Hans Jürgen Scheer
Research Subjects
Hans Jürgen Scheer has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
G Curio
1 shared publication- Jaakko O. Nieminen
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
1 shared publication - Jens Voigt
Department of Cardiovascular Sciences, KU Leuven , Herestraat 49, 3000 Leuven
1 shared publication Lutz Trahms
1 shared publication- Lutz Trahms
Physikalisch-Technische Bundesanstalt
1 shared publication M Burghoff
1 shared publication
Latest Publications
- 1 September 2013
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 20 (3) , 327-336
Improved Contrast in Ultra-Low-Field MRI with Time-Dependent Bipolar Prepolarizing Fields: Theory and NMR Demonstrations
The spin-lattice (T1) relaxation rates of materials depend on the strength of the external magnetic field in which the relaxation occurs. This T1 dispersion has been suggested to offer a means to discriminate between healthy and cancerous tissue by performing magnetic resonance imaging (MRI) at low magnetic fields. In prepolarized ultra-low-field (ULF) MRI, spin precession is detected in fields of the order of 10-100 μT. To increase the signal strength, the sample is first magnetized with a relatively strong polarizing field. Typically, the polarizing field is kept constant during the polarization period. However, in ULF MRI, the polarizing-field strength can be easily varied to produce a desired time course. This paper describes how a novel variation of the polarizing-field strength and duration can optimize the contrast between two types of tissue having different T1 relaxation dispersions. In addition, NMR experiments showing that the principle works in practice are presented. The described procedure may become a key component for a promising new approach of MRI at ultra-low fields
- 1 September 2013
- Published by Polish Academy of Sciences Chancellery in Metrology and Measurement Systems
- Vol. 20 (3) , 327-336
Improved Contrast in Ultra-Low-Field MRI with Time-Dependent Bipolar Prepolarizing Fields: Theory and NMR Demonstrations
The spin-lattice (T1) relaxation rates of materials depend on the strength of the external magnetic field in which the relaxation occurs. This T1 dispersion has been suggested to offer a means to discriminate between healthy and cancerous tissue by performing magnetic resonance imaging (MRI) at low magnetic fields. In prepolarized ultra-low-field (ULF) MRI, spin precession is detected in fields of the order of 10-100 μT. To increase the signal strength, the sample is first magnetized with a relatively strong polarizing field. Typically, the polarizing field is kept constant during the polarization period. However, in ULF MRI, the polarizing-field strength can be easily varied to produce a desired time course. This paper describes how a novel variation of the polarizing-field strength and duration can optimize the contrast between two types of tissue having different T1 relaxation dispersions. In addition, NMR experiments showing that the principle works in practice are presented. The described procedure may become a key component for a promising new approach of MRI at ultra-low fields
- 17 November 2011
- Published by IOP Publishing in Physiological Measurement
- Vol. 32 (12) , N73-N79
Extension of non-invasive EEG into the kHz range for evoked thalamocortical activity by means of very low noise amplifiers
Ultrafast electroencephalographic signals, having frequencies above 500 Hz, can be observed in somatosensory evoked potential measurements. Usually, these recordings have a poor signal-to-noise ratio (SNR) because weak signals are overlaid by intrinsic noise of much higher amplitude like that generated by biological sources and the amplifier. As an example, recordings at the scalp taken during electrical stimulation of the median nerve show a 600 Hz burst with submicro-volt amplitudes which can be extracted from noise by the use of massive averaging and digital signal processing only. We have investigated this signal by means of a very low noise amplifier made in-house (minimal voltage noise 2.7 nV Hz(-1/2), FET inputs). We examined how the SNR of the data is altered by the bandwidth and the use of amplifiers with different intrinsic amplifier noise levels of 12 and 4.8 nV Hz(-1/2), respectively. By analyzing different frequency contributions of the signal, we found an extremely weak 1 kHz component superimposed onto the well-known 600 Hz burst. Previously such high-frequency electroencephalogram responses around 1 kHz have only been observed by deep brain electrodes implanted for tremor therapy of Parkinson patients. For the non-invasive measurement of such signals, we recommend that amplifier noise should not exceed 4 nV Hz(-1/2).
