SHSebastian Hahnel

Sebastian Hahnel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sebastian Hahnel has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of the flexural strength and microstructure of 3D printed and milled mono- and multilayer zirconia

    by Michael Bergler, Andreas König, Jonathan Korostoff, Francis K. Mante, Sebastian Hahnel, Martin Rosentritt


  • Open Access

    Attachment of Respiratory Pathogens and Candida to Denture Base Materials—A Pilot Study

    by Anne Schmutzler, Catalina Suzana Stingu, Elena Günther, Reinhold Lang, Florian Fuchs, Andreas Koenig, Angelika Rauch, Sebastian Hahnel

    Denture prostheses are an ideal and extensive reservoir for microorganisms to attach to their surfaces. The aim of the study was to elucidate interactions between materials for the fabrication of denture bases and the attachment of microorganisms, focusing on respiratory pathogens and Candida species. Specimens (6 mm × 1 mm) with a standardized surface roughness (Sa = 0.1 µm) were prepared from heat-pressed polymethyl methacrylate (PMMA), CAD/CAM-processed PMMA, and CAD/CAM-processed polyether ether ketone (PEEK). The specimens were randomly placed in the vestibular areas of complete upper dentures in seven patients and were removed either after 24 h without any oral hygiene measures or after a period of four weeks. The microorganisms adherent to the surface of the specimens were cultivated and subsequently analyzed using mass spectrometry (MALDI-TOF). The means and standard deviations were calculated, and the data were analyzed using a two-way analysis of variance (ANOVA) and Tukey post-hoc test where appropriate (α = 0.05). There was a significant increase (p ≤ 0.004) in the total bacterial counts (CFU/mL) between the first (24 h) and the second (four weeks) measurements. Regarding quantitative microbiological analyses, no significant differences between the various materials were identified. Respiratory microorganisms were detected in all samples at both measurement time points, with a large variance between different patients. Only after four weeks, Candida species were identified on all materials but not in all participants. Candida species and respiratory microorganisms accumulate on various denture base resins. While no significant differences were identified between the materials, there was a tendency towards a more pronounced accumulation of microorganisms on conventionally processed PMMA.


  • Open Access

    Influence of the Application Time of Silane for the Bonding Performance between Feldspar or Lithium Disilicate Ceramics and Luting Resin Composites

    by Florian Fuchs, Sina Maria Westerhove, Leonie Schmohl, Andreas Koenig, Rujito Sesariojiwandono Ridho Suharbiansah, Sebastian Hahnel, Angelika Rauch

    A correct silanization time is essential for successful surface functionalization and sufficient bonding to dental ceramics. The shear bond strength (SBS) of lithium disilicate (LDS) and feldspar (FSC) ceramics and luting resin composite was investigated with respect to different silanization times, taking into account the physical properties of the individual surfaces. The SBS test was performed with a universal testing machine, and the fracture surfaces were evaluated by stereomicroscopy. The surface roughness of the prepared specimens was analyzed after etching. Changes in surface properties due to surface functionalization were evaluated by surface free energy (SFE) via contact angle measurement. Fourier transform infrared spectroscopy (FTIR) was used to determine the chemical binding. The roughness and SBS of the control group (no silane, etched) were higher for FSC than for LDS. Regarding the SFE, the dispersive fraction increased and the polar fraction decreased after silanization. FTIR confirmed the presence of silane on the surfaces. The SBS of LDS showed a significant increase from 5 to 15 s, depending on the silane and luting resin composite. For FSC, cohesive failure was observed for all samples. For LDS specimens, a silane application time of 15 to 60 s is recommended. Based on clinical conditions, no difference between the silanization times was observed for FSC specimens, indicating that etching alone produces sufficient bonding.


  • Open Access

    TEGDMA-Functionalized Dicalcium Phosphate Dihydrate Resin-Based Composites Prevent Secondary Caries in an In Vitro Biofilm Model

    by Andrei Cristian Ionescu, Sebastian Hahnel, Marina D. S. Chiari, Andreas König, Paolo Delvecchio, Roberto Ruggiero Braga, Vanessa Zambelli, Eugenio Brambilla

