Yusely Ruiz Gonzalez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yusely Ruiz Gonzalez has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Marlen Perez-Diaz
Automatic Department, Universidad Central “Marta Abreu” de las Villas, Santa Clara, Cuba
3 shared publications Guang Li
National Laboratory of Industrial Control Technology, Institute of Advanced Process Control, Zhejiang University, Hangzhou 310027, China
2 shared publications- María Matilde García Lorenzo
Universidad Central “Marta Abreu” de Las Villas
2 shared publications - Melisa Llody Fajardo
Automatic Department, Universidad Central “Marta Abreu” de las Villas, Santa Clara, Cuba
2 shared publications - Adlin López-Díaz
Universidad de La Frontera
1 shared publication - Alberto Taboada-Crispi
Universidad Central “Marta Abreu” de Las Villas, UCLV
1 shared publication
Latest Publications
- 1 August 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045059
Automated patient-derived noise power spectrum estimation in abdominal CT: a preliminary validation
Background. Established methods are available for measuring the noise power spectrum (NPS) in computed tomography (CT) by using uniform phantoms. However, in clinical practice, direct estimation of this metric from patient images is desirable for continuous image quality monitoring and protocol optimization. Methodology. An automated workflow was developed through the integration of liver segmentation with TotalSegmentator, optimized selection of square patches in potentially homogeneous regions using a greedy algorithm, and NPS computation employing the PyLinac library. CT images from five patients and one homogeneous phantom were analyzed using two reconstruction kernels (lung and standard). Validation was performed using Kullback–Leibler divergence ( D KL ) to compare the NPS distributions obtained from patients and phantoms under equivalent acquisition conditions. Results. NPS estimation from abdominal images was feasible. In nearly all paired comparisons (phantom versus patient under identical acquisition and reconstruction conditions), D KL values between normalized NPS distributions were below 0.05 , indicating strong agreement in the shape of the spatial noise distribution between the homogeneous phantom and clinical studies. Conclusion. An automated workflow for NPS estimation in the hepatic parenchyma is presented. The similarity between the characteristic NPS profile obtained from the patient images and that derived from a homogeneous phantom acquired under equivalent conditions was subsequently validated. These preliminary results support the potential integration of this metric as a complementary quantitative tool for CT quality control programs, directly on patient images.
- 1 August 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045059
Automated patient-derived noise power spectrum estimation in abdominal CT: a preliminary validation
Background. Established methods are available for measuring the noise power spectrum (NPS) in computed tomography (CT) by using uniform phantoms. However, in clinical practice, direct estimation of this metric from patient images is desirable for continuous image quality monitoring and protocol optimization. Methodology. An automated workflow was developed through the integration of liver segmentation with TotalSegmentator, optimized selection of square patches in potentially homogeneous regions using a greedy algorithm, and NPS computation employing the PyLinac library. CT images from five patients and one homogeneous phantom were analyzed using two reconstruction kernels (lung and standard). Validation was performed using Kullback–Leibler divergence ( D KL ) to compare the NPS distributions obtained from patients and phantoms under equivalent acquisition conditions. Results. NPS estimation from abdominal images was feasible. In nearly all paired comparisons (phantom versus patient under identical acquisition and reconstruction conditions), D KL values between normalized NPS distributions were below 0.05 , indicating strong agreement in the shape of the spatial noise distribution between the homogeneous phantom and clinical studies. Conclusion. An automated workflow for NPS estimation in the hepatic parenchyma is presented. The similarity between the characteristic NPS profile obtained from the patient images and that derived from a homogeneous phantom acquired under equivalent conditions was subsequently validated. These preliminary results support the potential integration of this metric as a complementary quantitative tool for CT quality control programs, directly on patient images.
