AEAndreas Espinoza

Andreas Espinoza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andreas Espinoza has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of Therapeutic Hypothermia on Left Ventricular Function Assessed by Ultrasound Imaging

    by Andreas Espinoza, Viesturs Kerans, Anders Opdahl, Helge Skulstad, Per Steinar Halvorsen, Jan Fredrik Bugge, Erik Fosse, Thor Edvardsen


  • Open Access

    Wide sternal retraction may impede internal mammary artery graft flow and reduce myocardial function during off-pump coronary artery bypass grafting: presentation of two cases

    by Andreas Espinoza, Jacob Bergsland, Runar Lundblad, Erik Fosse

    The internal mammary artery (IMA) is routinely used for grafting of the left anterior descending coronary artery (LAD), providing good flow to the anterior left ventricle (LV) wall. Impeded IMA-to-LAD flow may result in myocardial ischaemia and haemodynamic deterioration. From a study population, we describe two incidents where myocardial ischaemia was observed during off-pump coronary artery bypass surgery (CABG), with a confirmed reduction in the IMA-to-LAD flow in one patient. In patient no. 1, normal IMA flow was assessed by transit-time flow measurement after a complete IMA-to-LAD anastomosis. The anterior LV wall thickening was monitored continuously by epicardial ultrasonic transducers. Normal wall thickening was confirmed after IMA grafting. During a wide sternal opening for circumflex grafting the anterior wall motion displayed an ischaemic pattern, with reduced systolic and increased post-systolic wall thickening. IMA flow was reduced simultaneously. When easing the sternal opening, IMA flow normalized, as did the motion pattern in the anterior LV wall. In patient no. 2, similar changes in wall thickening occurred during a wide sternal opening after IMA-to-LAD grafting. When easing the retractor, the wall thickening normalized. It is important for the surgeon to be aware of this possible cause of myocardial ischaemia, with a risk of subsequent haemodynamic deterioration. This may not only be of great importance during off-pump CABG, but can also be significant for successful weaning from the cardiopulmonary bypass machine.


  • Survival and Complications After Interventional Bronchoscopy in Malignant Central Airway Obstruction

    by Kirill Neyman, Arve Sundset, Andreas Espinoza, Johny Kongerud, Erik Fosse

    Patients with malignant airway obstruction may need endobronchial intervention to relieve the associated symptoms. We report our experience of interventional bronchoscopy with regard to complications and survival. A total of 257 patients (167 men, 90 women, median age 67 y) were treated with 360 endobronchial procedures at our department in the period from 1998 to 2009. Kaplan-Meier and Cox regression methods were used for survival analysis. The log-rank test was used for comparison. Median survival after interventional bronchoscopy was 15 weeks. Eighteen patients died within 2 weeks after the procedure. Survival in the primary lung and metastatic cancer groups was 15 and 18 weeks, respectively (P=0.25). Survival in patients with small-cell lung carcinoma and nonsmall-cell lung carcinoma was 7 and 17 weeks, respectively (P=0.04). Serious complications such as bleeding (5), pneumothorax (1), and airway obstruction during the procedure (1) were rare (1.9%). All cases of serious hemorrhage occurred in patients with metastases from renal carcinoma. Life expectancy in patients with malignant airway obstruction is short. There was no difference in survival between patients with primary and metastatic lung disease. Bronchoscopic treatment is safe and serious complications are rare. Serious hemorrhage is frequent when treating lung metastases from renal carcinoma.


  • Automated detection of myocardial ischaemia by epicardial miniature ultrasound transducers — a novel tool for patient monitoring during cardiac surgery☆

    by Andreas Espinoza, Per Steinar Halvorsen, Helge Skulstad, Runar Lundblad, Jan Fredrik Bugge, Lars Hoff, Erik Fosse, Thor Edvardsen

