D. D. L. Chung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
D. D. L. Chung has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Shoukai Wang
Composite Materials Research Laboratory, University at Buffalo, State University of New York, Buffalo, USA
6 shared publicationsChia-Ken Leong
Composite Materials Research Laboratory, University at Buffalo, State University of New York, Buffalo, USA
1 shared publicationChuangang Lin
University at Buffalo, State University of New York
1 shared publicationDaniel P. Kowalik
Composite Materials Research Laboratory, University at Buffalo The State University of New York, Buffalo, NY 14260-4400, U.S.A.
1 shared publicationDaojun Wang
Composite Materials Research Laboratory, University at Buffalo, State University of New York, Buffalo, USA
1 shared publicationJaycee H. Chung
Global Contour Ltd., Rockwall
1 shared publication
Latest Publications
- 1 November 2007
- Published by Springer Nature in Journal of Materials Science
- Vol. 42 (22) , 9245-9255
Nanostructured fumed metal oxides for thermal interface pastes
- 1 November 2007
- Published by Springer Nature in Journal of Materials Science
- Vol. 42 (22) , 9245-9255
Nanostructured fumed metal oxides for thermal interface pastes
- 1 June 2006
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 15 (3) , 295-298
Mats and Fabrics for Electromagnetic Interference Shielding
- 1 June 2006
- Published by Springer Nature in Journal of Materials Engineering and Performance
- Vol. 15 (3) , 295-298
Mats and Fabrics for Electromagnetic Interference Shielding
- 1 April 2006
- Published by Springer Nature in Journal of Materials Science
- Vol. 41 (8) , 2281-2289
Method of sensing impact damage in carbon fiber polymer-matrix composite by electrical resistance measurement
- 1 April 2006
- Published by Springer Nature in Journal of Materials Science
- Vol. 41 (8) , 2281-2289
Method of sensing impact damage in carbon fiber polymer-matrix composite by electrical resistance measurement
- 17 March 2006
- Published by Springer Nature in Journal of Materials Science
- Vol. 41 (10) , 2877-2884
Effect of through-thickness compression on the microstructure of carbon fiber polymer-matrix composites, as studied by electrical resistance measurement
- 17 March 2006
- Published by Springer Nature in Journal of Materials Science
- Vol. 41 (10) , 2877-2884
Effect of through-thickness compression on the microstructure of carbon fiber polymer-matrix composites, as studied by electrical resistance measurement
- 1 October 2004
- Published by Emerald Publishing in Advances in Cement Research
- Vol. 16 (4) , 161-166
Resistance heating using electrically conductive cements
Steel fibre (8 μm diameter, 0·72 vol.%)-reinforced cement was found to be effective for resistance heating. A DC electrical power input of 5·6 W (7·1 V, 0·79 A) resulted in a maximum temperature of 60°C (initial temperature = 19°C) and a time of 6 min to reach half the maximum temperature. Efficiency of energy conversion increased with time of heating, reaching 100% after 50 min. The heat power output per unit area was 750 W/m2 for steel fibre cement, compared with 340 W/m2 for a metal wire with the same resistance. The use of carbon fibres or graphite particles in place of steel fibres resulted in less effective heating, due to the higher resistivity.
- 1 October 2004
- Published by Emerald Publishing in Advances in Cement Research
- Vol. 16 (4) , 161-166
Resistance heating using electrically conductive cements
Steel fibre (8 μm diameter, 0·72 vol.%)-reinforced cement was found to be effective for resistance heating. A DC electrical power input of 5·6 W (7·1 V, 0·79 A) resulted in a maximum temperature of 60°C (initial temperature = 19°C) and a time of 6 min to reach half the maximum temperature. Efficiency of energy conversion increased with time of heating, reaching 100% after 50 min. The heat power output per unit area was 750 W/m2 for steel fibre cement, compared with 340 W/m2 for a metal wire with the same resistance. The use of carbon fibres or graphite particles in place of steel fibres resulted in less effective heating, due to the higher resistivity.
