Mohammad Saeid Hosseini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohammad Saeid Hosseini has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Hosseini-Bandegharaei
Faculty of Chemistry, Semnan University, Semnan, Iran
6 shared publications Foroogh Belador
Department of Chemistry, Faculty of Science, University of Birjand, Birjand, I. R. Iran
4 shared publicationsFatemeh Abedi
Islamic Azad University
2 shared publicationsMojtaba Hosseini
Department of Chemistry, Faculty of Science , University of Birjand , Birjand, Iran
2 shared publications- Navid Hosseini
Department of Civil & Environmental Engineering, Amirkabir University of Technology, Tehran, Iran
2 shared publications Ali Akbar Bazrafshan
Department of Chemistry, University of Yasuj, Yasuj, Iran
1 shared publication
Latest Publications
- 19 April 2018
- Published by Taylor & Francis in Polycyclic Aromatic Compounds
- Vol. 40 (2) , 382-395
Investigation on Adsorption Behavior of Some Pollutant Aromatic Acids onto Kaolinite by Spectrofluorometric Method
Polycyclic aromatic hydrocarbons are one of the most hazardous pollutants which can be degraded to aromatic acids (AAs) in the environment. These compounds are the main cause of soil pollution because of their solubility in water. In this work, the adsorption of some aromatic acids onto acid-activated kaolinite was studied in a batch process. The effects of contact time, initial pH, and amount of kaolinite were investigated on the adsorption process. The AAs removal enhances by increasing the contact time to 60 min at pH 6. Among the Langmuir, Freundlich, and Temkin models, the experimental isotherm data corresponding to the adsorption of the AAs onto kaolinite indicate an excellent agreement with the Langmuir equations. Three kinetic models including the pseudo-first- and second-order equations and the Elovich equation were selected to investigate the adsorption process. Kinetic parameters, namely, rate constants, equilibrium adsorption capacities, and correlation coefficients, for each kinetic equation were calculated and discussed. The investigations showed that the adsorption of AAs onto kaolinite can be described by the pseudo-second-order equation.
- 19 April 2018
- Published by Taylor & Francis in Polycyclic Aromatic Compounds
- Vol. 40 (2) , 382-395
Investigation on Adsorption Behavior of Some Pollutant Aromatic Acids onto Kaolinite by Spectrofluorometric Method
Polycyclic aromatic hydrocarbons are one of the most hazardous pollutants which can be degraded to aromatic acids (AAs) in the environment. These compounds are the main cause of soil pollution because of their solubility in water. In this work, the adsorption of some aromatic acids onto acid-activated kaolinite was studied in a batch process. The effects of contact time, initial pH, and amount of kaolinite were investigated on the adsorption process. The AAs removal enhances by increasing the contact time to 60 min at pH 6. Among the Langmuir, Freundlich, and Temkin models, the experimental isotherm data corresponding to the adsorption of the AAs onto kaolinite indicate an excellent agreement with the Langmuir equations. Three kinetic models including the pseudo-first- and second-order equations and the Elovich equation were selected to investigate the adsorption process. Kinetic parameters, namely, rate constants, equilibrium adsorption capacities, and correlation coefficients, for each kinetic equation were calculated and discussed. The investigations showed that the adsorption of AAs onto kaolinite can be described by the pseudo-second-order equation.
- 8 August 2016
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 96 (10) , 945-958
Synthesis of L-tyrosine-capped ZnSe quantum dots and its application to hypochlorite determination in water
In this study, a new sensitised spectrofluorometric method was presented as a probe sensor for hypochlorite analysis in oral and tap water samples. By capping L-tyrosine (Tyr) on ZnSe nanoparticles, stable quantum dots (QDs) were obtained. In comparison with Tyr, the fluorescence (FL) emission of Tyr-capped ZnSe is enhanced and shifted to greater wavelength, which causes to enhance the sensitivity for the determination of hypochlorite. Based on the FL quenching of the Tyr-capped ZnSe QDs, hypochlorite concentration was detected at buffering pH of 7 in the range of 5.15 × 10−5‒2.57 × 10−2 g L−1. Relative standard deviation and detection limit were found to be 0.83% and 2.06 × 10−5 g L−1, respectively. In comparison with the other methods of hypochlorite determination, this method is simple, fast and inexpensive, with low sample volume consumption. It also exhibits a good selectivity.
