APAteş Parlar

Ateş Parlar

*This is an algorithmically generated author record based on publicly available information.

Ateş Parlar has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of stresses in monoblock tilted implants and conventional angled multiunit abutment-implant connection systems in the all-on-four procedure

    by Özge Özdal Zincir, Ateş Parlar

    Background: The All-on-four dental implant method is an implantology method designed to provide a comfortable prosthetic treatment option by avoiding advanced surgical procedures. This research aims to compare and evaluate the stress and tension values in conventional angled multiunit abutment-implant connection systems and monoblock dental implants used in the all-on-four procedure with finite element analysis.Methods: Two master models were created by placing four implants connected to multiunit abutments (group A) in the interforaminal region of a completely edentulous mandible and four monoblock implants (group B) in the same region of another completely edentulous mandible. Group A implants were classified according to their diameter as follows: 3.5 mm (M1A), 4.0 mm (M2A), and 4.5 mm (M3A). Similarly, group B implants were classified as M1B, M2B, and M3B. In the six models rehabilitated with acrylic fixed prostheses, a 100 N force was applied to the anterior implant region, and a 250 N force was applied to the posterior cantilever in both axial and 30° oblique directions. Von Mises stresses were analyzed in the bone and implant regions of all models.Results: M1A and M1B, M2A and M2B, and M3A and M3B were compared with each other under axial and oblique forces. The maximum Von Mises stresses in the bone around implants and the prosthesis screws, and the maximum and minimum principal stresses in the cortical and trabecular bone in group A models were significantly higher than those in group B models.Conclusions: In monoblock implant systems under axial and oblique forces, higher stress is accumulated in the bone, prosthesis screw and implant compared to multiunit abutment-implant connection systems.


  • Effects of decontamination and implant surface characteristics on re‐osseointegration following treatment of peri‐implantitis

    by Ateş Parlar, Dieter D. Bosshardt, Deniz Çetiner, Denis Schafroth, Berrin Ünsal, Cenk Haytaç, Niklaus P. Lang

    Although considerable bone fill may occur following treatment of peri-implantitis, re-osseointegration appears to be limited and unpredictable. To evaluate the effects of various decontamination techniques and implant surface configurations on re-osseointegration of contaminated dental implants. Three months after tooth extraction, implants consisting of a basal part and an exchangeable intraosseous implant cylinder (EIIC) were placed in the mandibles of dogs. The EIIC was machined (M), sandblasted and acid-etched (SLA), or titanium plasma sprayed (TPS). Ligature-induced peri-implantitis was initiated 8 weeks post-implantation and lasted until bone loss reached the junction of the two implant parts. Three treatment modalities were applied: (T1) the EIIC was exchanged for a pristine EIIC; (T2) the EIIC was sprayed in situ with saline; and (T3) the EIIC was removed, cleansed outside the mouth by spraying with saline, steam-sterilized, and remounted. A collagen barrier was placed over each fixture, and 3 months later, samples were processed for histology and histomorphometry. T2 revealed the highest bone-to-implant contact (BIC) level (significantly better than T1 and T3). T2 also yielded the highest bone crest level (significantly better than T1), followed by T3 (significantly better than T1). SLA showed the highest BIC level (significantly better than M), followed by TPS. There were no statistically significant differences in bone crest height between implant types. Both SLA implants and in situ cleansing resulted in the best re-osseointegration and bone fill of previously contaminated implants.


    • 1 February 2004
      • Vol. 117  (2) , 270-4

    Evaluation of periodontal healing in class II furcation defects following guided tissue regeneration with two different types of polylactic acid membranes.

    by Deniz Cetiner, Berrin Unsal, Ateş Parlar, Elif Gültekin, Bülent Kurtiş

    Guided tissue regeneration procedures provide predictable reconstruction of periodontal tissues in the treatment of furcation involvements in animals and humans. This study was to compare long-term effectiveness of two different types of polylactic acid (PLA) membranes on periodontal regeneration in surgically created class II furcation defects in dogs. Full thickness mucoperiosteal flap was raised on the buccal aspects of the experimental teeth and class II furcation defects having 5 mm vertical dimensions were created on mandibular premolar III and IV on each quadrant. The exposed root surfaces were thoroughly planed and PLA membranes were placed over the experimental defects on both sites. One site received liquid polymer membrane (LPM), and resorbable periodontal mesh (RPM) membranes were applied to the other site. The animals were sacrificed at 7 months after surgery and the specimens were processed for histological evaluation. The average length of new attachment formed on the treated roots in both groups ranged from 3.02 mm to 4.5 mm. Complete bone filling was observed at the furcation sites. No statistically significant differences were found between two membranes in any of the parameters (P > 0.05). This study demonstrates favorable regenerative outcomes by the use of two different types of PLA membranes that could be used as alternatives for guided tissue regeneration (GTR).