Vladimir Mironov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Vladimir Mironov has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Vladimir Kasyanov
Department of Rehabilitation, Riga Stradins University, 16 Dzirciema Street, Riga LV-1007, Latvia
9 shared publicationsRoger R. Markwald
Bioprinting Research Center, Cardiovascular Developmental Biology Center, Department of Cell Biology and Anatomy, Medical University of South Carolina, Charleston, SC 29425, USA
7 shared publicationsRoger R Markwald
Advanced Tissue Biofabrication Center, Department of Regenerative Medicine and Cell Biology, Medical University of South Carolina, 173 Ashley Avenue, Charleston, SC 29425, USA
5 shared publications- Carmine Gentile
University of Technology Sydney Faculty of Engineering, Building 11, Level 10, Room 115, 81 Broadway St, Ultimo, Sydney, Ultimo, Sydney, New South Wales, 2007, AUSTRALIA
3 shared publications Glenn D. Prestwich
The University of Utah
3 shared publicationsThomas Trusk
Medical University of South Carolina, Charleston, South Carolina, USA
3 shared publications
Latest Publications
- 23 August 2013
- Published by Taylor & Francis in Connective Tissue Research
- Vol. 54 (6) , 394-402
Age-related analysis of structural, biochemical and mechanical properties of the porcine mitral heart valve leaflets
The aim of this study was to assess structural and biochemical differences in the extracellular matrix of the fetal and adult porcine mitral heart valves in relation to their mechanical characteristics. Using tensile tests it was demonstrated that the material properties of porcine mitral heart valves progressively change with age. The collagen content of the adult heart valve, as estimated by hydroxyproline assay, increases three times as compared with fetal heart valves. Transmission electron microscopy demonstrated that the diameter of collagen fibrils increased in adult heart valves compared with fetal heart valves. The level of collagen cross-linking is lower in the fetal heart valve than the adult heart valve. The reported age differences in the material properties of fetal and adult porcine heart valves were associated with increases in collagen content, the diameter of collagen fibrils and the level of collagen cross-linking. These data lay a foundation for systematic elucidation of the structural determinants of material properties of heart valves during embryonic and postnatal valvulogenesis. They are also essential to define the desirable level of tissue maturation in heart valve tissue engineering.
- 23 August 2013
- Published by Taylor & Francis in Connective Tissue Research
- Vol. 54 (6) , 394-402
Age-related analysis of structural, biochemical and mechanical properties of the porcine mitral heart valve leaflets
The aim of this study was to assess structural and biochemical differences in the extracellular matrix of the fetal and adult porcine mitral heart valves in relation to their mechanical characteristics. Using tensile tests it was demonstrated that the material properties of porcine mitral heart valves progressively change with age. The collagen content of the adult heart valve, as estimated by hydroxyproline assay, increases three times as compared with fetal heart valves. Transmission electron microscopy demonstrated that the diameter of collagen fibrils increased in adult heart valves compared with fetal heart valves. The level of collagen cross-linking is lower in the fetal heart valve than the adult heart valve. The reported age differences in the material properties of fetal and adult porcine heart valves were associated with increases in collagen content, the diameter of collagen fibrils and the level of collagen cross-linking. These data lay a foundation for systematic elucidation of the structural determinants of material properties of heart valves during embryonic and postnatal valvulogenesis. They are also essential to define the desirable level of tissue maturation in heart valve tissue engineering.
