Brian J. Manning
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Brian J. Manning has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Krassi Ivancev
5 shared publicationsPeter L. Harris
3 shared publicationsTimothy Resch
Vascular Centre Malmö-Lund, Malmö University Hospital, Malmö, Sweden
3 shared publicationsBjörn Sonesson
Vascular Centre Malmö-Lund, Malmö University Hospital, Malmö, Sweden
2 shared publicationsK. Ivancev
2 shared publicationsMartin Malina
Vascular Centre Malmö-Lund, Malmö University Hospital, Malmö, Sweden
2 shared publications
Latest Publications
- 1 April 2019
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 57 (4) , 561
Lower Extremity Amputation: Analysis by Postcode
- 1 April 2019
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 57 (4) , 561
Lower Extremity Amputation: Analysis by Postcode
- 1 November 2016
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 52 (5) , 612
Commentary on ‘Orthogonal Rings, Fiducial Markers and Overlay Accuracy When Image Fusion is Used for EVAR Guidance’
- 1 November 2016
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 52 (5) , 612
Commentary on ‘Orthogonal Rings, Fiducial Markers and Overlay Accuracy When Image Fusion is Used for EVAR Guidance’
- 1 August 2013
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 20 (4) , 469-470
Commentary: Wired and Raring to Go: The Preloaded Fenestrated Stent-Graft
- 1 August 2013
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 20 (4) , 469-470
Commentary: Wired and Raring to Go: The Preloaded Fenestrated Stent-Graft
- 1 March 2011
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 53 (3) , 867-869
Temporary axillobifemoral bypass as an adjunct to endovascular aneurysm repair using fenestrated stent grafts
- 1 March 2011
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 53 (3) , 867-869
Temporary axillobifemoral bypass as an adjunct to endovascular aneurysm repair using fenestrated stent grafts
- 1 August 2010
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 52 (2) , 491-494
In situ fenestration in the aortic arch
- 1 August 2010
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 52 (2) , 491-494
In situ fenestration in the aortic arch
- 1 August 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (4) , 449-455
Preloaded Fenestrated Stent-Grafts for the Treatment of Juxtarenal Aortic Aneurysms
Purpose: To describe a novel technique for target vessel catheterization in patients with juxtarenal abdominal aortic aneurysms requiring treatment with fenestrated stent-grafts (FSG). Methods: The standard FSG design was modified, substituting a thin-wall tube for the solid central obturator that serves as both an attachment point for the distal end of the graft as well as a top cap retriever. Through this tube, two 0.020-inch wires are run from the hub of the delivery system through the stent-graft, out through each fenestration, and up to the proximal edge of the graft, where they are attached by sutures. The sutures are connected to a trigger wire on the control hub. The preloaded wires facilitate passage of a sheath to the fenestration, providing stability while target vessel catheterization takes place and avoiding the use of a large sheath in the contralateral groin. A third wire attached to the inside of the top cap facilitates its safe retrieval via a 6-mm balloon. The preloaded FSG was used in 5 male patients (mean age 75.6 years) with either juxtarenal aneurysms (n=2) or aneurysms previously treated with infrarenal stent-grafts that had developed type I endoleak (n=3). In 3 cases, a double fenestrated stent-graft was required, and in 2 cases a triple fenestrated device was deployed, with scallops for the superior mesenteric or celiac arteries. Results: Sixteen of 17 target vessels were preserved, and all aneurysms were successfully excluded with no endoleak at completion. In 2 patients, tortuosity encountered during device delivery caused twisting of the wires within the preloaded FSG, preventing successful advancement of a sheath over a preloaded wire. An approach from the contralateral groin was necessary to complete the procedure in 1 case, but the target vessel was lost in the other. Conclusion: The use of a preloaded FSG is feasible and facilitates the catheterization of fenestrations and of target arteries. This method has the potential to reduce procedure times and lower the risk of intraoperative lower limb ischemia.
