Jérôme Taveau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jérôme Taveau has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
Benoît Moras
Institut de Radioprotection et de Sûreté Nucléaire, IRSN/DSU/SERIC/BEXI, 31, avenue de la Division Leclerc, 92 260 FONTENAY AUX ROSES cedex, France
1 shared publication
Latest Publications
- 17 February 2012
- Published by Wiley in Process Safety Progress
- Vol. 31 (3) , 230-239
Explosion of fixed roof atmospheric storage tanks, part 3: Gas explosion and structural response simulations
Many flammable products are stored in large tanks at atmospheric pressure. Ignition of a hydrocarbon–air mixture in such tanks can lead to an explosion and cause lethal casualties or damage the surrounding facilities and buildings. To apprehend this, safety distances for humans, structures, and equipments need to be defined. Several simple methodologies have been set up to estimate safety distances in case of an atmospheric storage tank explosion.This third and last article concerning fixed roof atmospheric storage tank explosions focuses on numerical modeling, including gas explosion and structural response simulations.Three‐dimensional gas explosion simulations using the CFD code FLACS have been performed to define a typical pressure load profile to apply on the inner side of the tank shell. Then, the structural response of the tank (deformation and displacement), under the loading conditions previously obtained, has been computed with LS–DYNA.Consequently, the findings question some of the assumptions used in analytical methods described previously.The specific input data needed to obtain a reasonably conservative estimation of the safety distances have been identified. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2012
- 17 February 2012
- Published by Wiley in Process Safety Progress
- Vol. 31 (3) , 230-239
Explosion of fixed roof atmospheric storage tanks, part 3: Gas explosion and structural response simulations
Many flammable products are stored in large tanks at atmospheric pressure. Ignition of a hydrocarbon–air mixture in such tanks can lead to an explosion and cause lethal casualties or damage the surrounding facilities and buildings. To apprehend this, safety distances for humans, structures, and equipments need to be defined. Several simple methodologies have been set up to estimate safety distances in case of an atmospheric storage tank explosion.This third and last article concerning fixed roof atmospheric storage tank explosions focuses on numerical modeling, including gas explosion and structural response simulations.Three‐dimensional gas explosion simulations using the CFD code FLACS have been performed to define a typical pressure load profile to apply on the inner side of the tank shell. Then, the structural response of the tank (deformation and displacement), under the loading conditions previously obtained, has been computed with LS–DYNA.Consequently, the findings question some of the assumptions used in analytical methods described previously.The specific input data needed to obtain a reasonably conservative estimation of the safety distances have been identified. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2012
- 26 August 2011
- Published by Wiley in Process Safety Progress
- Vol. 30 (4) , 381-392
Explosion of fixed roof atmospheric storage tanks, part 1: Background and review of case histories
Many flammable products are stored in large tanks at atmospheric pressure. Ignition of a hydrocarbon–air mixture in such tanks can lead to an explosion and cause lethal casualties or damage the surrounding facilities and buildings. To apprehend this, safety distances for humans, structures and equipments need to be defined. Several simple methodologies have been set up to estimate safety distances in case of an atmospheric storage tank explosion.This first article gives an overview of accident frequencies of atmospheric storage tanks and past accidents described in the open literature, to show the possible accidental sequences, underline the most frequent causes involved in explosions of atmospheric storage tank, and highlight the potential consequences of such accidents. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2011
- 26 August 2011
- Published by Wiley in Process Safety Progress
- Vol. 30 (4) , 381-392
Explosion of fixed roof atmospheric storage tanks, part 1: Background and review of case histories
Many flammable products are stored in large tanks at atmospheric pressure. Ignition of a hydrocarbon–air mixture in such tanks can lead to an explosion and cause lethal casualties or damage the surrounding facilities and buildings. To apprehend this, safety distances for humans, structures and equipments need to be defined. Several simple methodologies have been set up to estimate safety distances in case of an atmospheric storage tank explosion.This first article gives an overview of accident frequencies of atmospheric storage tanks and past accidents described in the open literature, to show the possible accidental sequences, underline the most frequent causes involved in explosions of atmospheric storage tank, and highlight the potential consequences of such accidents. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2011
- 8 August 2011
- Published by Wiley in Process Safety Progress
- Vol. 31 (1) , 36-50
Secondary dust explosions: How to prevent them or mitigate their effects?