    Objectives: Early detection of myocardial ischaemia in cardiac surgery is important. We have developed an ultrasonic system for continuous myocardial monitoring by use of miniature transducers. The aim of this study was to investigate the system’s ability to detect ischaemia in patients undergoing off-pump coronary artery bypass grafting (CABG), and whether automated signal analysis could detect ischaemia. Methods: In 10 patients scheduled for CABG, ultrasound transducers were fixed to the epicardium in the area supplied by left anterior descending artery (LAD), and in a remote area for control. M-mode images with measurements of wall-thickening velocities were presented in real time and systolic (S′) and post-systolic velocities (PSVs) were recorded. An automated algorithm for ischaemia detection was developed, using end-systolic wall thickening as a fraction of total wall thickening. Registrations were made at baseline and during LAD occlusion. Echocardiographic strain was used as reference. Results: Nine of 10 patients developed ischaemia during LAD occlusion, with resulting decrease in systolic and increase in post-systolic wall-thickening velocities (P ≪ 0.001). In these nine patients, Vdiff shifted below zero with no overlap between baseline and LAD occlusion (P ≪ 0.001). The automated wall-thickening fraction was reduced from 0.93 ± 0.05 to 0.57 ± 0.15 (P = 0.001). A cut-off value of 0.85 could completely separate normal from ischaemic myocardium in all patients. Conclusion: The ultrasonic system detected regional ischaemia during LAD occlusion. An automated analysis algorithm demonstrated excellent ability to detect ischaemia. This technology can develop into a useful tool to detect ischaemia in cardiac surgery.


  • DIASTOLIC DYSFUNCTION INDUCED BY MILD HYPOTHERMIA ALTERS LEFT VENTRICULAR FILLING IN A PORCINE MODEL

    by Andreas W. Espinoza, Helge Skulstad, Viesturs Kerans, Per Steinar Halvorsen, Jacob Bergsland, Jan Fredrik Bugge, Thor Edvardsen

  • Open Access

    Detecting myocardial ischaemia using miniature ultrasonic transducers — a feasibility study in a porcine model☆

    by Andreas Espinoza, Per Steinar Halvorsen, Lars Hoff, Helge Skulstad, Erik Fosse, Halfdan Ihlen, Thor Edvardsen

    Background: Detection of myocardial ischaemia during and after cardiac surgery remains a challenge. Echocardiography is more sensitive in ischaemia detection than echocardiography (ECG) and haemodynamic monitoring, but demands repeated examinations for monitoring over time. We have developed and validated an ultrasonic system that permits continuous real-time assessment of myocardial ischaemia using miniature epicardial ultrasound transducers. Methods: In an open-chest porcine model (n = 8), prototype ultrasound transducers were fixed on the epicardium in the left anterior descending and circumflex coronary artery supply regions, providing continuous measurement of transmural myocardial velocities. Peak systolic velocity and post-systolic velocity were recorded simultaneously with ECG, left ventricular pressure and arterial pressure. Two-dimensional (2D) echocardiographic strain was used as a reference. Global changes were induced by infusing fluid, epinephrine, nitroprusside and esmolol. Regional changes were induced by occluding the left anterior descending coronary artery (LAD). Subsequent LAD stenosis was performed in a subgroup, with flow reduction to 50% of baseline level and further to occlusion. Results: Systolic velocity in the LAD region decreased during LAD occlusion (0.9 ± 0.1 to 0.1 ± 0.1 cm s−1, P ≪ 0.01), whereas post-systolic velocity increased (0.3 ± 0.1 to 2.3 ± 0.1 cm s−1, P ≪ 0.01). No changes occurred in the circumflex coronary artery (CX) region. Severe ischaemia was confirmed by reduction in 2D echocardiography strain calculations. Changes in myocardial velocities assessed by miniature transducer during ischaemia differed from changes during all global interventions. Significant reduction in systolic velocity occurred at 50% LAD flow (0.9 ± 0.1 to 0.5 ± 0.1 cm s−1, P = 0.02) with further decrease on following occlusion (0.0 ± 0.0 cm s−1, P ≪ 0.01). Post-systolic velocity increased both from baseline to 50% LAD flow, and further to occlusion. Conclusion: The epicardial transducers provided continuous assessment of regional myocardial function and detected ischaemia with high sensitivity and specificity. Further development of this system may provide a useful tool for myocardial monitoring during and after cardiac surgery.