- 17 November 2011
- Published by IOP Publishing in Physiological Measurement
- Vol. 32 (12) , N73-N79
Extension of non-invasive EEG into the kHz range for evoked thalamocortical activity by means of very low noise amplifiers
Ultrafast electroencephalographic signals, having frequencies above 500 Hz, can be observed in somatosensory evoked potential measurements. Usually, these recordings have a poor signal-to-noise ratio (SNR) because weak signals are overlaid by intrinsic noise of much higher amplitude like that generated by biological sources and the amplifier. As an example, recordings at the scalp taken during electrical stimulation of the median nerve show a 600 Hz burst with submicro-volt amplitudes which can be extracted from noise by the use of massive averaging and digital signal processing only. We have investigated this signal by means of a very low noise amplifier made in-house (minimal voltage noise 2.7 nV Hz(-1/2), FET inputs). We examined how the SNR of the data is altered by the bandwidth and the use of amplifiers with different intrinsic amplifier noise levels of 12 and 4.8 nV Hz(-1/2), respectively. By analyzing different frequency contributions of the signal, we found an extremely weak 1 kHz component superimposed onto the well-known 600 Hz burst. Previously such high-frequency electroencephalogram responses around 1 kHz have only been observed by deep brain electrodes implanted for tremor therapy of Parkinson patients. For the non-invasive measurement of such signals, we recommend that amplifier noise should not exceed 4 nV Hz(-1/2).
- 19 December 2005
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (2) , 109-117
The influence of amplifier, interface and biological noise on signal quality in high-resolution EEG recordings
First, the intrinsic random noise sources of a biopotential measurement in general are reviewed. For the special case of an electroencephalographic (EEG) measurement we have extended the commonly used amplifier noise model by biological generated background noise. As the strongest of all noise sources involved will dominate the resulting signal to noise ratio (S/N), we have investigated under which conditions this will be the case. We illustrate experimentally that up to 100 Hz S/N practically depends only on cortical generated background noise, while at a few hundred Hz or more amplifier and thermal noise of interelectrode resistance are the major sources.
- 19 December 2005
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (2) , 109-117
The influence of amplifier, interface and biological noise on signal quality in high-resolution EEG recordings
First, the intrinsic random noise sources of a biopotential measurement in general are reviewed. For the special case of an electroencephalographic (EEG) measurement we have extended the commonly used amplifier noise model by biological generated background noise. As the strongest of all noise sources involved will dominate the resulting signal to noise ratio (S/N), we have investigated under which conditions this will be the case. We illustrate experimentally that up to 100 Hz S/N practically depends only on cortical generated background noise, while at a few hundred Hz or more amplifier and thermal noise of interelectrode resistance are the major sources.
- 1 January 2002
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 47 (s1b) , 564-565
HOCHAUFLÖSENDES EEG IM GANZKOPF-MEG
A low-noise multichannel EEG-Amplifier-System has been designed and analyzed, which is electromagnetically compatible with SQUIDs. The EEG- together with the MEG-System is operated inside the quiet environment of a magnetically shielded room, hence no electrical 50 Hz-Artifact is detectable. Measurements pointed out that the influence of amplifier- and electrochemical-noise of electrodes to averaged EEG-spectral densities is less than 1% within the frequency range 0.5 to 70 Hz. Thermal noise of the skin-electrode-interface, equivalent to a resistor of 30 k omega, only begins to take effect above 20 Hz, suggesting that there is no need of skin abrasion.
- 1 January 2002
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 47 (s1b) , 564-565
HOCHAUFLÖSENDES EEG IM GANZKOPF-MEG
A low-noise multichannel EEG-Amplifier-System has been designed and analyzed, which is electromagnetically compatible with SQUIDs. The EEG- together with the MEG-System is operated inside the quiet environment of a magnetically shielded room, hence no electrical 50 Hz-Artifact is detectable. Measurements pointed out that the influence of amplifier- and electrochemical-noise of electrodes to averaged EEG-spectral densities is less than 1% within the frequency range 0.5 to 70 Hz. Thermal noise of the skin-electrode-interface, equivalent to a resistor of 30 k omega, only begins to take effect above 20 Hz, suggesting that there is no need of skin abrasion.