MDMichael G. Danikas

Michael G. Danikas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael G. Danikas has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ground Electric Field, Atmospheric Weather and Electric Grid Variations in Northeast Greece Influenced by the March 2012 Solar Activity and the Moderate to Intense Geomagnetic Storms

    by Georgios Anagnostopoulos, Anastasios Karkanis, Athanasios Kampatagis, Panagiotis Marhavilas, Sofia-Anna Menesidou, Dimitrios Efthymiadis, Stefanos Keskinis, Dimitar Ouzounov, Nick Hatzigeorgiu, Michael Danikas

    In a recent paper, we extended a previous study on the solar solar influence to the generation of the March 2012 heatwave in the northeastern USA. In the present study we check the possible relationship of solar activity with the early March 2012 bad weather in northeast Thrace, Greece. To this end, we examined data from various remote sensing instrumentation monitoring the Sun (SDO satellite), Interplanetary space (ACE satellite), the Earth’s magnetosphere (Earth-based measurements, NOAA-19 satellite), the top of the clouds (Terra and Aqua satellites), and the near ground atmosphere. Our comparative data analysis suggests that: (i) the winter-like weather (rainfall, fast winds, decreased temperature) in Thrace started on 6 March 2012, the same day as the heatwave started in USA, (ii) during the March 2012 winter-like event in Thrace (6–15 March), the ACE satellite recorded enhanced fluxes of solar energetic particles (SEPs), while SOHO and PAMELA recorded solar protons at very high energies (>500 MeV), (iii) Between 3–31 March, the temperature in Alexandoupoli and the ACE/EPAM solar high energy (1.88–4.70 MeV) proton flux were strongly anticorelated (r = −0.75, p = 0.5). (iv) Thrace experienced particularly intense cyclonic circulation, during periods of magnetic storms on 8–10 and 12–13 March, which occurred after the arrival at ACE of two interplanetary shock waves, on March 8 and March 11, respectively, (v) at the beginning of the two above mentioned periods large atmospheric electric fields were recorded, with values ranging between ~−2000 V/m and ~1800 V/m on 8 March, (vi) the winter-like weather on 8–10 March 2012 occurred after the detection of the main SEP event related with a coronal mass ejection released in interplanetary space as a result of intense solar flare activity observed by SDO on 7 March 2012, (vi) the 8–10 March weather was related with a deep drop of ~63 °C in the cloud top temperature measured by MODIS/Terra, which favors strong precipitation. Finally, we analyzed data from the electric power network in Thrace (~41°N) and we found, for the first time sudden voltage changes of ~3.5 kV in the electric grid in Greece, during the decay phase of the March 2012 storm series. We discuss the winter-like March 2012 event in Thrace regarding the influence of solar cosmic rays on the low troposphere mediated by positive North Atlantic Oscillation (NAO). Finally, we infer that the novel finding of the geomagnetic effects on the electric power grid in Thrace may open a new window into space weather applications research.


  • Open Access

    Extreme Bad Weather, Large Atmospheric Electric Field Fluctuations and Anomalous Changes in the High Voltage Electric Power Network in Thrace, North-East Greece, during the Solar Activity and the Magnetic Superstorm of March 2012

    by Goergios Anagnostopoulos, Anastasios Karkanis, Athanasios Kampatagis, Panagiotis K. Marhavilas, Sofia-Anna Menesidou, Dimitrios Efthymiadis, Stefanos Keskinis, Dimitar Ouzounov, Nick Hatzigeorgiu, Michael Danikas

    In a recent paper, we extended previous studies on solar-terrestrial relationships by investigating the origin of the March 2012 heatwave in northeast USA. In the present study we check the possible relationship of solar activity with the early March 2012 bad weather in northeast Thrace, Greece. To this end, we examined data from various remote sensing instrumentation monitoring the Sun (SDO satellite), the Interplanetary Space (ACE satellite), the Earth’s magnetosphere (Earth based measurements, NOAA-19 satellite), the top of the clouds (TERRA and AQUA satellites) and the near ground atmosphere. Our comparative data analysis suggests that: (i) the winter-like weather (rainfall, fast winds, decreased temperature) in Thrace started on 6 March 2012, on the same day as the heatwave starting in USA, (ii) during the March 2012 winter-like event in Thrace (6-15 March), the ACE satellite recorded enhanced fluxes of solar energetic particles (SEPs), while SOHO and PAMELA recorded solar protons at very high energies (> 500 MeV), (iii) Thrace experienced particularly intense cyclonic circulation, during periods of magnetic storms on 8 - 10 and 12-13 March, which occurred after the arrival at ACE of two interplanetary shock waves, on March 8 and March 11, respectively, (iv) at the beginning of the two above mentioned periods large atmospheric electric fields were recorded, with values ranging between ~-2000V/m - ~1800V/m on 8 March, (v) the winter-like 8-10 March 2012 weather occurred after the detection of the main SEP event related with a coronal mass ejection released in the interplanetary space as a result of intense solar flare activity observed by SDO on 7 March 2012, (vi) the 8-10 March weather was related with a deep drop of ~630C in the cloud top temperature measured by MODIS/TERRA, which favors strong precipitation. Finally, we analyzed data from the electric power network in Thrace (~410N) and we found, for the first time sudden voltage changes of ~3.5kV in the electric grid in Greece, during the decay phase of the March 2012 superstorm. We discuss the winter-like March 2012 event in Thrace in terms of solar cosmic ray influence on the low troposphere mediated by positive NAO. Finally, we infer that the novel finding of the geomagnetic effects on the electric power grid in Thrace may open a new window into space weather applications research.

