Souvik Bhattacharyya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Souvik Bhattacharyya has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
M. Ram Gopal
Department of Mechanical Engineering , Indian Institute of Technology Kharagpur , Kharagpur, India
3 shared publications- Prasanta Kumar Das
Department of Mechanical Engineering, IIT Kharagpur, Kharagpur, India
3 shared publications David A. Blank
Department of Mechanical Engineering, Indian Institute of Technology, Kharagpur 721302, India
2 shared publications- Dipankar N. Basu
Department of Mechanical Engineering, IIT, Kharagpur 721302, India
2 shared publications - Jahar Sarkar
Department of Mechanical Engineering Indian Institute of Technology (B.H.U.) Varanasi India
2 shared publications Neeraj Agrawal
Department of Mechanical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, India
2 shared publications
Latest Publications
- 1 December 2013
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 265, 411-423
Hydrodynamics of a natural circulation loop in a scaled-down steam drum-riser-downcomer assembly
- 1 December 2013
- Published by Elsevier in Nuclear Engineering and Design
- Vol. 265, 411-423
Hydrodynamics of a natural circulation loop in a scaled-down steam drum-riser-downcomer assembly
- 1 November 2009
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 33 (14) , 1278-1289
Exergy assessment of an optimized capillary tube-based transcritical CO2heat pump system
- 1 November 2009
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 33 (14) , 1278-1289
Exergy assessment of an optimized capillary tube-based transcritical CO2heat pump system
- 5 January 2009
- Published by Wiley in Journal of Heat Transfer
- Vol. 131 (2) , 022901
Steady-State Behavior of a Two-Phase Natural Circulation Loop With Thermodynamic Nonequilibrium
A model to predict the steady-state behavior of a rectangular two-phase natural circulation loop has been proposed. The analysis employs a one-dimensional two-fluid model to identify various system parameters, with particular emphasis on the subcooled boiling region. The onset of two-phase region and point of net vapor generation and associated liquid temperatures and vapor qualities have been estimated using a few widely recognized correlations. Predicted results demonstrate that the consideration of subcooled boiling may have significant effect on system behavior, particularly around the transition regions. The interaction of saturated bubbles and subcooled liquid and associated change in heat transfer and frictional forces has been discussed in detail. Fluid stream has been observed to have different combinations of flow stream conditions at boiler exit and condenser inlet. Five probable combinations have been identified and a generalized working-regime map has been proposed on Nsub−NZu plane. Attempts have been made to identify the influence of various control parameters. A favorable sink condition (higher coolant flow rate or lower coolant entry temperature) has been found to be of particular importance to attain a wider operating range of wall heat flux and better heat transfer characteristics. A design map has been proposed to identify favorable operating condition in terms of control parameters to ensure complete condensation.
- 5 January 2009
- Published by Wiley in Journal of Heat Transfer
- Vol. 131 (2) , 022901
Steady-State Behavior of a Two-Phase Natural Circulation Loop With Thermodynamic Nonequilibrium
A model to predict the steady-state behavior of a rectangular two-phase natural circulation loop has been proposed. The analysis employs a one-dimensional two-fluid model to identify various system parameters, with particular emphasis on the subcooled boiling region. The onset of two-phase region and point of net vapor generation and associated liquid temperatures and vapor qualities have been estimated using a few widely recognized correlations. Predicted results demonstrate that the consideration of subcooled boiling may have significant effect on system behavior, particularly around the transition regions. The interaction of saturated bubbles and subcooled liquid and associated change in heat transfer and frictional forces has been discussed in detail. Fluid stream has been observed to have different combinations of flow stream conditions at boiler exit and condenser inlet. Five probable combinations have been identified and a generalized working-regime map has been proposed on Nsub−NZu plane. Attempts have been made to identify the influence of various control parameters. A favorable sink condition (higher coolant flow rate or lower coolant entry temperature) has been found to be of particular importance to attain a wider operating range of wall heat flux and better heat transfer characteristics. A design map has been proposed to identify favorable operating condition in terms of control parameters to ensure complete condensation.
