EGEunice Teresinha Giampaolo

Eunice Teresinha Giampaolo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Eunice Teresinha Giampaolo has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 February 2016
      • Vol. 29  (1) , 15-9

    Effectiveness of chemical disinfection on biofilms of relined dentures: A randomized clinical trial.

    by Eduardo B Moffa, Fernanda E Izumida, Janaina H Jorge, Maria C M Mussi, Walter L Siqueira, Eunice T Giampaolo

    To evaluate the effect of disinfection with sodium perborate or chlorhexidine (when combined with brushing) on the removal of biofilm in relined dentures. Swabs were collected 48 hours after the relining procedure and at the follow-up time intervals of 7, 15, 30, 90, and 180 days. The dentures' surface roughness was measured at the same times. 45 subjects were randomly divided into three groups of 15 subjects each. The control group brushed with coconut soap and a soft toothbrush. The sodium perborate group followed the same procedure and also disinfected with sodium perborate solution for 5 minutes per day. The chlorhexidine group followed the control group procedure and disinfected with 2% chlorhexidine digluconate solution for 5 minutes per day. The number of colony forming units and the surface roughness were evaluated statistically by 2-way repeated-measure ANOVA (α = 0.05). The control group dentures exhibited similar levels of microbial cells throughout the experiment. However, after 15 days, no microbial growth was observed on the dentures for which either disinfection agent was used. There were no statistically significant differences in superficial roughness between the groups (P = 0.298). The disinfection agents used, combined with brushing, were able to remove the relined dentures' biofilm after 15 days of disinfection. Roughness was not a predominant factor in CFU reduction.


    • 1 June 2015
      • Vol. 28  (3) , 150-6

    Effects of short-term immersion and brushing with different denture cleansers on the roughness, hardness, and color of two types of acrylic resin.

    by Beatriz Helena Dias Panariello, Fernanda Emiko Izumida, Eduardo Buozi Moffa, Ana Claudia Pavarina, Janaina Habib Jorge, Eunice Teresinha Giampaolo

    To investigate the cumulative effects of brushing (B) or immersion (I), using different cleansing agents, on the surface roughness, hardness and color stability of a heat-polymerized denture resin, Lucitone 550 (L), and a hard chairside reline resin, Tokuyama Rebase Fast II (T). A total of 316 specimens (10 x 2 mm) were fabricated. The specimens (n = 9) were divided into brushing or immersion groups according to the following agents: dentifrice/distilled water (D), 1% sodium hypochlorite (NaOCl), Corega Tabs (Pb), 1% chlorhexidine gluconate (Chx), and 0.2% peracetic acid (Ac). Brushing and immersion were tested independently. Assays were performed after 1, 3, 21, 45 and 90 brushing cycles or immersion of 10 seconds each. Data were evaluated statistically by repeated measures ANOVA. Tukey's honestly significant difference (HSD) post-hoc test was used to determine differences between means (α = 0.05). For L there was no statistically significant difference in roughness, except a significant decrease in roughness by brushing with D. T showed a significant effect on the roughness after 90 immersions with Ac. Hardness values decreased for L when specimens were immersed or brushed in NaOCl and Pb. The hardness of T decreased with increases in the repetitions (immersion or brushing), regardless of the cleaning method. Values of color stability for L resin showed significant color change after brushing with and immersion in Ac and Pb. Brushing with D exhibited a higher incidence of color change. For T there were no significant differences between cleaning agents and repetitions in immersion. A color change was noted after three brushings with the Ac, Chx, and D. Brushing with dentifrice decreased roughness of L. Immersion in or brushing with NaOCl and Pb decreased the hardness of L. For T, hardness decreased with increases in immersions or brushing. Color changes after the immersion in or brushing with cleaning agents were clinically acceptable according to National Bureau of Standards parameters for both resins.


  • In vitroevaluation of adherence ofCandida albicans,Candida glabrata, andStreptococcus mutansto an acrylic resin modified by experimental coatings

    by Fernanda Emiko Izumida, Eduardo Buozi Moffa, Carlos Eduardo Vergani, Ana Lúcia Machado, Janaína Habib Jorge, Eunice Teresinha Giampaolo

    This study evaluated the effect of experimental coatings, containing zwitterion or hydrophilic monomers, on the adherence of Candida albicans, Candida glabrata, and Streptococcus mutans to an acrylic resin. Acrylic samples (smooth or rough surfaces) were left untreated (control) or coated with one of the following experimental coatings: 3-hydroxypropylmethacrylate (HP) or sulfobetaine methacrylate (S), at concentrations of 25, 30, or 35%. Half of the specimens were coated with saliva. The adhesion test was performed by incubating specimens in C. albicans, C. glabrata, and S. mutans suspensions at 37°C for 90 min. The number of adhered microorganisms was determined by metabolic activity (XTT) and by cell viability (CFU). All coated specimens exhibited lower absorbance and CFU values compared to control specimens. Saliva and roughness did not promote microorganism adherence. An XPS analysis confirmed the modification in the chemical composition of the coatings in the experimental samples. These experimental coatings significantly reduced the adherence of C. albicans, C. glabrata and S. mutans to acrylic resin.


