AMArmine G. Minasian

Armine G. Minasian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Armine G. Minasian has a total of 18 co-authors. Here are the top co-authors by number of shared publications:

  • Frank F. Willems

    Department of Cardiology, Rijnstate Hospital, Wagnerlaan 55, 6815 AD Arnhem, The Netherlands

    4 shared publications
  • Frank J.J. van Den Elshout

    Department of Pulmonary Diseases, Rijnstate Hospital, Wagnerlaan 55, 6815 AD Arnhem, The Netherlands

    4 shared publications
  • P.N. Richard Dekhuijzen

    Department of Pulmonary Diseases, Radboud University Nijmegen Medical Center, Geert Grooteplein-Zuid 10, 6525 GA Nijmegen, The Netherlands

    4 shared publications
  • Paul J.P.C. van Den Bergh

    Department of Cardiology, Rijnstate Hospital, Wagnerlaan 55, 6815 AD Arnhem, The Netherlands

    4 shared publications
  • Yvonne F. Heijdra

    Department of Pulmonary Diseases, Radboud University Nijmegen Medical Center, Geert Grooteplein-Zuid 10, 6525 GA Nijmegen, The Netherlands

    4 shared publications
  • Petra J.E. Vos

    3 shared publications

Latest Publications

  • Open Access

    Using the Lower Limit of Normal Instead of the Conventional Cutoff Values to Define Predictors of Pulmonary Function Impairment in Subjects With Chronic Heart Failure

    by Armine G Minasian, Frank Jj van Den Elshout, Pn Richard Dekhuijzen, Petra Je Vos, Frank F Willems, Paul Jpc van Den Bergh, Yvonne F Heijdra

    BACKGROUND: Using the newer lower limit of normal criterion instead of the conventional cutoff values to define pulmonary function abnormalities may result in different predictors of pulmonary function impairment in patients with heart failure. Therefore, we assessed predictors of pulmonary function impairment in subjects with chronic heart failure according to the lower limit of normal in comparison with conventional cutoff values. METHODS: In this prospective cross-sectional study, 164 chronic heart failure subjects (age 68 ± 10 y, 78% men, 88% New York Heart Association class I-II) with left ventricular ejection fraction 1 /FVC <0.7). RESULTS: The lower limit of normal criterion identified an extra independent predictor of diffusion impairment compared with the 80% predicted value; in addition to body mass index, pack-years, and alveolar volume, female sex also turned out to be an independent predictor. A smoking history of ≥10 pack-years was a significant predictor of diffusion impairment and airway obstruction using the lower limit of normal criterion but not using the conventional cutoff values. However, lowering the cutoff points of conventional criteria to match the more stringent lower limit of normal and thus avoid overdiagnosis of diffusion impairment and airway obstruction in the elderly produced similar results as the lower limit of normal. CONCLUSIONS: The lower limit of normal identifies more predictors of diffusion impairment and airway obstruction compared with conventional cutoff values in subjects with chronic heart failure with left ventricular systolic dysfunction. However, lowering the conventional cutoff points yielded similar results as the lower limit of normal. (ClinicalTrials.gov registration NCT01429376.)


  • Open Access

    Serial pulmonary function tests to diagnose COPD in chronic heart failure

    by Armine G Minasian, Frank Jj van Den Elshout, Pn Richard Dekhuijzen, Petra Je Vos, Frank F Willems, Paul Jpc van Den Bergh, Yvonne F Heijdra

    It is unknown whether serial pulmonary function tests are necessary for the correct diagnosis of chronic obstructive pulmonary disease (COPD) in patients with stable non-congested chronic heart failure (CHF). The aim of this study was to determine the prevalence of COPD in outpatients with stable CHF without pulmonary congestion using initial as well as confirmatory spirometry three months after treatment for COPD. Spirometry was performed in 187 outpatients with stable CHF without pulmonary congestion on chest radiograph who had a left ventricular ejection fraction < 40% (mean age 69 ± 10 years, 78% men). COPD was defined according to the Global Initiative for Chronic Obstructive Lung Disease guidelines. The diagnosis of COPD was confirmed three months after treatment with tiotropium in newly diagnosed COPD patients. Using a three month follow-up spirometry to confirm initial diagnosis of de novo COPD did not change COPD prevalence significantly: 32.6% initially versus 32.1% after three months of follow-up. Only 1 of 25 (4%) patients with newly diagnosed COPD was not reproducibly obstructed at follow-up. COPD was greatly under- (19%) and overdiagnosed (32%). Spirometry should be used under stable and euvolemic conditions to decrease the burden of undiagnosed or overdiagnosed COPD in patients with CHF. Under these conditions, a confirmatory spirometry is unnecessary, as it does not change a newly established diagnosis of COPD in the vast majority of patients with CHF. ClinicalTrials.gov Identifier NCT01429376 .


  • Pulmonary function impairment in patients with chronic heart failure: Lower limit of normal versus conventional cutoff values

    by Armine G. Minasian, Frank J.J. van Den Elshout, P.N. Richard Dekhuijzen, Petra J.E. Vos, Frank F. Willems, Paul J.P.C. van Den Bergh, Yvonne F. Heijdra


  • Reply to letter to the Editor

    by Armine G. Minasian, Frank J.J. van Den Elshout, P.N. Richard Dekhuijzen, Petra J.E. Vos, Frank F. Willems, Paul J.P.C. van Den Bergh, Yvonne F. Heijdra

  • COPD in chronic heart failure: Less common than previously thought?

    by Armine G. Minasian, Frank J.J. van Den Elshout, P.N. Richard Dekhuijzen, Petra J.E. Vos, Frank F. Willems, Paul J.P.C. van Den Bergh, Yvonne F. Heijdra


  • Bronchodilator responsiveness in patients with chronic heart failure

    by Armine G. Minasian, Frank J.J. van Den Elshout, P.N. Richard Dekhuijzen, Petra J.E. Vos, Frank F. Willems, Paul J.P.C. van Den Bergh, Yvonne F. Heijdra