Richard A. Myers
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Richard A. Myers has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Arieh M. Karger
Radiation Monitoring Devices, Inc
2 shared publications- David W. Hahn
University of Florida
1 shared publication - Eric Mazur
Harvard University
1 shared publication James E. Carey
Department of Physics and Division of Engineering and Applied Science
1 shared publicationMichael R. Squillante
Radiation Monitoring Devices, Inc
1 shared publicationNoah J. Kolodziejski
Radiation Monitoring Devices, Inc
1 shared publication
Latest Publications
- 17 July 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (31) , G7-G14
Commercialization of laser-induced breakdown spectroscopy for lead-in-paint inspection
A study was undertaken to determine if laser-induced breakdown spectroscopy (LIBS) can be a practical and competitive alternative to x-ray fluorescence (XRF) methods for lead-in-paint inspection. Experiments in the laboratory confirmed that LIBS is suitable for detecting lead in paint at the hazard levels defined by federal agencies. Although we compared speed, function, and cost, fundamental differences between the XRF and LIBS measurements limited our ability to make a quantitative performance comparison. While the LIBS method can achieve the required sensitivity and offers a way to obtain unique information during inspection, the current component costs will likely restrict interest in the method to niche applications.
- 17 July 2008
- Published by Optica Publishing Group in Applied Optics
- Vol. 47 (31) , G7-G14
Commercialization of laser-induced breakdown spectroscopy for lead-in-paint inspection
A study was undertaken to determine if laser-induced breakdown spectroscopy (LIBS) can be a practical and competitive alternative to x-ray fluorescence (XRF) methods for lead-in-paint inspection. Experiments in the laboratory confirmed that LIBS is suitable for detecting lead in paint at the hazard levels defined by federal agencies. Although we compared speed, function, and cost, fundamental differences between the XRF and LIBS measurements limited our ability to make a quantitative performance comparison. While the LIBS method can achieve the required sensitivity and offers a way to obtain unique information during inspection, the current component costs will likely restrict interest in the method to niche applications.
- 10 December 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (35) , 8825-8831
Enhancing near-infrared avalanche photodiode performance by femtosecond laser microstructuring
A processing technique using femtosecond laser pulses to microstructure the surface of a silicon avalanche photodiode (APD) has been used to enhance its near-infrared (near-IR) response. Experiments were performed on a series of APDs and APD arrays using various structuring parameters and poststructuring annealing sequences. Following thermal annealing, we were able to fabricate APD arrays with quantum efficiencies as high as at 1064 nm without degradation of their noise or gain performance. Experimental results provided evidence to suggest that the improvement in charge collection is a result of increased absorption in the near-IR.- 10 December 2006
- Published by Optica Publishing Group in Applied Optics
- Vol. 45 (35) , 8825-8831
Enhancing near-infrared avalanche photodiode performance by femtosecond laser microstructuring
A processing technique using femtosecond laser pulses to microstructure the surface of a silicon avalanche photodiode (APD) has been used to enhance its near-infrared (near-IR) response. Experiments were performed on a series of APDs and APD arrays using various structuring parameters and poststructuring annealing sequences. Following thermal annealing, we were able to fabricate APD arrays with quantum efficiencies as high as at 1064 nm without degradation of their noise or gain performance. Experimental results provided evidence to suggest that the improvement in charge collection is a result of increased absorption in the near-IR.- 20 October 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (30) , 6072-6077
Geiger photodiode array for compact, lightweight laser-induced breakdown spectroscopy instrumentation
The development of a unique spectrometer based on an array of Geiger photodiodes has been shown to enhance the performance of laser-induced breakdown spectroscopy (LIBS) instrumentation. These compact, silicon-based detectors eliminate the need for postamplification electronics, allow for the detection of single photons at room temperature, and do not require complex gating-timing circuitry. The detectors have dark-count rates of <500 Hz at room temperature and a good response from the UV to the near IR. Their high sensitivity makes them candidates for standoff analysis as part of a LIBS spectrum analyzer.
- 20 October 2003
- Published by Optica Publishing Group in Applied Optics
- Vol. 42 (30) , 6072-6077
Geiger photodiode array for compact, lightweight laser-induced breakdown spectroscopy instrumentation
The development of a unique spectrometer based on an array of Geiger photodiodes has been shown to enhance the performance of laser-induced breakdown spectroscopy (LIBS) instrumentation. These compact, silicon-based detectors eliminate the need for postamplification electronics, allow for the detection of single photons at room temperature, and do not require complex gating-timing circuitry. The detectors have dark-count rates of <500 Hz at room temperature and a good response from the UV to the near IR. Their high sensitivity makes them candidates for standoff analysis as part of a LIBS spectrum analyzer.