HLHo Lee

Ho Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ho Lee has a total of 10 co-authors. Here are the top co-authors by number of shared publications:

  • A. J. Welch

    Dept. of Biomedical Engineering, The University of Texas at Austin, Texas Longhorns, Austin, TX 78712, Phone: (512) 471-9497, Fax: (512) 232-4919

    1 shared publication
  • Ashley J. Welch

    Department of Biomedical Engineering, The University of Texas at Austin, 1 University Station, #C0800, Austin, Texas

    1 shared publication
  • Bernard Choi

    University of California – Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, United States

    1 shared publication
  • Hyun Wook Kang

    Department of Biomedical Engineering, The University of Texas at Austin, 1 University Station, #C0800, Austin, Texas

    1 shared publication
  • Jeehyun Kim

    Dept. of Biomedical Engineering, The University of Texas at Austin, Texas Longhorns, Austin, TX 78712, Phone: (512) 471-9497, Fax: (512) 232-4919

    1 shared publication
  • Joel M. H. Teichman

    Divisions of Urology, University of Texas Health Science Center, 7703 Floyd Curl Drive, San Antonio, TX 78229, Phone: (210) 567-5640, Fax: (210) 567-6868

    1 shared publication

Latest Publications

  • Urinary calculus fragmentation during Ho: YAG and Er:YAG lithotripsy

    by Ho Lee, Hyun Wook Kang, Joel M.H. Teichman, Junghwan Oh, Ashley J. Welch

    Background and Objectives We tested Ho:YAG and Er:YAG laser ablation of human urinary calculi to determine if Er:YAG is a more efficient lithotripsy device. Study Design/Materials and Methods Ablation efficiency of Ho:YAG and Er:YAG lasers was tested at varying energy settings, ranging from the damage threshold to clinical energy setting associated with Ho:YAG laser. Stones of known composition (calcium oxalate monohydrate (COM), cystine, and uric acid (UA)) were irradiated. Crater width, depth, and ablation volumes were determined using an optical coherence tomography (OCT). Results For all stones and energy settings, the Er:YAG laser produced deeper craters and larger ablation volumes than Ho:YAG laser. The Ho:YAG laser created wider craters during the multiple pulse process and the shape of craters was irregular. Conclusions The Er:YAG laser is more efficient than the Ho:YAG laser for lithotripsy. The deeper craters produced by the Er:YAG laser is attributed to the high absorption of energy at its wavelength. Lasers Surg. Med.


  • Dependence of Calculus Retropulsion Dynamics on Fiber Size and Radiant Exposure During Ho:YAG Lithotripsy

    by Ho Lee, Robert T. Ryan, Jeehyun Kim, Bernard Choi, Navanit V. Arakeri, Joel M. H. Teichman, A. J. Welch

    During pulsed laser lithotripsy, the calculus is subject to a strong recoil momentum which moves the calculus away from laser delivery and prolongs the operation. This study was designed to quantify the recoil momentum during Ho:YAG laser lithotripsy. The correlation among crater shape, debris trajectory, laser-induced bubble and recoil momentum was investigated. Calculus phantoms made from plaster of Paris were ablated with free running Ho:YAG lasers. The dynamics of recoil action of a calculus phantom was monitored by a high-speed video camera and the laser ablation craters were examined with Optical Coherent Tomography (OCT). Higher radiant exposure resulted in larger ablation volume (mass) which increased the recoil momentum. Smaller fibers produced narrow craters with a steep contoured geometry and decreased recoil momentum compared to larger fibers. In the presence of water, recoil motion of the phantom deviated from that of phantom in air. Under certain conditions, we observed the phantom rocking towards the fiber after the laser pulse. The shape of the crater is one of the major contributing factors to the diminished recoil momentum of smaller fibers. The re-entrance flow of water induced by the bubble collapse is considered to be the cause of the rocking of the phantom.