- 1 July 2003
- Published by Springer Nature in Journal of Electroceramics
- Vol. 10 (3) , 147-152
Piezoresistivity in Silicon Carbide Fibers
- 1 July 2003
- Published by Springer Nature in Journal of Electroceramics
- Vol. 10 (3) , 147-152
Piezoresistivity in Silicon Carbide Fibers
- Open Access
- 1 January 2003
- Published by Japan Society of Mechanical Engineers in The Abstracts of ATEM : International Conference on Advanced Technology in Experimental Mechanics : Asian Conference on Experimental Mechanics
- Vol. 2003.2, _OS09W0052
OS09W0052 Monitoring of damage and strain in carbon fiber polymer-matrix structural composites by electrical resistance methods
Polymer-matrix composites containing continuous carbon fibers are the dominant lightweight structural materials. The monitoring of the damage is important for structural health monitoring and hazard mitigation. The monitoring of the strain is relevant to structural vibration control and security. This paper reviews the use of the composites themselves to sense their own damage and strain, thereby removing or reducing the need for embedded or attached sensors, which suffer from high cost and poor durability. Both damage and strain affect the volume electrical resistivity of a composite, thereby allowing the monitoring of damage and strain in real time by volume resistivity measurement. The contact resistivity of the interlaminar interface (i.e., the interface between the laminae) provides another attribute for monitoring. A configuration involving two crossply laminae provides a two-dimensional array of sensors and an x-y grid of electrical interconnections, thereby allowing spatial distribution sensing.
- 1 January 2003
- Published by Japan Society of Mechanical Engineers in The Abstracts of ATEM : International Conference on Advanced Technology in Experimental Mechanics : Asian Conference on Experimental Mechanics
- Vol. 2003.2, _OS09W0052
Open AccessOS09W0052 Monitoring of damage and strain in carbon fiber polymer-matrix structural composites by electrical resistance methods
Polymer-matrix composites containing continuous carbon fibers are the dominant lightweight structural materials. The monitoring of the damage is important for structural health monitoring and hazard mitigation. The monitoring of the strain is relevant to structural vibration control and security. This paper reviews the use of the composites themselves to sense their own damage and strain, thereby removing or reducing the need for embedded or attached sensors, which suffer from high cost and poor durability. Both damage and strain affect the volume electrical resistivity of a composite, thereby allowing the monitoring of damage and strain in real time by volume resistivity measurement. The contact resistivity of the interlaminar interface (i.e., the interface between the laminae) provides another attribute for monitoring. A configuration involving two crossply laminae provides a two-dimensional array of sensors and an x-y grid of electrical interconnections, thereby allowing spatial distribution sensing.
- 1 January 2001
- Published by Taylor & Francis in Composite Interfaces
- Vol. 8 (6) , 435-441
Load transfer from fiber to polymer matrix, studied by measuring the apparent elastic modulus of carbon fiber embedded in epoxy
Load transfer from a single carbon fiber to the surrounding epoxy matrix was studied by measuring the apparent tensile modulus of the fiber while the fiber was embedded in epoxy and comparing the apparent modulus (1650 GPa) with the real modulus (230 GPa). Thus, it was found that 87% of the tensile load applied to the fiber was transferred to the epoxy.
- 1 January 2001
- Published by Taylor & Francis in Composite Interfaces
- Vol. 8 (6) , 435-441
Load transfer from fiber to polymer matrix, studied by measuring the apparent elastic modulus of carbon fiber embedded in epoxy
Load transfer from a single carbon fiber to the surrounding epoxy matrix was studied by measuring the apparent tensile modulus of the fiber while the fiber was embedded in epoxy and comparing the apparent modulus (1650 GPa) with the real modulus (230 GPa). Thus, it was found that 87% of the tensile load applied to the fiber was transferred to the epoxy.
- 1 April 1997
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 6 (2) , 199-203
Self-monitoring of strain in silicon carbide whisker reinforced silicon nitride
- 1 April 1997
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 6 (2) , 199-203
Self-monitoring of strain in silicon carbide whisker reinforced silicon nitride