Elif Erhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elif Erhan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Seyda Korkut Ozoner
Department of Environmental Engineering, Bulent Ecevit University, 67100, Zonguldak, Turkey
4 shared publications- Faruk Yilmaz
Department of Chemistry Gebze Institute of Technology 41400 Gebze Kocaeli Turkey
3 shared publications Ali Demirci
Department of Chemistry, Gebze Institute of Technology, 41400, Gebze, Kocaeli, Turkey
1 shared publicationAsuman Celik
Department of Chemistry, Gebze Institute of Technology, 41400 Gebze, Kocaeli, Turkey
1 shared publicationBulent Keskinler
Department of Environmental Engineering , Gebze Institute of Technology , Cayirova, Kocaeli, Turkey
1 shared publication- Bulent Keskinler
Department of Environmental Engineering, Gebze Technical University, Gebze Kocaeli 41400, Turkey
1 shared publication
Latest Publications
- 19 October 2012
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 88 (4) , 727-732
Electrochemical biosensor for detection of formaldehyde in rain water
- 19 October 2012
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 88 (4) , 727-732
Electrochemical biosensor for detection of formaldehyde in rain water
- Open Access
- 18 July 2011
- Published by IntechOpen
Enzyme based phenol biosensors
Authors: Seyda Korkut Ozoner, Elif Erhan and Faruk Yilmaz
- 18 July 2011
- Published by IntechOpen
Open AccessEnzyme based phenol biosensors
Authors: Seyda Korkut Ozoner, Elif Erhan and Faruk Yilmaz
- 24 June 2011
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 87 (1) , 95-104
Vinylferrocene copolymers based biosensors for phenol derivatives
BACKGROUND: Newly synthesized composite films of P(glycidyl methacrylate85‐co‐vinylferrocene15)/Poly(glutaraldehyde)/ Polypyrrole [P(GMA85‐co‐VFc15)/PGA/PPy] and Poly(3‐methylthienyl methacrylate85‐co‐vinylferrocene15)/Polypyrrole [P (MTM85‐co‐VFc15)/PPy] were used as matrices for tyrosinase based working electrodes. Direct covalent attachment of enzyme was carried out via the pendant epoxy groups of P(GMA85‐co‐VFc15) film, and the entrapment of enzyme was achieved for electrode containing P(MTM85‐co‐VFc15) film via electropolymerization of pyrrole in the presence of enzyme. The aim of the study is amperometric determination of various phenolics and investigation of the effect of interfacial interactions between enzyme and matrices on biosensor response.RESULTS: The lowest detection limit and the highest sensitivity for a P(GMA85‐co‐VFc15) based working electrode was found to be 0.113 µmol L−1 for 4‐methoxyphenol, 40 nA (µmol L−1)−1 for pyrocatechol, respectively. Results showed that sensitivities were at least 8500–55000 times higher than the results in previous P(GMA‐co‐VFc) related studies.CONCLUSION: Facilitated electron transfer was achieved by means of mediator incorporated in conductive composites of VFc based redox copolymers. The effect was greater when enzyme was covalently bonded via epoxy groups due to the proximity of enzyme, mediator and electrode surface. Results showed that a multifunctional surface was provided on electrodes since the suggested copolymers could mediate an electrochemical reaction, and the multifunctional surface was capable of coating with conductive PPy. Copyright © 2011 Society of Chemical Industry
- 24 June 2011
- Published by Wiley in Journal of Chemical Technology & Biotechnology
- Vol. 87 (1) , 95-104
Vinylferrocene copolymers based biosensors for phenol derivatives
BACKGROUND: Newly synthesized composite films of P(glycidyl methacrylate85‐co‐vinylferrocene15)/Poly(glutaraldehyde)/ Polypyrrole [P(GMA85‐co‐VFc15)/PGA/PPy] and Poly(3‐methylthienyl methacrylate85‐co‐vinylferrocene15)/Polypyrrole [P (MTM85‐co‐VFc15)/PPy] were used as matrices for tyrosinase based working electrodes. Direct covalent attachment of enzyme was carried out via the pendant epoxy groups of P(GMA85‐co‐VFc15) film, and the entrapment of enzyme was achieved for electrode containing P(MTM85‐co‐VFc15) film via electropolymerization of pyrrole in the presence of enzyme. The aim of the study is amperometric determination of various phenolics and investigation of the effect of interfacial interactions between enzyme and matrices on biosensor response.RESULTS: The lowest detection limit and the highest sensitivity for a P(GMA85‐co‐VFc15) based working electrode was found to be 0.113 µmol L−1 for 4‐methoxyphenol, 40 nA (µmol L−1)−1 for pyrocatechol, respectively. Results showed that sensitivities were at least 8500–55000 times higher than the results in previous P(GMA‐co‐VFc) related studies.CONCLUSION: Facilitated electron transfer was achieved by means of mediator incorporated in conductive composites of VFc based redox copolymers. The effect was greater when enzyme was covalently bonded via epoxy groups due to the proximity of enzyme, mediator and electrode surface. Results showed that a multifunctional surface was provided on electrodes since the suggested copolymers could mediate an electrochemical reaction, and the multifunctional surface was capable of coating with conductive PPy. Copyright © 2011 Society of Chemical Industry
- 10 November 2009
- Published by Taylor & Francis in Analytical Letters
- Vol. 42 (18) , 3058-3072
A Novel Poly(Glutaraldehyde-co-Pyrrole)/Horseradish Peroxidase Composite Film Electrode
A newly synthesized copolymer, Poly(glutaraldehyde-co-pyrrole) was used to immobilize horseradish peroxidase for the construction of an amperometric biosensor for detection of phenols in a flow injection system. Infrared spectra of Poly(glutaraldehyde-co-pyrrole) showed that the incorporation of aldehyde groups into the conductive polymeric backbone was achieved. The values were found to be in the range of 0.077–0.468 mM for p-benzoquinone and 0.112–0.709 mM for catechol, at various flow rates ranging between 0.25–6 mL/min. The sensitivities at various flow rates ranged between 100–200 nA/mM for catechol and 30–100 nA/mM for p-benzoquinone. The biosensor retained its initial activity for 1 month.
- 10 November 2009
- Published by Taylor & Francis in Analytical Letters
- Vol. 42 (18) , 3058-3072
A Novel Poly(Glutaraldehyde-co-Pyrrole)/Horseradish Peroxidase Composite Film Electrode
A newly synthesized copolymer, Poly(glutaraldehyde-co-pyrrole) was used to immobilize horseradish peroxidase for the construction of an amperometric biosensor for detection of phenols in a flow injection system. Infrared spectra of Poly(glutaraldehyde-co-pyrrole) showed that the incorporation of aldehyde groups into the conductive polymeric backbone was achieved. The values were found to be in the range of 0.077–0.468 mM for p-benzoquinone and 0.112–0.709 mM for catechol, at various flow rates ranging between 0.25–6 mL/min. The sensitivities at various flow rates ranged between 100–200 nA/mM for catechol and 30–100 nA/mM for p-benzoquinone. The biosensor retained its initial activity for 1 month.