Geneviève Grégoire
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Geneviève Grégoire has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Arlette Millas
4 shared publicationsMathieu Delannée
Department of Biomaterials, Faculty of Odontology, University Toulouse III, 31062 Toulouse, France
3 shared publicationsPatrick Sharrock
Medical and Spatial Imaging Laboratory, University Toulouse III, Ave. Pompidou, 81104, Castres, France
3 shared publicationsPhilippe Guignes
Department of Biomaterials, Faculty of Odontology, University Toulouse III, 3 chemin des maraîchers, 31062 Toulouse Cedex 4, France
3 shared publicationsBernadette Akon
2 shared publicationsFiras Dabsie
2 shared publications
Latest Publications
- Open Access
- 1 October 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (7) , 3711-3715
Fluid flow through dentin–self-etch resin interface during long term in vitro aging
- 1 October 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (7) , 3711-3715
Open AccessFluid flow through dentin–self-etch resin interface during long term in vitro aging
- 1 January 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (1) , 21-27
Depletion of water molecules during ethanol wet-bonding with etch and rinse dental adhesives
- 1 January 2013
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 33 (1) , 21-27
Depletion of water molecules during ethanol wet-bonding with etch and rinse dental adhesives
- 1 January 2011
- Published by Elsevier in Journal of Dentistry
- Vol. 39 (1) , 30-39
Solvent composition of one-step self-etch adhesives and dentine wettability
- 1 January 2011
- Published by Elsevier in Journal of Dentistry
- Vol. 39 (1) , 30-39
Solvent composition of one-step self-etch adhesives and dentine wettability
- 1 July 2010
- Published by Elsevier in Journal of Dentistry
- Vol. 38 (7) , 526-533
Water permeability, hybrid layer long-term integrity and reaction mechanism of a two-step adhesive system
- 1 July 2010
- Published by Elsevier in Journal of Dentistry
- Vol. 38 (7) , 526-533
Water permeability, hybrid layer long-term integrity and reaction mechanism of a two-step adhesive system
- 1 September 2009
- Published by Elsevier in Journal of Dentistry
- Vol. 37 (9) , 691-699
Effects of dentine moisture on the permeability of total-etch and one-step self-etch adhesives
- 1 September 2009
- Published by Elsevier in Journal of Dentistry
- Vol. 37 (9) , 691-699
Effects of dentine moisture on the permeability of total-etch and one-step self-etch adhesives
- 1 May 2007
- Published by Elsevier in Journal of Dentistry
- Vol. 35 (5) , 388-397
Evaluation of the enamel etching capacity of six contemporary self-etching adhesives
- 1 May 2007
- Published by Elsevier in Journal of Dentistry
- Vol. 35 (5) , 388-397
Evaluation of the enamel etching capacity of six contemporary self-etching adhesives
- 1 January 2006
- Published by Operative Dentistry in Operative Dentistry
- Vol. 31 (1) , 39-46
Use of Two Surface Analyzers to Evaluate the Surface Roughness of Four Esthetic Restorative Materials After Polishing
SUMMARY: This study had two aims: determine how well four esthetic restorative materials lent themselves to polishing and compare the results obtained using two different techniques for evaluating surface roughness. The four materials used were two composites modified by the addition of resin, Dyract AP (Dentsply) and Dyract Flow (Dentsply); one composite designed for posterior restorations, SureFil (Dentsply) and one universal micromatrix composite, Esthet-X (Dentsply). Five test pieces were made with each product by inserting the material into cylindrical molds and polymerizing it layer by layer. A single operator polished the specimens on the same day using the Enhance system (Dentsply) and two aluminum oxide pastes. The surfaces were studied successively by means of two surface analyzers: a high-resolution optical profilometer (Nanosurf 488, SAS Technology) and a mechanical profilometer (Mitutoyo Surftest-SV 402). These measurements gave the mean roughness of the surface (Ra). Ten zones were examined for each specimen, and the specimens were observed under an optical microscope (PMG3 inverted metallographic microscope) at 50× magnification. The qualitative and quantitative analyses of the results showed good surface states for all materials. However, the composites based on nano- and micro-filler technology gave the smoothest surfaces after polishing. A comparison of the values obtained with each method of observation showed that mechanical profilometry tended to show roughness caused by polishing, while optical profilometry brought out roughness due to the structure of the material itself.