- 16 November 2011
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 6 (4) , 197-213
Toward organ printing: Design characteristics, virtual modelling and physical prototyping vascular segments of kidney arterial tree
Organ printing is defined as the layer by layer additive biofabrication of three-dimensional (3D) tissue and organ constructs using tissue spheroids as building blocks. Ultimately, successful bioprinting of human organ constructs is dependent on a ‘built in’ vascular tree to perfuse and maintain the viability of the organ constructs. Thus, the design of the vascular tree is a critically important step in practical implementation of organ printing technology. Bioprinting a vascular tree requires detailed knowledge of the morphometrical, morphological and biomechanical characteristics of the sequentially branched segments of the natural vascular tree as well as insight on post-printing tissue compaction and remodelling. Toward accomplishing this goal, we characterised the morphometrical, morphological and biomechanical characteristics of the initial segments of the natural kidney arterial vascular tree of the porcine kidney. Computer simulation was used to model compaction of tissue engineered tubular vascular segments with different wall thicknesses virtually biofabricated from closely packed and fused uniformly sized vascular tissue spheroids. The number of concentric layers of tissue spheroids required to bioprint tubular vascular segments with desirable wall thickness and diameter was theoretically estimated. Our results demonstrate that vascular segment compaction correlates well with reported experimental data. Finally, physical prototyping of linear and branched tubular constructs using silicon droplets as physical analogues of tissue spheroids was performed. Thus, virtual and physical prototyping provide important insights into the design parameters and demonstrate the principal feasibility of bioprinting a branched vascular tree using vascular tissue spheroids.
- 16 November 2011
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 6 (4) , 197-213
Toward organ printing: Design characteristics, virtual modelling and physical prototyping vascular segments of kidney arterial tree
Organ printing is defined as the layer by layer additive biofabrication of three-dimensional (3D) tissue and organ constructs using tissue spheroids as building blocks. Ultimately, successful bioprinting of human organ constructs is dependent on a ‘built in’ vascular tree to perfuse and maintain the viability of the organ constructs. Thus, the design of the vascular tree is a critically important step in practical implementation of organ printing technology. Bioprinting a vascular tree requires detailed knowledge of the morphometrical, morphological and biomechanical characteristics of the sequentially branched segments of the natural vascular tree as well as insight on post-printing tissue compaction and remodelling. Toward accomplishing this goal, we characterised the morphometrical, morphological and biomechanical characteristics of the initial segments of the natural kidney arterial vascular tree of the porcine kidney. Computer simulation was used to model compaction of tissue engineered tubular vascular segments with different wall thicknesses virtually biofabricated from closely packed and fused uniformly sized vascular tissue spheroids. The number of concentric layers of tissue spheroids required to bioprint tubular vascular segments with desirable wall thickness and diameter was theoretically estimated. Our results demonstrate that vascular segment compaction correlates well with reported experimental data. Finally, physical prototyping of linear and branched tubular constructs using silicon droplets as physical analogues of tissue spheroids was performed. Thus, virtual and physical prototyping provide important insights into the design parameters and demonstrate the principal feasibility of bioprinting a branched vascular tree using vascular tissue spheroids.
- Top Cited Papers
- 1 October 2011
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 22 (5) , 667-673
Organ printing: from bioprinter to organ biofabrication line
- 1 October 2011
- Published by Elsevier in Current Opinion in Biotechnology
- Vol. 22 (5) , 667-673
Top Cited PapersOrgan printing: from bioprinter to organ biofabrication line
- 12 May 2011
- Published by IOP Publishing in Biofabrication
- Vol. 3 (2) , 025002
Scalable robotic biofabrication of tissue spheroids
Development of methods for scalable biofabrication of uniformly sized tissue spheroids is essential for tissue spheroid-based bioprinting of large size tissue and organ constructs. The most recent scalable technique for tissue spheroid fabrication employs a micromolded recessed template prepared in a non-adhesive hydrogel, wherein the cells loaded into the template self-assemble into tissue spheroids due to gravitational force. In this study, we present an improved version of this technique. A new mold was designed to enable generation of 61 microrecessions in each well of a 96-well plate. The microrecessions were seeded with cells using an EpMotion 5070 automated pipetting machine. After 48 h of incubation, tissue spheroids formed at the bottom of each microrecession. To assess the quality of constructs generated using this technology, 600 tissue spheroids made by this method were compared with 600 spheroids generated by the conventional hanging drop method. These analyses showed that tissue spheroids fabricated by the micromolded method are more uniform in diameter. Thus, use of micromolded recessions in a non-adhesive hydrogel, combined with automated cell seeding, is a reliable method for scalable robotic fabrication of uniform-sized tissue spheroids.
