Taigang He
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Taigang He has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Dudley John Pennell
National Heart and Lung Institute, Imperial College London
7 shared publications - David Nigel Firmin
Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, United Kingdom
5 shared publications - Gillian C. Smith
NIHR Cardiovascular Biomedical Research Unit, Royal Brompton and Harefield NHS Foundation Trust, London, UK
3 shared publications - Peter D. Gatehouse
Cardiovascular Magnetic Resonance Unit, Royal Brompton Hospital, London, United Kingdom
3 shared publications Gillian C. Smith
2 shared publications- John B. Porter
University College London, London, UK
2 shared publications
Latest Publications
- Open Access
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 40
Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan
- 1 December 2014
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 16 (1) , 40
Open AccessBiopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan
- Open Access
- 31 January 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (3) , 588-593
In vivo comparison of myocardial T1 with T2 and T2* in thalassaemia major
Purpose: To compare myocardial T1 against T2 and T2* in patients with thalassemia major (TM) for myocardial iron characterization.Materials and Methods: A total of 106 TM patients (29 ± 10 years; 58 males) were studied on a 1.5 Tesla scanner using dedicated T1, T2*, and T2 relaxometry sequences. A single mid‐ventricular short axis slice was acquired within a breath‐hold.Results: In patients with myocardial iron overload (T2* < 20 ms; n = 52), there were linear correlations between T2 and T2* (r = 0.82; P = 0.0), and between T1 and T2* (r = 0.83; P = 0.0). In patients with no myocardial iron (n = 54), T2* values were scattered with no significant correlation against T2 or T1. For all patients (n = 106) there was a strong linear correlation (r = 0.93; P = 0.0) between myocardial T1 and T2.Conclusion: In patients with iron overload, myocardial T2 and T1 are correlated with T2*. In patients with low or normal myocardial iron concentration, other factors become dominant in affecting T2* values as shown by scattered T2* data. Myocardial T1 correlates linearly with T2 measurements in all patients suggesting that these two relaxation parameters avoid extrinsic magnetic field inhomogeneity effects and may potentially provide improved myocardial tissue characterization. J. Magn. Reson. Imaging 2013;38:588–593. © 2013 Wiley Periodicals, Inc.
- 31 January 2013
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 38 (3) , 588-593
Open AccessIn vivo comparison of myocardial T1 with T2 and T2* in thalassaemia major
Purpose: To compare myocardial T1 against T2 and T2* in patients with thalassemia major (TM) for myocardial iron characterization.Materials and Methods: A total of 106 TM patients (29 ± 10 years; 58 males) were studied on a 1.5 Tesla scanner using dedicated T1, T2*, and T2 relaxometry sequences. A single mid‐ventricular short axis slice was acquired within a breath‐hold.Results: In patients with myocardial iron overload (T2* < 20 ms; n = 52), there were linear correlations between T2 and T2* (r = 0.82; P = 0.0), and between T1 and T2* (r = 0.83; P = 0.0). In patients with no myocardial iron (n = 54), T2* values were scattered with no significant correlation against T2 or T1. For all patients (n = 106) there was a strong linear correlation (r = 0.93; P = 0.0) between myocardial T1 and T2.Conclusion: In patients with iron overload, myocardial T2 and T1 are correlated with T2*. In patients with low or normal myocardial iron concentration, other factors become dominant in affecting T2* values as shown by scattered T2* data. Myocardial T1 correlates linearly with T2 measurements in all patients suggesting that these two relaxation parameters avoid extrinsic magnetic field inhomogeneity effects and may potentially provide improved myocardial tissue characterization. J. Magn. Reson. Imaging 2013;38:588–593. © 2013 Wiley Periodicals, Inc.
