Jinho Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jinho Lee has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Inapura Siddagangaiah Shivakumara
Department of Mathematics, Bangalore University, Bangalore 560 056, India
12 shared publications - M. Ravisha
Department of Mathematics, Government First Grade College, Davanagere, India
4 shared publications - C. E. Nanjundappa
Dr. Ambedkar Institute of Technology
3 shared publications M. Ravisha
Department of Mathematics, Dr. G Shankar Government Women’s First Grade College and Post Graduate Study Centre, Udupi, India
3 shared publications- Chikkanalluru Erappa Nanjundappa
Department of Mathematics, Dr. Ambedkar Institute of Technology, Bengaluru, India
2 shared publications - Dhananjay Yadav
Department of Mathematical and Physical Sciences, University of Nizwa
2 shared publications
Latest Publications
- Open Access
- 3 March 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (3) , 248
The Effects of Wet Compression by the Electronic Expansion Valve Opening on the Performance of a Heat Pump System
In this study, by controlling the Electronic Expansion Valve opening, the influence of wet compression on a heat pump system was experimentally investigated in different heating conditions. The results demonstrate that the discharge temperature decreased and the mass flow rate increased, due to quality of the rising liquid droplets. It was also found that the heating capacity and power input of wet compression increased more than that of dry compression, with a superheat of 10 °C. The maximum COP (Coefficient of Performance) exists at a specific quality of ca. 0.94 to 0.90, as the power input in the region of wet compression is proportionally larger than the increase in the heating capacity, according to the decreasing quality. When the Entering Water Temperature of the Outdoor Heat Exchanger was 10 °C, 5 °C, and 0 °C, the COP increased by a maximum of ca. 12.4%, 10.6%, and 10.2%, respectively, in comparison to the superheat of 10 °C. In addition, the superheat at the discharge line is proposed as a proper controlling parameter to adjust the quality at the suction line, by varying the opening of the expansion valve during wet compression.
- 3 March 2017
- Published by MDPI AG in Applied Sciences
- Vol. 7 (3) , 248
Open AccessThe Effects of Wet Compression by the Electronic Expansion Valve Opening on the Performance of a Heat Pump System
In this study, by controlling the Electronic Expansion Valve opening, the influence of wet compression on a heat pump system was experimentally investigated in different heating conditions. The results demonstrate that the discharge temperature decreased and the mass flow rate increased, due to quality of the rising liquid droplets. It was also found that the heating capacity and power input of wet compression increased more than that of dry compression, with a superheat of 10 °C. The maximum COP (Coefficient of Performance) exists at a specific quality of ca. 0.94 to 0.90, as the power input in the region of wet compression is proportionally larger than the increase in the heating capacity, according to the decreasing quality. When the Entering Water Temperature of the Outdoor Heat Exchanger was 10 °C, 5 °C, and 0 °C, the COP increased by a maximum of ca. 12.4%, 10.6%, and 10.2%, respectively, in comparison to the superheat of 10 °C. In addition, the superheat at the discharge line is proposed as a proper controlling parameter to adjust the quality at the suction line, by varying the opening of the expansion valve during wet compression.
- 22 February 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 22 (4) , 372-378
Optimized operation method for an active chilled beam with VAV system
The chilled beam system is a popular energy saving system and it has been applied in Europe, the United States, and other countries for many years. There are two main types of chilled beams, such as the active chilled beam and passive chilled beam. The active chilled beam operates on the primary airflow, which induces airflow from the space through the cooling coil. This provides much more cooling capacity than a passive chilled beam working on a natural circulation flow. The efficient operation of the primary air unit is important to save the energy consumption from the fan and cooling capacity of the primary air unit. In this study, energy efficiency and efficient performance of the active beams with variable air volume (VAV) system was studied by simulation of the optimizing variable control parameters; the chilled beam efficiency difference was discussed considering the ratio between a primary air capacity and a chilled water capacity.
- 22 February 2016
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 22 (4) , 372-378
Optimized operation method for an active chilled beam with VAV system
The chilled beam system is a popular energy saving system and it has been applied in Europe, the United States, and other countries for many years. There are two main types of chilled beams, such as the active chilled beam and passive chilled beam. The active chilled beam operates on the primary airflow, which induces airflow from the space through the cooling coil. This provides much more cooling capacity than a passive chilled beam working on a natural circulation flow. The efficient operation of the primary air unit is important to save the energy consumption from the fan and cooling capacity of the primary air unit. In this study, energy efficiency and efficient performance of the active beams with variable air volume (VAV) system was studied by simulation of the optimizing variable control parameters; the chilled beam efficiency difference was discussed considering the ratio between a primary air capacity and a chilled water capacity.
