Susanne Fuchs
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Susanne Fuchs has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
D. Rosenbaum
Department of Orthopaedics University Hospital Muenster Albert‐Schweitzer‐Strasse 33 48129 Muenster
5 shared publicationsAdrian Skwara
4 shared publicationsCarsten O. Tibesku
4 shared publicationsDieter Rosenbaum
Department of Orthopaedics University Hospital Muenster Albert‐Schweitzer‐Strasse 33 48149 Münster Germany
4 shared publicationsA. Skwara
3 shared publicationsH. Laaß
Elisabeth Hospital Iserlohn Germany
3 shared publications
Latest Publications
- 1 May 2007
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 12 (3) , 160-167
Fluoroscopic navigation system for hip surface replacement
- 1 May 2007
- Published by Taylor & Francis in Computer Aided Surgery
- Vol. 12 (3) , 160-167
Fluoroscopic navigation system for hip surface replacement
- 1 November 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (11) , 1493-1498
Intraarticular Hyaluronic Acid versus Glucocorticoid Injections for Nonradicular Pain in the Lumbar Spine
- 1 November 2005
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 16 (11) , 1493-1498
Intraarticular Hyaluronic Acid versus Glucocorticoid Injections for Nonradicular Pain in the Lumbar Spine
- 26 May 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (8) , 664-669
Preliminary results after total knee arthroplasty without femoral trochlea: evaluation of clinical results, quality of life and gait function
Evaluation of the clinical and functional results of a new prosthetic knee design with conservation of the physiologic properties of the patellofemoral joint. After total knee arthroplasty there are often patella problems. Some of them may be a result of excessive retropatellar pressure caused by the prosthetic design. Twelve patients with an average age of 68.6 years were evaluated after a follow‐up of 16.4 months after implantation of a new prosthetic design. The clinical results were evaluated with the Hospital for Special Surgery Scores (HSS) and the Knee Society Clinical Rating Systems (KSS). Pain was rated on a Visual Analog Scale (VAS). Quality of life was determined with the SF‐36 questionnaire. Furthermore, clinical gait analysis was performed with a 3D motion analysis system and force plates as well as surface electromyography of seven lower extremity muscles. The HSS‐Score reached a mean value of 79.3 points. The KSS reached 82.3 points for the knee score and 75 points for the functional score. The VAS for pain revealed an average value of 1.7. For the gait analysis only three parameters indicated significant differences between the affected and the contralateral leg. The mean EMG amplitude revealed a significant difference only for the biceps femoris. The clinical and functional outcome of a new prosthesis design show satisfactory results. Even if the presented results appear promising, a further application and long term results are needed.
- 26 May 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (8) , 664-669
Preliminary results after total knee arthroplasty without femoral trochlea: evaluation of clinical results, quality of life and gait function
Evaluation of the clinical and functional results of a new prosthetic knee design with conservation of the physiologic properties of the patellofemoral joint. After total knee arthroplasty there are often patella problems. Some of them may be a result of excessive retropatellar pressure caused by the prosthetic design. Twelve patients with an average age of 68.6 years were evaluated after a follow‐up of 16.4 months after implantation of a new prosthetic design. The clinical results were evaluated with the Hospital for Special Surgery Scores (HSS) and the Knee Society Clinical Rating Systems (KSS). Pain was rated on a Visual Analog Scale (VAS). Quality of life was determined with the SF‐36 questionnaire. Furthermore, clinical gait analysis was performed with a 3D motion analysis system and force plates as well as surface electromyography of seven lower extremity muscles. The HSS‐Score reached a mean value of 79.3 points. The KSS reached 82.3 points for the knee score and 75 points for the functional score. The VAS for pain revealed an average value of 1.7. For the gait analysis only three parameters indicated significant differences between the affected and the contralateral leg. The mean EMG amplitude revealed a significant difference only for the biceps femoris. The clinical and functional outcome of a new prosthesis design show satisfactory results. Even if the presented results appear promising, a further application and long term results are needed.
- 5 May 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (8) , 670-676
Preliminary remarks on a prospective multicenter study of the Repicci minimally invasive unicondylar knee replacement
Prospective multicentric study on unicondylar knee arthroplasties using the minimally invasive method described by Repicci. Three hundred and seventy nine unicondylar knee arthroplasties in patients with an average age of 66 years were examined preoperatively and 40 weeks postoperatively. In 98.4% of the cases the medial compartment was replaced. The examination was documented using the Knee Society Score (KSS). Radiological examination was done using films of the knee in two planes in standing position and a long leg axis film. The mean KSS increased significantly (P<0.005) from 100.1 (SD 21.7) before surgery to 179.1 (SD 24.0) postoperatively. Ninety‐five of the patients were subjectively satisfied with the procedure. Using correlation analysis, we found that osteoarthritic changes of the patella had a highly significant (p=0.001) influence on the KSS results. Patient's age and the pain subscale of the KSS also had a highly significant (p=0.01) influence on the KSS result. Short‐term results of the Repicci unicondylar arthroplasty using the minimally invasive technique are encouraging in terms of patient satisfaction. It became apparent that osteoarthritic changes of the patella, flexion contractures and extension deficits have a considerable influence on the overall result.