- 1 August 2010
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 17 (4) , 449-455
Preloaded Fenestrated Stent-Grafts for the Treatment of Juxtarenal Aortic Aneurysms
Purpose: To describe a novel technique for target vessel catheterization in patients with juxtarenal abdominal aortic aneurysms requiring treatment with fenestrated stent-grafts (FSG). Methods: The standard FSG design was modified, substituting a thin-wall tube for the solid central obturator that serves as both an attachment point for the distal end of the graft as well as a top cap retriever. Through this tube, two 0.020-inch wires are run from the hub of the delivery system through the stent-graft, out through each fenestration, and up to the proximal edge of the graft, where they are attached by sutures. The sutures are connected to a trigger wire on the control hub. The preloaded wires facilitate passage of a sheath to the fenestration, providing stability while target vessel catheterization takes place and avoiding the use of a large sheath in the contralateral groin. A third wire attached to the inside of the top cap facilitates its safe retrieval via a 6-mm balloon. The preloaded FSG was used in 5 male patients (mean age 75.6 years) with either juxtarenal aneurysms (n=2) or aneurysms previously treated with infrarenal stent-grafts that had developed type I endoleak (n=3). In 3 cases, a double fenestrated stent-graft was required, and in 2 cases a triple fenestrated device was deployed, with scallops for the superior mesenteric or celiac arteries. Results: Sixteen of 17 target vessels were preserved, and all aneurysms were successfully excluded with no endoleak at completion. In 2 patients, tortuosity encountered during device delivery caused twisting of the wires within the preloaded FSG, preventing successful advancement of a sheath over a preloaded wire. An approach from the contralateral groin was necessary to complete the procedure in 1 case, but the target vessel was lost in the other. Conclusion: The use of a preloaded FSG is feasible and facilitates the catheterization of fenestrations and of target arteries. This method has the potential to reduce procedure times and lower the risk of intraoperative lower limb ischemia.
- 1 April 2010
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 39 (4) , 431-435
Ready-to-Fenestrate Stent Grafts in the Treatment of Juxtarenal Aortic Aneurysms: Proposal for an Off-the-shelf Device
- 1 April 2010
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 39 (4) , 431-435
Ready-to-Fenestrate Stent Grafts in the Treatment of Juxtarenal Aortic Aneurysms: Proposal for an Off-the-shelf Device
- 1 January 2010
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 110 (1) , 112-115
Techniques for Supra-aortic Trunk Preservation in Thoracic Endovascular Aneurysm Repair
Stent graft placement for aneurysmal disease of the aortic arch and proximal descending aorta is limited by the need to preserve flow to the supra-aortic trunks. Whilst extra-anatomical bypass and procedures combining open and endovascular arch repair are currently used in this setting, less invasive totally endovascular solutions have been described. These include in-situ fenestration of a thoracic stent graft using a retrograde approach from the target vessel to the lumen of the main device, to which it is connected by a smaller covered stent. Alternatively, so-called ‘chimney’ stents have been used, placing a parallel stent alongside the main device, connecting the aortic branch vessel with the native aortic lumen proximal to the seal zone of the main thoracic device. We review these techniques and discuss the merits and potential disadvantages of each procedure.
- 1 January 2010
- Published by Taylor & Francis in Acta Chirurgica Belgica
- Vol. 110 (1) , 112-115
Techniques for Supra-aortic Trunk Preservation in Thoracic Endovascular Aneurysm Repair
Stent graft placement for aneurysmal disease of the aortic arch and proximal descending aorta is limited by the need to preserve flow to the supra-aortic trunks. Whilst extra-anatomical bypass and procedures combining open and endovascular arch repair are currently used in this setting, less invasive totally endovascular solutions have been described. These include in-situ fenestration of a thoracic stent graft using a retrograde approach from the target vessel to the lumen of the main device, to which it is connected by a smaller covered stent. Alternatively, so-called ‘chimney’ stents have been used, placing a parallel stent alongside the main device, connecting the aortic branch vessel with the native aortic lumen proximal to the seal zone of the main thoracic device. We review these techniques and discuss the merits and potential disadvantages of each procedure.