- 8 August 2016
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 96 (10) , 945-958
Synthesis of L-tyrosine-capped ZnSe quantum dots and its application to hypochlorite determination in water
In this study, a new sensitised spectrofluorometric method was presented as a probe sensor for hypochlorite analysis in oral and tap water samples. By capping L-tyrosine (Tyr) on ZnSe nanoparticles, stable quantum dots (QDs) were obtained. In comparison with Tyr, the fluorescence (FL) emission of Tyr-capped ZnSe is enhanced and shifted to greater wavelength, which causes to enhance the sensitivity for the determination of hypochlorite. Based on the FL quenching of the Tyr-capped ZnSe QDs, hypochlorite concentration was detected at buffering pH of 7 in the range of 5.15 × 10−5‒2.57 × 10−2 g L−1. Relative standard deviation and detection limit were found to be 0.83% and 2.06 × 10−5 g L−1, respectively. In comparison with the other methods of hypochlorite determination, this method is simple, fast and inexpensive, with low sample volume consumption. It also exhibits a good selectivity.
- 18 February 2016
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 51 (8) , 1328-1335
A novel solvent-impregnated resin containing 3-hydroxy-2-naphthoic acid for stepwise extraction of Th(IV) and U(VI) over other coexistence ions
A new solvent-impregnated resin (SIR) was constructed using Amberlite XAD-2 and 3-hydroxy-2-naphthoic acid (3H2NA). The SIR was applied for stepwise extraction of Th(IV) and U(VI) from the coexistence ions dissolved in aqueous media at pHs of 3.0 and 7.0, respectively. The U(VI) and Th(IV) ions adsorbed on the minicolumn were consecutively eluted with 0.5 M and 4 M HCl solutions. They were then measured by Arsenazo III at their maximum absorption wavelengths. The characteristic parameters for the successful separation of these ions from the aqueous media were investigated. The SIR showed excellent reproducibility during the 800 subsequent extraction cycles.
- 18 February 2016
- Published by Taylor & Francis in Separation Science and Technology
- Vol. 51 (8) , 1328-1335
A novel solvent-impregnated resin containing 3-hydroxy-2-naphthoic acid for stepwise extraction of Th(IV) and U(VI) over other coexistence ions
A new solvent-impregnated resin (SIR) was constructed using Amberlite XAD-2 and 3-hydroxy-2-naphthoic acid (3H2NA). The SIR was applied for stepwise extraction of Th(IV) and U(VI) from the coexistence ions dissolved in aqueous media at pHs of 3.0 and 7.0, respectively. The U(VI) and Th(IV) ions adsorbed on the minicolumn were consecutively eluted with 0.5 M and 4 M HCl solutions. They were then measured by Arsenazo III at their maximum absorption wavelengths. The characteristic parameters for the successful separation of these ions from the aqueous media were investigated. The SIR showed excellent reproducibility during the 800 subsequent extraction cycles.
- 1 February 2016
- Published by Taylor & Francis in Synthesis and Reactivity in Inorganic, Metal-Organic, and Nano-Metal Chemistry
- Vol. 46 (6) , 950-957
Investigation on Structural, Optical, and Magnetic Properties of Dy-Doped-CeO2 Nanoparticles Synthesized by Microwave-Induced Combustion Method
In this work, new kinds of magnetic luminescent nanoparticles were synthesized by doping of Dy in CeO2 nanoparticles (DDC) with ratios of 5.2, 11.11 and 17.6 mol% via microwave-induced combustion method. The nanoparticles obtained were characterized by several techniques including X-ray diffraction, specific surface area measurements, scanning electron microscopy, transmission electron microscopy, UV–Vis absorption, fluorescence emission, IR, Raman spectroscopy, and vibrating sample magnetometry. It was observed that the average size of rod-shape nanoparticles with 11.11 mol% Dy is 16–20 nm and exhibits higher fluorescence emission and magnetic properties compared to the other samples.