  • Open Access

    Cell Membrane Integrity of Candida Albicans after Different Protocols of Microwave Irradiation

    by Nara Hellen Campanha, Janaina Habib Jorge, Eunice Teresinha Giampaolo, Caio Sergio Botta Martins de Oliveira, Lívia NordiDovigo, Danielle Cardoso G. Maia, Ana Cláudia Pavarina

    Purpose: To evaluate the ability of low time microwaveexposureto inactivate and damage cell membrane integrity of C. albicans. Materials and Methods: Two 200ml C. albicans suspensions were obtained. Sterile dentures were placed in a beaker containing Experimental (ES) or Control suspensions (CS). ES was microwaved at 650 W for 1, 2, 3, 4 or 5 min. Suspensions were optically counted using Methylene blue dye as indicative of membrane-damaged cells; spread on Agar Sabouraud dextrose (ASD) for viability assay; or spectrophotometrically measured at 550nm. Cell-free solutions were submitted to content analyses of protein (Bradford and Pyrogallol red methods); Ca++ (Cresolphthalein Complexone method); DNA (spectrophotometer measurements at 260nm) and K+ (selective electrode technique). Data were analyzed by Student-t test and linear regression (α=0.05). In addition, flowcytometry analysis of Candida cells in suspensionwas performed using propidium iodide. Results: All ES cells demonstrated cell membrane damage at 3, 4 and 5 min,viable cells were nonexistent at 3, 4 and 5 min ES ASD plates and optical density of ES and CS was not significantly differentfor all exposition times. ES cells released highcontents of protein, K+, Ca++ and DNA after 2 min exposition when compared to that of the CSs. Similar results were observed with flow cytometry analysiswith regard to the periodsof microwave exposure. Conclusions: Microwave irradiation inactivated C. albicansafter 3min and damaged cell membrane integrity after 2 min exposition.


  • Open Access

    Evaluation of the occlusion vertical dimension of complete dentures after microwave disinfection

    by Michael F. M. Basso, Eunice T. Giampaolo, Ana L. Machado, Ana C. Pavarina, Carlos E. Vergani

    doi: 10.1111/j.1741‐2358.2011.00567.xEvaluation of the occlusion vertical dimension of complete dentures after microwave disinfectionObjectives:  An increase in occlusal vertical dimension (OVD) after microwave disinfection may result in the need for adjustments in the complete dentures. This in vitro study evaluated the increase in OVD of maxillary complete dentures submitted to microwave disinfection protocols.Material and methods:  Thirty sets of complete dentures were evaluated as follows: Group 1–15 sets had the maxillary complete dentures submitted to microwave disinfection (650 W/3 min), once a week, for 4 weeks. Group 2–15 sets had the maxillary complete dentures submitted to microwave disinfection (650 W/3 min), three times a week, for 4 weeks. The vertical dimension was measured with a micrometre (in mm) before disinfection protocols (baseline readings) and after each week of disinfection. Data were analysed using Wilcoxon and Friedman tests (α = 0.05).Results:  For Group 1, no significant difference was found between the increases in OVD and zero, and no significant difference was found between the weeks. For Group 2, the increases in OVD were significantly greater than zero, and the Friedman test showed that weeks 3 and 4 had significantly greater changes than week 1 and that week 4 had significantly greater change than week 2.Conclusion:  Microwave disinfection only promoted significant increase in OVD in Group 2, in which the values increased progressively.


  • Effect of microwave disinfection on the surface roughness of three denture base resins after tooth brushing

    by Fernanda Emiko Izumida, Roberta Chuqui Ribeiro, Eunice Teresinha Giampaolo, Ana Lucia Machado, Ana Cláudia Pavarina, Carlos Eduardo Vergani

    This study investigated the effect of microwave disinfection on the roughness of three heat-polymerised acrylic resins after tooth brushing. Microwave disinfection has been recommended to reduce cross-contamination. However, this procedure may also influence the physical and mechanical properties of acrylic resins. Specimens (40 × 20 × 2 mm) of resins: Lucitone 550 (L), QC 20(QC) and Acron MC (A) were prepared and divided into four groups (n = 10): Control groups 1 (C1) and 2 (C2) - stored in water for 48 h or 7 days; Test groups 1 (MW2) and 2 (MW7) - stored in water for 48 h and disinfected (650 W for 6 min) daily for 2 or 7 days, respectively. After treatments, the specimens were placed in a tooth brushing machine at a rate of 60 reciprocal strokes per minute. The specimens were brushed with 20 000 strokes, which represent approximately 2 years of denture cleansing. The surface roughness (Ra) was evaluated before and after the tooth brushing. Data were analysed by two-way anova and Tukey Honestly Significant Difference (HSD) post hoc tests (α = 0.05). The data revealed significant changes between test groups for A and L resins. Comparison among resins revealed that for MW7, the roughness of A was significantly lower than that of L. After the seven microwave cycles, it could be seen that the roughness values of QC were significantly lower than those of L. The roughness of QC after brushing was not significantly affected by microwave disinfection. For A and L, seven microwave cycles resulted in increased roughness.