  • Open Access

    A Short Review on Charge Packets and Space Charge Properties Inside Dielectrics

    by George Vardakis, Michael G. Danikas, Zenon Achillides

    An effort to highlight the role of space charges inside dielectrics and their propagation is made in the present paper. Solid insulating materials in various parts of high voltage devices and machines are crucial for the insulating performance and their reliable functioning duration. Space charge distributions and space charge propagation in the form of pulses, called charge packets, are studied in this paper pointing out on one hand the initiating mechanisms and on the other hand the propagation mechanisms of charges inside dielectrics, as they are introduced in the scientific literature. Experimental data are used from other papers, mainly those referring to space charge distributions versus space and simultaneously versus time in a classification attempt of the aforementioned parameters.


  • Open Access

    A Study on the Effectiveness of Partial Discharge Models for Various Electrical Machines’ Insulation Materials

    by Dimosthenis Verginadis, Tryfon Iakovidis, Athanasios Karlis, Michael Danikas, Jose-Alfonso Antonino-Daviu

    A vital component of electrical machines (EMs), which plays the most significant role in their reliable and proper operation, is their insulation system. Synchronous generators (SGs) are the most commonly used EMs in energy production and industry. Epoxy resin and mica are the predominant insulation materials for the SGs’ windings because their characteristics and properties are suitable for extending the lifetime of the insulation. Partial discharges (PDs) are both a symptom of insulation degradation, as they cause serious problems for insulation, and a means to identify possible insulation faults with offline and/or online PD tests and measurements. A comparison of three different equivalent circuit models of PDs occurring in different insulation materials (epoxy resin, mica, and a combination of these two) is presented in this paper. Different applied voltages and/or various geometries of voids are the factors investigated through simulations. The number of PDs, PD activity, and flashover voltages are examined in order to evaluate which of the aforementioned materials has the best reaction against PD activity.


  • Open Access

    A Critical View on the Partial Discharge Models for Various Electrical Machines’ Insulation Materials

    by Dimosthenis Verginadis, Tryfon Iakovidis, Athanasios Karlis, Michael Danikas, Jose-Alfonso Antonino-Daviu

    Synchronous generators (SGs) play a vital role in energy production as well as in the industry. Their insulation system, where epoxy resin and mica dominate among the most common insulation materials, plays the most significant role in proper operation of a SG and in extending its lifetime. Epoxy resin and mica have characteristics, which make them very good materials for a reliable SG insulation. Partial discharges (PDs) are one of the most serious problems, because they can cause problems on the SG insulation. PDs are both a symptom of insulation degradation and a means to identify possible insulation faults. Thus, it is very important to detect PDs with offline or/and online PD Tests. A comparison of different MATLAB/Simulink PD models of PDs occurring in insulation materials is presented in this paper. Epoxy resin, mica, and a combination of these two insulation materials are used for simulations in order to investigate factors, such as the applied voltage and the geometry of a void inside the insulation, and how these affect the condition of the materials and are related to PDs and flashover voltages, which may also appear in electrical machines’ insulation. The aforementioned factors are examined in order to evaluate which of the materials is affected the most and which one is the most proper for SGs’ insulation system.


  • Open Access

    Investigation on Electrical and Thermal Performance of Glass Fiber Reinforced Epoxy–MgO Nanocomposites

    by Janjanam Naveen, Myneni Sukesh Babu, Ramanujam Sarathi, Ramachandran Velmurugan, Michael G. Danikas, Athanasios Karlis

    Epoxy nanocomposites reinforced with glass fiber, have been prepared with various weight percentages (1, 3, and 5 wt.%) of MgO nanofillers to improve their electrical and thermal performance. An increase in MgO nanofiller content up to 3 wt.% tends to enhance surface discharge and corona inception voltages measured using fluorescence and UHF methods, under both AC and DC voltage profiles. Reduced initial surface potential along with increased decay rate is observed after inclusion of MgO nanoparticles. Before and after the polarity reversal phenomena, heterocharge formation is observed in the bulk of test specimens. In comparison with other test samples, the 3 wt.% sample had reflected lower electric field enhancement factor. After MgO filler was added to glass fiber reinforced polymer (GFRP) composites, the coefficient of thermal expansion (CTE) has reduced, with the 3 wt.% specimen having the lowest CTE value. TGA measurements revealed an improvement in thermal stability of the GFRP nanocomposites up on the inclusion of MgO nanofillers. Overall, the GFRP nanocomposite sample filled with 3 wt.% nano-MgO outperformed the other test samples in terms of electrical and thermal performance.