- 1 October 2009
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 16 (5) , 590-597
Endovascular Treatment for Chronic Type B Dissection:Limitations of Short Stent-Grafts Revealed at Midterm Follow-up
Purpose: To examine the incidence of and the indications for re-intervention, as well as the changes in aortic morphology, in patients with chronic type B aortic dissection who underwent endovascular intervention for false lumen aneurysms. Methods: A retrospective analysis was conducted of 10 patients (8 men; mean age 63 years, range 45–79) who underwent stent-graft repair of aneurysmal false lumen expansion related to chronic type B aortic dissection at a median 16 months (range 2–71) from the initial diagnosis. All grafts had been oversized by 10% relative to the normal non-dissected aorta and were implanted to cover the primary entry tear. Follow-up computed tomography scans were analyzed to define changes in aortic morphology. results: Mean radiological follow-up was 56 months (median 64.5; range 19–86.5). There was no perioperative mortality or stroke; no cases of aortic rupture were recorded during follow-up. One patient suffered a procedure-related stroke with postoperative hemiparesis following re-intervention for proximal erosion 15 months after the initial treatment. In 6 of the 7 re-interventions performed in 6 patients at a median 42 months after the index procedure, stent-graft extension was required to treat erosion of the dissection membrane that had resulted in endoleak with false lumen reperfusion. The extent of dissection, duration of follow-up, or length of aortic coverage was not predictive of the need for re-intervention during follow-up. At last follow-up, the mean false lumen diameter at the level of the stented aorta was significantly smaller than at baseline (11±15 versus 24±15 mm, pConclusion: Endovascular stent-graft treatment is effective therapy for chronic type B dissection patients with false lumen aneurysms. Erosion of the dissection membrane, causing proximal or distal endoleak, is the most common reason for re-intervention during midterm follow-up.
- 1 October 2009
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 16 (5) , 590-597
Endovascular Treatment for Chronic Type B Dissection:Limitations of Short Stent-Grafts Revealed at Midterm Follow-up
Purpose: To examine the incidence of and the indications for re-intervention, as well as the changes in aortic morphology, in patients with chronic type B aortic dissection who underwent endovascular intervention for false lumen aneurysms. Methods: A retrospective analysis was conducted of 10 patients (8 men; mean age 63 years, range 45–79) who underwent stent-graft repair of aneurysmal false lumen expansion related to chronic type B aortic dissection at a median 16 months (range 2–71) from the initial diagnosis. All grafts had been oversized by 10% relative to the normal non-dissected aorta and were implanted to cover the primary entry tear. Follow-up computed tomography scans were analyzed to define changes in aortic morphology. results: Mean radiological follow-up was 56 months (median 64.5; range 19–86.5). There was no perioperative mortality or stroke; no cases of aortic rupture were recorded during follow-up. One patient suffered a procedure-related stroke with postoperative hemiparesis following re-intervention for proximal erosion 15 months after the initial treatment. In 6 of the 7 re-interventions performed in 6 patients at a median 42 months after the index procedure, stent-graft extension was required to treat erosion of the dissection membrane that had resulted in endoleak with false lumen reperfusion. The extent of dissection, duration of follow-up, or length of aortic coverage was not predictive of the need for re-intervention during follow-up. At last follow-up, the mean false lumen diameter at the level of the stented aorta was significantly smaller than at baseline (11±15 versus 24±15 mm, pConclusion: Endovascular stent-graft treatment is effective therapy for chronic type B dissection patients with false lumen aneurysms. Erosion of the dissection membrane, causing proximal or distal endoleak, is the most common reason for re-intervention during midterm follow-up.
- 1 August 2009
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 50 (2) , 263-268
Abdominal aortic aneurysm diameter: A comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction
- 1 August 2009
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 50 (2) , 263-268
Abdominal aortic aneurysm diameter: A comparison of ultrasound measurements with those from standard and three-dimensional computed tomography reconstruction