- Open Access
- 1 January 2009
- Published by National Library of Serbia in Thermal Science
- Vol. 13 (2) , 97-112
How good is Goodman's heat-balance integral method for analyzing the rewetting of hot surfaces?
This paper discusses the application of heat-balance integral method for solving the conduction equation in a variety of rewetting problems. A host of rewetting problems for various geometry, convective boundary conditions and internal heat generation as well as for variable property has been solved by employing the method. Closed form expressions for rewetting velocity and temperature field in the hot solid have been obtained. Further, a unified solution methodology for different geometry and dimension of the problem has been derived. The results obtained agrees well with other analytical techniques namely, Winer-Hopf technique, separation of variables method as well as with the numerical ones. The predicted solutions exhibit a good agreement with experimental data as well. Additionally, an optimal linearization technique has been applied to analyze the effect of temperature dependent properties on the phenomena of rewetting. The results obtained and optimal linearization techniques have been compared and a good agreement has been obtained. All the studies made so far demonstrates the suitability of employing HBIM in the analysis of various rewetting problems.
- 1 January 2009
- Published by National Library of Serbia in Thermal Science
- Vol. 13 (2) , 97-112
Open AccessHow good is Goodman's heat-balance integral method for analyzing the rewetting of hot surfaces?
This paper discusses the application of heat-balance integral method for solving the conduction equation in a variety of rewetting problems. A host of rewetting problems for various geometry, convective boundary conditions and internal heat generation as well as for variable property has been solved by employing the method. Closed form expressions for rewetting velocity and temperature field in the hot solid have been obtained. Further, a unified solution methodology for different geometry and dimension of the problem has been derived. The results obtained agrees well with other analytical techniques namely, Winer-Hopf technique, separation of variables method as well as with the numerical ones. The predicted solutions exhibit a good agreement with experimental data as well. Additionally, an optimal linearization technique has been applied to analyze the effect of temperature dependent properties on the phenomena of rewetting. The results obtained and optimal linearization techniques have been compared and a good agreement has been obtained. All the studies made so far demonstrates the suitability of employing HBIM in the analysis of various rewetting problems.
- 1 February 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (2) , 024504
Rewetting Analysis of Hot Vertical Surfaces With Precursory Cooling by the Heat Balance Integral Method
The effect of precursory cooling on conduction-controlled rewetting of both slab and solid cylinder is analyzed by the heat balance integral method. A constant heat transfer coefficient is assumed in the wet region behind the wet front, while an exponentially decaying heat flux is assumed in the dry region ahead of the wet front. The physical problem is characterized by two dimensionless constants describing the extent of precursory cooling and three dimensionless numbers, namely, Peclet number, Biot number, and the nondimensional temperature. Results of the present solution are found to be in good agreement with other analytical solutions obtained through the Weiner–Hopf technique and the separation of variables as well as with the published experimental data for different coolants over a varied range of coolant flow rate. It is seen that precursory cooling increases the rewetting velocity particularly at higher flow rates. If it is neglected, the model grossly underpredicts the quench velocities.
- 1 February 2008
- Published by Wiley in Journal of Heat Transfer
- Vol. 130 (2) , 024504
Rewetting Analysis of Hot Vertical Surfaces With Precursory Cooling by the Heat Balance Integral Method
The effect of precursory cooling on conduction-controlled rewetting of both slab and solid cylinder is analyzed by the heat balance integral method. A constant heat transfer coefficient is assumed in the wet region behind the wet front, while an exponentially decaying heat flux is assumed in the dry region ahead of the wet front. The physical problem is characterized by two dimensionless constants describing the extent of precursory cooling and three dimensionless numbers, namely, Peclet number, Biot number, and the nondimensional temperature. Results of the present solution are found to be in good agreement with other analytical solutions obtained through the Weiner–Hopf technique and the separation of variables as well as with the published experimental data for different coolants over a varied range of coolant flow rate. It is seen that precursory cooling increases the rewetting velocity particularly at higher flow rates. If it is neglected, the model grossly underpredicts the quench velocities.