- 1 January 2006
- Published by Operative Dentistry in Operative Dentistry
- Vol. 31 (1) , 39-46
Use of Two Surface Analyzers to Evaluate the Surface Roughness of Four Esthetic Restorative Materials After Polishing
SUMMARY: This study had two aims: determine how well four esthetic restorative materials lent themselves to polishing and compare the results obtained using two different techniques for evaluating surface roughness. The four materials used were two composites modified by the addition of resin, Dyract AP (Dentsply) and Dyract Flow (Dentsply); one composite designed for posterior restorations, SureFil (Dentsply) and one universal micromatrix composite, Esthet-X (Dentsply). Five test pieces were made with each product by inserting the material into cylindrical molds and polymerizing it layer by layer. A single operator polished the specimens on the same day using the Enhance system (Dentsply) and two aluminum oxide pastes. The surfaces were studied successively by means of two surface analyzers: a high-resolution optical profilometer (Nanosurf 488, SAS Technology) and a mechanical profilometer (Mitutoyo Surftest-SV 402). These measurements gave the mean roughness of the surface (Ra). Ten zones were examined for each specimen, and the specimens were observed under an optical microscope (PMG3 inverted metallographic microscope) at 50× magnification. The qualitative and quantitative analyses of the results showed good surface states for all materials. However, the composites based on nano- and micro-filler technology gave the smoothest surfaces after polishing. A comparison of the values obtained with each method of observation showed that mechanical profilometry tended to show roughness caused by polishing, while optical profilometry brought out roughness due to the structure of the material itself.
- 1 September 2005
- Vol. 30 (4) , 481-91
Microscopic evaluation of dentin interface obtained with 10 contemporary self-etching systems: correlation with their pH.
This study investigated micromorphological differences in the hybridized complex formed using 10 commercially available self-etch bonding systems. In addition, the influence of the pH of the primer of these adhesives was evaluated. The self-etching systems tested were AdheSE, Adper Prompt L-Pop, Clearfil SE Bond, Etch&Prime 3.0 (Degussa, Germany), Prime & Bond NT Non Rinse Conditioner (Dentsply, Konstanz, Germany), One-Up Bond F, OptiBond Solo Plus Self Etch, Prompt L-Pop and Xeno III. One hundred non-carious human third molars were used. The teeth were divided into two groups of 50 and prepared for evaluation by optical microscopy or scanning electron microscopy. The specimens in each group were further divided into 10 subgroups of five specimens each to evaluate the 10 bonding systems. The pH of the primers of the bonding systems was measured. The results demonstrated morphological differences at the interface, depending on adhesive composition. The differences mainly concerned thickness of the hybrid layer, the absence or presence of microscopic voids at the adhesive-composite interface and whether the dentinal tubuli were completely sealed. The pH was not the determining factor conditioning the action of the self-etching adhesives.
- 1 September 2005
- Vol. 30 (4) , 481-91
Microscopic evaluation of dentin interface obtained with 10 contemporary self-etching systems: correlation with their pH.
This study investigated micromorphological differences in the hybridized complex formed using 10 commercially available self-etch bonding systems. In addition, the influence of the pH of the primer of these adhesives was evaluated. The self-etching systems tested were AdheSE, Adper Prompt L-Pop, Clearfil SE Bond, Etch&Prime 3.0 (Degussa, Germany), Prime & Bond NT Non Rinse Conditioner (Dentsply, Konstanz, Germany), One-Up Bond F, OptiBond Solo Plus Self Etch, Prompt L-Pop and Xeno III. One hundred non-carious human third molars were used. The teeth were divided into two groups of 50 and prepared for evaluation by optical microscopy or scanning electron microscopy. The specimens in each group were further divided into 10 subgroups of five specimens each to evaluate the 10 bonding systems. The pH of the primers of the bonding systems was measured. The results demonstrated morphological differences at the interface, depending on adhesive composition. The differences mainly concerned thickness of the hybrid layer, the absence or presence of microscopic voids at the adhesive-composite interface and whether the dentinal tubuli were completely sealed. The pH was not the determining factor conditioning the action of the self-etching adhesives.
- 1 January 2005
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 93 (1) , 56-63
Effect of self-etching adhesives on dentin permeability in a fluid flow model
- 1 January 2005
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 93 (1) , 56-63
Effect of self-etching adhesives on dentin permeability in a fluid flow model
- 1 July 2003
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 90 (1) , 42-49
Dentin permeability: Self-etching and one-bottle dentin bonding systems
- 1 July 2003
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 90 (1) , 42-49
Dentin permeability: Self-etching and one-bottle dentin bonding systems