Wolfram Lamadé
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wolfram Lamadé has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Christoph Ulmer
Robert-Bosch Hospital, Stuttgart, Germany
6 shared publicationsColin Friedrich
Robert-Bosch Hospital, Stuttgart, Germany
4 shared publicationsKlaus Peter Thon
Department of Surgery, Robert-Bosch-Krankenhaus, Stuttgart Germany
4 shared publicationsFabian Rieber
Robert-Bosch Hospital, Stuttgart, Germany
3 shared publicationsKai Matthes
Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
3 shared publicationsTarkan Basar
Department of Surgery, Robert-Bosch-Krankenhaus, Stuttgart Germany
3 shared publications
Latest Publications
- 7 July 2011
- Published by SAGE Publications in Surgical Innovation
- Vol. 18 (3) , 206-213
New Backstrap Vagus Electrode for Continuous Intraoperative Neuromonitoring in Thyroid Surgery
Introduction. Continuous intraoperative neuromonitoring (CIONM) via vagal nerve stimulation allows real-time surveillance of the recurrent laryngeal nerve during thyroid surgery. However, for effective CIONM, subtle changes in recurrent laryngeal nerve conductivity have to be detected. A newly developed stimulation electrode that provides stable nerve stimulation and safe application is presented. Methods. For electrode validation, current distribution was simulated with the finite element method. Mechanical characteristics were assessed through bench testing. Clinical evaluation was initiated with 11 thyroid surgeries. Results. Experimental and clinical results led to the development of a tripolar gold/polyimide electrode mounted onto a backstrap-shaped silicone body. It facilitated rapid electrode implantation and extraction (median implantation time 4 ± 19 seconds). Peak extraction force was 570 mN. Median supramaximal stimulation currents were 2.00 ± 0.95 mA and resulted in reliable electromyogram responses (median 3.1 ± 3.0 mV). No intraoperative electrode dislocations occurred, and no postoperative nerve palsy was observed. Conclusion. The new backstrap vagal stimulation electrode meets the requirements for reliable CIONM.
- 7 July 2011
- Published by SAGE Publications in Surgical Innovation
- Vol. 18 (3) , 206-213
New Backstrap Vagus Electrode for Continuous Intraoperative Neuromonitoring in Thyroid Surgery
Introduction. Continuous intraoperative neuromonitoring (CIONM) via vagal nerve stimulation allows real-time surveillance of the recurrent laryngeal nerve during thyroid surgery. However, for effective CIONM, subtle changes in recurrent laryngeal nerve conductivity have to be detected. A newly developed stimulation electrode that provides stable nerve stimulation and safe application is presented. Methods. For electrode validation, current distribution was simulated with the finite element method. Mechanical characteristics were assessed through bench testing. Clinical evaluation was initiated with 11 thyroid surgeries. Results. Experimental and clinical results led to the development of a tripolar gold/polyimide electrode mounted onto a backstrap-shaped silicone body. It facilitated rapid electrode implantation and extraction (median implantation time 4 ± 19 seconds). Peak extraction force was 570 mN. Median supramaximal stimulation currents were 2.00 ± 0.95 mA and resulted in reliable electromyogram responses (median 3.1 ± 3.0 mV). No intraoperative electrode dislocations occurred, and no postoperative nerve palsy was observed. Conclusion. The new backstrap vagal stimulation electrode meets the requirements for reliable CIONM.
- 1 June 2011
- Published by Springer Nature in Der Chirurg
- Vol. 82 (8) , 719-722
Snake-charmer-NOTES-Proktokolektomie beim Mann
Restricted ability of triangulation, a highly flexible intestine, as well as limited control and overview over the abdominal organs, complicated extensive abdominal interventions in the past. Thus, additional access sites were needed to allow sufficient interoperative control. The newly developed snake charmer NOTES-technique enables the reduction of accesses to the umbilicus and rectum. We report the first case of total proctocolectomy with ileoanal pouch formation in hybrid NOTES technique in a male patient.
- 1 June 2011
- Published by Springer Nature in Der Chirurg
- Vol. 82 (8) , 719-722
Snake-charmer-NOTES-Proktokolektomie beim Mann
Restricted ability of triangulation, a highly flexible intestine, as well as limited control and overview over the abdominal organs, complicated extensive abdominal interventions in the past. Thus, additional access sites were needed to allow sufficient interoperative control. The newly developed snake charmer NOTES-technique enables the reduction of accesses to the umbilicus and rectum. We report the first case of total proctocolectomy with ileoanal pouch formation in hybrid NOTES technique in a male patient.