- 29 December 2006
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 31 (11) , 1016-1030
Adiabatic capillary tube flow of carbon dioxide in a transcritical heat pump cycle
Flow characteristics of an adiabatic capillary tube in a transcritical CO2 heat pump system have been investigated employing the homogeneous model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factor empirical correlations (Churchill, Lin et al., Int. J. Multiphase Flow 1991; 17(1):95–102) and four viscosity models (Mcadams, Cicchitti, Dukler and Lin) are comparatively used to investigate the flow characteristics. Choked condition at the outlet is also investigated for maximum mass flow rate. Subcritical and supercritical thermodynamic and transport properties of CO2 are calculated employing a precision property code. Choice of viscosity model causes minor variation in results unlike in chlorofluorocarbons (CFCs) refrigerants. Relationships between cooling capacity with capillary tube diameter, length and maximum mass flow rate are presented. A lower evaporating temperature yields a larger cooling capacity due to the unique thermodynamic properties of CO2. It is also observed that an optimum cooling capacity exists for a specified capillary tube. Copyright © 2006 John Wiley & Sons, Ltd.
- 29 December 2006
- Published by Hindawi Limited in International Journal of Energy Research
- Vol. 31 (11) , 1016-1030
Adiabatic capillary tube flow of carbon dioxide in a transcritical heat pump cycle
Flow characteristics of an adiabatic capillary tube in a transcritical CO2 heat pump system have been investigated employing the homogeneous model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factor empirical correlations (Churchill, Lin et al., Int. J. Multiphase Flow 1991; 17(1):95–102) and four viscosity models (Mcadams, Cicchitti, Dukler and Lin) are comparatively used to investigate the flow characteristics. Choked condition at the outlet is also investigated for maximum mass flow rate. Subcritical and supercritical thermodynamic and transport properties of CO2 are calculated employing a precision property code. Choice of viscosity model causes minor variation in results unlike in chlorofluorocarbons (CFCs) refrigerants. Relationships between cooling capacity with capillary tube diameter, length and maximum mass flow rate are presented. A lower evaporating temperature yields a larger cooling capacity due to the unique thermodynamic properties of CO2. It is also observed that an optimum cooling capacity exists for a specified capillary tube. Copyright © 2006 John Wiley & Sons, Ltd.
- 1 December 2006
- Published by Taylor & Francis in Drying Technology
- Vol. 24 (12) , 1583-1591
Transcritical CO2Heat Pump Dryer: Part 1. Mathematical Model and Simulation
In this study, a mathematical model and simulation code has been developed to investigate the performance of a transcritical CO2 heat pump dryer. The model takes into account detailed heat and mass transfer and pressure drop phenomena occurring in each component of the system. To take care of the variable heat transfer properties, the heat exchanger components were divided into several infinitesimal segments to examine the state, heat and mass balance and pressure drop for both refrigerant and air, and hence accurate results are expected. In Part 2 of the article, the model developed has been validated with experimental data and then the model was used to investigate effects of important operating parameters on the performance.
- 1 December 2006
- Published by Taylor & Francis in Drying Technology
- Vol. 24 (12) , 1583-1591
Transcritical CO2Heat Pump Dryer: Part 1. Mathematical Model and Simulation
In this study, a mathematical model and simulation code has been developed to investigate the performance of a transcritical CO2 heat pump dryer. The model takes into account detailed heat and mass transfer and pressure drop phenomena occurring in each component of the system. To take care of the variable heat transfer properties, the heat exchanger components were divided into several infinitesimal segments to examine the state, heat and mass balance and pressure drop for both refrigerant and air, and hence accurate results are expected. In Part 2 of the article, the model developed has been validated with experimental data and then the model was used to investigate effects of important operating parameters on the performance.
