Markus Aschwanden
Research Subjects
Markus Aschwanden has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Deniz Bilecen
Department of Diagnostic Radiology, University of Basel, Petersgraben 4, CH-4031 Basel, Switzerland
3 shared publications Georg Bongartz
3 shared publications- Anja-Carina Schulte
Kantonsspital Bruderholz
2 shared publications Christoph Thalhammer
Department of Angiology, University Hospital Basel, Basel, Switzerland
2 shared publications- Deniz Bilecen
University Hospital Bruderholz Department of Radiology and Nuclear Medicine Basel Switzerland
2 shared publications Hanns G. Heidecker
2 shared publications
Latest Publications
- 7 June 2017
- Published by Oxford University Press (OUP) in Rheumatology
- Vol. 56 (10) , 1818-1819
Takayasu arteritis: active or not, that’s the question
Rheumatology key messageWith the current diagnostic tools it is difficult to assess disease activity in Takayasu arteritis.
- 7 June 2017
- Published by Oxford University Press (OUP) in Rheumatology
- Vol. 56 (10) , 1818-1819
Takayasu arteritis: active or not, that’s the question
Rheumatology key messageWith the current diagnostic tools it is difficult to assess disease activity in Takayasu arteritis.
- 12 June 2012
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 34 (01) , 47-50
Temporal Artery Compression Sign - A Novel Ultrasound Finding for the Diagnosis of Giant Cell Arteritis
Purpose: In patients with suspected giant cell arteritis (GCA), a search for the perivascular halo sign, a sophisticated color duplex ultrasound (CDU) finding, at experienced centers reliably identifies inflamed temporal arteries (TA). We tested whether TA compression in patients with GCA, a simple, largely operator-independent maneuver, elicits contrasting echogenicity between the diseased artery wall and the surrounding tissue (compression sign). Materials and Methods: 80 individuals with suspected GCA were prospectively enrolled in this single-center study. In all study participants, bilateral ultrasound examination of the TA established the presence/absence of the halo and compression sign. A positive compression sign was defined as visibility of the TA upon transducer-imposed compression of the artery. Based on ACR criteria, a team of specialized physicians independently grouped patients as GCA versus non-GCA. Results: 43/80 study participants were grouped as GCA. Both the halo sign and the compression sign were positive in 34/43 patients in the GCA group, and negative in all 37/37 of the non-GCA group, resulting in a sensitivity of 79 % and a specificity of 100 % for both the halo and the compression sign. Conclusion: In this cohort of individuals with suspected GCA, the halo sign and the compression sign were equal in their diagnostic performance. The simplicity of the compression sign suggests a level of reliability warranting further evaluation. Ziel: Das perivaskuläre Halo-Zeichen der Temporalarterie gilt als zuverlässiges diagnostisches Zeichen zum Nachweis einer Riesenzellarteritis (RZA), ist aber auch für erfahrene Spezialisten anspruchsvoll zu dokumentieren. In dieser Studie wurde erstmals untersucht, ob die einfacher durchzuführende Methode der Kompression der Temporalarterie (Kompressions-Zeichen) ein ausreichend gutes Zeichen darstellt, um die veränderte Gefäßwand bei Patienten mit RZA zuverlässig zu erkennen. Material und Methoden: Patienten mit Verdacht auf RZA wurden zwischen März 2009 und September 2011 prospektiv eingeschlossen. Bei allen Patienten wurde bilateral mittels Ultraschall ein Halo- resp. ein Kompressionszeichen der Temporalarterie gesucht. Eine persistierend sichtbare Temporalarterie unter vollständiger Kompression des Gefäßes wurde als positives Kompressions-Zeichen gewertet. Die endgültige Diagnose RZA versus „andere Diagnose“ wurde durch Fachärzte, welche nicht in die Ultraschalluntersuchung involviert waren, unter Berücksichtigung aller Befunde und der ACR-Kriterien gestellt. Ergebnisse: 43/80 Patienten wiesen eine RZA auf, 34 davon mit positivem Halo- resp. Kompression-Zeichen. Keiner der 37 Patienten ohne RZA hatte ein positives Halo- oder Kompressionszeichen. Die Sensitivität resp. Spezifität des Halo- und des Kompressions-Zeichens bezogen auf die Diagnose RZA betrug für beide je 79 % resp. 100 %. Schlussfolgerung: In diesem Kollektiv von Patienten mit vermuteter RZA wiesen das Halo- und das Kompressions-Zeichen die gleiche diagnostische Wertigkeit auf. Die einfachere Anwendbarkeit und die diagnostische Zuverlässigkeit des Kompressions-Zeichens haben das Potenzial, zukünftig die Diagnostik in diesem Bereich zu erleichtern. Das Kompressions-Zeichen sollte deswegen weiter prospektiv evaluiert werden. * Equal contributors.