- Open Access
- 23 August 2012
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (2) , 479-483
Automated truncation method for myocardial T2* measurement in thalassemia
Purpose: To propose an automated truncation method for myocardial T2* measurement and evaluate this method on a large population of patients with iron loading in the heart and scanned at multiple magnetic resonance imaging (MRI) centers.Materials and Methods: A total of 550 thalassemia patients were scanned at 20 international centers using a variety of MR scanners (Siemens, Philips, or GE). A single mid‐ventricular short axis slice was imaged. All patient data were anonymized before the T2* were measured by expert observers using standard techniques. These same datasets were then retrospectively processed using the proposed automated truncation method by another independent observer and the resulting T2* measurements were compared with those of expert readings.Results: The T2* measurements using the automated method showed good agreement with those measured by expert observers using standard techniques (P = 0.95) with a low coefficient of variation (1.6%).Conclusion: This study demonstrates feasibility and good reproducibility of a new automated truncation method for myocardial T2* measurement. This approach simplifies the overall analysis and can be easily incorporated into T2* analysis software to facilitate further development of a fully automated myocardial tissue iron quantification. J. Magn. Reson. Imaging 2013;37:479–483.
- 23 August 2012
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 37 (2) , 479-483
Open AccessAutomated truncation method for myocardial T2* measurement in thalassemia
Purpose: To propose an automated truncation method for myocardial T2* measurement and evaluate this method on a large population of patients with iron loading in the heart and scanned at multiple magnetic resonance imaging (MRI) centers.Materials and Methods: A total of 550 thalassemia patients were scanned at 20 international centers using a variety of MR scanners (Siemens, Philips, or GE). A single mid‐ventricular short axis slice was imaged. All patient data were anonymized before the T2* were measured by expert observers using standard techniques. These same datasets were then retrospectively processed using the proposed automated truncation method by another independent observer and the resulting T2* measurements were compared with those of expert readings.Results: The T2* measurements using the automated method showed good agreement with those measured by expert observers using standard techniques (P = 0.95) with a low coefficient of variation (1.6%).Conclusion: This study demonstrates feasibility and good reproducibility of a new automated truncation method for myocardial T2* measurement. This approach simplifies the overall analysis and can be easily incorporated into T2* analysis software to facilitate further development of a fully automated myocardial tissue iron quantification. J. Magn. Reson. Imaging 2013;37:479–483.
- Open Access
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 21
Value of black blood T2* cardiovascular magnetic resonance
- 1 January 2011
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 13 (1) , 21
Open AccessValue of black blood T2* cardiovascular magnetic resonance
- Open Access
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 24
Right ventricular volumes and function in thalassemia major patients in the absence of myocardial iron overload
- 1 October 2010
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 12 (1) , 24
Open AccessRight ventricular volumes and function in thalassemia major patients in the absence of myocardial iron overload
- Open Access
- 18 December 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (3) , 501-506
On using T2 to assess extrinsic magnetic field inhomogeneity effects on T2* measurements in myocardial siderosis in thalassemia
Magnetic resonance T2* has been validated as a noninvasive means of assessing myocardial iron overload. However, the effect on myocardial T2* of factors such as shimming, variations in capillary geometry, and susceptibility in relation to the effects of iron has not been fully clarified. Since T2 is not affected by extrinsic magnetic field inhomogeneity and has different sensitivity to capillary geometry, investigation into the in vivo relationship between myocardial T2* and T2 measurements can shed light on this important issue. This study was performed in 136 thalassemia patients. The myocardial T2 and T2* thresholds for normality created identical no‐iron‐overload and iron‐overloaded patient groups. In the no‐iron group, there was no correlation between myocardial T2 and T2*. In the iron‐overloaded patients, there was a linear correlation (R2 = 0.89) between myocardial T2* and T2 measurements, which indicates that the iron deposition is the dominant factor in determining these two relaxation values in this scenario. Magn Reson Med, 2009.