    This study evaluated the efficacy of experimental TEGDMA-functionalized dicalcium phosphate dihydrate (T-DCPD) filler-based resin-based composites (RBC) in preventing caries lesions around the restoration margins (secondary caries, SC). Standardized Class-II cavities were made in sound molars with the cervical margin in dentin. Cavities were filled with a commercial resin-modified glass-ionomer cement (RMGIC) or experimental RBCs containing a bisGMA-TEGDMA resin blend and one of the following inorganic fractions: 60 wt.% Ba glass (RBC-0); 40 wt.% Ba glass and 20 wt.% T-DCPD (RBC-20); or 20 wt.% Ba glass and 40 wt.% T-DCPD (RBC-40). An open-system bioreactor produced Streptococcus mutans biofilm-driven SC. Specimens were scanned using micro-CT to evaluate demineralization depths. Scanning electron microscopy and energy-dispersive X-ray spectroscopy characterized the specimen surfaces, and antimicrobial activity, buffering effect, and ion uptake by the biofilms were also evaluated. ANOVA and Tukey’s tests were applied at p < 0.05. RBC-0 and RBC-20 showed SC development in dentin, while RBC-40 and RMGIC significantly reduced the lesion depth at the restoration margin (p < 0.0001). Initial enamel demineralization could be observed only around the RBC-0 and RBC-20 restorations. Direct antibiofilm activity can explain SC reduction by RMGIC, whereas a buffering effect on the acidogenicity of biofilm can explain the behavior of RBC-40. Experimental RBC with CaP-releasing functionalized T-DCPD filler could prevent SC with the same efficacy as F-releasing materials.


  • Open Access

    TEGDMA-Functionalized Dicalcium Phosphate Dihydrate Resin-Based Composites Prevent Secondary Caries in An In-Vitro Biofilm Model

    by Andrei Cristian Ionescu, Sebastian Hahnel, Marina D.S. Chiari, Andreas König, Paolo Delvecchio, Roberto Ruggiero Braga, Vanessa Zambelli, Eugenio Brambilla

    This study evaluated the efficacy of experimental TEGDMA-functionalized dicalcium phosphate dihydrate (T-DCPD) filler-based resin-based composites (RBC) in preventing caries lesions around the restoration margins (secondary caries”, SC). Standardized Class-II cavities were made in sound molars having the cervical margin in dentin. Cavities were filled with a commercial resin-modified glass-ionomer cement (RMGIC) or experimental RBCs containing a BisGMA-TEGDMA resin blend and one of the following inorganic fractions: 60 wt.% Ba glass (RBC-0); 40 wt.% Ba glass, 20 wt.% T-DCPD (RBC-20); 20 wt.% Ba glass, 40 wt.% T-DCPD (RBC-40). An open-system bioreactor produced S. mutans biofilm-driven SC. Specimens were scanned using micro-CT to evaluate demineralization depths. Scanning Electron Microscopy and Energy-dispersive X-ray Spectroscopy characterized the specimens’ surfaces, while antimicrobial activity, buffering effect, and ion uptake by the biofilms were also evaluated. ANOVA and Tukey’s test were applied at p<0.05. RBC-0 and RBC-20 showed SC development in dentin, while RBC-40 and RMGIC significantly reduced the lesion depth at the restoration margin (p<0.0001). Initial enamel demineralization could be observed only around RBC-0 and RBC-20 restorations. A direct antibiofilm activity could explain SC reduction by RMGIC, while a buffering effect on biofilm’s acidogenicity explained the behavior of RBC-40. Experimental RBC with CaP-releasing functionalized T-DCPD filler could prevent SC with the same efficacy as F-releasing materials.


  • Open Access

    Acid Resistance of CAD/CAM Resin Composites

    by Leonie Schmohl, Anuschka Josephine Roesner, Florian Fuchs, Maximilian Wagner, Michael Benno Schmidt, Sebastian Hahnel, Angelika Rauch, Andreas Koenig

    Acid resistance of CAD/CAM resin composites. Erosion-related tooth surface loss is closely related to acid exposure, such as contact with acidic beverages or disease-related reflux. As a result, dental restorations in affected patients are also exposed to acids, which indicates that the performance and longevity of a dental restoration is impacted by the acid resistance of the individually employed restorative materials. However, unlike for ceramic materials, the acid resistance of CAD/CAM resin composites is not commonly evaluated by the manufacturers, and no standardised test methods have yet been established. Against this background, the present in vitro study aimed to examine the long-term resistance of CAD/CAM resin composites (Brilliant Crios, Cerasmart, Grandio blocs, Lava Ultimate, Shofu Block HC) against three acidic media (tonic water, acetic acid, hydrochloric acid) as well as demineralized water and to investigate potential damage mechanisms. Changes in surface roughness (Sa) were detected by confocal laser scanning microscopy (CLSM), and changes in surface hardness were measured using Vickers hardness (HV). The damage mechanisms were analysed by scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS) and micro X-ray computer tomography (µXCT). For each material, few changes in either Sa or HV were identified for at least one of the different media; for Cerasmart, the sharpest deterioration in surface properties was observed. SEM–EDS revealed leaching of barium, aluminium, and titanium from fillers in a 2 µm zone on the rough but not on the polished surface of the specimen. Within the limitations of the current study, it can be concluded that polished CAD/CAM resin composites can be recommended for clinical use in patients with erosive conditions.