- 12 June 2012
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 34 (01) , 47-50
Temporal Artery Compression Sign - A Novel Ultrasound Finding for the Diagnosis of Giant Cell Arteritis
Purpose: In patients with suspected giant cell arteritis (GCA), a search for the perivascular halo sign, a sophisticated color duplex ultrasound (CDU) finding, at experienced centers reliably identifies inflamed temporal arteries (TA). We tested whether TA compression in patients with GCA, a simple, largely operator-independent maneuver, elicits contrasting echogenicity between the diseased artery wall and the surrounding tissue (compression sign). Materials and Methods: 80 individuals with suspected GCA were prospectively enrolled in this single-center study. In all study participants, bilateral ultrasound examination of the TA established the presence/absence of the halo and compression sign. A positive compression sign was defined as visibility of the TA upon transducer-imposed compression of the artery. Based on ACR criteria, a team of specialized physicians independently grouped patients as GCA versus non-GCA. Results: 43/80 study participants were grouped as GCA. Both the halo sign and the compression sign were positive in 34/43 patients in the GCA group, and negative in all 37/37 of the non-GCA group, resulting in a sensitivity of 79 % and a specificity of 100 % for both the halo and the compression sign. Conclusion: In this cohort of individuals with suspected GCA, the halo sign and the compression sign were equal in their diagnostic performance. The simplicity of the compression sign suggests a level of reliability warranting further evaluation. Ziel: Das perivaskuläre Halo-Zeichen der Temporalarterie gilt als zuverlässiges diagnostisches Zeichen zum Nachweis einer Riesenzellarteritis (RZA), ist aber auch für erfahrene Spezialisten anspruchsvoll zu dokumentieren. In dieser Studie wurde erstmals untersucht, ob die einfacher durchzuführende Methode der Kompression der Temporalarterie (Kompressions-Zeichen) ein ausreichend gutes Zeichen darstellt, um die veränderte Gefäßwand bei Patienten mit RZA zuverlässig zu erkennen. Material und Methoden: Patienten mit Verdacht auf RZA wurden zwischen März 2009 und September 2011 prospektiv eingeschlossen. Bei allen Patienten wurde bilateral mittels Ultraschall ein Halo- resp. ein Kompressionszeichen der Temporalarterie gesucht. Eine persistierend sichtbare Temporalarterie unter vollständiger Kompression des Gefäßes wurde als positives Kompressions-Zeichen gewertet. Die endgültige Diagnose RZA versus „andere Diagnose“ wurde durch Fachärzte, welche nicht in die Ultraschalluntersuchung involviert waren, unter Berücksichtigung aller Befunde und der ACR-Kriterien gestellt. Ergebnisse: 43/80 Patienten wiesen eine RZA auf, 34 davon mit positivem Halo- resp. Kompression-Zeichen. Keiner der 37 Patienten ohne RZA hatte ein positives Halo- oder Kompressionszeichen. Die Sensitivität resp. Spezifität des Halo- und des Kompressions-Zeichens bezogen auf die Diagnose RZA betrug für beide je 79 % resp. 100 %. Schlussfolgerung: In diesem Kollektiv von Patienten mit vermuteter RZA wiesen das Halo- und das Kompressions-Zeichen die gleiche diagnostische Wertigkeit auf. Die einfachere Anwendbarkeit und die diagnostische Zuverlässigkeit des Kompressions-Zeichens haben das Potenzial, zukünftig die Diagnostik in diesem Bereich zu erleichtern. Das Kompressions-Zeichen sollte deswegen weiter prospektiv evaluiert werden. * Equal contributors.