Dust explosions are frequent and particularly devastating in the process industries. Secondary dust explosions are the most severe ones, and occur when the blast wave from a primary explosion entrains dust layers already present in the plant, creating a large dust‐air flammable mixture ignited by the first explosion. As the blast wave propagates through the plant, dust fuels the emerging flame, leading to extensive damage owing to the large quantity of dusts involved and the consequent strong pressure wave.Several cases of secondary dust explosions have been analyzed by Eckhoff. Major accidents have also occurred in the US in recent years, causing the Chemical Safety Board (CSB) to produce a specific report highlighting the increasing number of dust explosions. An illustration of this point is the massive explosion that occurred on 7 February 2008 at the Imperial Sugar Company in Port Wentworth (Georgia), causing 14 fatalities and injuring 36 people.The consequences of secondary dust explosions can be disastrous. However, only a minor initiating “primary” explosion can quickly develop into a major secondary explosion if appropriate measures have not been taken in advance.This article describes several secondary dust explosion accidents that occurred in France and in the US and present some practical solutions to prevent or mitigate these accidents. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2012
- 8 August 2011
- Published by Wiley in Process Safety Progress
- Vol. 31 (1) , 36-50
Secondary dust explosions: How to prevent them or mitigate their effects?
Dust explosions are frequent and particularly devastating in the process industries. Secondary dust explosions are the most severe ones, and occur when the blast wave from a primary explosion entrains dust layers already present in the plant, creating a large dust‐air flammable mixture ignited by the first explosion. As the blast wave propagates through the plant, dust fuels the emerging flame, leading to extensive damage owing to the large quantity of dusts involved and the consequent strong pressure wave.Several cases of secondary dust explosions have been analyzed by Eckhoff. Major accidents have also occurred in the US in recent years, causing the Chemical Safety Board (CSB) to produce a specific report highlighting the increasing number of dust explosions. An illustration of this point is the massive explosion that occurred on 7 February 2008 at the Imperial Sugar Company in Port Wentworth (Georgia), causing 14 fatalities and injuring 36 people.The consequences of secondary dust explosions can be disastrous. However, only a minor initiating “primary” explosion can quickly develop into a major secondary explosion if appropriate measures have not been taken in advance.This article describes several secondary dust explosion accidents that occurred in France and in the US and present some practical solutions to prevent or mitigate these accidents. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2012
- 14 July 2011
- Published by Wiley in Process Safety Progress
- Vol. 31 (1) , 55-71
The Buncefield explosion: Were the resulting overpressures really unforeseeable?
On Sunday 11 December 2005, a severe unconfined vapor cloud explosion followed by several tank fires occurred at the Buncefield oil storage depot in England, near London, causing widespread damage to homes and businesses surrounding the site, hopefully without any victim.The damage caused by the resulting blast wave(s) surprised all the process safety community and explosion experts, as common hazard assessments would have predicted overpressures of only 5 kPa (0.73 psi), instead of 200 kPa (29 psi) as suggested by the data collected onsite.One of the particularities of the Buncefield oil storage depot is that it was surrounded by long and continuous rows of trees and bushes; this singularity is currently considered as a preponderant factor in the resulting high overpressures.Recently, explanations of the resulting overpressures were given by some authors using data from large‐scale explosion tests and CFD simulations.The objective of this article is to verify whether application of simple methodologies used in common risk assessments could allow to estimate the severity of the Buncefield explosion. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2012
- 14 July 2011
- Published by Wiley in Process Safety Progress
- Vol. 31 (1) , 55-71
The Buncefield explosion: Were the resulting overpressures really unforeseeable?
On Sunday 11 December 2005, a severe unconfined vapor cloud explosion followed by several tank fires occurred at the Buncefield oil storage depot in England, near London, causing widespread damage to homes and businesses surrounding the site, hopefully without any victim.The damage caused by the resulting blast wave(s) surprised all the process safety community and explosion experts, as common hazard assessments would have predicted overpressures of only 5 kPa (0.73 psi), instead of 200 kPa (29 psi) as suggested by the data collected onsite.One of the particularities of the Buncefield oil storage depot is that it was surrounded by long and continuous rows of trees and bushes; this singularity is currently considered as a preponderant factor in the resulting high overpressures.Recently, explanations of the resulting overpressures were given by some authors using data from large‐scale explosion tests and CFD simulations.The objective of this article is to verify whether application of simple methodologies used in common risk assessments could allow to estimate the severity of the Buncefield explosion. © 2011 American Institute of Chemical Engineers Process Saf Prog, 2012
- 31 January 2011
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 24 (1) , 8-18
Explosion hazards related to hydrogen releases in nuclear facilities
- 31 January 2011
- Published by Elsevier in Journal of Loss Prevention in the Process Industries
- Vol. 24 (1) , 8-18
Explosion hazards related to hydrogen releases in nuclear facilities