Klaus Nielsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Klaus Nielsen has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
P. Smith
Canadian Food Inspection Agency, Ontario Laboratories (Fallowfield), 3851 Fallowfield Road, Ottawa, Ontario, Canada K2H 8P9
12 shared publicationsR. Bermudez
College of Veterinary Medicine , Universidad Autonoma de Baja California , Mexicali, Baja, Mexico
8 shared publicationsT. Renteria
College of Veterinary Medicine , Universidad Autonoma de Baja California , Mexicali, Baja, Mexico
8 shared publicationsB. Perez
SAG Laboratories, Ruta 68, Km 22, Pudahnel, Santiago, Chile
6 shared publicationsL. Samartino
INTA-CICVyA, Instituto Patobiologia, Las Cabanas y Los Reseros, 1686 Hurlingham, Buenos Aires, Argentina
6 shared publicationsW. L. Yu
Canadian Food Inspection Agency , Ottawa Laboratory (Fallowfield) , Ottawa, Ontario, Canada
6 shared publications
Latest Publications
- 30 June 2009
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 30 (3) , 313-321
Validation and Field Assessment of a Rapid Lateral Flow Assay for Detection of Bovine Antibody toAnaplasma marginale
The lateral flow assay (LFA) is a rapid diagnostic test which may be performed under most conditions and is especially useful for field applications. This type of assay was applied to the detection of antibody to bovine Anaplasma marginale using sera from endemic areas and from areas which have been free from infection for more than 25 years. Briefly, the test uses recombinant A. marginale major surface protein 5 peptide (Msp5), immobilized on a cellulose acetate membrane. A serum sample is added to a pad containing a monoclonal antibody specific for bovine IgG1, conjugated with colloidal gold, located at one end of the strip. The sample and gold conjugate are wicked along the membrane and if antibody is present in the serum, a visible line will form between the Msp5-antibody – conjugate immune complex in minutes. An additional band of recombinant protein A/G was added to the membrane as a positive control reaction of the monoclonal antibody conjugate. For comparison, direct examination of blood smears and a nested polymerase chain reaction (PCR) were performed on some of the samples. Using samples from herds in one endemic area, the PCR gave a sensitivity value of 9.2% while a commercial competitive enzyme immunoassay (CELISA) gave a sensitivity value of 17.2% and the LFA values of 20.5%. In a second endemic area, selected samples, all positive by direct examination gave a 71.7% sensitivity values with the PCR, 94.5% with the CELISA and 95.5% with the LFA. Using sera from a disease-free area, the specificity values were 100% for the PCR (testing a proportion of randomly selected samples), 99.5% for the CELISA and 98.0% for the LFA. It is envisaged that the validated LFA will be a useful tool for screening cattle moving from an area with infection to a disease-free area.
- 30 June 2009
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 30 (3) , 313-321
Validation and Field Assessment of a Rapid Lateral Flow Assay for Detection of Bovine Antibody toAnaplasma marginale
The lateral flow assay (LFA) is a rapid diagnostic test which may be performed under most conditions and is especially useful for field applications. This type of assay was applied to the detection of antibody to bovine Anaplasma marginale using sera from endemic areas and from areas which have been free from infection for more than 25 years. Briefly, the test uses recombinant A. marginale major surface protein 5 peptide (Msp5), immobilized on a cellulose acetate membrane. A serum sample is added to a pad containing a monoclonal antibody specific for bovine IgG1, conjugated with colloidal gold, located at one end of the strip. The sample and gold conjugate are wicked along the membrane and if antibody is present in the serum, a visible line will form between the Msp5-antibody – conjugate immune complex in minutes. An additional band of recombinant protein A/G was added to the membrane as a positive control reaction of the monoclonal antibody conjugate. For comparison, direct examination of blood smears and a nested polymerase chain reaction (PCR) were performed on some of the samples. Using samples from herds in one endemic area, the PCR gave a sensitivity value of 9.2% while a commercial competitive enzyme immunoassay (CELISA) gave a sensitivity value of 17.2% and the LFA values of 20.5%. In a second endemic area, selected samples, all positive by direct examination gave a 71.7% sensitivity values with the PCR, 94.5% with the CELISA and 95.5% with the LFA. Using sera from a disease-free area, the specificity values were 100% for the PCR (testing a proportion of randomly selected samples), 99.5% for the CELISA and 98.0% for the LFA. It is envisaged that the validated LFA will be a useful tool for screening cattle moving from an area with infection to a disease-free area.