- 1 March 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (3) , 775-784
Pedal Angiography in Peripheral Arterial Occlusive Disease: First-Pass IV Contrast-Enhanced MR Angiography with Blood Pool Contrast Medium Versus Intraarterial Digital Subtraction Angiography
OBJECTIVE. The purpose of this study was to prospectively evaluate first-pass IV gadofosveset–enhanced MR angiography in patients with peripheral arterial occlusive disease for visualization of the pedal arteries and stenosis or occlusion of those arteries with intraarterial digital subtraction angiography as the reference standard. SUBJECTS AND METHODS. Twenty patients with peripheral arterial occlusive disease (nine women, 11 men; age-range 58–83 years) were prospectively enrolled. Gadofosveset first-pass contrast-enhanced MR angiography was performed with a 1.5-T system, a dedicated foot coil, and cuff compression to the calf. Arterial segments were assessed for degree of arterial stenosis, arterial visibility, diagnostic utility, and venous contamination. Detection of vessel stenosis or occlusion was evaluated in comparison with findings at digital subtraction angiography. The unpaired Student's t test was used to test arterial visibility with the two techniques. RESULTS. First-pass MR angiography with gadofosveset had good diagnostic utility in 83.9% of all segments and no venous contamination in 96.8% of all segments. There was no difference between the performance of intraarterial digital subtraction angiography and that of IV contrast-enhanced MR angiography in arterial visibility overall (p = 0.245) or in subgroup analysis of surgical arterial bypass targets (p = 0.202). The overall sensitivity, specificity, and accuracy of IV gadofosveset–enhanced MR angiography for characterization of clinically significant stenosis and occlusion were 91.4%, 96.1%, and 93.9%. In the subgroup analysis, the sensitivity, specificity, and accuracy were 85.5%, 96.5%, and 92.1%. CONCLUSION. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with peripheral arterial occlusive disease has arterial visibility equal to that of digital subtraction angiography and facilitates depiction of clinically significant stenosis and occlusion.
- 1 March 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (3) , 775-784
Pedal Angiography in Peripheral Arterial Occlusive Disease: First-Pass IV Contrast-Enhanced MR Angiography with Blood Pool Contrast Medium Versus Intraarterial Digital Subtraction Angiography
OBJECTIVE. The purpose of this study was to prospectively evaluate first-pass IV gadofosveset–enhanced MR angiography in patients with peripheral arterial occlusive disease for visualization of the pedal arteries and stenosis or occlusion of those arteries with intraarterial digital subtraction angiography as the reference standard. SUBJECTS AND METHODS. Twenty patients with peripheral arterial occlusive disease (nine women, 11 men; age-range 58–83 years) were prospectively enrolled. Gadofosveset first-pass contrast-enhanced MR angiography was performed with a 1.5-T system, a dedicated foot coil, and cuff compression to the calf. Arterial segments were assessed for degree of arterial stenosis, arterial visibility, diagnostic utility, and venous contamination. Detection of vessel stenosis or occlusion was evaluated in comparison with findings at digital subtraction angiography. The unpaired Student's t test was used to test arterial visibility with the two techniques. RESULTS. First-pass MR angiography with gadofosveset had good diagnostic utility in 83.9% of all segments and no venous contamination in 96.8% of all segments. There was no difference between the performance of intraarterial digital subtraction angiography and that of IV contrast-enhanced MR angiography in arterial visibility overall (p = 0.245) or in subgroup analysis of surgical arterial bypass targets (p = 0.202). The overall sensitivity, specificity, and accuracy of IV gadofosveset–enhanced MR angiography for characterization of clinically significant stenosis and occlusion were 91.4%, 96.1%, and 93.9%. In the subgroup analysis, the sensitivity, specificity, and accuracy were 85.5%, 96.5%, and 92.1%. CONCLUSION. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with peripheral arterial occlusive disease has arterial visibility equal to that of digital subtraction angiography and facilitates depiction of clinically significant stenosis and occlusion.
- 15 April 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 71 (6) , 744-746
Cutaneous migration of the StarClose® device
We report the first case of a transcutaneous migration of a vascular clip closure device 10 weeks after placement during femoral artery puncture for percutaneous transluminal angioplasty. We postulate focal inflammatory vascular wall changes as the predisposing factor in this patient with giant cell arteritis.
- 15 April 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 71 (6) , 744-746
Cutaneous migration of the StarClose® device
We report the first case of a transcutaneous migration of a vascular clip closure device 10 weeks after placement during femoral artery puncture for percutaneous transluminal angioplasty. We postulate focal inflammatory vascular wall changes as the predisposing factor in this patient with giant cell arteritis.
- 1 January 2007
- Vol. 36 (1) , 65-73
Effect of silver-threads-containing compression stockings on the cutaneous microcirculation: a double-blind, randomized cross-over study.
