Yasushige Mori
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yasushige Mori has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Doris Segets
Institute for Energy and Materials Processes – Particle Science and Technology (EMPI‐PST) University of Duisburg‐Essen Duisburg Germany
2 shared publications So Komada
Department of Chemical Engineering and Materials Science, Doshisha University, 1-3 Tatara Miyakodani Kyotanabe, Kyoto 610-0321, Japan
2 shared publications- Wolfgang Peukert
Institute of Particle Technology (LFG), Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Cauerstraße 4, 91058 Erlangen, Germany
2 shared publications - Benjamin Butz
University of Siegen
1 shared publication Christian Lutz
Institute of Particle Technology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Cauerstr. 4, 91058 Erlangen, Germany
1 shared publication- Erdmann Spiecker
Institute of Micro- and Nanostructure Research & Center for Nanoanalysis and Electron Microscopy (CENEM), University of Erlangen-Nürnberg, Erlangen, Allemagne
1 shared publication
Latest Publications
- 16 February 2015
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 119 (8) , 4009-4022
Classification of Zinc Sulfide Quantum Dots by Size: Insights into the Particle Surface–Solvent Interaction of Colloids
- 16 February 2015
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry C
- Vol. 119 (8) , 4009-4022
Classification of Zinc Sulfide Quantum Dots by Size: Insights into the Particle Surface–Solvent Interaction of Colloids
- 15 March 2013
- Published by Elsevier in Journal of Power Sources
- Vol. 226, 94-100
Verification of necessity of one-dimensional titania nanoscale materials for dye-sensitized solar cells
- 15 March 2013
- Published by Elsevier in Journal of Power Sources
- Vol. 226, 94-100
Verification of necessity of one-dimensional titania nanoscale materials for dye-sensitized solar cells
- 14 March 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (4) , 1-13
Quantitative evaluation of size selective precipitation of Mn-doped ZnS quantum dots by size distributions calculated from UV/Vis absorbance spectra
- 14 March 2013
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 15 (4) , 1-13
Quantitative evaluation of size selective precipitation of Mn-doped ZnS quantum dots by size distributions calculated from UV/Vis absorbance spectra
- 1 December 2007
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 311 (1-3) , 61-66
Effect of surface hydrophobicity on interaction between particle and flat plate at final stage of wet coating process
- 1 December 2007
- Published by Elsevier in Colloids and Surfaces A: Physicochemical and Engineering Aspects
- Vol. 311 (1-3) , 61-66
Effect of surface hydrophobicity on interaction between particle and flat plate at final stage of wet coating process
- 22 August 2007
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 24 (2) , 91-96
Characterization of Reference Particles of Transparent Glass by Laser Diffraction Method
The validation of particle size analysis by laser diffraction (LD) method should be done using reference particles, whose size distribution is better to have a range over one decade of size, according to ISO 13320‐1. Two kinds of samples met this request, 1–10 μm and 10–100 μm samples, were distributed from the Association of Powder Process Industry and Engineering, Japan (APPIE).In this paper, the results of the round robin test of these two samples by LD method were reported together with the comparison of the size distributions measured by electrical sensing zone and scanning electron microscope methods. 1–10 μm sample was well dispersed in water without detergent, but a few drops of detergent sometimes needed for dispersing 10–100 μm sample. For 1–10 μm sample, the mean particle size by LD methods was slightly smaller than that by SEM method, and was agreed with each other results by seven different LD instruments. For 10–100 μm sample, the mean particle size by LD methods agree well with that by SEM method, but the discrepancy of one instrument in larger size range became larger than the results of other instruments.
- 22 August 2007
- Published by Wiley in Particle & Particle Systems Characterization
- Vol. 24 (2) , 91-96
Characterization of Reference Particles of Transparent Glass by Laser Diffraction Method
The validation of particle size analysis by laser diffraction (LD) method should be done using reference particles, whose size distribution is better to have a range over one decade of size, according to ISO 13320‐1. Two kinds of samples met this request, 1–10 μm and 10–100 μm samples, were distributed from the Association of Powder Process Industry and Engineering, Japan (APPIE).In this paper, the results of the round robin test of these two samples by LD method were reported together with the comparison of the size distributions measured by electrical sensing zone and scanning electron microscope methods. 1–10 μm sample was well dispersed in water without detergent, but a few drops of detergent sometimes needed for dispersing 10–100 μm sample. For 1–10 μm sample, the mean particle size by LD methods was slightly smaller than that by SEM method, and was agreed with each other results by seven different LD instruments. For 10–100 μm sample, the mean particle size by LD methods agree well with that by SEM method, but the discrepancy of one instrument in larger size range became larger than the results of other instruments.
- 1 January 2006
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 24 (1) , 97-103
Size Distribution of Gold Nanoparticles Used by Small Angle X-ray Scattering
The size distribution of gold nanoparticles was estimated based on the scattering intensity data obtained from small angle X-ray scattering (SAXS) and compared with the result of micrographs by transmission electron microscopy. The slope of the Guinier plot was used to estimate the mean size assuming a narrow particle size distribution. When the size distribution is narrow, the mean size can be easily obtained from slope of a Guinier plot of scattering data within 10% error. Additionally, assuming a lognormal size distribution, the size distribution and the mean size can be calculated using the experimental SAXS data in the fitting analysis. The histogram method, which utilizes the coefficient matrix of scattering intensity, was also applied to the estimation of the size distribution, and this method could be useful for a rough estimate of the size distribution.
- 1 January 2006
- Published by Taylor & Francis in Particulate Science and Technology
- Vol. 24 (1) , 97-103
Size Distribution of Gold Nanoparticles Used by Small Angle X-ray Scattering
The size distribution of gold nanoparticles was estimated based on the scattering intensity data obtained from small angle X-ray scattering (SAXS) and compared with the result of micrographs by transmission electron microscopy. The slope of the Guinier plot was used to estimate the mean size assuming a narrow particle size distribution. When the size distribution is narrow, the mean size can be easily obtained from slope of a Guinier plot of scattering data within 10% error. Additionally, assuming a lognormal size distribution, the size distribution and the mean size can be calculated using the experimental SAXS data in the fitting analysis. The histogram method, which utilizes the coefficient matrix of scattering intensity, was also applied to the estimation of the size distribution, and this method could be useful for a rough estimate of the size distribution.