  • Open Access

    Investigation of Factors Affecting Partial Discharges on Epoxy Resin: Simulation, Experiments, and Reference on Electrical Machines

    by Dimosthenis Verginadis, Athanasios Karlis, Michael G. Danikas, Jose A. Antonino-Daviu

    In Power Systems, Synchronous Generators (SGs) are mostly used for generating electricity. Their insulation system, of which epoxy resin is a core component, plays a significant role in reliable operation. Epoxy resin has high mechanical strength, a characteristic that makes it a very good material for reliable SG insulation. Partial Discharges (PDs) are a constant threat to this insulation since they cause deterioration and consequential degradation of the aforementioned material. Therefore, it is very important to detect PDs, as they are both a symptom of insulation deterioration and a means to identify possible faults. Offline and Online PDs Tests are described, and a MATLAB/Simulink model, which simulates the capacitive model of PDs, is presented in this paper. Moreover, experiments are carried out in order to examine how the flashover voltage of epoxy resin samples is affected by different humidity levels. The main purpose of this manuscript is to investigate factors, such as the applied voltage, number, and volume of water droplets and water conductivity, which affect the condition of epoxy resin, and how these are related to PDs and flashover voltages, which may appear also in electrical machines’ insulation. The aforementioned factors may affect the epoxy resin, resulting in an increase in PDs, which in turn increases the overall Electrical Rotating Machines (EMs) risk factor.


  • Open Access

    Breakdown in Nanofluids: A Short Review on Experimental Results and Related Mechanisms

    by M. Danikas

    Nanofluids seem to gradualy become an alternative to traditional insulating liquids, such as transformer oil. In this paper, a short review of experimental results as well as of possible breakdown mechanisms and of some of the factors affecting the breakdown strength of the said fluids is conducted. Most of the reports suggest that the addition of nanoparticles in insulating liquids improves the breakdown strength. However, some reports that contradict the above are also to be found. In view of this, an outline of future research is discussed. This review does not encompass all possible effects, parameters and factors affecting nanofluids but it is solely concerned with breakdown strength.


  • Applying WPD and SVD to Classification of EM Wave Induced by Partial Discharge in Power Transformer

    by Xu Zhao, Yong-Hong Cheng, Yong-Peng Meng, Michael G. Danikas

    Partial discharge (PD) current is an impulse signal at nanosecond level, which can generate electromagnetic (EM) wave containing broadband frequency information. The frequency band of EM signal is from MHz up to GHz. Due to different PD patterns, impulse currents with different shapes induce different EM waves containing different frequency information. Therefore, using the features extracted from frequency domain of EM signals, the classification of PD patterns can be effectively got. It is good to use wavelet or wavelet packet decomposition to select features. However, if the decomposition level is too shallow to find enough effective features, it cannot group the EM signals to the right pattern. On the contrary, although it is easier to find features to distinguish the PD pattern if the decomposition level is deep, there will be a lot of redundancy variables and it is hard to select features among so many variables. In this paper, a method is presented, which selected features in the whole decomposition tree instead of selecting among the leaf node of the tree, because more potential features can be found in the whole tree. With the present method, it is possible not only to get enough features, but also to eliminate the redundancy variables effectively. In order to validate the method, large EM signals from four PD patterns in a power transformer are acquired as the training data and testing data for feature selection and classification, and three common classification methods are introduced to classify the PD patterns using the features selected by the method. Most of the classification results are satisfactory indicating that the proposed method is effective.


  • Experimental Data on Epoxy Resin Samples: Small Partial Discharges at Inception Voltage and Some Thoughts on the Possibility of the Existence of Charging Phenomena Below Inception Voltage

    by Michael Danikas, Xu Zhao, Yong-Hong Cheng

    Experimental Data on Epoxy Resin Samples: Small Partial Discharges at Inception Voltage and Some Thoughts on the Possibility of the Existence of Charging Phenomena Below Inception Voltage: In this paper, some results are presented on experiments concerning partial discharges (PD) behavior of epoxy resin samples. The main idea is to see whether a sample with PD at its inception voltage, still presents some tendency to charging effects below inception. An effort is being made to relate the present work with previous publications on the same main idea. The experiment arrangement is three layers of epoxy resin with a void in middle layer. Different level voltages under inception voltage are applied to the arrangement and different PD waves are registered under different level voltages. To make sure that the tendency to charging effects below inception, infrared spectrum analysis is also conducted and the result is content to clarify our objective.