Sadanori Sekiya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sadanori Sekiya has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
Koichi Tanaka
Koichi Tanaka Mass Spectrometry Research Laboratory Shimadzu Corporation 1 Nishinokyo‐Kuwabaracho Nakagyo‐ku Kyoto 604‐8511 Japan
3 shared publicationsKenichi Taniguchi
Koichi Tanaka Mass Spectrometry Research Laboratory Shimadzu Corporation 1 Nishinokyo‐Kuwabaracho Nakagyo‐ku Kyoto 604‐8511 Japan
1 shared publication- Koichi Kato
Exploratory Research Center on Life and Living Systems (ExCELLS), National Institutes of Natural Sciences, Okazaki, Japan
1 shared publication - Koichi Tanaka
Department of Chemistry and Materials Engineering
1 shared publication Yoshiki Yamaguchi
Graduate School of Pharmaceutical Sciences, Nagoya City University, 3-1 Tanabe-dori, Mizuho-ku, Nagoya 467-8603, Japan
1 shared publicationYoshinao Wada
Koichi Tanaka Mass Spectrometry Research Laboratory, Shimadzu Corporation, 1, Nishinokyo-Kuwabaracho, Nakagyo-ku, Kyoto 604-8511, Japan, and Osaka Medical Center and Research Institute for Maternal and Child Health, 840 Murodo-cho. Izumi, Osaka 594-1101, Japan
1 shared publication
Latest Publications
- 10 February 2012
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 26 (6) , 693-700
On‐target separation of analyte with 3‐aminoquinoline/α‐cyano‐4‐hydroxycinnamic acid liquid matrix for matrix‐assisted laser desorption/ionization mass spectrometry
3‐Aminoquinoline/α‐cyano‐4‐hydroxycinnamic acid (3AQ/CHCA) is a liquid matrix (LM), which was reported by Kumar et al . in 1996 for matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. It is a viscous liquid and has some advantages of durability of ion generation by a self‐healing surface and quantitative performance. In this study, we found a novel aspect of 3AQ/CHCA as a MALDI matrix, which converges hydrophilic material into the center of the droplet of analyte‐3AQ/CHCA mixture on a MALDI sample target well during the process of evaporation of water derived from analyte solvent. This feature made it possible to separate not only the buffer components, but also the peptides and oligosaccharides from one another within 3AQ/CHCA. The MALDI imaging analyses of the analyte‐3AQ/CHCA droplet indicated that the oligosaccharides and the peptides were distributed in the center and in the whole area around the center of 3AQ/CHCA, respectively. This 'on‐target separation' effect was also applicable to glycoprotein digests such as ribonuclease B. These features of 3AQ/CHCA liquid matrix eliminate the requirement for pretreatment, and reduce sample handling losses thus resulting in the improvement of throughput and sensitivity. Copyright © 2012 John Wiley & Sons, Ltd.
- 10 February 2012
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 26 (6) , 693-700
On‐target separation of analyte with 3‐aminoquinoline/α‐cyano‐4‐hydroxycinnamic acid liquid matrix for matrix‐assisted laser desorption/ionization mass spectrometry
3‐Aminoquinoline/α‐cyano‐4‐hydroxycinnamic acid (3AQ/CHCA) is a liquid matrix (LM), which was reported by Kumar et al . in 1996 for matrix‐assisted laser desorption/ionization (MALDI) mass spectrometry. It is a viscous liquid and has some advantages of durability of ion generation by a self‐healing surface and quantitative performance. In this study, we found a novel aspect of 3AQ/CHCA as a MALDI matrix, which converges hydrophilic material into the center of the droplet of analyte‐3AQ/CHCA mixture on a MALDI sample target well during the process of evaporation of water derived from analyte solvent. This feature made it possible to separate not only the buffer components, but also the peptides and oligosaccharides from one another within 3AQ/CHCA. The MALDI imaging analyses of the analyte‐3AQ/CHCA droplet indicated that the oligosaccharides and the peptides were distributed in the center and in the whole area around the center of 3AQ/CHCA, respectively. This 'on‐target separation' effect was also applicable to glycoprotein digests such as ribonuclease B. These features of 3AQ/CHCA liquid matrix eliminate the requirement for pretreatment, and reduce sample handling losses thus resulting in the improvement of throughput and sensitivity. Copyright © 2012 John Wiley & Sons, Ltd.
