Ulf Nyman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ulf Nyman has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Jonas Björk
Division of Occupational and Environmental Medicine, Lund University, Lund, Sweden
9 shared publications - Anders Grubb
Department of Clinical Chemistry Skåne University Hospital Lund University Lund Sweden
6 shared publications Gunnar Sterner
Department of Nephrology and Transplantation, University Hospital, Malmö
6 shared publications- Mikael Hellström
Department of Radiology, Institute of Clinical Sciences Sahlgrenska Academy, University of Gothenburg Gothenburg Sweden
6 shared publications Torsten Almén
University of Lund, Skåne University Hospital
5 shared publicationsBarbara Elmståhl
Skåne University Hospital
4 shared publications
Latest Publications
- 19 May 2017
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 77 (5) , 338-344
Estimating glomerular filtration rate (GFR) in children. The average between a cystatin C- and a creatinine-based equation improves estimation of GFR in both children and adults and enables diagnosing Shrunken Pore Syndrome
Estimating glomerular filtration rate (GFR) in adults by using the average of values obtained by a cystatin C- (eGFR) and a creatinine-based (eGFR) equation shows at least the same diagnostic performance as GFR estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparison of eGFR and eGFR plays a pivotal role in the diagnosis of Shrunken Pore Syndrome, where low eGFR compared to eGFR has been associated with higher mortality in adults. The present study was undertaken to elucidate if this concept can also be applied in children. Using iohexol and inulin clearance as gold standard in 702 children, we studied the diagnostic performance of 10 creatinine-based, 5 cystatin C-based and 3 combined cystatin C-creatinine eGFR equations and compared them to the result of the average of 9 pairs of a eGFR and a eGFR estimate. While creatinine-based GFR estimations are unsuitable in children unless calibrated in a pediatric or mixed pediatric-adult population, cystatin C-based estimations in general performed well in children. The average of a suitable creatinine-based and a cystatin C-based equation generally displayed a better diagnostic performance than estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparing eGFR and eGFR may help identify pediatric patients with Shrunken Pore Syndrome.
- 19 May 2017
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 77 (5) , 338-344
Estimating glomerular filtration rate (GFR) in children. The average between a cystatin C- and a creatinine-based equation improves estimation of GFR in both children and adults and enables diagnosing Shrunken Pore Syndrome
Estimating glomerular filtration rate (GFR) in adults by using the average of values obtained by a cystatin C- (eGFR) and a creatinine-based (eGFR) equation shows at least the same diagnostic performance as GFR estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparison of eGFR and eGFR plays a pivotal role in the diagnosis of Shrunken Pore Syndrome, where low eGFR compared to eGFR has been associated with higher mortality in adults. The present study was undertaken to elucidate if this concept can also be applied in children. Using iohexol and inulin clearance as gold standard in 702 children, we studied the diagnostic performance of 10 creatinine-based, 5 cystatin C-based and 3 combined cystatin C-creatinine eGFR equations and compared them to the result of the average of 9 pairs of a eGFR and a eGFR estimate. While creatinine-based GFR estimations are unsuitable in children unless calibrated in a pediatric or mixed pediatric-adult population, cystatin C-based estimations in general performed well in children. The average of a suitable creatinine-based and a cystatin C-based equation generally displayed a better diagnostic performance than estimates obtained by equations using only one of these analytes or by complex equations using both analytes. Comparing eGFR and eGFR may help identify pediatric patients with Shrunken Pore Syndrome.
- 2 December 2014
- Vol. 111, 2236-7
[Ultrasound vs. CT in ureteral stones--Swedish procedures apply].
- 20 April 2013
- Vol. 110 (11) , 562-5
[Diagnostic studies should follow international guidelines. Planning and evaluation requires theoretical and practical considerations].
- 20 April 2013
- Vol. 110 (11) , 562-5
[Diagnostic studies should follow international guidelines. Planning and evaluation requires theoretical and practical considerations].
