Moises Cohen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Moises Cohen has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Gustavo Gonçalves Arliani
Prevent Senior
7 shared publications - Diego Costa Astur
Department of Orthopedics and Traumatology, Federal University of São Paulo/Paulista School of Medicine (EPM/Unifesp), São Paulo/SP, Brazil
5 shared publications Joicemar Tarouco Amaro
Attending Physician in the Cohen Institute of Orthopedics, Rehabilitation and Sports Medicine, São Paulo, SP, Brazil
4 shared publications- Alberto de Castro Pochini
Universidade Federal de São Paulo, Brazil
3 shared publications - Benno Ejnisman
Universidade Federal de São Paulo, Brazil
3 shared publications - Camila Cohen Kaleka
Department of Orthopaedic Surgery Einstein Hospital Israelita São Paulo Brazil
3 shared publications
Latest Publications
- Open Access
- 17 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (10) , 525
Comparative Analysis of Osseointegration Using Titanium Implants Coated with Graphene and Niobium: An Animal Model Study
Background: Surface modification may influence tissue–implant interactions. This exploratory study compared the biomechanical, coating-integrity, and histological responses associated with uncoated titanium and carbon- or niobium-containing surface-processing conditions in a rabbit model. Methods: Twelve adult male New Zealand White rabbits were initially enrolled and allocated to 30- and 60-day healing periods. Two animals were lost before endpoint and were not replaced; ten rabbits completed the study and were analyzed, with five animals at each period. Each rabbit received four implant-site conditions: uncoated titanium, carbon-based diamond-like carbon (Graphene-DLC), niobium deposited by chemical vapor deposition (Nb-CVD), and niobium deposited by sol–gel processing (Nb-Gel). Implant stability was assessed using reverse-torque testing after formalin fixation. Histological evaluation included hematoxylin and eosin and Picrosirius Red staining. Results: At 60 days, the uncoated titanium and Graphene-DLC conditions showed the highest reported mean reverse-torque values, whereas some niobium-containing conditions showed lower reported coating-integrity scores. Ordinal histological outcomes were interpreted descriptively because the sample was small, implant sites were clustered within rabbits, and implant condition was fixed to anatomical site. Conclusions: Under this protocol, the observed differences describe combined implant-site conditions and do not provide unbiased causal evidence of coating-specific effects. The findings are exploratory and support further studies using randomized or counterbalanced allocation, clustered analysis, and independent biomechanical and histological specimens.
- 17 October 2026
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 17 (10) , 525
Open AccessComparative Analysis of Osseointegration Using Titanium Implants Coated with Graphene and Niobium: An Animal Model Study
Background: Surface modification may influence tissue–implant interactions. This exploratory study compared the biomechanical, coating-integrity, and histological responses associated with uncoated titanium and carbon- or niobium-containing surface-processing conditions in a rabbit model. Methods: Twelve adult male New Zealand White rabbits were initially enrolled and allocated to 30- and 60-day healing periods. Two animals were lost before endpoint and were not replaced; ten rabbits completed the study and were analyzed, with five animals at each period. Each rabbit received four implant-site conditions: uncoated titanium, carbon-based diamond-like carbon (Graphene-DLC), niobium deposited by chemical vapor deposition (Nb-CVD), and niobium deposited by sol–gel processing (Nb-Gel). Implant stability was assessed using reverse-torque testing after formalin fixation. Histological evaluation included hematoxylin and eosin and Picrosirius Red staining. Results: At 60 days, the uncoated titanium and Graphene-DLC conditions showed the highest reported mean reverse-torque values, whereas some niobium-containing conditions showed lower reported coating-integrity scores. Ordinal histological outcomes were interpreted descriptively because the sample was small, implant sites were clustered within rabbits, and implant condition was fixed to anatomical site. Conclusions: Under this protocol, the observed differences describe combined implant-site conditions and do not provide unbiased causal evidence of coating-specific effects. The findings are exploratory and support further studies using randomized or counterbalanced allocation, clustered analysis, and independent biomechanical and histological specimens.