- 2 April 2011
- Published by Springer Nature in Der Chirurg
- Vol. 82 (10) , 913-920
Signalstabilität als Grundvoraussetzung für kontinuierliches intraoperatives Neuromonitoring
Operationsbedingte Paresen des Nervus laryngeus recurrens (NLR) sind nach wie vor eine gefürchtete Komplikation bei Schilddrüsenoperationen. Das kontinuierliche intraoperative Neuromonitoring (CIONM) wurde daher mit dem Ziel entwickelt, eine effektive Echtzeitüberwachung des NLR über seinen gesamten anatomischen Verlauf zu gewährleisten und auch geringgradige Leitfähigkeitsänderungen zu erfassen. Grundvoraussetzung für die zuverlässige Interpretation des CIONM ist die Signalstabilität. In einer prospektiv randomisierten Pilotstudie an 24 Patienten, entsprechend 30 „nerves at risk“ (NaR), wurde eine neu entwickelte, saxophonförmige Vagusstimulationselektrode (16 NaR) mit einer kommerziell erhältlichen Elektrode (14 NaR) verglichen. Als systemkritische Eigenschaften wurden Applizierbarkeit, Anwendungssicherheit und Signalstabilität untersucht. Dazu wurden Elektrodenimplantationszeiten, Stimulationsstromstärken, EMG-Amplituden und Elektrodendislokationsraten analysiert. Die Saxophonelektrode erlaubte eine schnellere Platzierung sowie eine einfachere Extraktion als die zylindrische Elektrode. Akzidentelle Elektrodendislokationen traten bei Verwendung der zylindrischen Elektrode bis zu 8-mal pro Operation auf, während die Saxophonelektrode während der gesamten Studie nur 2-mal dislozierte. Die zur supramaximalen NLR-Stimulation notwendigen Stromstärken waren signifikant geringer unter Verwendung der Saxophonelektrode. Gleichzeitig wurden im Gegensatz zur zylindrischen Elektrode signifikant höhere, stabile EMG-Amplituden erreicht. Postoperative Rekurrensschädigungen traten im Rahmen der Studie nicht auf. Die für ein CIONM notwendige Signalstabilität konnte in unseren Untersuchungen nur durch Einsatz der Saxophonelektrode erreicht werden. Ein geschlossenes Design, wie bei der getesteten Saxophonelektrode mit isolierten Stimulationskontakten und definierten Stromeintrittspunkten am Nerven ist nach den vorliegenden Ergebnissen Grundvoraussetzung für ein kontinuierliches intraoperatives Neuromonitoring. Postoperative recurrent laryngeal nerve (RLN) palsy is a well-known and dreaded complication of thyroid surgery. Continuous intraoperative neuromonitoring (CIONM) has been developed in order to provide an effective real-time surveillance of the RLN to its full extent and to detect subtle changes in nerve conductivity. A key requirement for a reliable interpretation of CIONM is signal stability. In a prospective randomized controlled pilot study 24 patients corresponding to 30 nerves at risk (NaR) were included to compare a newly developed, flexible, saxophone-shaped backstrap electrode for vagal stimulation (16 NaR) to a commercially available CE-marked cylindrical and rigid electrode (14 NaR). Electrode applicability, safety and signal stability were analyzed by assessment of electrode implantation times, stimulation currents, EMG amplitudes and electrode displacement rates. Implantation and extraction was significantly faster and easier with the saxophone-shaped backstrap electrode. Accidental electrode displacement occurred up to eight times per operation when applying the cylindrical electrode, while a total of two displacements resulted using the backstrap electrode in this study. Stimulation currents necessary for supramaximal RLN stimulation were significantly lower using the newly developed electrode. At the same time, significantly greater stable EMG amplitudes resulted using the new saxophone-shaped electrode. No RLN palsy occurred during the study. According to the data, only the saxophone-shaped backstrap electrode provided the signal stability required for CIONM. The closed electrode geometry with isolated contacts for nerve stimulation and defined current entry provide the prerequisites required for reliable continuous intraoperative neuromonitoring.
