Douglas G. Fraser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Douglas G. Fraser has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- Mamas Andreas Mamas
Keele Cardiovascular Research Group, Centre for Prognosis Research, Institute for Primary Care and Health Sciences, Keele University, United Kingdom; National Institute for Health and Care Research (NIHR) Birmingham Biomedical Research Centre, Birmingham, United Kingdom
10 shared publications - Farzin Fath-Ordoubadi
Biomedical Research Centre, Central Manchester NHS Foundation Trust Manchester, UK
5 shared publications - Magdi El-Omar
Manchester Royal Infirmary, Manchester, UK
4 shared publications Samer Arnous
Manchester Heart Centre, Manchester Royal Infirmary, Manchester, UK
4 shared publications- Vasim Farooq
Manchester Heart Centre, Manchester Royal Infirmary, Central Manchester University Hospitals, Manchester, United Kingdom
4 shared publications - Bernard Clarke
Biomedical Research Centre, Central Manchester NHS Foundation Trust Manchester, UK
3 shared publications
Latest Publications
- Open Access
- 6 November 2017
- Published by BMJ in Open Heart
- Vol. 4 (2) , e000537
Longitudinal deformation bench testing using a coronary artery model: a new standard?
Objectives To compare susceptibility of five different stent platforms with longitudinal stent deformation (LSD) using a clinically relevant bench testing model simulating both short and long malapposed lengths. Background Recent data suggest that design modifications to the Promus Element stent which led to the Promus Premier stent has reduced susceptibility to LSD. However, susceptibility to LSD at long malapposed lengths has not been tested. Furthermore, the mechanisms behind susceptibility to LSD are as yet unclear. Methods The Omega, Integrity, Multilink 8, Biomatrixand Promus Premier stent platforms were tested. The Omega, Integrity and Multilink 8 platforms were used in place of their drug-eluting equivalents. 3.5 mm stents were deployed in a stepped tube with the distal portion fixed and the proximal test section exposed. The force required to compress stents by a fixed distance at different exposed lengths was compared. Symmetrical and point loading were used. Results The Promus Premier was longitudinally as strong as Multilink and Integrity at a short exposed length (4 mm) but weaker, in between Omega and the other platforms, at longer exposed lengths (12 mm). As previously noted, the Omega (Promus Element) platform was significantly weaker than the other stents and Biomatrix was the strongest stent. Conclusion Susceptibility to LSD varies depending on length of malapposed segment when tested using a clinically relevant model as in this study. The mechanisms behind the susceptibility are likely multifactorial, including connector number, strut thickness, connector alignment and ring orientation but remain to be elucidated.
- 6 November 2017
- Published by BMJ in Open Heart
- Vol. 4 (2) , e000537
Open AccessLongitudinal deformation bench testing using a coronary artery model: a new standard?
Objectives To compare susceptibility of five different stent platforms with longitudinal stent deformation (LSD) using a clinically relevant bench testing model simulating both short and long malapposed lengths. Background Recent data suggest that design modifications to the Promus Element stent which led to the Promus Premier stent has reduced susceptibility to LSD. However, susceptibility to LSD at long malapposed lengths has not been tested. Furthermore, the mechanisms behind susceptibility to LSD are as yet unclear. Methods The Omega, Integrity, Multilink 8, Biomatrixand Promus Premier stent platforms were tested. The Omega, Integrity and Multilink 8 platforms were used in place of their drug-eluting equivalents. 3.5 mm stents were deployed in a stepped tube with the distal portion fixed and the proximal test section exposed. The force required to compress stents by a fixed distance at different exposed lengths was compared. Symmetrical and point loading were used. Results The Promus Premier was longitudinally as strong as Multilink and Integrity at a short exposed length (4 mm) but weaker, in between Omega and the other platforms, at longer exposed lengths (12 mm). As previously noted, the Omega (Promus Element) platform was significantly weaker than the other stents and Biomatrix was the strongest stent. Conclusion Susceptibility to LSD varies depending on length of malapposed segment when tested using a clinically relevant model as in this study. The mechanisms behind the susceptibility are likely multifactorial, including connector number, strut thickness, connector alignment and ring orientation but remain to be elucidated.
- 1 April 2016
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 11 (14) , e1639-e1648
Forward and back aspiration during ST-elevation myocardial infarction: a feasibility study
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 April 2016
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 11 (14) , e1639-e1648
Forward and back aspiration during ST-elevation myocardial infarction: a feasibility study
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 22 May 2015
- Published by Springer Nature in Current Cardiology Reports
- Vol. 17 (6) , 1-6
Transradial Sheathless Approach for PCI
The lumen of the radial artery in many patients is smaller than the outer diameter of a 6F radial sheath frequently leading to procedural pain, trauma to the radial artery and contributing to radial occlusion. Chronically, neointima formation reduces luminal size further, limiting successful re-intervention in some patients. Sheathless guides are 1–2F sizes smaller than corresponding sheaths and so may potentially reduce radial artery trauma. Although not currently recommended for routine use, the 6.5F Asahi EauCath Sheathless guide has a lower profile than a 5F sheath and the same inner lumen as a 6F guide and has been shown to be especially useful for interventional procedures requiring 6F techniques in patients with small radial arteries. Similarly, the 7.5F Asahi EauCath has a lower profile than a 6F sheath and the same inner lumen as a 7F guide and is useful for procedures requiring a large bore guide catheter. Alternatives include the MediKit Works 5F sheathless system and long dilators designed to allow the sheathless introduction of conventional guides. The recently approved ‘Flip’ dilator is now available outside Japan; however, experience is currently limited.
