Science; 1994. p. 263-78 Google Scholar See all References We describe a new technique to close PMVSDs in which the defects were closed under echocardiographic guidance without CPB.
- 1 January 2004
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 127 (1) , 234-241
Intraoperative device closure of perimembranous ventricular septal defects without cardiopulmonary bypass: Preliminary results with the perventricular technique
Perimembranous (or conoventricular) ventricular septal defects (PMVSDs) are among the most common congenital cardiac malformations.1 x 1 Mitchell, S.C., Korones, S.B., and Berendes, H.W. Congenital heart disease I 56,109 births. Circulation. 1971; 43: 323–332 Crossref | PubMed | Scopus (749) | Google Scholar See all References , 2 x 2 Kidd, L., Driscoll, D.J., Gersony, W.M. et al. Second natural history study of congenital heart defects (results of treatment of patients with ventricular septal defects) . Circulation. 1993; 87: 138–151 Google Scholar See all References Closure is routinely performed with the patient undergoing cardiopulmonary bypass (CPB), with excellent results.2 x 2 Kidd, L., Driscoll, D.J., Gersony, W.M. et al. Second natural history study of congenital heart defects (results of treatment of patients with ventricular septal defects) . Circulation. 1993; 87: 138–151 Google Scholar See all References , 3 x 3 Rudolph AM. Ventricular septal defect. In: Rudolph AM, editor. Congenital diseases of the heart: clinical-physiological considerations. 2nd ed. Armonk, NY: Futura; 2000. p. 197-244 Google Scholar See all References , 4 x 4 Backers, C.L., Winters, R.C., Zales, V.R. et al. The restrictive ventricular septal defect (how small is too small to close?) . Ann Thorac Surg. 1993; 56: 10–14 Google Scholar See all References CPB and sternotomy are important factors that might lead to increased postoperative morbidity, prolonged hospital stay, and possible late neurocognitive impairment.5 x 5 Rose, E.A. Off-Pump coronary artery bypass surgery. N Engl J Med. 2003; 348: 379–380 Crossref | PubMed | Scopus (35) | Google Scholar See all References The long-term effects of CPB remain elusive, and its effects are more pronounced in infants than in patients of older age.6 x 6 Kern FH, Hickey PR. The effects of cardiopulmonary bypass on the brain. In: Jonas RA, editor. Cardiopulmonary bypass in neonates, infants and young children. 1st ed. Boston: Blackwell Science; 1994. p. 263-78 Google Scholar See all References We describe a new technique to close PMVSDs in which the defects were closed under echocardiographic guidance without CPB.
- Open Access
- 28 April 2003
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 16 (2) , 165-169
Extension of Transcatheter Coil Occlusion to the Treatment of Complex Coronary Fistulas
Coronary fistulas can be a source of myocardial Ischemia when they are large. In this case series, we describe four complex coronary fistulas treated by transcatheter occlusion. The first two with Gianturco coils and the other two with an Amplatzer PDA device. Transcatheter closure of coronary fistulas can be accomplished in most cases. (J Interven Cardiol 2003;16:165–169)
- 28 April 2003
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 16 (2) , 165-169
Open AccessExtension of Transcatheter Coil Occlusion to the Treatment of Complex Coronary Fistulas
Coronary fistulas can be a source of myocardial Ischemia when they are large. In this case series, we describe four complex coronary fistulas treated by transcatheter occlusion. The first two with Gianturco coils and the other two with an Amplatzer PDA device. Transcatheter closure of coronary fistulas can be accomplished in most cases. (J Interven Cardiol 2003;16:165–169)
- 30 September 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 246-251
A new Amplatzer device to maintain patency of Fontan fenestrations and atrial septal defects
This study evaluated use of Amplatzer fenestrated device to maintain patency of the Fontan fenestration and atrial septal defect. Fenestrations are routinely created in patients with lateral tunnel or extracardiac Fontan. Spontaneous closure of the fenestration can lead to Fontan circulation failure. Other patients without single-ventricle physiology may benefit from a small communication between the left and right atria for decompression if closure of the atrial septal defect leads to failure of a dysfunctional ventricle. Amplatzer septal occluder device was modified to create a fenestration through the disks. Three patients with modified Fontan and one patient with a large atrial septal defect underwent placement of the device by transcatheter technique. The device deployment was guided by transesophageal echocardiography. The procedure was successful in all patients. Contrast injection after placement revealed patent fenestration with free flow. Follow-up ranged from 3 months to 1 year. All devices were patent by transthoracic echocardiography. These preliminary results suggest that the Amplatzer fenestrated device can serve as a valuable tool in failing Fontan circulation and may help to avoid surgical intervention. More studies are needed to assess long-term efficacy of the device.
- 30 September 2002
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 57 (2) , 246-251
A new Amplatzer device to maintain patency of Fontan fenestrations and atrial septal defects
This study evaluated use of Amplatzer fenestrated device to maintain patency of the Fontan fenestration and atrial septal defect. Fenestrations are routinely created in patients with lateral tunnel or extracardiac Fontan. Spontaneous closure of the fenestration can lead to Fontan circulation failure. Other patients without single-ventricle physiology may benefit from a small communication between the left and right atria for decompression if closure of the atrial septal defect leads to failure of a dysfunctional ventricle. Amplatzer septal occluder device was modified to create a fenestration through the disks. Three patients with modified Fontan and one patient with a large atrial septal defect underwent placement of the device by transcatheter technique. The device deployment was guided by transesophageal echocardiography. The procedure was successful in all patients. Contrast injection after placement revealed patent fenestration with free flow. Follow-up ranged from 3 months to 1 year. All devices were patent by transthoracic echocardiography. These preliminary results suggest that the Amplatzer fenestrated device can serve as a valuable tool in failing Fontan circulation and may help to avoid surgical intervention. More studies are needed to assess long-term efficacy of the device.
- 1 November 2001
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 122 (5) , 856-862
Hemidiaphragmatic paralysis increases postoperative morbidity after a modified Fontan operation
- 1 November 2001
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 122 (5) , 856-862
Hemidiaphragmatic paralysis increases postoperative morbidity after a modified Fontan operation
- 1 December 2000
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 120 (6) , 1047-1052
Coronary arterial size late after the atrial inversion procedure for transposition of the great arteries: Implications for the arterial switch operation
- 1 December 2000
- Published by Elsevier in The Journal of Thoracic and Cardiovascular Surgery
- Vol. 120 (6) , 1047-1052
Coronary arterial size late after the atrial inversion procedure for transposition of the great arteries: Implications for the arterial switch operation
- 1 August 2000
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 50 (4) , 502-509
Transcatheter closure of membranous ventricular septal defects with a new Nitinol prosthesis in a natural swine model
- 1 August 2000
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 50 (4) , 502-509
Transcatheter closure of membranous ventricular septal defects with a new Nitinol prosthesis in a natural swine model