- 2 April 2011
- Published by Springer Nature in Der Chirurg
- Vol. 82 (10) , 913-920
Signalstabilität als Grundvoraussetzung für kontinuierliches intraoperatives Neuromonitoring
Operationsbedingte Paresen des Nervus laryngeus recurrens (NLR) sind nach wie vor eine gefürchtete Komplikation bei Schilddrüsenoperationen. Das kontinuierliche intraoperative Neuromonitoring (CIONM) wurde daher mit dem Ziel entwickelt, eine effektive Echtzeitüberwachung des NLR über seinen gesamten anatomischen Verlauf zu gewährleisten und auch geringgradige Leitfähigkeitsänderungen zu erfassen. Grundvoraussetzung für die zuverlässige Interpretation des CIONM ist die Signalstabilität. In einer prospektiv randomisierten Pilotstudie an 24 Patienten, entsprechend 30 „nerves at risk“ (NaR), wurde eine neu entwickelte, saxophonförmige Vagusstimulationselektrode (16 NaR) mit einer kommerziell erhältlichen Elektrode (14 NaR) verglichen. Als systemkritische Eigenschaften wurden Applizierbarkeit, Anwendungssicherheit und Signalstabilität untersucht. Dazu wurden Elektrodenimplantationszeiten, Stimulationsstromstärken, EMG-Amplituden und Elektrodendislokationsraten analysiert. Die Saxophonelektrode erlaubte eine schnellere Platzierung sowie eine einfachere Extraktion als die zylindrische Elektrode. Akzidentelle Elektrodendislokationen traten bei Verwendung der zylindrischen Elektrode bis zu 8-mal pro Operation auf, während die Saxophonelektrode während der gesamten Studie nur 2-mal dislozierte. Die zur supramaximalen NLR-Stimulation notwendigen Stromstärken waren signifikant geringer unter Verwendung der Saxophonelektrode. Gleichzeitig wurden im Gegensatz zur zylindrischen Elektrode signifikant höhere, stabile EMG-Amplituden erreicht. Postoperative Rekurrensschädigungen traten im Rahmen der Studie nicht auf. Die für ein CIONM notwendige Signalstabilität konnte in unseren Untersuchungen nur durch Einsatz der Saxophonelektrode erreicht werden. Ein geschlossenes Design, wie bei der getesteten Saxophonelektrode mit isolierten Stimulationskontakten und definierten Stromeintrittspunkten am Nerven ist nach den vorliegenden Ergebnissen Grundvoraussetzung für ein kontinuierliches intraoperatives Neuromonitoring. Postoperative recurrent laryngeal nerve (RLN) palsy is a well-known and dreaded complication of thyroid surgery. Continuous intraoperative neuromonitoring (CIONM) has been developed in order to provide an effective real-time surveillance of the RLN to its full extent and to detect subtle changes in nerve conductivity. A key requirement for a reliable interpretation of CIONM is signal stability. In a prospective randomized controlled pilot study 24 patients corresponding to 30 nerves at risk (NaR) were included to compare a newly developed, flexible, saxophone-shaped backstrap electrode for vagal stimulation (16 NaR) to a commercially available CE-marked cylindrical and rigid electrode (14 NaR). Electrode applicability, safety and signal stability were analyzed by assessment of electrode implantation times, stimulation currents, EMG amplitudes and electrode displacement rates. Implantation and extraction was significantly faster and easier with the saxophone-shaped backstrap electrode. Accidental electrode displacement occurred up to eight times per operation when applying the cylindrical electrode, while a total of two displacements resulted using the backstrap electrode in this study. Stimulation currents necessary for supramaximal RLN stimulation were significantly lower using the newly developed electrode. At the same time, significantly greater stable EMG amplitudes resulted using the new saxophone-shaped electrode. No RLN palsy occurred during the study. According to the data, only the saxophone-shaped backstrap electrode provided the signal stability required for CIONM. The closed electrode geometry with isolated contacts for nerve stimulation and defined current entry provide the prerequisites required for reliable continuous intraoperative neuromonitoring.
