MSMichael P. F. Sutcliffe

Michael P. F. Sutcliffe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael P. F. Sutcliffe has a total of 117 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimentally Calibrated Double-Layer Finite Element Modelling of Human Auricle Mechanical Behaviour Including Geometric Variation

    by Yunpeng Li, Manohar Bance, Michael P. F. Sutcliffe

    The human auricle is increasingly used as a mounting site for wearable ear devices, or earables, but computational models describing its mechanical behaviour remain limited. This work aims to develop a finite element (FE) framework for simulating the mechanical response of the auricle using experimental calibration, layered anatomy, and selected geometric variation. A baseline auricle mesh derived from computed tomography (CT) was processed into a two-layer model representing an outer skin/soft-tissue layer and an inner cartilage core, and additional auricle meshes from a public three-dimensional (3D) scan database were selected to represent geometric variation. Quasi-static pulling and dynamic release simulations were used to extract effective stiffness and first-mode natural frequency for comparison with previous volunteer measurements. A linear elastic model was unable to reproduce the full experimental stiffness-frequency range, whereas a first-order Ogden model improved the agreement with the experimental stiffness-frequency response but did not fully capture the highest-stiffness volunteer responses. Sensitivity analysis showed that the shear modulus was the dominant material parameter, with the skin layer having the strongest effect on the overall response. Geometric variation and cartilage thickness also changed the simulated mechanical behaviour under identical material parameters. These results provide an FE modelling framework which can be used to study auricle mechanics and to inform the design of motion-robust earable devices.

  • Open Access

    Hardness and compression-induced cracking of lithium nickel oxide (LNO) secondary particles in a Li-ion battery

    by Ashley M. Roach, George S. Phillips, Ashok S. Menon, Paolo Melgari, Beth I.J. Johnston, Clare P. Grey, Louis F.J. Piper, Michael P.F. Sutcliffe, Vikram S. Deshpande, Norman A. Fleck

  • Open Access

    Machine learning-assisted gait analysis for lameness detection in heterogeneous dog populations

    by Lyndie Mitchell, Matthew Scott, Kirsten Häusler, Chiara Adami, Michael Sutcliffe, Matthew Allen

  • Open Access

    Effect of Alumina Coating on Hardness of Polycrystalline Lithium Nickel Oxide (LNO) Particles

    by Ashley M. Roach, George Phillips, Ashok S. Menon, Paolo Melgari, Beth I. J. Johnston, Clare P. Grey, Louis Piper, Michael P. F. Sutcliffe, V.S. Deshpande, Norman Fleck

    A macro-indentation technique is used to measure the hardness of polycrystalline lithium nickel oxide (LNO) particles in the composite cathode of a Li ion battery. The LNO particles are prepared at selected states of delithiation and are either uncoated or coated with amorphous alumina by particle atomic layer deposition (P-ALD): the P-ALD alumina coating enhances the electrochemical performance of the LNO cathode particles. A Vickers pyramidal indenter is used to indent the LNO cathode layer on a soft metallic substrate; the LNO layer thickness is much less than the indent depth, and consequently the indentation pressure is dictated by the hardness of the substrate. The average contact hardness of the LNO particles against the pyramidal indenter exceeds that of the substrate and is calculated from the true area of contact of the LNO particles, as measured by a scanning electron microscope (SEM). Additionally, high-throughput 3D profiling of the deformed cathode surfaces by an optical microscope is used to measure the true area of contact between LNO particles and indenter; the two techniques give excellent agreement. The average contact hardness of LNO particles is independent of both indent depth and hardness of the substrate. The contact hardness of the polycrystalline LNO particles is also independent of the presence of the P-ALD coating. A contact hardness of 345 +/- 22 MPa is measured for uncycled polycrystalline LNO particles in the initial, lithiated state; this hardness approximately halves when the LNO is delithiated.