  • Open Access

    Patient satisfaction with Locator-retained overdentures

    by Christos Alamanos, Matthias Stockle, Martin Rosentritt, Sebastian Hahnel

    OA Text is an independent open-access scientific publisher showcases innovative research and ideas aimed at improving health by linking research and practice to the benefit of society.


  • Streptococcus mutans adherence and biofilm formation on experimental composites containing dicalcium phosphate dihydrate nanoparticles

    by Andrei C. Ionescu, Sebastian Hahnel, Gloria Cazzaniga, Marco Ottobelli, Roberto Ruggiero Braga, Marcela Charantola Rodrigues, Eugenio Brambilla


  • Influence of matrix and filler fraction on biofilm formation on the surface of experimental resin-based composites

    by Andrei Ionescu, Eugenio Brambilla, Daniel S. Wastl, Franz J. Giessibl, Gloria Cazzaniga, Sibylle Schneider-Feyrer, Sebastian Hahnel

    The aim of this study was to investigate the impact of resin matrix chemistry and filler fraction on biofilm formation on the surface of experimental resin-based composites (RBCs). Specimens were prepared from eight experimental RBC formulations differing in resin matrix blend (BisGMA/TEGDMA in a 7:3 wt% ratio or UDMA/aliphatic dimethacrylate in a 1:1 wt% ratio) and filler fraction (no fillers; 65 wt% dental glass with an average diameter of 7 or 0.7 µm or 65 wt% SiO2 with an average diameter of 20 nm). Surface roughness, surface free energy, and chemical surface composition were determined; surface topography was visualized using atomic force microscopy. Biofilm formation was simulated under continuous flow conditions for a 48 h period using a monospecies Streptococcus mutans and a multispecies biofilm model. In the monospecies biofilm model, the impact of the filler fraction overruled the influence of the resin matrix, indicating lowest biofilm formation on RBCs with nano-scaled filler particles and those manufactured from the neat resin blends. The multispecies model suggested a more pronounced effect of the resin matrix blend, as significantly higher biofilm formation was identified on RBCs with a UDMA/dimethacrylate matrix blend than on those including a BisGMA/TEGDMA matrix blend but analogous filler fractions. Although significant differences in surface properties between the various materials were identified, correlations between the surface properties and biofilm formation were poor, which highlights the relevance of surface topography and chemistry. These results may help to tailor novel RBC formulations which feature reduced biofilm formation on their surface.


  • Streptococcus Mutans Biofilm Formation and Release of Fluoride from Experimental Resin-based Composites Depending on Surface Treatment and S-PRG Filler Particle Fraction

    by Sebastian Hahnel, Daniel S. Wastl, Sibylle Schneider-Feyrer, Franz J. Giessibl, Eugenio Brambilla, Gloria Cazzaniga, Andrei Ionescu

    PURPOSE:\ud To evaluate fluoride release and biofilm formation on resin-based composites (RBCs) including surface pre-reacted glass ionomer (S-PRG) filler particles.\ud MATERIALS AND METHODS:\ud Specimens were prepared from experimental RBCs including different fractions of S-PRG fillers (0/10/30/50/70% w/v). RBCs were light cured against mylar strips (MYL), and 50% of the specimens were additionally polished to a high gloss (POL). Surface roughness (SR), surface free energy (SFE) and fluoride release were determined. Streptococcus mutans biofilm formation (SMBF) was simulated for 48 h and 120 h; adherent viable biomass was assessed using an MTT-based assay.\ud RESULTS:\ud The highest SR was identified for POL specimens manufactured from the RBC with a filler fraction of 70%. For all specimens and surface treatments, polishing caused an increase in surface free energy. For both MYL and POL specimens, increasing the filler fraction coincided with an increased release of fluoride; a higher release of fluoride was identified for POL specimens with filler fractions of 50% and 70% in comparison to their MYL counterparts. Release of fluoride was lower after 120 h than after 48 h. No differences in SMBF were identified between MYL and POL specimens with identical filler fractions after 48 h of biofilm formation; with increasing filler fractions, a tendency towards decreasing SMBF was observed. After 120 h, less SMBF was identified for POL specimens with filler fractions of 30%, 50% and 70% in comparison to corresponding MYL specimens.\ud CONCLUSION:\ud The inclusion of S-PRG fillers and an effective surface treatment may reduce biofilm formation on RBCs