- 5 May 2005
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (8) , 670-676
Preliminary remarks on a prospective multicenter study of the Repicci minimally invasive unicondylar knee replacement
Prospective multicentric study on unicondylar knee arthroplasties using the minimally invasive method described by Repicci. Three hundred and seventy nine unicondylar knee arthroplasties in patients with an average age of 66 years were examined preoperatively and 40 weeks postoperatively. In 98.4% of the cases the medial compartment was replaced. The examination was documented using the Knee Society Score (KSS). Radiological examination was done using films of the knee in two planes in standing position and a long leg axis film. The mean KSS increased significantly (P<0.005) from 100.1 (SD 21.7) before surgery to 179.1 (SD 24.0) postoperatively. Ninety‐five of the patients were subjectively satisfied with the procedure. Using correlation analysis, we found that osteoarthritic changes of the patella had a highly significant (p=0.001) influence on the KSS results. Patient's age and the pain subscale of the KSS also had a highly significant (p=0.01) influence on the KSS result. Short‐term results of the Repicci unicondylar arthroplasty using the minimally invasive technique are encouraging in terms of patient satisfaction. It became apparent that osteoarthritic changes of the patella, flexion contractures and extension deficits have a considerable influence on the overall result.
- 24 December 2004
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (3) , 197-202
Clinical and functional comparison of uni‐ and bicondylar sledge prostheses
The aim of the present study was the evaluation of differences in clinical results, proprioceptive performance and gait in patients with unicondylar and bicondylar sledge prostheses of the knee. In a retrospective study, 17 patients with unicondylar sledge prostheses were compared with 15 patients with bicondylar sledge prostheses. Clinical examination was rated using HSS, Knee Society, and patellar scores and a visual analogue scale for pain. Proprioceptive performance was examined using sway measurements during single leg stance on a force platform. In addition, the patients underwent 3‐D gait analysis including measurements of ground reaction forces and surface electromyographic (EMG) investigation of the lower extremity. Comparing both patient groups in clinical scores, gait, EMG and proprioception, no significant differences were found. Implantation of bicondylar sledge prostheses retaining both cruciate ligaments achieves functional results as good as unicompartmental arthroplasty. The presented results might encourage future research on new models of total joint replacement with preservation of both cruciate ligaments.
- 24 December 2004
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (3) , 197-202
Clinical and functional comparison of uni‐ and bicondylar sledge prostheses
The aim of the present study was the evaluation of differences in clinical results, proprioceptive performance and gait in patients with unicondylar and bicondylar sledge prostheses of the knee. In a retrospective study, 17 patients with unicondylar sledge prostheses were compared with 15 patients with bicondylar sledge prostheses. Clinical examination was rated using HSS, Knee Society, and patellar scores and a visual analogue scale for pain. Proprioceptive performance was examined using sway measurements during single leg stance on a force platform. In addition, the patients underwent 3‐D gait analysis including measurements of ground reaction forces and surface electromyographic (EMG) investigation of the lower extremity. Comparing both patient groups in clinical scores, gait, EMG and proprioception, no significant differences were found. Implantation of bicondylar sledge prostheses retaining both cruciate ligaments achieves functional results as good as unicompartmental arthroplasty. The presented results might encourage future research on new models of total joint replacement with preservation of both cruciate ligaments.
- 1 July 2004
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 22 (4) , 774-780
Expression of the CD44 variant isoform 5 in the human osteoarthritic knee joint: Correlation with radiological, histomorphological, and biochemical parameters
The purpose of this study was to correlate expression of CD44v5 in osteoarthritic synovium, cartilage, and synovial fluid with radiographical, histomorphological, and biochemical data.Cartilage and synovia specimens of 27 patients with osteoarthritis were histomorphologically assessed according to Mankin and Pelletier, respectively. Extended weight-bearing antero-posterior radiographs were evaluated according to Kellgren and Ahlback. Expression of membrane-bound CD44v5 was analyzed by immunohistochemistry and levels of soluble CD44v5 were determined by ELISA.Expression of CD44v5 in cartilage and synovia was detected in 67% and 59% of the patients, respectively. Immunohistochemical findings in cartilage correlated significantly with structural cartilage changes (p < 0.001), whereas no correlation was found between expression in synovia and inflammatory synovial changes. Additionally, no relationship was evident between CD44v5 expression and radiographical data, but expression in cartilage and synovium was significantly correlated with each other (p < 0.04). Surprisingly, expression of CD44v5 in both cartilage and synovia was negatively correlated with synovial fluid levels of TNFalpha (p < 0.03 and p < 0.02, respectively), and no association was evident with levels of IL-1beta.The data demonstrate expression of CD44v5 in osteoarthritic cartilage and synovia, probably independent of joint inflammation. But more importantly, expression of this receptor variant in cartilage seems to be strongly related to the degree of cartilage destruction.