- 1 February 2016
- Published by Taylor & Francis in Synthesis and Reactivity in Inorganic, Metal-Organic, and Nano-Metal Chemistry
- Vol. 46 (6) , 950-957
Investigation on Structural, Optical, and Magnetic Properties of Dy-Doped-CeO2 Nanoparticles Synthesized by Microwave-Induced Combustion Method
In this work, new kinds of magnetic luminescent nanoparticles were synthesized by doping of Dy in CeO2 nanoparticles (DDC) with ratios of 5.2, 11.11 and 17.6 mol% via microwave-induced combustion method. The nanoparticles obtained were characterized by several techniques including X-ray diffraction, specific surface area measurements, scanning electron microscopy, transmission electron microscopy, UV–Vis absorption, fluorescence emission, IR, Raman spectroscopy, and vibrating sample magnetometry. It was observed that the average size of rod-shape nanoparticles with 11.11 mol% Dy is 16–20 nm and exhibits higher fluorescence emission and magnetic properties compared to the other samples.
- 29 January 2016
- Published by Springer Nature in Journal of Fluorescence
- Vol. 26 (3) , 867-874
Synthesis of 2-Mercaptonicotinic Acid-Capped CdSe Quantum Dots and its Application to Spectrofluorometric Determination of Cr(VI) in Water Samples
The CdSe quantum dots (QDs) capped with 2-mercaptonicotinic acid (H2MN) were prepared through a controllable process at 80 °C. The prepared QDs were characterized by XRD, TEM, IR, UV–Vis and fluorescence (FL) techniques. It was found that the QDs were nearly mono-disperse with the diameters in the range of 8–10 nm. These QDs are capable to exhibit strong FL even in concentrated acidic media. They exhibit an enhanced fluorescence in the presence of Cr(VI), which was used for the determination of Cr(VI) in water samples. The linear range was found to be 1 × 10−7–6.0 × 10−6 M with the RSD and DL of 0.92 % and 5 × 10−8 M, respectively. Except that Ca2+ and Fe3+ which can be eliminated through a simple precipitation process, the other co-existent ions present in natural water were not interfered. The recoveries obtained for the added amounts of Cr(VI) were in the range of 96.9–103.2 %, which denote on application of the method, satisfactorily.
- 29 January 2016
- Published by Springer Nature in Journal of Fluorescence
- Vol. 26 (3) , 867-874
Synthesis of 2-Mercaptonicotinic Acid-Capped CdSe Quantum Dots and its Application to Spectrofluorometric Determination of Cr(VI) in Water Samples
The CdSe quantum dots (QDs) capped with 2-mercaptonicotinic acid (H2MN) were prepared through a controllable process at 80 °C. The prepared QDs were characterized by XRD, TEM, IR, UV–Vis and fluorescence (FL) techniques. It was found that the QDs were nearly mono-disperse with the diameters in the range of 8–10 nm. These QDs are capable to exhibit strong FL even in concentrated acidic media. They exhibit an enhanced fluorescence in the presence of Cr(VI), which was used for the determination of Cr(VI) in water samples. The linear range was found to be 1 × 10−7–6.0 × 10−6 M with the RSD and DL of 0.92 % and 5 × 10−8 M, respectively. Except that Ca2+ and Fe3+ which can be eliminated through a simple precipitation process, the other co-existent ions present in natural water were not interfered. The recoveries obtained for the added amounts of Cr(VI) were in the range of 96.9–103.2 %, which denote on application of the method, satisfactorily.
- 1 November 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 303 (3) , 2173-2183
Comparison of adsorption behavior of Th(IV) and U(VI) on mixed-ligands impregnated resin containing antraquinones with that conventional one
- 1 November 2014
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 303 (3) , 2173-2183
Comparison of adsorption behavior of Th(IV) and U(VI) on mixed-ligands impregnated resin containing antraquinones with that conventional one
- 16 July 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (19) , 5007-5013
A novel spectrofluorometric method for the determination of arsenic in human hair using Dy2O3-doped CeO2nanoparticles
This paper describes a simple and inexpensive method for the determination of arsenic in human hair samples based on spectrofluorometric detection. The applied Dy2O3-doped CeO2 (DDC) nanoparticles were synthesized using microwave-induced combustion technique and subjected to analytical samples containing As(V) species. At optimum conditions (pH 6, DDC concentration 3 mg L−1 and excitation/emission wavelengths 250 nm/352 nm), the fluorescence emission of DDC nanoparticles was diminished by increasing the As(V) concentration present in the medium. The co-existent ions present in hair were not interfered. A method for the speciation of As(III) and As(V) is also described. The method was validated using a well-known separation/spectrofluorometric method. There was no significant difference at the 95% confidence level between the results of the two methods. The proposed method is characterized by a wide analytical concentration range (5.0 × 10−8–1.0 × 10−5 M), a detection limit for As(V) of 1 × 10−8 mol L−1 and relative standard deviation of 1.4%. The recoveries for the spiked amounts of As(V) was found to be 93.3–104.0%.