- Open Access
- 27 August 2026
- Published by MDPI AG in Preprints.org
Comparative Analysis of Osseointegration Using Titanium Implants Coated with Graphene and Niobium: An Animal Model Study
Background: Nanotechnological surface modifications on titanium implants aim to optimize bone-tissue interaction, accelerate osseointegration, and prevent the release of toxic wear debris. This study evaluated the tissue response and biomechanical stability of advanced carbon- and metal-oxide-based nanocoatings in an in vivo model. Methods: Grade IV titanium implants were evaluated under four conditions using a split-body design in the distal femurs of 12 adult male New Zealand white rabbits: uncoated (control), coated with Graphene Diamond-like Carbon (DLC), Niobium via Chemical Vapor Deposition (CVD), and Niobium via Sol-Gel technique. Follow-up periods were set at 30 and 60 days. Analysis included a Reverse Torque Test (RTQ) for biomechanical stability and histopathological evaluation (H&E and Picrosirius Red under polarized light) to assess bone organization, osteoclastic proliferation, collagen matrix maturation, and coating delamination. Results: RTQ values significantly increased from 30 to 60 days across all groups (p < 0.05), with Graphene-DLC and uncoated titanium achieving the highest biomechanical anchorage. Graphene-DLC maintained excellent interfacial stability, accelerated bone mineralization (low osteoid volumes), and promoted intensive, physiologically normal bone coupling and lamellar remodeling at 60 days. Conversely, Niobium-CVD and Niobium-Gel coatings exhibited severe late-stage delamination, which released particulate debris, triggered chronic foreign body reactions, increased osteoclastic bone resorption, and compromised biomechanical interlocking. Conclusions: Graphene-DLC coatings successfully preserve structural integrity and effectively enhance functional osseointegration, matching or exceeding the biomechanical performance of conventional titanium. However, interface optimization is mandatory for Niobium-based coatings to prevent mechanical failure and debris-induced osteolysis.
- 27 August 2026
- Published by MDPI AG in Preprints.org
Open AccessComparative Analysis of Osseointegration Using Titanium Implants Coated with Graphene and Niobium: An Animal Model Study
Background: Nanotechnological surface modifications on titanium implants aim to optimize bone-tissue interaction, accelerate osseointegration, and prevent the release of toxic wear debris. This study evaluated the tissue response and biomechanical stability of advanced carbon- and metal-oxide-based nanocoatings in an in vivo model. Methods: Grade IV titanium implants were evaluated under four conditions using a split-body design in the distal femurs of 12 adult male New Zealand white rabbits: uncoated (control), coated with Graphene Diamond-like Carbon (DLC), Niobium via Chemical Vapor Deposition (CVD), and Niobium via Sol-Gel technique. Follow-up periods were set at 30 and 60 days. Analysis included a Reverse Torque Test (RTQ) for biomechanical stability and histopathological evaluation (H&E and Picrosirius Red under polarized light) to assess bone organization, osteoclastic proliferation, collagen matrix maturation, and coating delamination. Results: RTQ values significantly increased from 30 to 60 days across all groups (p < 0.05), with Graphene-DLC and uncoated titanium achieving the highest biomechanical anchorage. Graphene-DLC maintained excellent interfacial stability, accelerated bone mineralization (low osteoid volumes), and promoted intensive, physiologically normal bone coupling and lamellar remodeling at 60 days. Conversely, Niobium-CVD and Niobium-Gel coatings exhibited severe late-stage delamination, which released particulate debris, triggered chronic foreign body reactions, increased osteoclastic bone resorption, and compromised biomechanical interlocking. Conclusions: Graphene-DLC coatings successfully preserve structural integrity and effectively enhance functional osseointegration, matching or exceeding the biomechanical performance of conventional titanium. However, interface optimization is mandatory for Niobium-based coatings to prevent mechanical failure and debris-induced osteolysis.
- Open Access
- 1 October 2025
- Published by Seven Events in Revista de Geopolítica
- Vol. 16 (5) , e889
BIOCOMPATIBILIDADE DE REVESTIMENTO PROTÉTICO ALTICRN+SI3N4 EM MODELO ANIMAL SUBCUTÂNEO DE CAMUNDONGOS
A nanotecnologia utilizada como revestimento de implantes ortopédicos, neurológicos e odontológicos tem importância, cada vez maior, para fixação e durabilidade dos mesmos. A biocompatibilidade com o tecido ósseo é, portanto, fundamental. Após avaliação dos resultados feita através por análise histológica em 46 amostras de tecido subcutâneo de camundongos com e sem recobrimento de AlTiCrN+Si3N4 (Nitreto de Cromo alumínio titânio envelopadas em uma camada de nitreto de silício) verificou-se que infiltração eosinofílica, intensidade do processo inflamatório, infiltração por células gigantes multinucleada não apresentarem diferença estatística entre os dois grupos. Verificou-se fibrose no grupo com revestimento foi 1,7 vezes maior (RR = 1,7, IC 95% = 0,83 a 3,7) e presença de pigmento granular negro que caracterizou desgaste, desplacamento e/ou corrosão do cobrimento em todas as amostras. Conclui-se que tal material não tem espaço para para ser utilizado em cobrimentos nanotecnológicos de implantes metálicos.