- 3 February 2011
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 20 (5) , 257-262
Snake charmer NOTES - a two-luminal access for hybrid NOS operations
Despite recent advances in NOTES, NOS, SILS and related techniques, the feasibility of performing extensive surgery is still limited. Colon surgery usually requires additional access sites or complex technical means for triangulation and retraction. A method is presented that enables single-port colon surgery, supported by flexible colonoscopy. Single-port sigmoidectomy was performed in five cases on the porcine model. Flexible colonoscopy was used to manoeuvre the colon and expose its mesentery for dissection. The specimen was retrieved transrectally by invagination. Single-port sigmoidectomy supported by colonoscopy was feasible in all cases. The method provided a fixed framework, excellent organ guidance and exposition of the mesentery and enabled bowel-close mesocolic preparation. The access angle for preparation and visualisation could be altered during the procedure using the colonoscope. During autopsy on day 21, competent anastomotic healing with only rare interenteric adhesions was observed. One animal had a small preperitoneal abscess in the umbilical region while demonstrating completed skin healing. Flexible colonoscopy provided a fixed reference frame that enabled single-port preparation and dissection of the sigmoid colon. Under colonoscopic guidance, the access angle for dissection could be adapted according to the surgeon's needs. The procedures could be performed safely and effectively.
- 3 February 2011
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 20 (5) , 257-262
Snake charmer NOTES - a two-luminal access for hybrid NOS operations
Despite recent advances in NOTES, NOS, SILS and related techniques, the feasibility of performing extensive surgery is still limited. Colon surgery usually requires additional access sites or complex technical means for triangulation and retraction. A method is presented that enables single-port colon surgery, supported by flexible colonoscopy. Single-port sigmoidectomy was performed in five cases on the porcine model. Flexible colonoscopy was used to manoeuvre the colon and expose its mesentery for dissection. The specimen was retrieved transrectally by invagination. Single-port sigmoidectomy supported by colonoscopy was feasible in all cases. The method provided a fixed framework, excellent organ guidance and exposition of the mesentery and enabled bowel-close mesocolic preparation. The access angle for preparation and visualisation could be altered during the procedure using the colonoscope. During autopsy on day 21, competent anastomotic healing with only rare interenteric adhesions was observed. One animal had a small preperitoneal abscess in the umbilical region while demonstrating completed skin healing. Flexible colonoscopy provided a fixed reference frame that enabled single-port preparation and dissection of the sigmoid colon. Under colonoscopic guidance, the access angle for dissection could be adapted according to the surgeon's needs. The procedures could be performed safely and effectively.
- 24 November 2010
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 20 (4) , 247-252
Sashimi NOTES - extraction of bulky specimens in no-scar operations
A major obstacle in no-scar surgery is the extraction of large, bulky or rigid specimen. Thus, a method is needed that allows for extraction of large specimens without situs contamination in women and men. It should enable safe treatment of infectious or malignant disease while preserving pathologic workup. Five patients suffering from diverticulitis with expected bulky and rigid specimen were enrolled into this early series. Preparation was performed transumbilically in single-port technique. To prevent new scar formation, the incision was limited to the base of the umbilicus without extension onto the sound abdominal skin. A functionally and topologically extracorporeal compartment was created within the abdomen by introduction and insufflation of a tear-proof impermeable retrieval bag. The specimen was sliced in a controlled fashion inside the compartment along a pre-marked geometry. Controlled specimen dissection in a dedicated intraabdominal resection compartment was feasible. The dissected specimen could be retrieved through the 1.5 cm umbilical incision without spillage of material. The geometry of the extracted organ was reconstructed in detail allowing for uncompromised pathological workup. Extraction of bulky and rigid specimen is possible through natural orifices by the proposed controlled dissection method enabling the pathologist to reconstruct anatomical affiliation.
- 24 November 2010
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 20 (4) , 247-252
Sashimi NOTES - extraction of bulky specimens in no-scar operations
A major obstacle in no-scar surgery is the extraction of large, bulky or rigid specimen. Thus, a method is needed that allows for extraction of large specimens without situs contamination in women and men. It should enable safe treatment of infectious or malignant disease while preserving pathologic workup. Five patients suffering from diverticulitis with expected bulky and rigid specimen were enrolled into this early series. Preparation was performed transumbilically in single-port technique. To prevent new scar formation, the incision was limited to the base of the umbilicus without extension onto the sound abdominal skin. A functionally and topologically extracorporeal compartment was created within the abdomen by introduction and insufflation of a tear-proof impermeable retrieval bag. The specimen was sliced in a controlled fashion inside the compartment along a pre-marked geometry. Controlled specimen dissection in a dedicated intraabdominal resection compartment was feasible. The dissected specimen could be retrieved through the 1.5 cm umbilical incision without spillage of material. The geometry of the extracted organ was reconstructed in detail allowing for uncompromised pathological workup. Extraction of bulky and rigid specimen is possible through natural orifices by the proposed controlled dissection method enabling the pathologist to reconstruct anatomical affiliation.