- 1 October 2008
- Published by Elsevier in Veterinary Immunology and Immunopathology
- Vol. 125 (3-4) , 246-250
Validation of a second generation competitive enzyme immunoassay (CELISA) for the diagnosis of brucellosis in various species of domestic animals
- 1 October 2008
- Published by Elsevier in Veterinary Immunology and Immunopathology
- Vol. 125 (3-4) , 246-250
Validation of a second generation competitive enzyme immunoassay (CELISA) for the diagnosis of brucellosis in various species of domestic animals
- 31 December 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 29 (1) , 10-18
Development of a Lateral Flow Assay for Rapid Detection of Bovine Antibody toAnaplasma marginale
A rapid lateral flow assay for detection of bovine antibody to Anaplasma marginale was developed. The assay used a recombinant peptide of major surface protein 5 as the antigen and a monoclonal antibody specific for bovine IgG1 conjugated with colloidal gold beads for detection. Serum and anticoagulated blood samples were obtained from cattle in an area where anaplasmosis was endemic. The samples were selected based on positive identification of the organism in blood smears. The unclotted blood samples were used for PCR determination of the presence of A. marginale while the sera were tested by a commercial competitive enzyme immunoassay (CELISA) and by the lateral flow assay (LFA). Similar samples, collected at a Canadian sales barn, were tested by the CELISA and LFA and 10% were tested by PCR for the presence of A. marginale nucleic acid. In addition, stored serum samples from a second endemic area were tested by CELISA and LFA. Of the 114 smear positive samples, all were positive by CELISA and LFA. All samples were also positive by PCR. Samples from Canadian sources (n=524) were negative in the CELISA but 11 sera gave false positive reactions in the LFA. All samples tested were PCR negative. Of 113 samples from herds with anaplasmosis, 53 were positive in the CELISA and 50 were LFA positive.
- 31 December 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 29 (1) , 10-18
Development of a Lateral Flow Assay for Rapid Detection of Bovine Antibody toAnaplasma marginale
A rapid lateral flow assay for detection of bovine antibody to Anaplasma marginale was developed. The assay used a recombinant peptide of major surface protein 5 as the antigen and a monoclonal antibody specific for bovine IgG1 conjugated with colloidal gold beads for detection. Serum and anticoagulated blood samples were obtained from cattle in an area where anaplasmosis was endemic. The samples were selected based on positive identification of the organism in blood smears. The unclotted blood samples were used for PCR determination of the presence of A. marginale while the sera were tested by a commercial competitive enzyme immunoassay (CELISA) and by the lateral flow assay (LFA). Similar samples, collected at a Canadian sales barn, were tested by the CELISA and LFA and 10% were tested by PCR for the presence of A. marginale nucleic acid. In addition, stored serum samples from a second endemic area were tested by CELISA and LFA. Of the 114 smear positive samples, all were positive by CELISA and LFA. All samples were also positive by PCR. Samples from Canadian sources (n=524) were negative in the CELISA but 11 sera gave false positive reactions in the LFA. All samples tested were PCR negative. Of 113 samples from herds with anaplasmosis, 53 were positive in the CELISA and 50 were LFA positive.
- 27 September 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (4) , 307-318
Prototype Single Step Lateral Flow Technology for Detection of Avian Influenza Virus and Chicken Antibody to Avian Influenza Virus
A rapid and effective lateral flow assay (LFA) for detection of avian influenza virus (AIV) was developed. For antigen capture, the assay used monoclonal antibody specific for a conserved nuclear protein (NP) epitope, immobilized on a cellulose acetate matrix, in conjunction with a second NP monoclonal antibody chemically linked to either coloured latex beads or colloidal gold particles contained in a sample pad for detection. Virus sample added to the sample pad flowed into the trapping antibody to form a visible band as well as a second, control band further along the acetate strip. The control band consisted of recombinant protein A/G, also immobilized on the matrix. A second LFA for detection of chicken antibody to AIV was developed where NP antigen was immobilized on the matrix with recombinant protein A/G immobilized as a control band. Latex beads or colloidal gold particles to which monoclonal anti‐chicken antibody was attached, were used as the indicator system.