- 1 October 2025
- Published by Seven Events in Revista de Geopolítica
- Vol. 16 (5) , e889
Open AccessBIOCOMPATIBILIDADE DE REVESTIMENTO PROTÉTICO ALTICRN+SI3N4 EM MODELO ANIMAL SUBCUTÂNEO DE CAMUNDONGOS
A nanotecnologia utilizada como revestimento de implantes ortopédicos, neurológicos e odontológicos tem importância, cada vez maior, para fixação e durabilidade dos mesmos. A biocompatibilidade com o tecido ósseo é, portanto, fundamental. Após avaliação dos resultados feita através por análise histológica em 46 amostras de tecido subcutâneo de camundongos com e sem recobrimento de AlTiCrN+Si3N4 (Nitreto de Cromo alumínio titânio envelopadas em uma camada de nitreto de silício) verificou-se que infiltração eosinofílica, intensidade do processo inflamatório, infiltração por células gigantes multinucleada não apresentarem diferença estatística entre os dois grupos. Verificou-se fibrose no grupo com revestimento foi 1,7 vezes maior (RR = 1,7, IC 95% = 0,83 a 3,7) e presença de pigmento granular negro que caracterizou desgaste, desplacamento e/ou corrosão do cobrimento em todas as amostras. Conclui-se que tal material não tem espaço para para ser utilizado em cobrimentos nanotecnológicos de implantes metálicos.
- Open Access
- 22 September 2023
- Published by Seven Events
Animal model of osteochondral injury in rabbits
Object: To study the alterations in an osteocondral surface, submitted to a standardized mechanical lesion. Methods: 30 young male rabbits were used for this experiment, being the experimental procedure performed on 60 knees. After anesthesia and antisepsis, the animals were submitted to surgical procedure for osteocondral lesion production with 4,2 X 5,0 millimeters (mm) in their condilus femoralis medialis with standardized instrumental. Three weeks after these animals were evaluated, concerning the lesion. Results: The tissue regeneration was incompatible with spontaneous resolution, developing cicatricial tissue different from the normal cartilage. Conclusions: The developed model animal is useful for study regeneration of the cartilage after mechanical lesion. The model is simple and easy to control and execute, as well as preserves the animals, which may used in other experiments, or for later observations of the previously described and analyzed phenomena in this first report. DOI:https://doi.org/10.56238/uniknowindevolp-109
- 22 September 2023
- Published by Seven Events
Open AccessAnimal model of osteochondral injury in rabbits
Object: To study the alterations in an osteocondral surface, submitted to a standardized mechanical lesion. Methods: 30 young male rabbits were used for this experiment, being the experimental procedure performed on 60 knees. After anesthesia and antisepsis, the animals were submitted to surgical procedure for osteocondral lesion production with 4,2 X 5,0 millimeters (mm) in their condilus femoralis medialis with standardized instrumental. Three weeks after these animals were evaluated, concerning the lesion. Results: The tissue regeneration was incompatible with spontaneous resolution, developing cicatricial tissue different from the normal cartilage. Conclusions: The developed model animal is useful for study regeneration of the cartilage after mechanical lesion. The model is simple and easy to control and execute, as well as preserves the animals, which may used in other experiments, or for later observations of the previously described and analyzed phenomena in this first report. DOI:https://doi.org/10.56238/uniknowindevolp-109
- Open Access
Daily Intake of Fermented Milk Containing Lactobacillus casei Shirota (Lcs) Modulates Systemic and Upper Airways Immune/Inflammatory Responses in Marathon Runners
Background. Although Lactobacillus casei Shirota (LcS) can benefit the immune status, the effects of LcS in the immune/inflammatory responses of marathon runners has never been evaluated. Therefore, here we evaluated the effect of daily ingestion of fermented milk containing or not LcS in the systemic and upper airway immune/inflammatory responses before and after a marathon. Methods. Forty-two male marathon runners ingested a fermented milk containing 40 billion of LcS/day (LcS group, n = 20) or placebo (unfermented milk, n = 22) during 30 days pre-marathon. Immune/inflammatory parameters in nasal mucosa and serum, as well as concentrations of secretory IgA (SIgA) and antimicrobial peptides in saliva, were evaluated before and after fermented milk ingestion, immediately, 72 h, and 14 d post-marathon. Results. Higher proinflammatory cytokine levels in serum and nasal mucosa, and also lower salivary levels of SIgA and antimicrobial peptides, were found immediately post-marathon in the placebo group compared to other time points and to LcS group. In opposite, higher anti-inflammatory levels and reduced neutrophil infiltration on nasal mucosa were found in the LcS group compared to other time points and to the placebo group. Conclusion. For the first time, it is shown that LcS is able to modulate the systemic and airways immune responses post-marathon.