- 18 December 2008
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 61 (3) , 501-506
Open AccessOn using T2 to assess extrinsic magnetic field inhomogeneity effects on T2* measurements in myocardial siderosis in thalassemia
Magnetic resonance T2* has been validated as a noninvasive means of assessing myocardial iron overload. However, the effect on myocardial T2* of factors such as shimming, variations in capillary geometry, and susceptibility in relation to the effects of iron has not been fully clarified. Since T2 is not affected by extrinsic magnetic field inhomogeneity and has different sensitivity to capillary geometry, investigation into the in vivo relationship between myocardial T2* and T2 measurements can shed light on this important issue. This study was performed in 136 thalassemia patients. The myocardial T2 and T2* thresholds for normality created identical no‐iron‐overload and iron‐overloaded patient groups. In the no‐iron group, there was no correlation between myocardial T2 and T2*. In the iron‐overloaded patients, there was a linear correlation (R2 = 0.89) between myocardial T2* and T2 measurements, which indicates that the iron deposition is the dominant factor in determining these two relaxation values in this scenario. Magn Reson Med, 2009.
- Open Access
- 18 March 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (4) , 354-359
Optimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance
Purpose: To determine how injection rate, cardiac function, and breathhold influence the arterial input function (AIF), in order to optimize the AIF in the clinical setting for quantitative myocardial perfusion cardiovascular magnetic resonance (CMR).Materials and Methods: Gd (0.1 mmol/kg) bolus was injected at 3, 5, or 7 mL/second in 35 patients. In each cardiac cycle during the first‐pass, a series of saturation recovery (SR) fast low‐angle shot (FLASH) low resolution images with exponentially increasing SR delay times were acquired. Signal intensity (SI) time measurements were made from a region of interest (ROI) drawn in the ascending aorta (AA). The calculation of short T1s and thus peak Gd concentration [Gd] was performed by fitting the mean ROI SI against SR delay times.Results: The mean peak [Gd] in the AA increased as injection rate increased from 3 mL/second (5.0 mM), to 5 mL/second (7.1 mM), to 7 mL/second (4 mM) (P < 0.0001). The peak [Gd] increased as the left ventricular stroke volume (LV SV) increased (P = 0.01). Breath holding was not found to influence peak [Gd].Conclusion: In this study, we found that a high injection rate has advantages over lower injection speeds, although the duration of the AIF was apparently not significantly shortened by faster injection. The choice of expiration or inspiration as breathhold did not have a significant influence upon the AIF. Poor cardiac function was associated with a lower peak [Gd], indicating that first pass perfusion measurements in these patients will be suboptimal. J. Magn. Reson. Imaging 2005;21:354–359.
- 18 March 2005
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (4) , 354-359
Open AccessOptimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance
Purpose: To determine how injection rate, cardiac function, and breathhold influence the arterial input function (AIF), in order to optimize the AIF in the clinical setting for quantitative myocardial perfusion cardiovascular magnetic resonance (CMR).Materials and Methods: Gd (0.1 mmol/kg) bolus was injected at 3, 5, or 7 mL/second in 35 patients. In each cardiac cycle during the first‐pass, a series of saturation recovery (SR) fast low‐angle shot (FLASH) low resolution images with exponentially increasing SR delay times were acquired. Signal intensity (SI) time measurements were made from a region of interest (ROI) drawn in the ascending aorta (AA). The calculation of short T1s and thus peak Gd concentration [Gd] was performed by fitting the mean ROI SI against SR delay times.Results: The mean peak [Gd] in the AA increased as injection rate increased from 3 mL/second (5.0 mM), to 5 mL/second (7.1 mM), to 7 mL/second (4 mM) (P < 0.0001). The peak [Gd] increased as the left ventricular stroke volume (LV SV) increased (P = 0.01). Breath holding was not found to influence peak [Gd].Conclusion: In this study, we found that a high injection rate has advantages over lower injection speeds, although the duration of the AIF was apparently not significantly shortened by faster injection. The choice of expiration or inspiration as breathhold did not have a significant influence upon the AIF. Poor cardiac function was associated with a lower peak [Gd], indicating that first pass perfusion measurements in these patients will be suboptimal. J. Magn. Reson. Imaging 2005;21:354–359.