- 12 May 2011
- Published by IOP Publishing in Biofabrication
- Vol. 3 (2) , 025002
Scalable robotic biofabrication of tissue spheroids
Development of methods for scalable biofabrication of uniformly sized tissue spheroids is essential for tissue spheroid-based bioprinting of large size tissue and organ constructs. The most recent scalable technique for tissue spheroid fabrication employs a micromolded recessed template prepared in a non-adhesive hydrogel, wherein the cells loaded into the template self-assemble into tissue spheroids due to gravitational force. In this study, we present an improved version of this technique. A new mold was designed to enable generation of 61 microrecessions in each well of a 96-well plate. The microrecessions were seeded with cells using an EpMotion 5070 automated pipetting machine. After 48 h of incubation, tissue spheroids formed at the bottom of each microrecession. To assess the quality of constructs generated using this technology, 600 tissue spheroids made by this method were compared with 600 spheroids generated by the conventional hanging drop method. These analyses showed that tissue spheroids fabricated by the micromolded method are more uniform in diameter. Thus, use of micromolded recessions in a non-adhesive hydrogel, combined with automated cell seeding, is a reliable method for scalable robotic fabrication of uniform-sized tissue spheroids.
- 8 January 2010
- Published by Informa Healthcare in Expert Opinion on Biological Therapy
- Vol. 10 (3) , 409-420
Towards organ printing: engineering an intra-organ branched vascular tree
Importance of the field: Effective vascularization of thick three-dimensional engineered tissue constructs is a problem in tissue engineering. As in native organs, a tissue-engineered intra-organ v...
- 8 January 2010
- Published by Informa Healthcare in Expert Opinion on Biological Therapy
- Vol. 10 (3) , 409-420
Towards organ printing: engineering an intra-organ branched vascular tree
Importance of the field: Effective vascularization of thick three-dimensional engineered tissue constructs is a problem in tissue engineering. As in native organs, a tissue-engineered intra-organ v...
- 1 January 2010
- Published by ASME International
- p. 567-576
Study of Double-Layered Microcapsule Formation in Compound Nozzle Jetting
Double-layered microcapsules, which usually consist of a core (polymeric) matrix surrounded by a (polymeric) shell, have been used in many industrial and scientific applications such as microencapsulation of drugs and living cells. Compound concentric nozzle-based jetting has been favored due to its efficiency and precise control of the core-shell compound structure. Thus far, little is known about the underlying formation mechanism of double-layered microcapsules in compound nozzle jetting. This study aims to understand the formability of double-layered microcapsules in compound nozzle jetting by coupling a theoretical analysis with numerical simulations. A linear temporal instability analysis is used to define the perturbation growth rate and its ratio as a function of the wavenumber; and a computational fluid dynamics (CFD) method is implemented to model the microcapsule formation process in order to determine the good microcapsule forming range based on the growth ratio curve. Using a pseudo-bisection method, the lower and upper bounds of the good formability range have been determined for a given materials-nozzle system. The proposed formability prediction methodology has been implemented and validated in modeling a water-poly (lactide-co-glycolide) (PLGA) – air compound jetting system with satisfactory prediction results.
- 1 January 2010
- Published by ASME International
- p. 567-576
Study of Double-Layered Microcapsule Formation in Compound Nozzle Jetting
Double-layered microcapsules, which usually consist of a core (polymeric) matrix surrounded by a (polymeric) shell, have been used in many industrial and scientific applications such as microencapsulation of drugs and living cells. Compound concentric nozzle-based jetting has been favored due to its efficiency and precise control of the core-shell compound structure. Thus far, little is known about the underlying formation mechanism of double-layered microcapsules in compound nozzle jetting. This study aims to understand the formability of double-layered microcapsules in compound nozzle jetting by coupling a theoretical analysis with numerical simulations. A linear temporal instability analysis is used to define the perturbation growth rate and its ratio as a function of the wavenumber; and a computational fluid dynamics (CFD) method is implemented to model the microcapsule formation process in order to determine the good microcapsule forming range based on the growth ratio curve. Using a pseudo-bisection method, the lower and upper bounds of the good formability range have been determined for a given materials-nozzle system. The proposed formability prediction methodology has been implemented and validated in modeling a water-poly (lactide-co-glycolide) (PLGA) – air compound jetting system with satisfactory prediction results.