  • Perspective of Dental Implant-Supported Cantilever Crown in Atrophic Posterior Maxilla

    by Andrii Kondratiev, Michael Sutcliffe, Larysa Linetska, Igor Linetskiy, Vladyslav Demenko

  • Stress Analysis of Implant-Supported Three-Unit Fixed Bridge in Compromized Maxilla: A Finite Element Study

    by Vladyslav Demenko, Igor Linetskiy, Oleg Yefremov, Larysa Linetska, Michael Sutcliffe, Andrii Kondratiev

  • Open Access

    Finite element analysis confirms the optimal apex position in medial opening wedge high tibial osteotomy to avoid lateral hinge fracture

    by Humza T. Osmani, Radhika Gupta, Rosemary Earl, Stanisław Tomaszczyk, Tom Turmezei, Neil A. Segal, Michael Sutcliffe, Joel Melton

    Purpose: Lateral hinge fracture is a significant complication of medial opening wedge high tibial osteotomy. While fracture risk is closely associated with the osteotomy apex position, the optimum position remains variable within the literature. Our hypothesis is that stresses at the osteotomy apex predicted by finite element analysis can be used to identify an apex position which minimises intra and postoperative fracture risks.Methods: A finite element model was studied to investigate the effect of varying the hinge position on fracture risk and severity for a given bone geometry; variables analysed included stress, strain and micromotion levels. Nine further knee models were studied to assess the variability between patients' bone properties and examine the effect of apex location on strains.Results: Lateral hinge width and height significantly influence intra‐operative stress, strain, and fracture risk, while hinge width predominately determines postoperative stability. Wider hinges improve postoperative stability, but increase the likelihood of intra‐articular fractures. Aiming the apex at the fibular head height minimises strain. The osteotomy apex should be located such that the hinge width is equal to 13% of the medial‐lateral width to minimise apex stress and fracture risk while preserving sufficient bone at the hinge for stability. The height of the apex from the tibial plateau should maintain a minimum value of 16% of the medial‐lateral width to avoid intra‐articular fracture, with the apex below the fibula head if necessary. The size of the tibia does not alter the optimal location, making our findings applicable across all tibia sizes.Conclusions: Our study has investigated and verified a proposed optimal apex position, based upon fracture risk prediction and micromotion at the osteotomy apex. This is clinically useful due to the potential use of the apex point on preoperative 2D radiographs when planning surgery.Level of Evidence: Not applicable.


  • Efficiency of Miniplates Fixation in Mandibular Oblique Fractures

    by Andrii Kondratiev, Michael Sutcliffe, Vladislav Demenko, Igor Linetskiy, Oleg Yefremov, Larysa Linetska

    At present, the topic of traumatism of the maxillofacial region is topical and requires the search for contemporary biomechanical solutions. It is known that the problem of mandibular traumatism ranks first among all injuries of the maxillofacial region. Treatment of mechanically failured human mandible was considered as the example of its body fracture in accordance with European classification of maxillofacial trauma. This type of injury was chosen because of its widespread, statistically supported incidence. The treatment method was based on the use of osteosynthesis systems, widely used in the healthcare systems of Western European countries. The purpose of the study was in biomechanical support of existing clinical protocols for the osteosynthesis system elements application to ensure positive treatment prospects. Finite element analysis of acting deformations and displacements in the adjacent bone tissues was carried out for the case of reconstruction of the lower jaw damaged by an oblique fracture in its middle part (body) using two mini-plates in accordance with current clinical protocol. In our case, fracture was fixated with two 1.25 mm in thickness titanium mini-plates. Two types of mini-plates with lengths of 27 mm (long) and 20.5 mm (short) between the axes of the outer holes were analyzed. The results was revealed that osteosynthesis systems technology provides the conditions for the fixed mandible ridges healing under gentle functional loading due to safe micromotions which do not exceed 150 micrometer threshold of safe displacements (0.15 mm for long mini-plate 27×2.5×1.25 mm and 0.13 mm for short mini-plate 20.5×3.5×1.25mm). Also, the largest sliding distance in the fracture section are 0.11 mm for long mini-plate 27×2.5×1.25 mm and 0.06 mm for short mini-plate 27×2.5×1.25 mm. From this viewpoint, short mini-plate is recommended as preferable. However, care should be taken in transferring the results to the clinical situation. First of all, the wider range of possible bone fractures and their actual shapes with possible deviations from a flat contour should be taken into account. Also, more adequate simulation of the crack ridges interface should be provided to answer the question on micromotion data accuracy influencing the crack fixation and the success of the bone healing.