Vladimir Horvat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Vladimir Horvat has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
R. L. Watson
Cyclotron Institute and Department of Chemistry, Texas A&M University, College Station, Texas 77843-3366, USA
6 shared publicationsJ. M. Blackadar
Cyclotron Institute and Department of Chemistry, Texas A&M University, College Station, Texas 77843-3366, USA
2 shared publicationsR.L. Watson
Cyclotron Institute and Department of Chemistry, Texas A&M University, College Station, TX 77843-3366, USA
2 shared publicationsY. Peng
Cyclotron Institute and Department of Chemistry, Texas A&M University, College Station, Texas 77843-3366, USA
2 shared publicationsYong Peng
Cyclotron Institute and Department of Chemistry, Texas A&M University, College Station, Texas 77843-3366, USA
2 shared publicationsA. N. Perumal
Cyclotron Institute and Department of Chemistry, Texas A&M University, College Station, Texas 77843-3366, USA
1 shared publication
Latest Publications
- 1 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Recent Developments to the Texas A&M University Cyclotron Institute Radiation Effects Facility from 2019-2023
The Texas A&M University Cyclotron Institute Radiation Effects Facility has made several facility developments in the preceding years including the addition of 9.4 and 15 MeV/u heavy ion beams to the K150 SEELine, a new heavy ion beam to the K500 SEELine, a second ECR ion source for the K500 SEELine, and a remote DUT heating system to both SEELines. The additions of heavy ion beam testing to the K150 SEELine and the second ECR ion source to the K500 in particular have improved reliability and uptime of beam hours provided by the Cyclotron Institute to address the growing demand for beam time in the radiation effects testing industry.
- 1 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Recent Developments to the Texas A&M University Cyclotron Institute Radiation Effects Facility from 2019-2023
The Texas A&M University Cyclotron Institute Radiation Effects Facility has made several facility developments in the preceding years including the addition of 9.4 and 15 MeV/u heavy ion beams to the K150 SEELine, a new heavy ion beam to the K500 SEELine, a second ECR ion source for the K500 SEELine, and a remote DUT heating system to both SEELines. The additions of heavy ion beam testing to the K150 SEELine and the second ECR ion source to the K500 in particular have improved reliability and uptime of beam hours provided by the Cyclotron Institute to address the growing demand for beam time in the radiation effects testing industry.
- 24 November 2022
- Published by Elsevier in Computer Physics Communications
- Vol. 284
FITEVT: A FORTRAN program for arrival-time analysis of nuclear-decay events
- 24 November 2022
- Published by Elsevier in Computer Physics Communications
- Vol. 284
FITEVT: A FORTRAN program for arrival-time analysis of nuclear-decay events
- 13 July 2020
- Published by American Physical Society (APS) in Physical Review C
- Vol. 102 (1) , 014310
-shell internal conversion coefficient for decay of the 30.8 keV isomer inThe 30.8 keV isomeric state in decays by an transition to the ground state. We have measured the -shell internal conversion coefficient for this transition in order to test the validity of current methods of calculation for a case with relatively low atomic number, low transition energy, and a high value of . Taking the fluorescence yield of niobium to be 0.751(4), we obtain , a result that agrees with the Dirac-Fock calculations that take into account the presence of a vacancy in the final state, and disagrees by 1.7 standard deviations with calculations that ignore the vacancy. We also determine the energy of the isomeric state to be 30.760(5) keV, a fourfold improvement in precision over the currently accepted value.- 13 July 2020
- Published by American Physical Society (APS) in Physical Review C
- Vol. 102 (1) , 014310
-shell internal conversion coefficient for decay of the 30.8 keV isomer inThe 30.8 keV isomeric state in decays by an transition to the ground state. We have measured the -shell internal conversion coefficient for this transition in order to test the validity of current methods of calculation for a case with relatively low atomic number, low transition energy, and a high value of . Taking the fluorescence yield of niobium to be 0.751(4), we obtain , a result that agrees with the Dirac-Fock calculations that take into account the presence of a vacancy in the final state, and disagrees by 1.7 standard deviations with calculations that ignore the vacancy. We also determine the energy of the isomeric state to be 30.760(5) keV, a fourfold improvement in precision over the currently accepted value.- 8 August 2013
- Published by American Physical Society (APS) in Physical Review A
- Vol. 88 (2) , 022703
Transverse momentum of ionized atoms and diatomic molecules acquired in collisions with fast highly charged heavy ions