- 1 February 2013
- Published by Springer Nature in European Radiology
- Vol. 23 (5) , 1264-1265
Reply to letter to the editor re: Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?
- 1 February 2013
- Published by Springer Nature in European Radiology
- Vol. 23 (5) , 1264-1265
Reply to letter to the editor re: Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?
- 25 December 2012
- Vol. 109 (46) , 2068
[Is everyone involved in radiology rounds criminals?].
- 1 November 2012
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (9) , 1004-1013
Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study
Background: Mounting collective radiation doses from computed tomography (CT) implies an increased risk of radiation-induced cancer in exposed populations, especially in the young. Purpose: To evaluate radiation dose and image quality at 80-kVp CT to diagnose acute pulmonary embolism (PE) compared with a previous study at 100 and 120 kVp with all other scanning parameters unchanged. Material and Methods: A custom-made chest phantom with a 12 mg I/mL-syringe was scanned at 80/100/ 120 kVp to evaluate relative changes in computed tomographic dose index (CTDIvol), attenuation, image noise, and contrast-to-noise ratio (CNR). Fifty patients underwent 80 kVp 16-row detector CT at 100 ‘Quality reference’ mAs. A total of 350 mg I/kg were injected to compensate for increased CNR at 80 kVp, while 300 mg I/kg had been used at 100/120 kVp. CTDIvol, dose-length product (DLP), and estimated effective dose were evaluated including Monte Carlo simulations. Pulmonary artery attenuation and noise were measured and CNR calculated. Two radiologists evaluated subjective image quality using a four-grade scale. Results: Switching from 120 to 80 kVp in the phantom study decreased radiation dose by 67% while attenuation and noise increased 1.6 and 2.0 times, respectively, and CNR decreased by 16%. Switching from 120 to 80 kVp in the patient studies decreased estimated effective dose from 4.0 to 1.2 mSv (70% decrease) in median while pulmonary artery attenuation and noise roughly doubled from 332 to 653 HU and from 22 to 49 HU, respectively, resulting in similar CNR (13 vs. 12). At 80 kVp all examinations were regarded as adequate (8%) or excellent (92%). Conclusion: Switching from 120 to 80 kVp CT without increased mAs but slightly increased iodine dose may be of special benefit to diagnose PE in younger individuals with preserved renal function where the primary aim is to minimize radiation dose and reaching levels below that of scintigraphy.
- 1 November 2012
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (9) , 1004-1013
Low-dose radiation with 80-kVp computed tomography to diagnose pulmonary embolism: a feasibility study
Background: Mounting collective radiation doses from computed tomography (CT) implies an increased risk of radiation-induced cancer in exposed populations, especially in the young. Purpose: To evaluate radiation dose and image quality at 80-kVp CT to diagnose acute pulmonary embolism (PE) compared with a previous study at 100 and 120 kVp with all other scanning parameters unchanged. Material and Methods: A custom-made chest phantom with a 12 mg I/mL-syringe was scanned at 80/100/ 120 kVp to evaluate relative changes in computed tomographic dose index (CTDIvol), attenuation, image noise, and contrast-to-noise ratio (CNR). Fifty patients underwent 80 kVp 16-row detector CT at 100 ‘Quality reference’ mAs. A total of 350 mg I/kg were injected to compensate for increased CNR at 80 kVp, while 300 mg I/kg had been used at 100/120 kVp. CTDIvol, dose-length product (DLP), and estimated effective dose were evaluated including Monte Carlo simulations. Pulmonary artery attenuation and noise were measured and CNR calculated. Two radiologists evaluated subjective image quality using a four-grade scale. Results: Switching from 120 to 80 kVp in the phantom study decreased radiation dose by 67% while attenuation and noise increased 1.6 and 2.0 times, respectively, and CNR decreased by 16%. Switching from 120 to 80 kVp in the patient studies decreased estimated effective dose from 4.0 to 1.2 mSv (70% decrease) in median while pulmonary artery attenuation and noise roughly doubled from 332 to 653 HU and from 22 to 49 HU, respectively, resulting in similar CNR (13 vs. 12). At 80 kVp all examinations were regarded as adequate (8%) or excellent (92%). Conclusion: Switching from 120 to 80 kVp CT without increased mAs but slightly increased iodine dose may be of special benefit to diagnose PE in younger individuals with preserved renal function where the primary aim is to minimize radiation dose and reaching levels below that of scintigraphy.