- 27 September 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (4) , 307-318
Prototype Single Step Lateral Flow Technology for Detection of Avian Influenza Virus and Chicken Antibody to Avian Influenza Virus
A rapid and effective lateral flow assay (LFA) for detection of avian influenza virus (AIV) was developed. For antigen capture, the assay used monoclonal antibody specific for a conserved nuclear protein (NP) epitope, immobilized on a cellulose acetate matrix, in conjunction with a second NP monoclonal antibody chemically linked to either coloured latex beads or colloidal gold particles contained in a sample pad for detection. Virus sample added to the sample pad flowed into the trapping antibody to form a visible band as well as a second, control band further along the acetate strip. The control band consisted of recombinant protein A/G, also immobilized on the matrix. A second LFA for detection of chicken antibody to AIV was developed where NP antigen was immobilized on the matrix with recombinant protein A/G immobilized as a control band. Latex beads or colloidal gold particles to which monoclonal anti‐chicken antibody was attached, were used as the indicator system.
- 1 September 2007
- Published by Elsevier in Veterinary Microbiology
- Vol. 124 (1-2) , 173-177
Second generation competitive enzyme immunoassay for detection of bovine antibody to Brucella abortus
- 1 September 2007
- Published by Elsevier in Veterinary Microbiology
- Vol. 124 (1-2) , 173-177
Second generation competitive enzyme immunoassay for detection of bovine antibody to Brucella abortus
- 1 July 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (3) , 243-250
Detection of Ovine Antibody toBrucella ovisby Indirect Enzyme Immunoassay
Because some batch‐to‐batch variation in the preparation of rough lipopolysaccharide (RLPS) from Brucella ovis has been experienced, several protocols were tested to establish the most reliable method for detection of antibody in indirect enzyme immunoassay. An early version of the assay gave a performance index (PI=sum of optimum percent sensitivity and percent specificity, determined by receiver operator characteristic analysis) of 198.6. This assay used RLPS from B. ovis as the antigen and a monoclonal antibody specific for bovine IgG1 heavy chain‐enzyme conjugate for detection. This was not repeatable using other batches of antigen. Newer versions of the assay generally had decreased sensitivity values, giving PIs of 193. Use of a recombinant protein A/G‐enzyme conjugate did not improve the PI (PI=190), giving reduced specificity and higher sensitivity. The final version used B. abortus RB51 RLPS as the antigen and protein A/G‐enzyme conjugate for detection, giving a PI of 197. Because of the batch uniformity of the B. abortus RB51 RLPS and the versatility of the protein A/G‐enzyme conjugate, the latter version appears to be the most useful for diagnostic serology.
- 1 July 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (3) , 243-250
Detection of Ovine Antibody toBrucella ovisby Indirect Enzyme Immunoassay
Because some batch‐to‐batch variation in the preparation of rough lipopolysaccharide (RLPS) from Brucella ovis has been experienced, several protocols were tested to establish the most reliable method for detection of antibody in indirect enzyme immunoassay. An early version of the assay gave a performance index (PI=sum of optimum percent sensitivity and percent specificity, determined by receiver operator characteristic analysis) of 198.6. This assay used RLPS from B. ovis as the antigen and a monoclonal antibody specific for bovine IgG1 heavy chain‐enzyme conjugate for detection. This was not repeatable using other batches of antigen. Newer versions of the assay generally had decreased sensitivity values, giving PIs of 193. Use of a recombinant protein A/G‐enzyme conjugate did not improve the PI (PI=190), giving reduced specificity and higher sensitivity. The final version used B. abortus RB51 RLPS as the antigen and protein A/G‐enzyme conjugate for detection, giving a PI of 197. Because of the batch uniformity of the B. abortus RB51 RLPS and the versatility of the protein A/G‐enzyme conjugate, the latter version appears to be the most useful for diagnostic serology.
