Jared L. Anderson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jared L. Anderson has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Qichao Zhao
Department of Chemistry, The University of Toledo, Toledo, Ohio 43606, USA
4 shared publicationsCheng Zhang
The University of Toledo
3 shared publications- Leandro Wang Hantao
Department of Analytical Chemistry, Institute of Chemistry, Universidade Estadual de Campinas (UNICAMP), Campinas 13083-862, SP, Brazil
3 shared publications Manishkumar D. Joshi
Department of Chemistry, School of Green Chemistry and Engineering, The University of Toledo, 2801W, Bancroft Street, MS 602, Toledo, OH 43606, USA
3 shared publications- Maria Jose Trujillo-Rodríguez
Laboratorio de Materiales para Análisis Químico (MAT4LL), Departamento de Química, Facultad de Ciencias, Universidad de La Laguna. Avda. Astrofísico Francisco Sánchez s/n, E-38200 La Laguna, Spain
3 shared publications - Verónica Pino
Laboratorio de Materiales para Análisis Químico (MAT4LL), Departamento de Química, Facultad de Ciencias, Universidad de La Laguna. Avda. Astrofísico Francisco Sánchez s/n, E-38200 La Laguna, Spain
3 shared publications
Latest Publications
- 1 January 2017
- Published by GN1 Sistemas e Publicacoes Ltd. in Scientia Chromatographica
- Vol. 9 (3) , 145-159
Ionic liquids in magnetic-assisted microextraction procedures: A step forward for faster and selective sample preparation
O Scientia Chromatographica é o primeiro e até o presente, único periódico da América Latina dedicado exclusivamente as Técnicas Cromatográficas e Relacionadas.
- 1 January 2017
- Published by GN1 Sistemas e Publicacoes Ltd. in Scientia Chromatographica
- Vol. 9 (3) , 145-159
Ionic liquids in magnetic-assisted microextraction procedures: A step forward for faster and selective sample preparation
O Scientia Chromatographica é o primeiro e até o presente, único periódico da América Latina dedicado exclusivamente as Técnicas Cromatográficas e Relacionadas.
- 30 April 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (16) , 4615-4627
Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography
Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL–1–1) or only in the crosslinker (PIL–0–1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L−1 for p-cresol when using the PIL–1–1 and down to 270 μg · L−1 when using the PIL–0–1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL–1–1 and PIL–0–1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L−1, as intra-day precision). Graphical Abstract
- 30 April 2015
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (16) , 4615-4627
Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography
Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL–1–1) or only in the crosslinker (PIL–0–1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L−1 for p-cresol when using the PIL–1–1 and down to 270 μg · L−1 when using the PIL–0–1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL–1–1 and PIL–0–1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L−1, as intra-day precision). Graphical Abstract
- 21 January 2015
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 27 (3) , 923-931
Synthetic Strategies for Tailoring the Physicochemical and Magnetic Properties of Hydrophobic Magnetic Ionic Liquids
- 21 January 2015
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 27 (3) , 923-931
Synthetic Strategies for Tailoring the Physicochemical and Magnetic Properties of Hydrophobic Magnetic Ionic Liquids
- 1 January 2015
- Published by Springer Nature
- p. 153-198
Ionic Liquids and Polymeric Ionic Liquids in Analytical Environmental Applications
- 1 January 2015
- Published by Springer Nature
- p. 153-198
Ionic Liquids and Polymeric Ionic Liquids in Analytical Environmental Applications
- 1 September 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 843, 18-26
Chemical immobilization of crosslinked polymeric ionic liquids on nitinol wires produces highly robust sorbent coatings for solid-phase microextraction
- 1 September 2014
- Published by Elsevier in Analytica Chimica Acta
- Vol. 843, 18-26
Chemical immobilization of crosslinked polymeric ionic liquids on nitinol wires produces highly robust sorbent coatings for solid-phase microextraction
- 1 May 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1344, 15-22
Polymeric ionic liquid bucky gels as sorbent coatings for solid-phase microextraction
- 1 May 2014
- Published by Elsevier in Journal of Chromatography A
- Vol. 1344, 15-22
Polymeric ionic liquid bucky gels as sorbent coatings for solid-phase microextraction
- 20 September 2013
- Published by Elsevier in Journal of Chromatography A
- Vol. 1308, 161-165
Using glucaminium-based ionic liquids for improving the separation of 2-aminopyrimidine-5-ylboronic acid and its pinacol ester by high performance liquid chromatography
- 20 September 2013
- Published by Elsevier in Journal of Chromatography A
- Vol. 1308, 161-165
Using glucaminium-based ionic liquids for improving the separation of 2-aminopyrimidine-5-ylboronic acid and its pinacol ester by high performance liquid chromatography