Using a recoil-ion momentum spectrometer (RIMS), transverse momenta () of recoil atomic and molecular ions emerging from collisions between 2.5-MeV/u Xe projectiles and neutral Ne, Ar, CO, N, and O gases were measured as a function of the degree of target ionization. For the molecular targets the resulting distributions of corresponding to different dissociation channels were separated. Measurements with all the targets were performed under virtually identical conditions so that the results could be directly compared in detail. It was found that the shapes of the distributions are characterized by single asymmetric peaks and that, at least in the vicinity of their maximum values, they are well described by Weibull functions. Except for the Ar target, the velocities corresponding to the maxima of the distributions were found to follow (within the uncertainties of the results) a universal function of the target charge-to-mass number ratio for values up to 0.33. For larger charge-to-mass number ratios the results for the molecular targets appear to remain universal, but are slightly lower than the results for the Ne target. A more elaborate scaling was required to obtain a universal function that describes the low-charge-state results for Ne and Ar targets in a similar way. For different dissociation channels of the same parent molecular ion with charge states exceeding 6+, significant differences were found between the measured distributions. These differences were ascribed to increases in the ionization potential and to more prominent contributions from target-to-projectile electron transfer for the more asymmetric dissociation channels. For symmetric and nearly symmetric molecular dissociation channels the fragments with combined charge number exceeding 9 for N and 10 for O were found to be distributed with a reduced probability at angles close to 90° relative to the beam direction. The magnitude of this effect was found to depend on the number of electrons removed in addition to one half of the number of available electrons (–). On the other hand, for highly asymmetric dissociation channels the angular distributions seem to indicate that the fragments of highly charged molecular ions may be distributed with an enhanced probability at angles close to 90° relative to the beam direction. A slight dependence of the distribution on molecular orientation was found to be present for the symmetric and nearly symmetric dissociation channels having . The magnitude of this effect also seems to be determined by the value of –.- 8 August 2013
- Published by American Physical Society (APS) in Physical Review A
- Vol. 88 (2) , 022703
Transverse momentum of ionized atoms and diatomic molecules acquired in collisions with fast highly charged heavy ions
Using a recoil-ion momentum spectrometer (RIMS), transverse momenta () of recoil atomic and molecular ions emerging from collisions between 2.5-MeV/u Xe projectiles and neutral Ne, Ar, CO, N, and O gases were measured as a function of the degree of target ionization. For the molecular targets the resulting distributions of corresponding to different dissociation channels were separated. Measurements with all the targets were performed under virtually identical conditions so that the results could be directly compared in detail. It was found that the shapes of the distributions are characterized by single asymmetric peaks and that, at least in the vicinity of their maximum values, they are well described by Weibull functions. Except for the Ar target, the velocities corresponding to the maxima of the distributions were found to follow (within the uncertainties of the results) a universal function of the target charge-to-mass number ratio for values up to 0.33. For larger charge-to-mass number ratios the results for the molecular targets appear to remain universal, but are slightly lower than the results for the Ne target. A more elaborate scaling was required to obtain a universal function that describes the low-charge-state results for Ne and Ar targets in a similar way. For different dissociation channels of the same parent molecular ion with charge states exceeding 6+, significant differences were found between the measured distributions. These differences were ascribed to increases in the ionization potential and to more prominent contributions from target-to-projectile electron transfer for the more asymmetric dissociation channels. For symmetric and nearly symmetric molecular dissociation channels the fragments with combined charge number exceeding 9 for N and 10 for O were found to be distributed with a reduced probability at angles close to 90° relative to the beam direction. The magnitude of this effect was found to depend on the number of electrons removed in addition to one half of the number of available electrons (–). On the other hand, for highly asymmetric dissociation channels the angular distributions seem to indicate that the fragments of highly charged molecular ions may be distributed with an enhanced probability at angles close to 90° relative to the beam direction. A slight dependence of the distribution on molecular orientation was found to be present for the symmetric and nearly symmetric dissociation channels having . The magnitude of this effect also seems to be determined by the value of –.- 1 November 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 269 (21) , 2584-2592
3D momentum imaging of molecular dissociation induced by fast, heavy-ion collisions in the strong interaction regime
- 1 November 2011
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 269 (21) , 2584-2592
3D momentum imaging of molecular dissociation induced by fast, heavy-ion collisions in the strong interaction regime
- 22 January 2009
- Published by American Physical Society (APS) in Physical Review A
- Vol. 79 (1) , 012708
satellite and hypersatellite distributions of Ar excited in heavy-ion collisionsSpectra of x rays emitted from Ar gas at atmospheric pressure under bombardment by heavy ions (atomic number 6–79) were measured in high resolution using a curved crystal spectrometer. Values of the apparent average fraction of vacancies at the time of x-ray emission were determined from the observed satellite and hypersatellite intensity distributions. A systematic comparison of the values for the monatomic gas Ar with those obtained previously for a variety of solid targets provided a quantitative assessment of the role interatomic transitions play in the -vacancy transfer process that occurs prior to x-ray decay.- 22 January 2009