- 1 July 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (3) , 289-296
Salmonella enterica Serotype Urbana Interference with Brucellosis Serology
Sheep were immunized with killed Salmonella enterica serotype Urbana cells and their sera were tested in various serological tests for antibody to Brucella sp., Yersinia enterocolitica O:9 and Escherichia coli O:157 H:7. Of the eight sheep, all gave a positive agglutination reaction in the brucellosis buffered antigen plate agglutination test (BPAT), seven gave positive brucellosis standard tube agglutination test (TAT) and complement fixation test (CFT) results and four gave slightly positive reactions in a competitive enzyme immunoassay (CELISA). Seven sera were negative in an indirect enzyme immunoassay (IELISA‐SLPS) using B. abortus smooth lipopolysaccharide (SLPS) antigen and all were negative in a fluorescence polarization assay (FPA‐OPS) using B. abortus O‐polysaccharide antigen. Two sheep gave a slight positive reaction in an IELISA using Brucella rough lipopolysaccharide antigen (IELISA‐RLPS) and four sheep were slightly positive in an FPA using Brucella LPS core antigen (FPA‐CORE). All sheep had high antibody responses to S. enterica serotype Urbana, Y. and E. coli O:157 and 7 were positive for antibody to Y. enterocolitica O:9 when tested by IELISA. The sheep were negative when tested in the FPA using OPS from Y. enterocolitica O:9 but all were strongly positive in the FPA using OPS from E. coli O:157 while seven sheep had titers to S. enterica serotype Urbana. The impact on diagnostic serology for brucellosis is discussed.
- 1 July 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (3) , 289-296
Salmonella enterica Serotype Urbana Interference with Brucellosis Serology
Sheep were immunized with killed Salmonella enterica serotype Urbana cells and their sera were tested in various serological tests for antibody to Brucella sp., Yersinia enterocolitica O:9 and Escherichia coli O:157 H:7. Of the eight sheep, all gave a positive agglutination reaction in the brucellosis buffered antigen plate agglutination test (BPAT), seven gave positive brucellosis standard tube agglutination test (TAT) and complement fixation test (CFT) results and four gave slightly positive reactions in a competitive enzyme immunoassay (CELISA). Seven sera were negative in an indirect enzyme immunoassay (IELISA‐SLPS) using B. abortus smooth lipopolysaccharide (SLPS) antigen and all were negative in a fluorescence polarization assay (FPA‐OPS) using B. abortus O‐polysaccharide antigen. Two sheep gave a slight positive reaction in an IELISA using Brucella rough lipopolysaccharide antigen (IELISA‐RLPS) and four sheep were slightly positive in an FPA using Brucella LPS core antigen (FPA‐CORE). All sheep had high antibody responses to S. enterica serotype Urbana, Y. and E. coli O:157 and 7 were positive for antibody to Y. enterocolitica O:9 when tested by IELISA. The sheep were negative when tested in the FPA using OPS from Y. enterocolitica O:9 but all were strongly positive in the FPA using OPS from E. coli O:157 while seven sheep had titers to S. enterica serotype Urbana. The impact on diagnostic serology for brucellosis is discussed.
- 1 July 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (3) , 251-265
Detection ofEschericia coliO157:H7 by Fluorescence Polarization Assay and Polymerase Chain Reaction
It is recognized that cattle and other domestic animals can be a reservoir of pathogenic Escherichia coli, including serotype O157:H7. To contain this potential health hazard, the first step is the identification of the carrier animals. For these purposes, a rapid serological screening test, a fluorescence polarization assay (FPA) was developed and results obtained from a randomly selected cattle population as well as cattle immunized with E. coli O157:H7 were compared to those obtained with an indirect enzyme immunoassay (IELISA). To identify pathogenic strains in carrier animals, polymerase chain reactions (PCR) for Shiga‐like toxins I and II were implemented using agarose electrophoresis. The sensitivity of the fecal extracted E. coli for Shiga‐like toxin I and II was approximately 200 CFU per reaction using multiplex hot‐start nested PCR. The sensitivity of the fecal extracted E. coli varied from approximately 5×102 to 2.5×103 CFU per reaction depending on the commercial kits used. The combination of the serological screening FPA and hot‐start nested PCR confirmatory assays provided rapid identification of the pathogen.