Open AccessDaily Intake of Fermented Milk Containing Lactobacillus casei Shirota (Lcs) Modulates Systemic and Upper Airways Immune/Inflammatory Responses in Marathon Runners
Background. Although Lactobacillus casei Shirota (LcS) can benefit the immune status, the effects of LcS in the immune/inflammatory responses of marathon runners has never been evaluated. Therefore, here we evaluated the effect of daily ingestion of fermented milk containing or not LcS in the systemic and upper airway immune/inflammatory responses before and after a marathon. Methods. Forty-two male marathon runners ingested a fermented milk containing 40 billion of LcS/day (LcS group, n = 20) or placebo (unfermented milk, n = 22) during 30 days pre-marathon. Immune/inflammatory parameters in nasal mucosa and serum, as well as concentrations of secretory IgA (SIgA) and antimicrobial peptides in saliva, were evaluated before and after fermented milk ingestion, immediately, 72 h, and 14 d post-marathon. Results. Higher proinflammatory cytokine levels in serum and nasal mucosa, and also lower salivary levels of SIgA and antimicrobial peptides, were found immediately post-marathon in the placebo group compared to other time points and to LcS group. In opposite, higher anti-inflammatory levels and reduced neutrophil infiltration on nasal mucosa were found in the LcS group compared to other time points and to the placebo group. Conclusion. For the first time, it is shown that LcS is able to modulate the systemic and airways immune responses post-marathon.
- 17 March 2018
- Published by Springer Nature
- p. 149-157
Criteria-Based Return to Play After ACL Reconstruction: The Brazilian Experience
- 17 March 2018
- Published by Springer Nature
- p. 149-157
Criteria-Based Return to Play After ACL Reconstruction: The Brazilian Experience
- 27 May 2017
- Published by Springer Nature
- p. 135-138
Orthopedic Sports Disorders: Genetic and Molecular Aspects
- 27 May 2017
- Published by Springer Nature
- p. 135-138
Orthopedic Sports Disorders: Genetic and Molecular Aspects
- 10 February 2016
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (3) , 792-795
Intraarticular hamstring graft diameter decreases with continuing knee growth after ACL reconstruction with open physes
Purpose To evaluate the graft diameter size after one-year follow-up or more of patients Tanner II, III, and IV who were submitted to anterior cruciate ligament reconstruction. Methods Ten patients [five males (mean age: 14.4 years) and five females (mean age: 13.6 years)] with open physis and anterior cruciate ligament tear were submitted to transphyseal anterior cruciate ligament reconstruction with quadruple hamstrings graft. During the procedure, graft and tunnel size were recorded. After last clinical follow-up (range 1–11 years), an MRI study was requested and their measurements near the tibial tunnel were compared with the graft diameter measured and used during primary procedure. Results Four patients had Tanner stage II, four patients Tanner stage III, and two Tanner IV. There were statistically significant decreases in the quadruple hamstrings graft diameter size (average of 25.3 %). Mean size at time of surgery was 7.9 mm (±0.87), and mean size measured at different points of follow-up evaluation was 5.9 mm (±0.65). Conclusion Diameter size of hamstring graft in skeletally immature patients is smaller in most cases. If there is a decrease in the diameter of the graft along postoperative time, the risk of a re-rupture is theoretically further increased. Quadruple hamstring graft decreases a mean 25.3 % in diameter from time of anterior cruciate ligament reconstruction surgery until reassessment period in skeletally immature patients. Level of evidence IV.