Recently silver fiber-containing compression stockings for the use in patients with chronic venous insufficiency (CVI) were introduced to the market. In order to gain some first insight into the effects of these new fabrics on the cutaneous microcirculation, a double-blind, randomized cross-over trial was performed in 10 healthy volunteers. A 3 days run-in phase preceded the (2 x10 days) treatment phases and was used to assess the reproducibility of the primary endpoint, which was the transcutaneous partial oxygen pressure (tcpO(2)) measured at a probe temperature of 44 degrees C in the perimalleolar region of the reference leg in supine and dependent leg positions. Coefficients of variation for double measured tcpO(2) values were 4.2% (3.1 SD) and 5.8% (6.0 SD) for the leg in supine and dependent position. The intra-individual comparison of the effects from both treatment phases (value end of treatment - start of treatment) resulted in a negative tcpO(2) net balance for the regular hosiery (-0.93 (2.7 SD) mmHg, supine; -1.1 (3.5 SD) mmHg, dependent) but a positive net balance for the silver fibers containing stockings (0.25 (4.0 SD) mmHg, supine; 1.7 (3.9 SD) mmHg, dependent). The inter-treatment differences were statistically significant for the leg in a dependent position. The trial provides first evidence that interweaving silver threads into regular compression stockings may result in a positive effect regarding the nutritive skin perfusion.
- 1 January 2007
- Vol. 36 (1) , 65-73
Effect of silver-threads-containing compression stockings on the cutaneous microcirculation: a double-blind, randomized cross-over study.
Recently silver fiber-containing compression stockings for the use in patients with chronic venous insufficiency (CVI) were introduced to the market. In order to gain some first insight into the effects of these new fabrics on the cutaneous microcirculation, a double-blind, randomized cross-over trial was performed in 10 healthy volunteers. A 3 days run-in phase preceded the (2 x10 days) treatment phases and was used to assess the reproducibility of the primary endpoint, which was the transcutaneous partial oxygen pressure (tcpO(2)) measured at a probe temperature of 44 degrees C in the perimalleolar region of the reference leg in supine and dependent leg positions. Coefficients of variation for double measured tcpO(2) values were 4.2% (3.1 SD) and 5.8% (6.0 SD) for the leg in supine and dependent position. The intra-individual comparison of the effects from both treatment phases (value end of treatment - start of treatment) resulted in a negative tcpO(2) net balance for the regular hosiery (-0.93 (2.7 SD) mmHg, supine; -1.1 (3.5 SD) mmHg, dependent) but a positive net balance for the silver fibers containing stockings (0.25 (4.0 SD) mmHg, supine; 1.7 (3.9 SD) mmHg, dependent). The inter-treatment differences were statistically significant for the leg in a dependent position. The trial provides first evidence that interweaving silver threads into regular compression stockings may result in a positive effect regarding the nutritive skin perfusion.
- 1 July 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 187 (1) , 242-247
Fluoroscopic Contrast-Enhanced MR Angiography with a Magnetization-Prepared Steady-State Free Precession Technique in Peripheral Arterial Occlusive Disease
OBJECTIVE. The objective of our study was to evaluate the feasibility of intraarterial (IA) near-real-time contrast-enhanced MR angiography (CE-MRA) with a frame rate of 1.3 frames per second in seven patients with lower extremity peripheral arterial occlusive disease (PAOD). For optimized background suppression, a modified 2D steady-state free precession (SSFP) technique with magnetization preparation and mask subtraction was developed. The femoropopliteal and infrapopliteal arteries were covered in two separate steps. Acceptable contrast-to-noise ratios were obtained, and road maps were reconstructed from the same data set. CONCLUSION. Mastering IA near-real-time CE-MRA, including road map reconstruction, with an SSFP technique in the lower extremity of patients with PAOD is an important building block toward successfully performing endovascular catheter MR-guided interventions.
- 1 July 2006
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 187 (1) , 242-247
Fluoroscopic Contrast-Enhanced MR Angiography with a Magnetization-Prepared Steady-State Free Precession Technique in Peripheral Arterial Occlusive Disease
OBJECTIVE. The objective of our study was to evaluate the feasibility of intraarterial (IA) near-real-time contrast-enhanced MR angiography (CE-MRA) with a frame rate of 1.3 frames per second in seven patients with lower extremity peripheral arterial occlusive disease (PAOD). For optimized background suppression, a modified 2D steady-state free precession (SSFP) technique with magnetization preparation and mask subtraction was developed. The femoropopliteal and infrapopliteal arteries were covered in two separate steps. Acceptable contrast-to-noise ratios were obtained, and road maps were reconstructed from the same data set. CONCLUSION. Mastering IA near-real-time CE-MRA, including road map reconstruction, with an SSFP technique in the lower extremity of patients with PAOD is an important building block toward successfully performing endovascular catheter MR-guided interventions.