- Published by American Physical Society (APS) in Physical Review A
- Vol. 79 (1) , 012708
satellite and hypersatellite distributions of Ar excited in heavy-ion collisionsSpectra of x rays emitted from Ar gas at atmospheric pressure under bombardment by heavy ions (atomic number 6–79) were measured in high resolution using a curved crystal spectrometer. Values of the apparent average fraction of vacancies at the time of x-ray emission were determined from the observed satellite and hypersatellite intensity distributions. A systematic comparison of the values for the monatomic gas Ar with those obtained previously for a variety of solid targets provided a quantitative assessment of the role interatomic transitions play in the -vacancy transfer process that occurs prior to x-ray decay.- 3 December 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 78 (6) , 062702
x-ray satellite and hypersatellite spectra of vanadium metal and oxides excited in heavy-ion collisionsThe spectra of vanadium x rays excited in targets of vanadium metal, VO, , and by projectiles of Ne, Ar, Kr, Ag, and Ho have been measured with a curved-crystal spectrometer. The spectra were analyzed to extract the relative intensities and energies of satellites and hypersatellites emitted in the decay of states having single and double vacancies, respectively, plus additional vacancies in the shell ranging from zero to seven. The intensity distributions, energies, and hypersatellite to satellite intensity ratios were examined for chemical effects. The parameters of a “universal” scaling function were obtained for the description of x-ray hypersatellite intensity distributions excited by heavy-ion collisions in solid targets.- 3 December 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 78 (6) , 062702
x-ray satellite and hypersatellite spectra of vanadium metal and oxides excited in heavy-ion collisionsThe spectra of vanadium x rays excited in targets of vanadium metal, VO, , and by projectiles of Ne, Ar, Kr, Ag, and Ho have been measured with a curved-crystal spectrometer. The spectra were analyzed to extract the relative intensities and energies of satellites and hypersatellites emitted in the decay of states having single and double vacancies, respectively, plus additional vacancies in the shell ranging from zero to seven. The intensity distributions, energies, and hypersatellite to satellite intensity ratios were examined for chemical effects. The parameters of a “universal” scaling function were obtained for the description of x-ray hypersatellite intensity distributions excited by heavy-ion collisions in solid targets.- 28 March 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 77 (3) , 032724
Effects of multiple ionization on the spectra ofx rays excited in heavy-ion collisionsSpectra of x rays emitted from thick solid targets containing elements with atomic numbers ranging from 49 (In) to 67 (Ho) were measured in high resolution using a curved crystal spectrometer. The projectiles included heavy ions (Ne, Ar, Kr, and Xe) ranging in energy from 6 to . A scaling rule was established for the apparent average fraction of vacancies at the time of x-ray emission and the result was compared to one obtained previously for the apparent average fraction of vacancies at the time of x-ray emission. The apparent degree of -shell ionization at the time of x-ray emission was examined as a function of target atomic number (for Kr projectiles), projectile atomic number (for an target), and projectile energy.- 28 March 2008
- Published by American Physical Society (APS) in Physical Review A
- Vol. 77 (3) , 032724
Effects of multiple ionization on the spectra ofx rays excited in heavy-ion collisionsSpectra of x rays emitted from thick solid targets containing elements with atomic numbers ranging from 49 (In) to 67 (Ho) were measured in high resolution using a curved crystal spectrometer. The projectiles included heavy ions (Ne, Ar, Kr, and Xe) ranging in energy from 6 to . A scaling rule was established for the apparent average fraction of vacancies at the time of x-ray emission and the result was compared to one obtained previously for the apparent average fraction of vacancies at the time of x-ray emission. The apparent degree of -shell ionization at the time of x-ray emission was examined as a function of target atomic number (for Kr projectiles), projectile atomic number (for an target), and projectile energy.- 17 August 2006
- Published by American Physical Society (APS) in Physical Review A
- Vol. 74 (2) , 022718
Systematics ofx-ray satellite structureSpectra of x rays emitted from a variety of solid targets (atomic number ) under bombardment by fast heavy ions (atomic number ) at were measured in high resolution using a curved crystal spectrometer. The spectra were analyzed in order to examine the dependence of x-ray satellite structure on the Geometrical Model’s universal variable . Scaling rules were established for the apparent average -shell spectator vacancy fraction at the time of x-ray emission, the satellite peak centroids, and the satellite peak widths.- 17 August 2006
- Published by American Physical Society (APS) in Physical Review A
- Vol. 74 (2) , 022718
Systematics ofx-ray satellite structureSpectra of x rays emitted from a variety of solid targets (atomic number ) under bombardment by fast heavy ions (atomic number ) at were measured in high resolution using a curved crystal spectrometer. The spectra were analyzed in order to examine the dependence of x-ray satellite structure on the Geometrical Model’s universal variable . Scaling rules were established for the apparent average -shell spectator vacancy fraction at the time of x-ray emission, the satellite peak centroids, and the satellite peak widths.