- 22 May 2015
- Published by Springer Nature in Current Cardiology Reports
- Vol. 17 (6) , 1-6
Transradial Sheathless Approach for PCI
The lumen of the radial artery in many patients is smaller than the outer diameter of a 6F radial sheath frequently leading to procedural pain, trauma to the radial artery and contributing to radial occlusion. Chronically, neointima formation reduces luminal size further, limiting successful re-intervention in some patients. Sheathless guides are 1–2F sizes smaller than corresponding sheaths and so may potentially reduce radial artery trauma. Although not currently recommended for routine use, the 6.5F Asahi EauCath Sheathless guide has a lower profile than a 5F sheath and the same inner lumen as a 6F guide and has been shown to be especially useful for interventional procedures requiring 6F techniques in patients with small radial arteries. Similarly, the 7.5F Asahi EauCath has a lower profile than a 6F sheath and the same inner lumen as a 7F guide and is useful for procedures requiring a large bore guide catheter. Alternatives include the MediKit Works 5F sheathless system and long dilators designed to allow the sheathless introduction of conventional guides. The recently approved ‘Flip’ dilator is now available outside Japan; however, experience is currently limited.
- 1 March 2015
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (11) , e1
Serial optical coherence tomography of drug-eluting stent in-stent restenosis treated with the Absorb bioresorbable scaffold: an effective treatment?
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 March 2015
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (11) , e1
Serial optical coherence tomography of drug-eluting stent in-stent restenosis treated with the Absorb bioresorbable scaffold: an effective treatment?
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 October 2014
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (6) , 689-693
Thrombus capture by withdrawal of an open filter device: a useful treatment for large non-occlusive coronary thrombus
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 October 2014
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (6) , 689-693
Thrombus capture by withdrawal of an open filter device: a useful treatment for large non-occlusive coronary thrombus
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 August 2014
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (4) , 419-423
Lessons from acute and late scaffold failures in the ABSORB EXTEND trial: have we really learned them all?
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 August 2014
- Published by Europa Digital & Publishing in EuroIntervention
- Vol. 10 (4) , 419-423
Lessons from acute and late scaffold failures in the ABSORB EXTEND trial: have we really learned them all?
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)
- 1 February 2014
- Published by Elsevier in The Lancet
- Vol. 383, S20
Arterial access site practice and bleeding risk in relation to procedural outcomes after percutaneous coronary intervention
- 1 February 2014
- Published by Elsevier in The Lancet
- Vol. 383, S20
Arterial access site practice and bleeding risk in relation to procedural outcomes after percutaneous coronary intervention
- 1 September 2013
- Vol. 25 (9) , 455-9
Transradial intervention via large-bore guide catheters: a study of coronary bifurcation disease treatment using the crush technique.
Transradial access for coronary intervention significantly reduces vascular complications and may be associated with a reduced risk of major adverse cardiovascular events. However, the small caliber of the radial artery has been considered a limitation to performing complex coronary intervention. Fifty-three patients with true bifurcation disease, in whom a two-stent strategy was felt to be indicated, were scheduled to undergo crush stenting via the transradial approach. Procedural outcome was recorded and 6- and 18-month clinical follow-up was performed. Successful crush stenting via the radial artery was performed in 51/55 lesions (93%). Crush stenting was performed in 53 lesions overall and successful final kissing inflation was achieved in 51/53 (96%). There were no in-hospital or procedural complications. The overall rate of death, myocardial infarction, or target vessel revascularization was 9.8% at 18-month follow-up. Complex percutaneous coronary intervention requiring large-bore catheters can be performed successfully in a high proportion of patients via the transradial approach. Crush stenting, with a very high rate of final kissing inflation, was associated in this series with excellent procedural and medium-term outcomes.
- 1 September 2013
- Vol. 25 (9) , 455-9
Transradial intervention via large-bore guide catheters: a study of coronary bifurcation disease treatment using the crush technique.
Transradial access for coronary intervention significantly reduces vascular complications and may be associated with a reduced risk of major adverse cardiovascular events. However, the small caliber of the radial artery has been considered a limitation to performing complex coronary intervention. Fifty-three patients with true bifurcation disease, in whom a two-stent strategy was felt to be indicated, were scheduled to undergo crush stenting via the transradial approach. Procedural outcome was recorded and 6- and 18-month clinical follow-up was performed. Successful crush stenting via the radial artery was performed in 51/55 lesions (93%). Crush stenting was performed in 53 lesions overall and successful final kissing inflation was achieved in 51/53 (96%). There were no in-hospital or procedural complications. The overall rate of death, myocardial infarction, or target vessel revascularization was 9.8% at 18-month follow-up. Complex percutaneous coronary intervention requiring large-bore catheters can be performed successfully in a high proportion of patients via the transradial approach. Crush stenting, with a very high rate of final kissing inflation, was associated in this series with excellent procedural and medium-term outcomes.
- 1 September 2012
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 9 (5) , 449-451
How serious an adverse event is longitudinal stent deformation? Incidence and severity
- 1 September 2012
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 9 (5) , 449-451
How serious an adverse event is longitudinal stent deformation? Incidence and severity