- 16 July 2014
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 139 (19) , 5007-5013
A novel spectrofluorometric method for the determination of arsenic in human hair using Dy2O3-doped CeO2nanoparticles
This paper describes a simple and inexpensive method for the determination of arsenic in human hair samples based on spectrofluorometric detection. The applied Dy2O3-doped CeO2 (DDC) nanoparticles were synthesized using microwave-induced combustion technique and subjected to analytical samples containing As(V) species. At optimum conditions (pH 6, DDC concentration 3 mg L−1 and excitation/emission wavelengths 250 nm/352 nm), the fluorescence emission of DDC nanoparticles was diminished by increasing the As(V) concentration present in the medium. The co-existent ions present in hair were not interfered. A method for the speciation of As(III) and As(V) is also described. The method was validated using a well-known separation/spectrofluorometric method. There was no significant difference at the 95% confidence level between the results of the two methods. The proposed method is characterized by a wide analytical concentration range (5.0 × 10−8–1.0 × 10−5 M), a detection limit for As(V) of 1 × 10−8 mol L−1 and relative standard deviation of 1.4%. The recoveries for the spiked amounts of As(V) was found to be 93.3–104.0%.
- 22 April 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 7 (10) , 2145-2152
Spectrofluorometric Method for Determination of Al3+ with 3-Hydroxy-2-Naphthalenecarboxylic Acid and its Application to Milk Samples
- 22 April 2014
- Published by Springer Nature in Food Analytical Methods
- Vol. 7 (10) , 2145-2152
Spectrofluorometric Method for Determination of Al3+ with 3-Hydroxy-2-Naphthalenecarboxylic Acid and its Application to Milk Samples
- 14 January 2014
- Published by Wiley in Luminescence
- Vol. 29 (7) , 798-804
Study of fluorescence quenching of mercaptosuccinic acid‐capped CdS quantum dots in the presence of some heavy metal ions and its application to Hg(II) ion determination
In this study, CdS quantum dots (QDs) capped with mercaptosuccinic acid (MSA) were prepared in one step. The size, shape, component and spectral properties of MSA‐capped CdS QDs were characterized by transmission electron microscopy (TEM), photoluminescence (PL) and infrared (IR) spectrometry. The results showed that the prepared QDs with an average diameter of 6 nm have favorable fluorescence, which is greatly influenced by the pH of the environment. The interaction of some heavy metal ions including Ag+, Hg2+, Cu2+, Ni2+ and Co2+ with MSA‐capped CdS QDs was investigated in different buffering pH media. Based on the fluorescence quenching of the QDs in the presence of each of the metal ions, the feasibility of their determinations was examined according to the Stern–Volmer equation. The investigations showed that Hg(II) ions can be determined in the presence of many co‐existing metal ions at a buffering pH of 5. This method was satisfactorily applied to the measurement of Hg(II) ions in some environmental samples. Copyright © 2014 John Wiley & Sons, Ltd.
- 14 January 2014
- Published by Wiley in Luminescence
- Vol. 29 (7) , 798-804
Study of fluorescence quenching of mercaptosuccinic acid‐capped CdS quantum dots in the presence of some heavy metal ions and its application to Hg(II) ion determination
In this study, CdS quantum dots (QDs) capped with mercaptosuccinic acid (MSA) were prepared in one step. The size, shape, component and spectral properties of MSA‐capped CdS QDs were characterized by transmission electron microscopy (TEM), photoluminescence (PL) and infrared (IR) spectrometry. The results showed that the prepared QDs with an average diameter of 6 nm have favorable fluorescence, which is greatly influenced by the pH of the environment. The interaction of some heavy metal ions including Ag+, Hg2+, Cu2+, Ni2+ and Co2+ with MSA‐capped CdS QDs was investigated in different buffering pH media. Based on the fluorescence quenching of the QDs in the presence of each of the metal ions, the feasibility of their determinations was examined according to the Stern–Volmer equation. The investigations showed that Hg(II) ions can be determined in the presence of many co‐existing metal ions at a buffering pH of 5. This method was satisfactorily applied to the measurement of Hg(II) ions in some environmental samples. Copyright © 2014 John Wiley & Sons, Ltd.