- 17 February 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 138 (5) , 052901
Derivation and Validation of a Figure of Merit for Loop Heat Pipes With Medium Temperature Working Fluids
The working fluids of loop heat pipes (LHPs) play an important role in the operation of the LHPs by influencing the operating temperatures and the heat transfer limits. Therefore, the proper selection of a working fluid is a key practice in LHP fabrication, and there has been a high demand for an appropriate index that enables the quantitative comparison of the steady-state thermal performance of the working fluids. In this work, a figure of merit for LHPs was theoretically derived and experimentally verified. In particular, the pressure losses in the LHP operation were balanced with the saturation pressure difference between the evaporator and the compensation chamber to derive the figure of merit. This derived figure of merit for LHPs successfully predicted the steady-state thermal performance of the tested working fluids within the variable conductance regime. In the constant conductance regime, the differences in the condenser cooling capacity and in the liquid subcooling for different working fluids determined the thermal performance of each working fluid. The limitations and prospects of the proposed figure of merit were discussed in detail.
- 17 February 2016
- Published by Wiley in Journal of Heat Transfer
- Vol. 138 (5) , 052901
Derivation and Validation of a Figure of Merit for Loop Heat Pipes With Medium Temperature Working Fluids
The working fluids of loop heat pipes (LHPs) play an important role in the operation of the LHPs by influencing the operating temperatures and the heat transfer limits. Therefore, the proper selection of a working fluid is a key practice in LHP fabrication, and there has been a high demand for an appropriate index that enables the quantitative comparison of the steady-state thermal performance of the working fluids. In this work, a figure of merit for LHPs was theoretically derived and experimentally verified. In particular, the pressure losses in the LHP operation were balanced with the saturation pressure difference between the evaporator and the compensation chamber to derive the figure of merit. This derived figure of merit for LHPs successfully predicted the steady-state thermal performance of the tested working fluids within the variable conductance regime. In the constant conductance regime, the differences in the condenser cooling capacity and in the liquid subcooling for different working fluids determined the thermal performance of each working fluid. The limitations and prospects of the proposed figure of merit were discussed in detail.
- 14 August 2015
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 130 (8) , 1-22
The onset of MHD nanofluid convection with Hall current effect
- 14 August 2015
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 130 (8) , 1-22
The onset of MHD nanofluid convection with Hall current effect
- 31 December 2014
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 27 (1) , 27-37
Effect of Coriolis Force on Bénard–Marangoni Convection in a Rotating Ferrofluid Layer with MFD Viscosity
- 31 December 2014
- Published by Springer Nature in Microgravity Science and Technology
- Vol. 27 (1) , 27-37
Effect of Coriolis Force on Bénard–Marangoni Convection in a Rotating Ferrofluid Layer with MFD Viscosity
- 18 March 2014
- Published by Springer Nature in Meccanica
- Vol. 49 (5) , 1139-1157
Effect of rotation on ferromagnetic porous convection with a thermal non-equilibrium model
- 18 March 2014
- Published by Springer Nature in Meccanica
- Vol. 49 (5) , 1139-1157
Effect of rotation on ferromagnetic porous convection with a thermal non-equilibrium model
- 28 December 2013
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 27 (12) , 3875-3884
Brinkman ferromagnetic convection in a porous layer: Effect of MFD viscosity and magnetic boundaries
- 28 December 2013
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 27 (12) , 3875-3884
Brinkman ferromagnetic convection in a porous layer: Effect of MFD viscosity and magnetic boundaries
- 1 July 2012
- Published by The Korean Society of Mechanical Engineers in Transactions of the Korean Society of Mechanical Engineers - B
- Vol. 36 (7) , 683-687
Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser
- 1 July 2012
- Published by The Korean Society of Mechanical Engineers in Transactions of the Korean Society of Mechanical Engineers - B
- Vol. 36 (7) , 683-687
Study on Indoor Flow According to Vane Angle of Square Ceiling Type Louver Diffuser
- 1 July 2012
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 55 (15-16) , 3995-4002
Turbulence characteristics and vortical structures in combined-convection boundary layers along a heated vertical flat plate
- 1 July 2012
- Published by Elsevier in International Journal of Heat and Mass Transfer
- Vol. 55 (15-16) , 3995-4002
Turbulence characteristics and vortical structures in combined-convection boundary layers along a heated vertical flat plate