- 1 June 2009
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 4 (2) , 63-74
Designer ‘blueprint’ for vascular trees: morphology evolution of vascular tissue constructs
Organ printing is a variant of the biomedical application of rapid prototyping technology or layer-by-layer additive biofabrication of 3D tissue and organ constructs using self-assembled tissue spheroids as building blocks. Bioengineering of perfusable intraorgan branched vascular trees incorporated into 3D tissue constructs is essential for the survival of bioprinted thick 3D tissues and organs. In order to design the optimal ‘blueprint’ for digital bioprinting of intraorgan branched vascular trees, the coefficients of tissue retraction associated with post-printing vascular tissue spheroid fusion and remodelling must be determined and incorporated into the original CAD. Using living tissue spheroids assembled into ring-like and tube-like vascular tissue constructs, the coefficient of tissue retraction has been experimentally evaluated. It has been shown that the internal diameter of ring-like and the height of tubular-like tissue constructs are significantly reduced during tissue spheroid fusion. During the tissue fusion process, the individual tissue spheroids also change their shape from ball-like to a conus-like form. A simple formula for the calculation of the necessary number of tissue spheroids for biofabrication of ring-like structures of desirable diameter has been deduced. These data provide sufficient information to design optimal CAD for bioprinted branched vascular trees of desirable final geometry and size.
- 1 June 2009
- Published by Taylor & Francis in Virtual and Physical Prototyping
- Vol. 4 (2) , 63-74
Designer ‘blueprint’ for vascular trees: morphology evolution of vascular tissue constructs
Organ printing is a variant of the biomedical application of rapid prototyping technology or layer-by-layer additive biofabrication of 3D tissue and organ constructs using self-assembled tissue spheroids as building blocks. Bioengineering of perfusable intraorgan branched vascular trees incorporated into 3D tissue constructs is essential for the survival of bioprinted thick 3D tissues and organs. In order to design the optimal ‘blueprint’ for digital bioprinting of intraorgan branched vascular trees, the coefficients of tissue retraction associated with post-printing vascular tissue spheroid fusion and remodelling must be determined and incorporated into the original CAD. Using living tissue spheroids assembled into ring-like and tube-like vascular tissue constructs, the coefficient of tissue retraction has been experimentally evaluated. It has been shown that the internal diameter of ring-like and the height of tubular-like tissue constructs are significantly reduced during tissue spheroid fusion. During the tissue fusion process, the individual tissue spheroids also change their shape from ball-like to a conus-like form. A simple formula for the calculation of the necessary number of tissue spheroids for biofabrication of ring-like structures of desirable diameter has been deduced. These data provide sufficient information to design optimal CAD for bioprinted branched vascular trees of desirable final geometry and size.
- 1 April 2009
- Published by Elsevier in The Lancet
- Vol. 373 (9673) , 1402-1404
Emergence of clinical vascular tissue engineering
- 1 April 2009
- Published by Elsevier in The Lancet
- Vol. 373 (9673) , 1402-1404
Emergence of clinical vascular tissue engineering
- Top Cited Papers
- 1 April 2009
- Published by Elsevier in Biomaterials
- Vol. 30 (12) , 2164-2174
Organ printing: Tissue spheroids as building blocks
- 1 April 2009
- Published by Elsevier in Biomaterials
- Vol. 30 (12) , 2164-2174
Top Cited PapersOrgan printing: Tissue spheroids as building blocks
- 1 December 2008
- Published by Wiley in Developmental Dynamics
- Vol. 237 (12) , spc1
VEGF-mediated fusion in the generation of uniluminal vascular spheroids
- 1 December 2008
- Published by Wiley in Developmental Dynamics
- Vol. 237 (12) , spc1
VEGF-mediated fusion in the generation of uniluminal vascular spheroids