- 4 February 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (6) , 1366-1371
Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?
We oppose the opinion that the intra-arterial administration of iodine-based contrast media (CM) appears to pose a greater risk of contrast medium-induced nephropathy (CIN) than intravenous administration since 1) in intra-arterial coronary procedures and most other intra-arterial angiographic examinations, CM injections are also intravenous relative to the kidneys, 2) there is a lack of comparative trials studying the risk of CIN between intra-arterial and intravenous procedures with matched risk factors and CM doses, 3) a bias selection of patients with fewer risk factors may explain the seemingly lower rate of CIN after CT in comparison with coronary interventions, 4) the rate of CIN following intra-arterial coronary procedures may also be exaggerated owing to other causes of acute kidney failure, such as haemodynamic instability and microembolisation, 5) roughly the same gram-iodine/GFR ratio (≈1:1) as a limit of relatively safe CM doses has preliminarily been found for both intravenous CT and intra-arterial coronary procedures and 6) the substantially higher injected intravenous CM dose rate during CT relative to an intra-arterial coronary procedure might actually pose a higher risk of CIN following CT. Key Points • Most intra-arterial injections of contrast media are intravenous relative to the kidneys. • No evidence that intravenous CM injections should be less nephrotoxic than intra-arterial. • Considerably higher dose rates of CM are used for CT relative to intra-arterial procedures. • Higher dose rates may pose higher nephrotoxic risk for intravenous based CT studies.
- 4 February 2012
- Published by Springer Nature in European Radiology
- Vol. 22 (6) , 1366-1371
Are intravenous injections of contrast media really less nephrotoxic than intra-arterial injections?
We oppose the opinion that the intra-arterial administration of iodine-based contrast media (CM) appears to pose a greater risk of contrast medium-induced nephropathy (CIN) than intravenous administration since 1) in intra-arterial coronary procedures and most other intra-arterial angiographic examinations, CM injections are also intravenous relative to the kidneys, 2) there is a lack of comparative trials studying the risk of CIN between intra-arterial and intravenous procedures with matched risk factors and CM doses, 3) a bias selection of patients with fewer risk factors may explain the seemingly lower rate of CIN after CT in comparison with coronary interventions, 4) the rate of CIN following intra-arterial coronary procedures may also be exaggerated owing to other causes of acute kidney failure, such as haemodynamic instability and microembolisation, 5) roughly the same gram-iodine/GFR ratio (≈1:1) as a limit of relatively safe CM doses has preliminarily been found for both intravenous CT and intra-arterial coronary procedures and 6) the substantially higher injected intravenous CM dose rate during CT relative to an intra-arterial coronary procedure might actually pose a higher risk of CIN following CT. Key Points • Most intra-arterial injections of contrast media are intravenous relative to the kidneys. • No evidence that intravenous CM injections should be less nephrotoxic than intra-arterial. • Considerably higher dose rates of CM are used for CT relative to intra-arterial procedures. • Higher dose rates may pose higher nephrotoxic risk for intravenous based CT studies.