- 10 February 2016
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 24 (3) , 792-795
Intraarticular hamstring graft diameter decreases with continuing knee growth after ACL reconstruction with open physes
Purpose To evaluate the graft diameter size after one-year follow-up or more of patients Tanner II, III, and IV who were submitted to anterior cruciate ligament reconstruction. Methods Ten patients [five males (mean age: 14.4 years) and five females (mean age: 13.6 years)] with open physis and anterior cruciate ligament tear were submitted to transphyseal anterior cruciate ligament reconstruction with quadruple hamstrings graft. During the procedure, graft and tunnel size were recorded. After last clinical follow-up (range 1–11 years), an MRI study was requested and their measurements near the tibial tunnel were compared with the graft diameter measured and used during primary procedure. Results Four patients had Tanner stage II, four patients Tanner stage III, and two Tanner IV. There were statistically significant decreases in the quadruple hamstrings graft diameter size (average of 25.3 %). Mean size at time of surgery was 7.9 mm (±0.87), and mean size measured at different points of follow-up evaluation was 5.9 mm (±0.65). Conclusion Diameter size of hamstring graft in skeletally immature patients is smaller in most cases. If there is a decrease in the diameter of the graft along postoperative time, the risk of a re-rupture is theoretically further increased. Quadruple hamstring graft decreases a mean 25.3 % in diameter from time of anterior cruciate ligament reconstruction surgery until reassessment period in skeletally immature patients. Level of evidence IV.
- 25 May 2015
- Vol. 56 (5) , 560-4
Rodeo athletes: management of shoulder instability.
The aim of this study was to describe epidemiological data and evaluate the clinical results of traumatic anterior glenohumeral instability in rodeo athletes. Thirteen patients, all male, with a mean age of 23.2 (18-31) years old, with anterior glenohumeral instability were include in this study. In 9 patients, the right side was affected. The mean time elapsed between injury and undergoing surgery was 56 months (24-120 months). The surgical technique used (arthroscopic or open bone block procedure) was chosen based on the ISIS (Instability Severity Index Score). Only professional athletes who had been in the sport for at least 60 months were included. Functional evaluation was conducted using the UCLA scale, after a 24-month follow-up period. The number of dislocation episodes varied from 10 to 100 (mean 27 episodes). All of the patients were submitted a surgical treatment open bone block procedure, due to their degree of sport participation, type of sport (forced overhead and collision) and the presence of associated bone defect lesions. According to UCLA criteria, the results were excellent in 12 patients and good in one. The mean time elapsed before returning to the sport was five months, varying between two and ten months. Complications included one patient developing axillary neuropraxia, which was completely resolved six months after the operation, and another patient developed a superficial skin infection. The rodeo athletes with anterior shoulder instability had serious associated bony lesions and has good outcome after bone block procedure.
- 25 May 2015
- Vol. 56 (5) , 560-4
Rodeo athletes: management of shoulder instability.
The aim of this study was to describe epidemiological data and evaluate the clinical results of traumatic anterior glenohumeral instability in rodeo athletes. Thirteen patients, all male, with a mean age of 23.2 (18-31) years old, with anterior glenohumeral instability were include in this study. In 9 patients, the right side was affected. The mean time elapsed between injury and undergoing surgery was 56 months (24-120 months). The surgical technique used (arthroscopic or open bone block procedure) was chosen based on the ISIS (Instability Severity Index Score). Only professional athletes who had been in the sport for at least 60 months were included. Functional evaluation was conducted using the UCLA scale, after a 24-month follow-up period. The number of dislocation episodes varied from 10 to 100 (mean 27 episodes). All of the patients were submitted a surgical treatment open bone block procedure, due to their degree of sport participation, type of sport (forced overhead and collision) and the presence of associated bone defect lesions. According to UCLA criteria, the results were excellent in 12 patients and good in one. The mean time elapsed before returning to the sport was five months, varying between two and ten months. Complications included one patient developing axillary neuropraxia, which was completely resolved six months after the operation, and another patient developed a superficial skin infection. The rodeo athletes with anterior shoulder instability had serious associated bony lesions and has good outcome after bone block procedure.