- Open Access
- 9 January 2006
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 21 (3) , 825-826
Renal vein thrombosis after renal transplantation – early diagnosis by duplex sonography prevented fatal outcome
1Department of Angiology2 Department of Transplant Immunology and Nephrology3 Department of Vascular Surgery University Hospital Basel Switzerland
- 9 January 2006
- Published by Oxford University Press (OUP) in Nephrology Dialysis Transplantation
- Vol. 21 (3) , 825-826
Open AccessRenal vein thrombosis after renal transplantation – early diagnosis by duplex sonography prevented fatal outcome
1Department of Angiology2 Department of Transplant Immunology and Nephrology3 Department of Vascular Surgery University Hospital Basel Switzerland
- 1 January 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (1) , 250-255
Lower Extremity: Low-Dose Contrast Agent Intraarterial MR Angiography in Patients—Initial Results
Institutional review board approval and patient consent were obtained. A low-dose injection protocol for intraarterial three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography was derived from femoral flow phantom studies and prospectively evaluated in patients with peripheral arterial occlusive disease (PAOD). All MR angiograms were obtained at 1.5 T with a T1-weighted gradient-echo sequence. MR angiograms of a gadolinium dilution series (0.8-200.0 mmol/L) were acquired in a femoral phantom at different flow rates. Signal-to-noise ratios (SNRs) above the 75% threshold of the measured maximum were considered optimal. The lowest optimal concentration was injected intraarterially in nine patients to obtain 3D MR angiograms of the thigh and calf station. Contrast-to-noise ratios (CNRs) were calculated for four arterial segments. The low optimal concentration of 50 mmol/L (20-mL bolus volume), about 5% of the total permissible dose, showed SNRs larger than the 75% threshold in the phantom study. In patients, this concentration led to high-spatial-resolution angiograms with mean CNRs of 70.0 +/- 14.5 (+/- standard deviation) for the superficial femoral artery and 47.5 +/- 13.4 at the infrapopliteal level. Low-dose contrast agent intraarterial 3D MR angiography showed high arterial enhancement, enabling assessment of lower extremity arteries in patients with PAOD and multiple injections--a crucial precondition for MR-guided endovascular interventions.
- 1 January 2005
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (1) , 250-255
Lower Extremity: Low-Dose Contrast Agent Intraarterial MR Angiography in Patients—Initial Results
Institutional review board approval and patient consent were obtained. A low-dose injection protocol for intraarterial three-dimensional (3D) gadolinium-enhanced magnetic resonance (MR) angiography was derived from femoral flow phantom studies and prospectively evaluated in patients with peripheral arterial occlusive disease (PAOD). All MR angiograms were obtained at 1.5 T with a T1-weighted gradient-echo sequence. MR angiograms of a gadolinium dilution series (0.8-200.0 mmol/L) were acquired in a femoral phantom at different flow rates. Signal-to-noise ratios (SNRs) above the 75% threshold of the measured maximum were considered optimal. The lowest optimal concentration was injected intraarterially in nine patients to obtain 3D MR angiograms of the thigh and calf station. Contrast-to-noise ratios (CNRs) were calculated for four arterial segments. The low optimal concentration of 50 mmol/L (20-mL bolus volume), about 5% of the total permissible dose, showed SNRs larger than the 75% threshold in the phantom study. In patients, this concentration led to high-spatial-resolution angiograms with mean CNRs of 70.0 +/- 14.5 (+/- standard deviation) for the superficial femoral artery and 47.5 +/- 13.4 at the infrapopliteal level. Low-dose contrast agent intraarterial 3D MR angiography showed high arterial enhancement, enabling assessment of lower extremity arteries in patients with PAOD and multiple injections--a crucial precondition for MR-guided endovascular interventions.
- Open Access
- 16 July 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 20 (2) , 347-351
Infragenual cuff-compression reduces venous contamination in contrast-enhanced MR angiography of the calf
- 16 July 2004
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 20 (2) , 347-351
Open AccessInfragenual cuff-compression reduces venous contamination in contrast-enhanced MR angiography of the calf
- 1 January 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (1) , 180-182
Optimized Assessment of Hand Vascularization on Contrast-Enhanced MR Angiography with a Subsystolic Continuous Compression Technique
- 1 January 2004
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 182 (1) , 180-182
Optimized Assessment of Hand Vascularization on Contrast-Enhanced MR Angiography with a Subsystolic Continuous Compression Technique