- 1 July 2004
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 22 (4) , 774-780
Expression of the CD44 variant isoform 5 in the human osteoarthritic knee joint: Correlation with radiological, histomorphological, and biochemical parameters
The purpose of this study was to correlate expression of CD44v5 in osteoarthritic synovium, cartilage, and synovial fluid with radiographical, histomorphological, and biochemical data.Cartilage and synovia specimens of 27 patients with osteoarthritis were histomorphologically assessed according to Mankin and Pelletier, respectively. Extended weight-bearing antero-posterior radiographs were evaluated according to Kellgren and Ahlback. Expression of membrane-bound CD44v5 was analyzed by immunohistochemistry and levels of soluble CD44v5 were determined by ELISA.Expression of CD44v5 in cartilage and synovia was detected in 67% and 59% of the patients, respectively. Immunohistochemical findings in cartilage correlated significantly with structural cartilage changes (p < 0.001), whereas no correlation was found between expression in synovia and inflammatory synovial changes. Additionally, no relationship was evident between CD44v5 expression and radiographical data, but expression in cartilage and synovium was significantly correlated with each other (p < 0.04). Surprisingly, expression of CD44v5 in both cartilage and synovia was negatively correlated with synovial fluid levels of TNFalpha (p < 0.03 and p < 0.02, respectively), and no association was evident with levels of IL-1beta.The data demonstrate expression of CD44v5 in osteoarthritic cartilage and synovia, probably independent of joint inflammation. But more importantly, expression of this receptor variant in cartilage seems to be strongly related to the degree of cartilage destruction.
- 2 June 2004
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (3) , 179-186
Clinical and functional results after the rehabilitation period in minimally‐invasive unicondylar knee arthroplasty patients
The objective of the present study was to analyze the clinical and functional outcome after minimally‐invasive implantation of a Repicci‐type unicompartmental sledge prosthesis. In 29 patients with primary unicompartmental knee osteoarthritis, 29 replacements of the medial compartment and four of the lateral compartment were performed using the minimally‐invasive technique with the metal‐backed and the all‐polyethylene versions of the Repicci sledge prosthesis. Electromyography (EMG) of standardized locations was measured with the MyoSystem 2000 and analyzed with Myoresearch software. Gait analysis was performed with a six‐camera motion analysis system and force platforms. Established clinical and quality of life (SF‐36) scores were used to compare patients with 11 healthy age‐matched individuals. The Repicci sledge prosthesis led postoperatively to functional results that were in the range of healthy joints, and superior to sledge prostheses of a different design. Gait and balance parameters were comparable to the control group, whilst electromyographically lower amplitudes were found in the patients than the controls and in the operated legs as compared to the non‐operated legs. Many parameters of quality of life and activity were comparable to age‐matched healthy individuals, and quality of life was superior to total knee replacement. When implanted using a minimally‐invasive technique and with suitable patient selection, the Repicci sledge led to functional results comparable to those of healthy joints and gait parameters comparable to those of healthy individuals. The level of evidence is Level III, retrospective cohort study.
- 2 June 2004
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 13 (3) , 179-186
Clinical and functional results after the rehabilitation period in minimally‐invasive unicondylar knee arthroplasty patients
The objective of the present study was to analyze the clinical and functional outcome after minimally‐invasive implantation of a Repicci‐type unicompartmental sledge prosthesis. In 29 patients with primary unicompartmental knee osteoarthritis, 29 replacements of the medial compartment and four of the lateral compartment were performed using the minimally‐invasive technique with the metal‐backed and the all‐polyethylene versions of the Repicci sledge prosthesis. Electromyography (EMG) of standardized locations was measured with the MyoSystem 2000 and analyzed with Myoresearch software. Gait analysis was performed with a six‐camera motion analysis system and force platforms. Established clinical and quality of life (SF‐36) scores were used to compare patients with 11 healthy age‐matched individuals. The Repicci sledge prosthesis led postoperatively to functional results that were in the range of healthy joints, and superior to sledge prostheses of a different design. Gait and balance parameters were comparable to the control group, whilst electromyographically lower amplitudes were found in the patients than the controls and in the operated legs as compared to the non‐operated legs. Many parameters of quality of life and activity were comparable to age‐matched healthy individuals, and quality of life was superior to total knee replacement. When implanted using a minimally‐invasive technique and with suitable patient selection, the Repicci sledge led to functional results comparable to those of healthy joints and gait parameters comparable to those of healthy individuals. The level of evidence is Level III, retrospective cohort study.
- 1 May 2004
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 12 (5) , 409-418
Differential induction and regulation of matrix metalloproteinases in osteoarthritic tissue and fluid synovial fibroblasts
- 1 May 2004
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 12 (5) , 409-418
Differential induction and regulation of matrix metalloproteinases in osteoarthritic tissue and fluid synovial fibroblasts
- 1 March 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (3) , 263-269
Clinical and functional comparison of bicondylar sledge prostheses retaining all ligaments and constrained total knee replacement
- 1 March 2004
- Published by Elsevier in Clinical Biomechanics
- Vol. 19 (3) , 263-269
Clinical and functional comparison of bicondylar sledge prostheses retaining all ligaments and constrained total knee replacement