- 1 July 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (3) , 251-265
Detection ofEschericia coliO157:H7 by Fluorescence Polarization Assay and Polymerase Chain Reaction
It is recognized that cattle and other domestic animals can be a reservoir of pathogenic Escherichia coli, including serotype O157:H7. To contain this potential health hazard, the first step is the identification of the carrier animals. For these purposes, a rapid serological screening test, a fluorescence polarization assay (FPA) was developed and results obtained from a randomly selected cattle population as well as cattle immunized with E. coli O157:H7 were compared to those obtained with an indirect enzyme immunoassay (IELISA). To identify pathogenic strains in carrier animals, polymerase chain reactions (PCR) for Shiga‐like toxins I and II were implemented using agarose electrophoresis. The sensitivity of the fecal extracted E. coli for Shiga‐like toxin I and II was approximately 200 CFU per reaction using multiplex hot‐start nested PCR. The sensitivity of the fecal extracted E. coli varied from approximately 5×102 to 2.5×103 CFU per reaction depending on the commercial kits used. The combination of the serological screening FPA and hot‐start nested PCR confirmatory assays provided rapid identification of the pathogen.
- 2 January 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (1) , 61-66
Detection of Anti‐BrucellaAntibodies in Llama (Lama glama)
Seven llamas were immunized with killed Brucella abortus S1119.3 cells and bled sequentially, resulting in 64 samples. An eighth llama was kept as a negative control. In addition, 299 llama and 2075 alpaca sera, submitted for diagnostic testing, were included. Sera from all llamas were tested by the buffered antigen plate agglutination test, the complement fixation test, and the indirect enzyme immunoassays using smooth and rough lipopolysaccharides. A competitive enzyme immunoassay and fluorescence polarization assays were also performed. The sensitivity values for llama sera ranged from 92.2% to 100% and the specificity values from 89.6% to 100%. No alpacas were immunized. The specificity values for alpaca sera ranged from 94.8% to 100% specific although some sera gave an ‘agglutination like’ reaction after about 10 minutes of incubation. The complement fixation test could not be used, as 31% of the sera were anticomplementary and 4% were false positive.
- 2 January 2007
- Published by Taylor & Francis in Journal of Immunoassay and Immunochemistry
- Vol. 28 (1) , 61-66
Detection of Anti‐BrucellaAntibodies in Llama (Lama glama)
Seven llamas were immunized with killed Brucella abortus S1119.3 cells and bled sequentially, resulting in 64 samples. An eighth llama was kept as a negative control. In addition, 299 llama and 2075 alpaca sera, submitted for diagnostic testing, were included. Sera from all llamas were tested by the buffered antigen plate agglutination test, the complement fixation test, and the indirect enzyme immunoassays using smooth and rough lipopolysaccharides. A competitive enzyme immunoassay and fluorescence polarization assays were also performed. The sensitivity values for llama sera ranged from 92.2% to 100% and the specificity values from 89.6% to 100%. No alpacas were immunized. The specificity values for alpaca sera ranged from 94.8% to 100% specific although some sera gave an ‘agglutination like’ reaction after about 10 minutes of incubation. The complement fixation test could not be used, as 31% of the sera were anticomplementary and 4% were false positive.
- 1 January 2006
- Published by Elsevier in Veterinary Immunology and Immunopathology
- Vol. 109 (1-2) , 69-78
Serological discrimination by indirect enzyme immunoassay between the antibody response to Brucella sp. and Yersinia enterocolitica O:9 in cattle and pigs
- 1 January 2006
- Published by Elsevier in Veterinary Immunology and Immunopathology
- Vol. 109 (1-2) , 69-78
Serological discrimination by indirect enzyme immunoassay between the antibody response to Brucella sp. and Yersinia enterocolitica O:9 in cattle and pigs