    • 1 July 2010
      • Vol. 23  (4) , 318-320

    Influence of Microwave Disinfection on the Linear Dimensional Stability of Complete Dentures: A Clinical Study

    by Michael Frederico Manzolli Basso, Eunice Teresinha Giampaolo, Carlos Eduardo Vergani, Ana Lucia Machado, Ana Claudia Pavarina, Marco Antonio Compagnoni

    This clinical study evaluated the effect of two microwave disinfection protocols at 650 W for 3 minutes (group 1, once a week; group 2, three times a week) on the linear dimensional stability of complete dentures. Measurements were taken across four reference points: before the first microwave disinfection (baseline) and after each week of disinfection. Furthermore, the dentures were monitored clinically. Group 2 showed significantly greater shrinkage than group 1 in all evaluated weeks. During clinical monitoring, no significant findings were observed. Even though dimensional changes occurred, the clinical evaluation did not yield any changes in either group. Int J Prosthodont 2010;23:318-320.


  • Influence of Microwave Disinfection on the Dimensional Stability of Denture Reline Polymers

    by Michael Frederico Manzolli Basso, Eunice Teresinha Giampaolo, Carlos Eduardo Vergani, Ana Lúcia Machado, Ana Cláudia Pavarina, Roberta Chuqui Ribeiro

    Purpose: The purpose of this study was to evaluate the effect of microwave disinfection (3 minutes at 650 W) on the dimensional stability of hard chairside reline resins (Kooliner, Tokuyama Rebase II, Ufi Gel hard, New Truliner) and one heat-polymerizing denture base resin (Lucitone 550). Materials and Methods: A split mold with reference points was used to make specimens (50.0-mm diameter, 0.5-mm thick) from each material, divided into five test groups (n = 8). The distances between the points on the mold were measured (gold standard), and compared with those obtained from the specimens after polymerization (baseline readings) after one, two, three, and four cycles of disinfection by microwave irradiation. Results: ANOVA and Tukey tests (alpha = 0.05) showed that Kooliner was significantly affected by all disinfection cycles (p < 0.05) when compared with baseline measurements. New Truliner resin was significantly affected by three and four cycles of microwave disinfection when compared with baseline measurements (p < 0.05). For Tokuyama Rebase II, Ufi Gel hard, and Lucitone 550, no significant dimensional changes were found. Conclusions: Microwave disinfection promoted shrinkage of Kooliner and New Truliner. The dimensional stability of Tokuyama Rebase II, Ufi Gel Hard, and Lucitone 550 was not affected by microwave disinfection.


    • 18 February 2010
      • Vol. 40  (10) , e93-100

    Effect of microwave postpolymerization treatment and of storage time in water on the cytotoxicity of denture base and reline acrylic resins.

    by Janaina Habib Jorge, Eunice Teresinha Giampaolo, Carlos Eduardo Vergani, Ana Cláudia Pavarina, Ana Lúcia Machado, Iracilda Zeppone Carlos

    To evaluate the effect of microwave postpolymerization heat treatment and water storage time on the cytotoxicity of denture base and reline acrylic resins. Sample disks of 6 acrylic resins were fabricated under aseptic conditions (Kooliner, GC; Tokuyama Rebase II, Tokuyama Dental; New Truliner, Bosworth; Acron MC, GC; Lucitone 550, Dentsply; QC 20, Dentsply). The denture base acrylic resin samples were stored in water for 24 and 48 hours at 37 degrees C. The fabricated samples were further subdivided into 2 groups: (1) samples without heat treatment and (2) samples treated in a microwave. The 3H-thymidine incorporation test was used to determine the cytotoxicity of the materials. The data were statistically analyzed using the incomplete 3-way ANOVA and Tukey HSD tests (P < .05). Microwave postpolymerization heat treatment improved the biocompatibility of Tokuyama Rebase II. Tokuyama Rebase II without heat treatment and Acron MC in both experimental groups were graded as slightly cytotoxic in the group without water storage. The other resins were graded as noncytotoxic. After 24 hours of immersion in water, all materials were graded as noncytotoxic. After water storage for 48 hours, Acron MC without heat treatment and QC 20 in both experimental groups were graded as slightly cytotoxic. Lucitone 550 was graded as noncytotoxic in all experimental groups. Microwave irradiation may be considered an alternative to reduce the cytotoxicity of Tokuyama Rebase II. Dental practitioners should choose Lucitone 550 processed with terminal boiling stage.