- 4 July 2010
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 396 (3) , 331-336
Impact of body image on patients’ attitude towards conventional, minimal invasive, and natural orifice surgery
- 4 July 2010
- Published by Springer Nature in Langenbeck's Archives of Surgery
- Vol. 396 (3) , 331-336
Impact of body image on patients’ attitude towards conventional, minimal invasive, and natural orifice surgery
- 24 May 2010
- Published by SAGE Publications in Surgical Innovation
- Vol. 17 (2) , 164-169
Trilumenal Hybrid-NOS Proctocolectomy
Background. The authors hypothesized that by combining transumbilical, transvaginal, and transrectal accesses, complex bowel operations, including proctocolectomy with restorative jejunal pouch reconstruction, might be possible. Methods and Results. Out of a series of 30 natural orifice surgery (NOS) operations performed at the authors’ institution in the past 12 months, proctocolectomy with ileoanal pouch reconstruction was planned for 3 female patients (31 years, BMI = 30; 50 years, BMI = 31; 30 years, BMI = 21) with extensive disease of ulcerative colitis, and they were operated via a 3-lumenal NOS approach. The first 2 patients received a proctocolectomy with a J-pouch formation. A 3-stage procedure was planned for the third patient, and she received a total colectomy. The colonic specimen was retrieved through the anus obviating dilation of the vagina. The J-pouch was prepared through a horizontal 2-cm incision, which later served as the protective loop ileostomy site. Conclusion . Trilumenal NOS proctocolectomy is feasible and safe providing a solution to overcome the lack of triangulation using a single-lumen approach.
- 24 May 2010
- Published by SAGE Publications in Surgical Innovation
- Vol. 17 (2) , 164-169
Trilumenal Hybrid-NOS Proctocolectomy
Background. The authors hypothesized that by combining transumbilical, transvaginal, and transrectal accesses, complex bowel operations, including proctocolectomy with restorative jejunal pouch reconstruction, might be possible. Methods and Results. Out of a series of 30 natural orifice surgery (NOS) operations performed at the authors’ institution in the past 12 months, proctocolectomy with ileoanal pouch reconstruction was planned for 3 female patients (31 years, BMI = 30; 50 years, BMI = 31; 30 years, BMI = 21) with extensive disease of ulcerative colitis, and they were operated via a 3-lumenal NOS approach. The first 2 patients received a proctocolectomy with a J-pouch formation. A 3-stage procedure was planned for the third patient, and she received a total colectomy. The colonic specimen was retrieved through the anus obviating dilation of the vagina. The J-pouch was prepared through a horizontal 2-cm incision, which later served as the protective loop ileostomy site. Conclusion . Trilumenal NOS proctocolectomy is feasible and safe providing a solution to overcome the lack of triangulation using a single-lumen approach.
- 23 February 2010
- Published by SAGE Publications in Surgical Innovation
- Vol. 17 (1) , 28-35
Triluminal Hybrid NOS as a Novel Approach for Colonic Resection With Colorectal Anastomosis
Background: Minimal invasive surgery has led to a significant decrease in surgical trauma, pain, recovery time and improved cosmesis compared with open surgery. However, scar development and the risk of hot spots for infections and hernias are still present. Natural orifice surgery (NOS) promises to offer even further reduction in invasiveness and thus may lead to even faster recovery. The goal of this study was to establish a NOS colonic resection by using commercially available standard surgical instruments avoiding major abdominal incisions. Methods and Results: This article reports a new triluminal hybrid NOS approach for sigmoid and colonic resection (Tri-Port-NOS-SIG), established using rigid laparoscopic instruments through the umbilicus, the vagina, and the rectum, without any major abdominal incision. The specimen was retrieved through the anus avoiding dilatation of the vagina. In an early series of 5 patients the first patient was a 37-year-old woman with a 10-year history of recurrent diverticulitis. She recovered quickly and was discharged on postoperative day 2. She returned to sports activity on day 12 postoperatively and to her heavy-duty job on day 16. The following 4 patients also recovered well and were discharged on postoperative days 7 (2 patients), 8, and 11, respectively. One patient experienced a temporary, mild paresthesia of the left lower dorsal leg, most likely because of intraoperative positioning. No major complications occurred. Conclusion: Tri-Port-NOS-SIG offers a feasible scarless approach for abdominal resections using commercially available surgical instruments in experienced hands.