- 3 September 2011
- Published by Springer Nature in Gefässchirurgie
- Vol. 16 (7) , 469-480
Minimierung kontrastmittelinduzierter Nephropathien
- 3 September 2011
- Published by Springer Nature in Gefässchirurgie
- Vol. 16 (7) , 469-480
Minimierung kontrastmittelinduzierter Nephropathien
- 5 January 2011
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 71 (2) , 129-138
The CKD-EPI and MDRD equations to estimate GFR. Validation in the Swedish Lund-Malmö Study cohort
Objective. To compare the recently developed CKD-EPI equation to estimate GFR in adult Swedish-Caucasians with the MDRD equation. Material and methods. Swedish-Caucasians (N = 850, 376 females; median age 60, range 5–95 years) referred for plasma iohexol-clearance (median 55, range 5–223 mL/min/1.73 m2) constituted the Lund-Malmö Study cohort. Bias, precision (interquartile range, IQR, of the differences between estimated and measured GFR), accuracy expressed as percentage of estimates ±10% (P10) and ±30% (P30) of measured GFR, and classification ability for five GFR stages 2 were compared. Results. Overall there were no important differences between the equations; CKD-EPI/MDRD median values of bias +5.4%/+3.4%, IQR both 14 mL/min/1.73 m2, P10 36%/34%, P30 both 80%, and correctly classified GFR stages 68%/67%. P30 for the CKD-EPI equation was substantially higher than for MDRD at GFR ≥90 mL/min/1.73 m2 (93% versus 79%). The MDRD equation performed better in the GFR interval 30–89 mL/min/1.73 m2, while accuracy was limited for both equations at GFR 2 (P30 2 (CKD-EPI/MDRD median bias +36%/46%). Conclusion. Overall the recently developed CKD-EPI equation performed well but was not superior to the MDRD equation. The CKD-EPI equation may be preferred in screenings of general populations and in the elderly. None of the equations appeared reliable among patients with markedly decreased GFR, young adults and underweight males.
- 5 January 2011
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 71 (2) , 129-138
The CKD-EPI and MDRD equations to estimate GFR. Validation in the Swedish Lund-Malmö Study cohort
Objective. To compare the recently developed CKD-EPI equation to estimate GFR in adult Swedish-Caucasians with the MDRD equation. Material and methods. Swedish-Caucasians (N = 850, 376 females; median age 60, range 5–95 years) referred for plasma iohexol-clearance (median 55, range 5–223 mL/min/1.73 m2) constituted the Lund-Malmö Study cohort. Bias, precision (interquartile range, IQR, of the differences between estimated and measured GFR), accuracy expressed as percentage of estimates ±10% (P10) and ±30% (P30) of measured GFR, and classification ability for five GFR stages 2 were compared. Results. Overall there were no important differences between the equations; CKD-EPI/MDRD median values of bias +5.4%/+3.4%, IQR both 14 mL/min/1.73 m2, P10 36%/34%, P30 both 80%, and correctly classified GFR stages 68%/67%. P30 for the CKD-EPI equation was substantially higher than for MDRD at GFR ≥90 mL/min/1.73 m2 (93% versus 79%). The MDRD equation performed better in the GFR interval 30–89 mL/min/1.73 m2, while accuracy was limited for both equations at GFR 2 (P30 2 (CKD-EPI/MDRD median bias +36%/46%). Conclusion. Overall the recently developed CKD-EPI equation performed well but was not superior to the MDRD equation. The CKD-EPI equation may be preferred in screenings of general populations and in the elderly. None of the equations appeared reliable among patients with markedly decreased GFR, young adults and underweight males.
- 29 August 2010
- Published by Springer Nature in European Radiology
- Vol. 21 (2) , 326-336
Iodine contrast iso-attenuating with diagnostic gadolinium doses in CTA and angiography results in ultra-low iodine doses. A way to avoid both CIN and NSF in azotemic patients?
- 29 August 2010
- Published by Springer Nature in European Radiology
- Vol. 21 (2) , 326-336
Iodine contrast iso-attenuating with diagnostic gadolinium doses in CTA and angiography results in ultra-low iodine doses. A way to avoid both CIN and NSF in azotemic patients?