- 1 December 2006
- Published by Taylor & Francis in Drying Technology
- Vol. 24 (12) , 1593-1600
Transcritical CO2Heat Pump Dryer: Part 2. Validation and Simulation Results
The simulation model of a transcritical CO2 heat pump dryer presented in Part 1 has been first validated with available experimental data in this part and then used to simulate the heat pump dryer to study the variation of performance parameters such as heating COP, moisture extraction rate, and specific moisture extraction rate. The validation with experimental data shows that the model slightly over predicts the system performance. The possible reasons for the difference between experimental and numerical results are explained. Simulation results show the effect of key operating parameters such as bypass air ratio, re-circulation air ratio, dryer efficiency, ambient condition (temperature and relative humidity), and air mass flow rate. Results show that unlike bypass air ratio and ambient relative humidity, the effect of dryer efficiency, recirculation air ratio, ambient temperature, and air mass flow rate are very significant as far as the system performance is concerned.
- 1 December 2006
- Published by Taylor & Francis in Drying Technology
- Vol. 24 (12) , 1593-1600
Transcritical CO2Heat Pump Dryer: Part 2. Validation and Simulation Results
The simulation model of a transcritical CO2 heat pump dryer presented in Part 1 has been first validated with available experimental data in this part and then used to simulate the heat pump dryer to study the variation of performance parameters such as heating COP, moisture extraction rate, and specific moisture extraction rate. The validation with experimental data shows that the model slightly over predicts the system performance. The possible reasons for the difference between experimental and numerical results are explained. Simulation results show the effect of key operating parameters such as bypass air ratio, re-circulation air ratio, dryer efficiency, ambient condition (temperature and relative humidity), and air mass flow rate. Results show that unlike bypass air ratio and ambient relative humidity, the effect of dryer efficiency, recirculation air ratio, ambient temperature, and air mass flow rate are very significant as far as the system performance is concerned.
- 15 April 2005
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 128 (1) , 35-43
Dynamic Performance Analysis of a Compressor Driven Metal Hydride Cooling System
Though several studies have been reported to show that compressor driven metal hydride cooling systems are competitive with conventional vapor compression systems, an elaborate computational model that takes into account the transient nature of the compressor and the conditioned space is still unreported. The results presented here are obtained for a room air conditioner with Zr0.9Ti0.1Cr0.55Fe1.45 as the hydrogen absorbing material and employing standard heat exchanger configurations. Though previous thermodynamic and transient studies predicted attainment of significant coefficients of performance, the present results indicate that even with the optimal design the maximum coefficient of performance and specific power will be around 2.38 and 750kJ∕kg-alloy.h, respectively. This indicates a need for better materials and effective control strategies so that these systems can become commercially viable.
- 15 April 2005
- Published by Wiley in Journal of Energy Resources Technology
- Vol. 128 (1) , 35-43
Dynamic Performance Analysis of a Compressor Driven Metal Hydride Cooling System
Though several studies have been reported to show that compressor driven metal hydride cooling systems are competitive with conventional vapor compression systems, an elaborate computational model that takes into account the transient nature of the compressor and the conditioned space is still unreported. The results presented here are obtained for a room air conditioner with Zr0.9Ti0.1Cr0.55Fe1.45 as the hydrogen absorbing material and employing standard heat exchanger configurations. Though previous thermodynamic and transient studies predicted attainment of significant coefficients of performance, the present results indicate that even with the optimal design the maximum coefficient of performance and specific power will be around 2.38 and 750kJ∕kg-alloy.h, respectively. This indicates a need for better materials and effective control strategies so that these systems can become commercially viable.
- 11 October 2001
- Published by Elsevier in Energy Conversion and Management
- Vol. 42 (15-17) , 2019-2027
Catalytic reduction of NOx in gasoline engine exhaust over copper- and nickel-exchanged X–zeolite catalysts
- 11 October 2001
- Published by Elsevier in Energy Conversion and Management
- Vol. 42 (15-17) , 2019-2027
Catalytic reduction of NOx in gasoline engine exhaust over copper- and nickel-exchanged X–zeolite catalysts