- 29 June 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (15) , 4962-4968
Derivatization for Stabilizing Sialic Acids in MALDI-MS
While matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is useful in oligosaccharide analysis, the sialic acid, or N-acetylneuraminic acid (NANA), moiety of an oligosaccharide is liable to dissociation in- or postsource during mass measurement. In this study, we tried to stabilize the moiety by amidation, as in the case of peptides (Sekiya, S.; Wada, Y. Tanaka, K. Anal. Chem. 2004, 76, 5894−5902), and found 4-(4,6-dimethoxy-1,3,5-triazin-2yl)-4-methylmorpholinium chloride to be a desirable condensing agent. Amidation stabilized the glycosidic bond with NANA and suppressed its preferential cleavage by in-source decay, postsource decay, or collision-induced dissociation. In addition, the suppressed dissociation considerably improved the yield of the B/Y type ions for structural analysis by MS/MS. These results demonstrate that amidation is an effective derivatization to reinforce the structural analysis of sialylated oligosaccharides by MALDI-MS. In addition, amidation with 15N-labeled ammonium chloride decreases the mass shift from the acid to amide form to just 0.013, reducing the complexity of mass spectral interpretation and database searching.
- 29 June 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (15) , 4962-4968
Derivatization for Stabilizing Sialic Acids in MALDI-MS
While matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is useful in oligosaccharide analysis, the sialic acid, or N-acetylneuraminic acid (NANA), moiety of an oligosaccharide is liable to dissociation in- or postsource during mass measurement. In this study, we tried to stabilize the moiety by amidation, as in the case of peptides (Sekiya, S.; Wada, Y. Tanaka, K. Anal. Chem. 2004, 76, 5894−5902), and found 4-(4,6-dimethoxy-1,3,5-triazin-2yl)-4-methylmorpholinium chloride to be a desirable condensing agent. Amidation stabilized the glycosidic bond with NANA and suppressed its preferential cleavage by in-source decay, postsource decay, or collision-induced dissociation. In addition, the suppressed dissociation considerably improved the yield of the B/Y type ions for structural analysis by MS/MS. These results demonstrate that amidation is an effective derivatization to reinforce the structural analysis of sialylated oligosaccharides by MALDI-MS. In addition, amidation with 15N-labeled ammonium chloride decreases the mass shift from the acid to amide form to just 0.013, reducing the complexity of mass spectral interpretation and database searching.
- 8 September 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (19) , 5894-5902
Improvement of the MS/MS Fragment Ion Coverage of Acidic Residue-Containing Peptides by Amidation with 15N-Substituted Amine
Tandem mass spectrometry (MS/MS) is a powerful tool for peptide sequencing and characterization. However, the selective cleavage at acidic residues, aspartic acid, and glutamic acid prevents the generation of enough product ions to elucidate the entire sequence. We attempted to solve the problem by converting the residues into the corresponding amides, asparagine and glutamine. The amidation suppressed the cleavage at the converted residues, and the product ions derived from dissociation at other sites became abundant. Incorporation of nitrogen isotope 15N in the amine constituent for amidation minimized the mass change from −0.984 016 to +0.013 019, allowing easy discrimination of acidic and amide residues in the original sequences by MS/MS database search. In addition, the amidated and unchanged peptides had the same nominal mass, even when the transformation was incomplete, which was ∼70% in the current condition. The unmodified acidic residues remaining were rather useful to give marker fragments by the dominant dissociation. These results demonstrate that 15N-amidation is effective in improving the performance of MS/MS to elucidate amino acid sequences of peptides.
- 8 September 2004
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 76 (19) , 5894-5902
Improvement of the MS/MS Fragment Ion Coverage of Acidic Residue-Containing Peptides by Amidation with 15N-Substituted Amine
Tandem mass spectrometry (MS/MS) is a powerful tool for peptide sequencing and characterization. However, the selective cleavage at acidic residues, aspartic acid, and glutamic acid prevents the generation of enough product ions to elucidate the entire sequence. We attempted to solve the problem by converting the residues into the corresponding amides, asparagine and glutamine. The amidation suppressed the cleavage at the converted residues, and the product ions derived from dissociation at other sites became abundant. Incorporation of nitrogen isotope 15N in the amine constituent for amidation minimized the mass change from −0.984 016 to +0.013 019, allowing easy discrimination of acidic and amide residues in the original sequences by MS/MS database search. In addition, the amidated and unchanged peptides had the same nominal mass, even when the transformation was incomplete, which was ∼70% in the current condition. The unmodified acidic residues remaining were rather useful to give marker fragments by the dominant dissociation. These results demonstrate that 15N-amidation is effective in improving the performance of MS/MS to elucidate amino acid sequences of peptides.