- 23 February 2010
- Published by SAGE Publications in Surgical Innovation
- Vol. 17 (1) , 28-35
Triluminal Hybrid NOS as a Novel Approach for Colonic Resection With Colorectal Anastomosis
Background: Minimal invasive surgery has led to a significant decrease in surgical trauma, pain, recovery time and improved cosmesis compared with open surgery. However, scar development and the risk of hot spots for infections and hernias are still present. Natural orifice surgery (NOS) promises to offer even further reduction in invasiveness and thus may lead to even faster recovery. The goal of this study was to establish a NOS colonic resection by using commercially available standard surgical instruments avoiding major abdominal incisions. Methods and Results: This article reports a new triluminal hybrid NOS approach for sigmoid and colonic resection (Tri-Port-NOS-SIG), established using rigid laparoscopic instruments through the umbilicus, the vagina, and the rectum, without any major abdominal incision. The specimen was retrieved through the anus avoiding dilatation of the vagina. In an early series of 5 patients the first patient was a 37-year-old woman with a 10-year history of recurrent diverticulitis. She recovered quickly and was discharged on postoperative day 2. She returned to sports activity on day 12 postoperatively and to her heavy-duty job on day 16. The following 4 patients also recovered well and were discharged on postoperative days 7 (2 patients), 8, and 11, respectively. One patient experienced a temporary, mild paresthesia of the left lower dorsal leg, most likely because of intraoperative positioning. No major complications occurred. Conclusion: Tri-Port-NOS-SIG offers a feasible scarless approach for abdominal resections using commercially available surgical instruments in experienced hands.
- 1 September 2008
- Published by Georg Thieme Verlag KG in Gastroenterologie up2date
- Vol. 4 (03) , 263-281
„NOTES” – Experimentelle Erfahrungen und klinische Perspektiven
Das Akronym „NOTES” steht für „natural orifice translumenal endoscopic surgery” und bedeutet endoskopisches Operieren in sterilen Körperhöhlen über natürliche Zugangswege. Tierexperimentell und mittlerweile auch in ersten klinischen Studien werden transgastrale sowie transvaginale und auch transrektale Zugänge und Techniken evaluiert. Ausgehend von der Entfernung infizierter Pankreasnekrosen wurden inzwischen Techniken für die Anlage von Anastomosen, die endoskopische Adaptation chirurgischer Anastomoseninsuffizienzen und für Organresektionen, wie Cholezystektomie, Apendektomie und Nephrektomie entwickelt. Erste klinische Anwendungen sind noch limitiert und werden in den meisten Fällen als „Hybrid-NOTES-Techniken” unter laparoskopischer Assistenz oder Kontrolle ausgeführt. Es ist davon auszugehen, dass vom Einsatz der Mikro- und Nanotechnologie wichtige Impulse ausgehen, von denen auch die flexible Endoskopie und die laparoskopische Chirurgie profitieren werden. Insbesondere für multimorbide alte Patienten oder stark Übergewichtige könnte NOTES aufgrund der geringeren Invasivität einen wesentlichen Fortschritt bedeuten. Wesentlich erscheint die schrittweise Einführung von NOTES, um nicht durch ein übereiltes Vorgehen unter Inkaufnahme u. U. schwerwiegender Komplikationen bei Routineeingriffen die gesamte Entwicklung in Frage zu stellen. In Deutschland wurde die „Initiativgruppe NOTES in Deutschland” gegründet, um eine interdisziplinäre Forschungsplattform zu schaffen und die klinische Einführung von NOTES zu begleiten.