- 7 November 2025
- Published by Springer Nature in Health and Technology
- Vol. 16 (1) , 127-135
Deep learning vs. machine learning in the detection of pulmonary nodules with chest X-rays
- 7 November 2025
- Published by Springer Nature in Health and Technology
- Vol. 16 (1) , 127-135
Deep learning vs. machine learning in the detection of pulmonary nodules with chest X-rays
- 16 October 2025
- Published by Springer Nature
- p. 308-319
Detection of Diabetic Foot Ulcers Using Deep Learning Models
- 16 October 2025
- Published by Springer Nature
- p. 308-319
Detection of Diabetic Foot Ulcers Using Deep Learning Models
- 16 October 2025
- Published by Springer Nature
- p. 272-283
FedSyncBN: BatchNorm Synchronization for Pulmonary Vascular Anomaly Detection in Heterogeneous Federated Learning
- 16 October 2025
- Published by Springer Nature
- p. 272-283
FedSyncBN: BatchNorm Synchronization for Pulmonary Vascular Anomaly Detection in Heterogeneous Federated Learning
- 30 April 2025
- Published by Springer Nature
- p. 340-353
Detection of Lung Nodules with Chest X-Ray and Machine Learning
- 30 April 2025
- Published by Springer Nature
- p. 340-353
Detection of Lung Nodules with Chest X-Ray and Machine Learning
- 4 November 2021
- Published by Springer Nature
- p. 290-299
Automatic Classification of Diabetic Foot Ulcers Using Computer Vision Techniques
- 4 November 2021
- Published by Springer Nature
- p. 290-299
Automatic Classification of Diabetic Foot Ulcers Using Computer Vision Techniques
- 22 October 2019
- Published by Springer Nature
- p. 306-315
Role of EMG Rectification for Corticomuscular and Intermuscular Coherence Estimation of Spinocerebellar Ataxia Type 2 (SCA2)
- 22 October 2019
- Published by Springer Nature
- p. 306-315
Role of EMG Rectification for Corticomuscular and Intermuscular Coherence Estimation of Spinocerebellar Ataxia Type 2 (SCA2)
- 1 October 2019
- Published by Springer Nature
- p. 361-366
Noise Reduction in Phase-Contrast Mammography Images with Synchrotron Radiation
- 1 October 2019
- Published by Springer Nature
- p. 361-366
Noise Reduction in Phase-Contrast Mammography Images with Synchrotron Radiation
- 20 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (2) , 181-188
Objective measurements of image quality in synchrotron radiation phase-contrast imaging versus digital mammography
Phase-contrast mammography with synchrotron radiation is an innovative X-ray imaging practice that improves the identification of breast lesions. Previous studies have proven the superiority of the mammography images taken in the phase-contrast modality using synchrotron radiation beams as compared with images taken in conventional mammography by subjective analyses. However, to our knowledge, no previous study has compared different acquisition systems in order to quantify this improvement by means of objective robust indicators. In this research, we intend to quantify the superiority of phase-contrast imaging by means of objective metrics of image quality. Images from the American College of Radiology Mammographic Accreditation Phantom were obtained at hospitals, in two digital mammography equipment and at the Elettra synchrotron radiation facility (Trieste, Italy), using free space propagation phase-contrast modality. Regions of interest were selected to analyze image quality at the fibers (phase object) and masses (area object) simulated on the phantom by means of the signal-to-noise ratio, the figure of merit, the contrast and the edge visibility. The image contrast and edge visibility were significantly higher at the phase-contrast modality as compared with digital mammography equipment. The figure of merit using phase-contrast modality was higher for the fibers and comparable for the masses. The results showed an improvement of the contrast and edge visibility in phase-contrast images. These improvements may be important in the detection of small lesions and details.
- 20 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (2) , 181-188
Objective measurements of image quality in synchrotron radiation phase-contrast imaging versus digital mammography
Phase-contrast mammography with synchrotron radiation is an innovative X-ray imaging practice that improves the identification of breast lesions. Previous studies have proven the superiority of the mammography images taken in the phase-contrast modality using synchrotron radiation beams as compared with images taken in conventional mammography by subjective analyses. However, to our knowledge, no previous study has compared different acquisition systems in order to quantify this improvement by means of objective robust indicators. In this research, we intend to quantify the superiority of phase-contrast imaging by means of objective metrics of image quality. Images from the American College of Radiology Mammographic Accreditation Phantom were obtained at hospitals, in two digital mammography equipment and at the Elettra synchrotron radiation facility (Trieste, Italy), using free space propagation phase-contrast modality. Regions of interest were selected to analyze image quality at the fibers (phase object) and masses (area object) simulated on the phantom by means of the signal-to-noise ratio, the figure of merit, the contrast and the edge visibility. The image contrast and edge visibility were significantly higher at the phase-contrast modality as compared with digital mammography equipment. The figure of merit using phase-contrast modality was higher for the fibers and comparable for the masses. The results showed an improvement of the contrast and edge visibility in phase-contrast images. These improvements may be important in the detection of small lesions and details.