- 1 September 2008
- Published by Georg Thieme Verlag KG in Gastroenterologie up2date
- Vol. 4 (03) , 263-281
„NOTES” – Experimentelle Erfahrungen und klinische Perspektiven
Das Akronym „NOTES” steht für „natural orifice translumenal endoscopic surgery” und bedeutet endoskopisches Operieren in sterilen Körperhöhlen über natürliche Zugangswege. Tierexperimentell und mittlerweile auch in ersten klinischen Studien werden transgastrale sowie transvaginale und auch transrektale Zugänge und Techniken evaluiert. Ausgehend von der Entfernung infizierter Pankreasnekrosen wurden inzwischen Techniken für die Anlage von Anastomosen, die endoskopische Adaptation chirurgischer Anastomoseninsuffizienzen und für Organresektionen, wie Cholezystektomie, Apendektomie und Nephrektomie entwickelt. Erste klinische Anwendungen sind noch limitiert und werden in den meisten Fällen als „Hybrid-NOTES-Techniken” unter laparoskopischer Assistenz oder Kontrolle ausgeführt. Es ist davon auszugehen, dass vom Einsatz der Mikro- und Nanotechnologie wichtige Impulse ausgehen, von denen auch die flexible Endoskopie und die laparoskopische Chirurgie profitieren werden. Insbesondere für multimorbide alte Patienten oder stark Übergewichtige könnte NOTES aufgrund der geringeren Invasivität einen wesentlichen Fortschritt bedeuten. Wesentlich erscheint die schrittweise Einführung von NOTES, um nicht durch ein übereiltes Vorgehen unter Inkaufnahme u. U. schwerwiegender Komplikationen bei Routineeingriffen die gesamte Entwicklung in Frage zu stellen. In Deutschland wurde die „Initiativgruppe NOTES in Deutschland” gegründet, um eine interdisziplinäre Forschungsplattform zu schaffen und die klinische Einführung von NOTES zu begleiten.
- 1 January 2007
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 16 (3) , 149-154
A new system for continuous recurrent laryngeal nerve monitoring
Existing nerve monitoring devices in thyroid surgery are ‐ except for one ‐ mainly intermittently working nerve identification tools. We present a new vagal electrode which allows true continuous monitoring of the recurrent laryngeal nerve (RLN). The electrode was designed as a tripolar hybrid cuff electrode consisting of polyimide, gold and platinum layers embedded in a flexible silicon cuff which can be opened at the long side for introducing the nerve. It is fully implantable and atraumatic. The evoked potentials are sensed by standard thyroid electrodes. Real‐time signal analysis and audio feedback are achieved by specially designed software. Homogeneous and stable signals were recorded throughout the operations. Thus real‐time computer‐based signal analysis was possible. Evoked potentials reached 300–900 mV. Mean time to place the cuff electrode was 5.5 min. The nerve was stimulated a mean of 63 min (range 55–99 min). No RLN lesions were detected postoperatively. The new vagal electrode was easy to handle and led to stable and reproducible signals. The stimulation current could be kept extremely low due to the special geometry of the electrode. It offers the possibility for uninterrupted, continuous laryngeal nerve monitoring in thyroid surgery. In an ongoing clinical trial its compatibility as an add‐on for existing nerve monitoring devices is being tested.
- 1 January 2007
- Published by Taylor & Francis in Minimally Invasive Therapy & Allied Technologies
- Vol. 16 (3) , 149-154
A new system for continuous recurrent laryngeal nerve monitoring
Existing nerve monitoring devices in thyroid surgery are ‐ except for one ‐ mainly intermittently working nerve identification tools. We present a new vagal electrode which allows true continuous monitoring of the recurrent laryngeal nerve (RLN). The electrode was designed as a tripolar hybrid cuff electrode consisting of polyimide, gold and platinum layers embedded in a flexible silicon cuff which can be opened at the long side for introducing the nerve. It is fully implantable and atraumatic. The evoked potentials are sensed by standard thyroid electrodes. Real‐time signal analysis and audio feedback are achieved by specially designed software. Homogeneous and stable signals were recorded throughout the operations. Thus real‐time computer‐based signal analysis was possible. Evoked potentials reached 300–900 mV. Mean time to place the cuff electrode was 5.5 min. The nerve was stimulated a mean of 63 min (range 55–99 min). No RLN lesions were detected postoperatively. The new vagal electrode was easy to handle and led to stable and reproducible signals. The stimulation current could be kept extremely low due to the special geometry of the electrode. It offers the possibility for uninterrupted, continuous laryngeal nerve monitoring in thyroid surgery. In an ongoing clinical trial its compatibility as an add‐on for existing nerve monitoring devices is being tested.